• Title/Summary/Keyword: Endotoxin Test

Search Result 41, Processing Time 0.03 seconds

INFLUENCE OF LOW OR HIGH ENDOTOXIN-SUSCEPTIBLE RABBIT ON PYROGEN TEST

  • Lee, Beom-Jun;Lee, Yong-Soon
    • Toxicological Research
    • /
    • v.4 no.2
    • /
    • pp.181-188
    • /
    • 1988
  • This study was carried out to investigate whether the use of the high endotoxin-sensitive or the low endotoxin-sensitive rabbits (New Zealand White strain) are more suited for the pyrogen test regulated by the Korean Pharmacopeia and United State Pharmacopeia. The results obtained were as follows. 1. The ferbrile responese were increased according to increased endotoxin doses used (i.e., 0.1, 1, 5, 10ng/kg) and the febrile responses reached to its maximum between 90 mins and 120 mins after the intravenous injection of endotoxin.

  • PDF

Validation and optimization of the in vitro LAL test for detection of endotoxin in hepatitis B vaccines

  • Park, Chul-Yong;Jung, Seung-Ha;Bak, Jong-Phil;Lee, Sun-Suk;Rhee, Dong-Kwon
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.162.1-162.1
    • /
    • 2003
  • Endotoxin has been detected by the Limulus amoebocyte lysate (LAL) test. However, aluminum hydroxide used as an adjuvant and adsorbent for the recombinant protein antigen is known to increase efficacy of lipopolysaccharide vaccine in vivo thus interfering endotoxin test. The aim of this study is to determine effect of aluminum hydroxide on the LAL test using the hepatitis B vaccine as a model and to optimize the LAL test condition not to be interfered by aluminum gydroxide. (omitted)

  • PDF

Feasibility of On-chip Detection of Endotoxin by LAL Test

  • Lee, Eun-Kyu;Suh, Chang-Woo;Hwang, Sang-Youn;Park, Hyo-Jin;Seong, Gi-Hoon;Ahn, Yoo-Min;Kim, Yang-Sun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.2
    • /
    • pp.132-136
    • /
    • 2004
  • The LAL (Limulus amebocyte lysate) test for the detection and quantification of endotoxin is based on the gelation reaction between endotoxin and LAL from a blood extract of Limulus polyphemus. The test is labor intensive, requiring dedicated personnel, a relatively long reaction time (approximately 1 h), relatively large volumes of samples and reagents and the detection of the end-point is rather subjective. To solve these problems, a miniaturized LOC (lab-on-a-chip) prototype, 62mm (L) ${\times}$ 18 mm (W), was fabricated using PDMS (polydimethylsiloxane) bonded to glass. Using this prototype, in which 2mm (W) ${\times}$ 44.3mm (L) ${\times}$ 100 $\mu\textrm{m}$ (D) microfluidic channel was constructed, turbidometric and chromogenic assay detection methods were compared, and the chromogenic method was found the most suitable for a small volume assay. In this assay, the kinetic-point method was more accurate than the end-point method. The PDMS chip thickness was found to be minimized to around 2 mm to allow sufficient light transmittance, which necessitated the use of a glass slide bonding for chip rigidity. Due to this miniaturization, the test time was reduced from 1 h to less than 10 min, and the sample volume could be reduced from 100 to ca. 4.4 ${\mu}$L. In summation, this study suggested that the LOC using the LAL test principle could be an alternative as a semi-automated and reliable method for the detection of endotoxin.

Development of an Improved Endotoxin Detection Method Using Centrifugation (원심분리법을 이용한 혈청 내 내독소의 개선된 측정방법 연구)

  • Choi, Hyeong Jwa;Lim, Yoo Jung;Lee, Eun Hee;Park, Jin Yeon;Prabagar, Miglena G.;Park, Hyung Soon;Kang, Young Sun
    • Microbiology and Biotechnology Letters
    • /
    • v.41 no.2
    • /
    • pp.242-248
    • /
    • 2013
  • Endotoxins are part of the outer membrane of the cell wall of gram-negative bacteria and are continuously released during bacterial growth. Endotoxins typically induce severe sepsis and septic shock, which cause more than 50% of mortalities. Endotoxins are easily measured in the serum by the limulus amebocyte lysate (LAL) test. However, a nonspecific result is obtained, because the high concentration of serum proteins disturbs the enzyme reaction of the LAL test. In order to solve this problem, the LAL test was performed in this study after the centrifugation of the boiled serum samples to remove the impurities. As a result, among the various conditions examined, endotoxin measurement with the LAL test was the most accurate and repeatable after centrifugation of the boiled serum at $100^{\circ}C$. Moreover, the endotoxin was accurately and repeatedly measured from the prepared sera of mice that had been administered an intraperitoneal injection of purified lipopolysaccharides (LPS) or E. coli. Therefore, the application of centrifugation to remove impurities from boiled serum gives an accurate measurement of endotoxins in the sera of normal subjects or patients, and this will lead to the improved diagnosis and prevention of diseases caused by endotoxins. In addition, the centrifugation of boiled serum samples should be considered and included in the development of endotoxin test kits.

