• 제목/요약/키워드: Endotoxin Test

검색결과 41건 처리시간 0.029초

INFLUENCE OF LOW OR HIGH ENDOTOXIN-SUSCEPTIBLE RABBIT ON PYROGEN TEST

  • Lee, Beom-Jun;Lee, Yong-Soon
    • Toxicological Research
    • /
    • 제4권2호
    • /
    • pp.181-188
    • /
    • 1988
  • This study was carried out to investigate whether the use of the high endotoxin-sensitive or the low endotoxin-sensitive rabbits (New Zealand White strain) are more suited for the pyrogen test regulated by the Korean Pharmacopeia and United State Pharmacopeia. The results obtained were as follows. 1. The ferbrile responese were increased according to increased endotoxin doses used (i.e., 0.1, 1, 5, 10ng/kg) and the febrile responses reached to its maximum between 90 mins and 120 mins after the intravenous injection of endotoxin.

  • PDF

Validation and optimization of the in vitro LAL test for detection of endotoxin in hepatitis B vaccines

  • Park, Chul-Yong;Jung, Seung-Ha;Bak, Jong-Phil;Lee, Sun-Suk;Rhee, Dong-Kwon
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.162.1-162.1
    • /
    • 2003
  • Endotoxin has been detected by the Limulus amoebocyte lysate (LAL) test. However, aluminum hydroxide used as an adjuvant and adsorbent for the recombinant protein antigen is known to increase efficacy of lipopolysaccharide vaccine in vivo thus interfering endotoxin test. The aim of this study is to determine effect of aluminum hydroxide on the LAL test using the hepatitis B vaccine as a model and to optimize the LAL test condition not to be interfered by aluminum gydroxide. (omitted)

  • PDF

Feasibility of On-chip Detection of Endotoxin by LAL Test

  • Lee, Eun-Kyu;Suh, Chang-Woo;Hwang, Sang-Youn;Park, Hyo-Jin;Seong, Gi-Hoon;Ahn, Yoo-Min;Kim, Yang-Sun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제9권2호
    • /
    • pp.132-136
    • /
    • 2004
  • The LAL (Limulus amebocyte lysate) test for the detection and quantification of endotoxin is based on the gelation reaction between endotoxin and LAL from a blood extract of Limulus polyphemus. The test is labor intensive, requiring dedicated personnel, a relatively long reaction time (approximately 1 h), relatively large volumes of samples and reagents and the detection of the end-point is rather subjective. To solve these problems, a miniaturized LOC (lab-on-a-chip) prototype, 62mm (L) ${\times}$ 18 mm (W), was fabricated using PDMS (polydimethylsiloxane) bonded to glass. Using this prototype, in which 2mm (W) ${\times}$ 44.3mm (L) ${\times}$ 100 $\mu\textrm{m}$ (D) microfluidic channel was constructed, turbidometric and chromogenic assay detection methods were compared, and the chromogenic method was found the most suitable for a small volume assay. In this assay, the kinetic-point method was more accurate than the end-point method. The PDMS chip thickness was found to be minimized to around 2 mm to allow sufficient light transmittance, which necessitated the use of a glass slide bonding for chip rigidity. Due to this miniaturization, the test time was reduced from 1 h to less than 10 min, and the sample volume could be reduced from 100 to ca. 4.4 ${\mu}$L. In summation, this study suggested that the LOC using the LAL test principle could be an alternative as a semi-automated and reliable method for the detection of endotoxin.

원심분리법을 이용한 혈청 내 내독소의 개선된 측정방법 연구 (Development of an Improved Endotoxin Detection Method Using Centrifugation)

  • 최형좌;임유정;이은희;박진연;미글레나;박형순;강영선
    • 한국미생물·생명공학회지
    • /
    • 제41권2호
    • /
    • pp.242-248
    • /
    • 2013
  • Endotoxins are part of the outer membrane of the cell wall of gram-negative bacteria and are continuously released during bacterial growth. Endotoxins typically induce severe sepsis and septic shock, which cause more than 50% of mortalities. Endotoxins are easily measured in the serum by the limulus amebocyte lysate (LAL) test. However, a nonspecific result is obtained, because the high concentration of serum proteins disturbs the enzyme reaction of the LAL test. In order to solve this problem, the LAL test was performed in this study after the centrifugation of the boiled serum samples to remove the impurities. As a result, among the various conditions examined, endotoxin measurement with the LAL test was the most accurate and repeatable after centrifugation of the boiled serum at $100^{\circ}C$. Moreover, the endotoxin was accurately and repeatedly measured from the prepared sera of mice that had been administered an intraperitoneal injection of purified lipopolysaccharides (LPS) or E. coli. Therefore, the application of centrifugation to remove impurities from boiled serum gives an accurate measurement of endotoxins in the sera of normal subjects or patients, and this will lead to the improved diagnosis and prevention of diseases caused by endotoxins. In addition, the centrifugation of boiled serum samples should be considered and included in the development of endotoxin test kits.