Feasibility Study for a Lab-chip Development for LAL Test (LAL 시험용 Lab-chip 개발을 위한 타당성 연구)

  • 황상연;최효진;서창우;안유민;김양선;이은규
    • KSBB Journal
    • /
    • v.18 no.5
    • /
    • pp.429-433
    • /
    • 2003
  • LAL (Limulus amebocyte lysate) test to detect and quantity endotoxin is based on gellation reaction between endotoxin and LAL from a blood extract of Limulus polyphemus. The test is labor intensive requiring dedicated personnel, takes relatively long reaction time (approximately 1 hr), requires relatively large volume of samples and reagents, and its end-point detection method is rather subjective. To solve these problems, we attempted to develop a miniaturized LOC (lab-on-a-chip) prototype using PDMS and glass. Using the 62 mm (length) ${\times}$ 18 mm (width) prototype in which 2 mm (width) ${\times}$ 44.34 mm (length) ${\times}$ 100 $\mu\textrm{m}$ (depth) microfluidic channel was provided, we compared the various detection methods of gellation, turbidometric, and chromogenic assays to find the chromogenic method to be the most suitable for small volume assay. In this assay, kinetic point method was more accurate than end point method. We also found the PDMS chip thickness should be minimized to around 2 mm to allow sufficient light transmittance, which necessitated a glass slide bonding for chip rigidity. Through the miniaturization, the test time was reduced from 1 hr to less than 10 minutes, and the sample volume could be reduced from 100 ${\mu}\ell$ to 4.4 ${\mu}\ell$. In sum, this study revealed that the mini LOC could be an alternative for a semi-automated and reliable method for LAL test.

An Assessment of Environmental Characteristics Associated with the Level of Endotoxin Concentration in Hospital Lobbies (일부 종합 병원 로비의 공기 중 엔도톡신 농도에 미치는 환경 요인 평가)

  • Lee, Kyeong-Min;Yeom, Jeongkwan;Lee, Wonjae;Ryu, Seung-Hun;Park, Dongjin;Park, Dong-Uk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.3
    • /
    • pp.310-320
    • /
    • 2014
  • Backgrounds: Endotoxin, which found in the outer membrane of the gram-negative bacteria cell wall, makes up almost all of the lipopolysaccharide(LPS). When people are exposed to endotoxin,it can result in diverse health effects such as an airway irritation and inflammation, fever, malaise, bronchitis, allergic asthma, toxic pneumonitis, hypersensitivity lung disease. Cases among the elderly, children or pregnant can occur more frequently than a healthy adult if they are repeatedly exposed to the existing endotoxin. Therefore, we investigated and assessed the environmental characteristics associated with the airborne endotoxin concentration level in six hospital lobbies. Method: Endotoxin from indoor air in six hospital lobbies was measured by an area sampling method and analyzed according to American Society for Testing and Materials International(ASTM international) E2144-01. Total suspended particulate(TSP), carbon dioxide($CO_2$), temperature and humidity were also measured by using direct reading measurements or airborne sampling equipment at the same time. Environmental characteristics were appropriately divided into two or three groups for a statistics analysis. One-way analysis variable(one-way ANOVA) was used to examine a difference of the endotoxin concentration, depending on the environmental characteristics. In addition, only variables with p-value(p<0.25) were eventually designed to the best model by using multiple regression analysis. Results: The correlation analysis result indicated that TSP(p=0.003) and $CO_2$(p<0.0001) levels were significantly associated with endotoxin concentration levels. In contrast, temperature(p<0.068) and humidity(p<0.365) were not associated with endotoxin concentration. Levels of endotoxin concentration were statistically different among the environmental characteristics of Service time(p=0.01), Establishment of hospital(p<0.001), Scale of hospital(p=0.01), Day average people using hospital(p=0.03), Cleaning time of lobby(p=0.05), Season(p<0.001), and Cleaning of ventilation system(p<0.001) according to ANOVA. Finally, the best model(Adjusted R-square=72%) that we designed through a multiple regression test included environmental characteristics related to Service time, Area of lobby, Season, Cleaning of ventilation system, and Temperature. Conclusions: According to this study, our result showed a normal level of endotoxin concentration in the hospital lobbies and found environmental management methods to reduce the level of endotoxin concentration to a minimum. Consequently, this study recognized to be requirement for the management of ventilation systems and an indoor temperature in order to reduce the level of endotoxin concentration in the hospital lobbies.

Purification of hemolysin in mosquitocidal delta-endotoxin from Bacillus thuringiensis subsp. darmstadiensis 73E10-2 (모기유충에 살충력이 있는 Bacillus thuringiensis subsp. darmstadiensis 73E10-2의 내독소의 용혈성 인자의 정제)

  • 김광현;이기희;홍용기
    • Microbiology and Biotechnology Letters
    • /
    • v.19 no.3
    • /
    • pp.303-307
    • /
    • 1991
  • The hemolyic polypeptide in delta-endotoxin from Bacillus thun'ngiensis subsp. darmstadiensis 73ElO-2 was purified by Sephadex G-IOO gel filtration and DEAE-cellulose ion exchange column chromatography. The purity of hemolysin was confirmed by ouchterlony test and SDS-PAGE. The molecular weight of the purified hemolysin was approximately 64 KDa by SDS-PAGE. The purified hemolysin has not mosquitocidal activity against larvae of Aedes agypti, but hemolytic activity on red blood cells of rat. There is no serological relationship between delta-endotoxin from B. thuringiensis subsp. israelensis and the purified hemolysin from the . strain 73ElO-2.

  • PDF

Characterization of Mosquitocidal Bacillus thuringiensis Strain H9B (모기유층에 대한 살충성 Bacillus thuringiensis H9B 균주의 특성)

  • 이기희;김광현;김병우
    • Microbiology and Biotechnology Letters
    • /
    • v.21 no.5
    • /
    • pp.393-398
    • /
    • 1993
  • One strain of mosquitocidal Bacillus thuringiensis, H9B, was isolated from soil. The biochemical characteristics and flagella antigenicity of the strain H9B is similar to that of B. thuringiensis subsp. darmstadiensis. The delta-endotoxin of the strain H9B coincided with that of B. thuringiensis subsp. darmstadiensis strain 73E10-2 on agarose double immunodiffusion test. The delta-endotoxin of B. thuringiensis subsp. israelensis contains hemolysin fragment (28 kb) on SDS-PAGE when the delta-endotoxin was solubilized in alkali, while that of the strain H9B does not contain 28 kb protein.

  • PDF

Comparison of Quantitative Endotoxin against 5 Species of Enterobacteriaceae (장내세균 5종의 Endotoxin 정량 비교)

  • Kwon, Pil Seung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.2
    • /
    • pp.124-129
    • /
    • 2016
  • Endotoxin, also known as lipopolysaccharide (LPS) produced by the cell wall of gram negative bacteria can be present in any liquid or on any biomaterial. Endotoxin in blood can cause fever and inflammation. In this study, we compared bacterial endotoxin using Escherichia coli O157:H7, Klebsiella oxytoca, Salmonella Typhi, Shigella sonnei and Morganella morganii. Bacteria were cultured for use in the experiment, and diluted to $1.5{\times}10^8CFU/mL$. A check marked sensitivity confirmatory test of the Limulus amebocyte lysate (LAL) reagent was performed to examine the validity. The end point reaction to each bacteria sample was confirmed with 10 fold dilution and then the final reaction end point was confirmed by 2 fold dilution between the dilution step and the upper dilution step. According to the results, in detection of endotoxins in more than 0.015 EU/mL, E. coli O157 was 75~37.5 CFU/mL, K. oxytoca 37.5~18.75 CFU/mL, M. morganii and S. Typhi 3.75~1.875 CFU/mL, and S. sonnei 7.5~3.75 CFU/mL. The resulting value was finally ensured by a confirmation test for the inhibitory factor. Based on this study, conduct of further research on bacterial endotoxin is encouraged.

The Endotoxin Assay of Contaminated Titanium Implants following Various Techniques of Detoxification (오염된 임프란트 표면의 해독 방법에 따른 내독소 제거 효과에 관한 연구)

  • Park, Joong-Hee;Lim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.71-81
    • /
    • 2004
  • Peri-implantitis could be the result of biomechanical and occlusal overload as well as microbiologic invasion. The dental implant may be more susceptible to dental plaque than the natural tooth, as the predictability of a stable soft tissue attachment complex has not yet been confirmed. With the development of peri-implantitis, the implant surface would be exposed to the oral environment and becomes coated with bacteria. The objective of therapy for this condition is to regain integration of the implant with bone. Since fibroblast adherence to surfaces is impeded by endotoxin, it would seem that decontamination would be desirable to obtain maximum osseointegration. The purpose of this study was to determine whether various chemotherapeutic and mechanical treatments(distilled water, air-powder abrasive, hypersaturated citric acid, tetracycline) can detoxify contaminated titanium implant surface by means of kinetic LAL test. Experimental rough surface titanium disks were fabricated. All of them were divided into two groups(A.a group and P.g group) and each contaminated by A. actinomycetemcomitans and P. gingivalis suspension. Contaminated disks were treated with distilled water, air-powder abrasive, citric acid and tetracycline, and then all disks were placed into LPS-free water for elution. The results were as follows : 1. In A.a group, LPS elute level of all test groups were significantly lower than control group(p<0.05). 2. In A.a group, LPS elute level of test 2, test 3 and test4 groups were significantly lower than that of control group(p<0.05). But, among the test 2, test 3, test4 groups, the significant differences were not detected. 3. In P.g group, LPS elute level of test 2, test 3 and test 4 groups were lower than that of control group(p<0.05). But, among the test groups, the significant differences were not detected. From the result of this study, it would be concluded that air-powder abrasive, hypersaturated citric acid and tetracycline treatments may be effective at reducing endotoxin level on rough titanium implant surfaces, and can be clinically used. But the treatments in peri-implantitis differentially impact osseointegration making one method clinically superior. To gain this knowledges, further molecular biologic and histopathologic studies should be developed.