LAL 시험용 Lab-chip 개발을 위한 타당성 연구 (Feasibility Study for a Lab-chip Development for LAL Test)

  • 황상연;최효진;서창우;안유민;김양선;이은규
    • KSBB Journal
    • /
    • 제18권5호
    • /
    • pp.429-433
    • /
    • 2003
  • LAL 측정용 chip을 제작하기 위해서 우선 시료의 부피 감소에 대한 비탁법과 비색법을 비교하였다. 비색법은 낮은 부피에서 높은 감도를 보여 주었으며 시료의 부피와 무관하게 같은 endotoxin의 농도에서는 같은 흡광도를 보인다는 결론을 얻었다. Endotoxin의 농도에 따른 표준곡선을 end point법과 kinetic point법을 비교한 결과 대한약전의 기준에 적합한 kinetic point법이 적합하였다. 이러한 기초 실험결과를 통해 PDMS LOC를 제작하여 LAL 시험을 수행하였다. LOC를 이용하여 더 짧은 시간과 더 작은 시료로 시험이 가능하도록 하였다. 특히 PDMS LOC는 복잡한 channel을 쉽게 만들 수 있을 뿐 아니라 mold를 이용하여 상용화를 위한 대량 생산이 가능하다. 따라서 PDMS를 이용한 LOC의 제작과 실험을 통해 기존의 수작업의 LAL 시험을 LOC를 이용한 다중시료 측정과 자동화의 가능성을 제시하였다.

일부 종합 병원 로비의 공기 중 엔도톡신 농도에 미치는 환경 요인 평가 (An Assessment of Environmental Characteristics Associated with the Level of Endotoxin Concentration in Hospital Lobbies)

  • 이경민;염정관;이원재;류승훈;박동진;박동욱
    • 한국산업보건학회지
    • /
    • 제24권3호
    • /
    • pp.310-320
    • /
    • 2014
  • Backgrounds: Endotoxin, which found in the outer membrane of the gram-negative bacteria cell wall, makes up almost all of the lipopolysaccharide(LPS). When people are exposed to endotoxin,it can result in diverse health effects such as an airway irritation and inflammation, fever, malaise, bronchitis, allergic asthma, toxic pneumonitis, hypersensitivity lung disease. Cases among the elderly, children or pregnant can occur more frequently than a healthy adult if they are repeatedly exposed to the existing endotoxin. Therefore, we investigated and assessed the environmental characteristics associated with the airborne endotoxin concentration level in six hospital lobbies. Method: Endotoxin from indoor air in six hospital lobbies was measured by an area sampling method and analyzed according to American Society for Testing and Materials International(ASTM international) E2144-01. Total suspended particulate(TSP), carbon dioxide($CO_2$), temperature and humidity were also measured by using direct reading measurements or airborne sampling equipment at the same time. Environmental characteristics were appropriately divided into two or three groups for a statistics analysis. One-way analysis variable(one-way ANOVA) was used to examine a difference of the endotoxin concentration, depending on the environmental characteristics. In addition, only variables with p-value(p<0.25) were eventually designed to the best model by using multiple regression analysis. Results: The correlation analysis result indicated that TSP(p=0.003) and $CO_2$(p<0.0001) levels were significantly associated with endotoxin concentration levels. In contrast, temperature(p<0.068) and humidity(p<0.365) were not associated with endotoxin concentration. Levels of endotoxin concentration were statistically different among the environmental characteristics of Service time(p=0.01), Establishment of hospital(p<0.001), Scale of hospital(p=0.01), Day average people using hospital(p=0.03), Cleaning time of lobby(p=0.05), Season(p<0.001), and Cleaning of ventilation system(p<0.001) according to ANOVA. Finally, the best model(Adjusted R-square=72%) that we designed through a multiple regression test included environmental characteristics related to Service time, Area of lobby, Season, Cleaning of ventilation system, and Temperature. Conclusions: According to this study, our result showed a normal level of endotoxin concentration in the hospital lobbies and found environmental management methods to reduce the level of endotoxin concentration to a minimum. Consequently, this study recognized to be requirement for the management of ventilation systems and an indoor temperature in order to reduce the level of endotoxin concentration in the hospital lobbies.

모기유충에 살충력이 있는 Bacillus thuringiensis subsp. darmstadiensis 73E10-2의 내독소의 용혈성 인자의 정제 (Purification of hemolysin in mosquitocidal delta-endotoxin from Bacillus thuringiensis subsp. darmstadiensis 73E10-2)

  • 김광현;이기희;홍용기
    • 한국미생물·생명공학회지
    • /
    • 제19권3호
    • /
    • pp.303-307
    • /
    • 1991
  • B.thuringiensis subsp. darmstadiensis 73E10-2의 내독소에 존재하는 hemolysin이 Sephadex G-100 gel filtration과 DEAE-cellulose ion exchange column chromatography에 의해 정제되었으며, 그 순도는 SDS-PAGE와 Ouchterlony test로 확인하였다. 그 결과 정제된 hemolysin의 분자량은 64KDa 의 단백질 이었으며, in vivo 상태에서는 전혀 모기유충에 독작용을 나타내지 않았다는 점이 28KDa 단백질의 차이가 있었다. 또한 정제된 hemolysin과 B.thuringiensis subsp. israelensis의 내독소를 효소항체법으로 검토해 본 결과 양단백질 사이에는 면역학적으로 전혀 상관이 없었다.

  • PDF

모기유층에 대한 살충성 Bacillus thuringiensis H9B 균주의 특성 (Characterization of Mosquitocidal Bacillus thuringiensis Strain H9B)

  • 이기희;김광현;김병우
    • 한국미생물·생명공학회지
    • /
    • 제21권5호
    • /
    • pp.393-398
    • /
    • 1993
  • One strain of mosquitocidal Bacillus thuringiensis, H9B, was isolated from soil. The biochemical characteristics and flagella antigenicity of the strain H9B is similar to that of B. thuringiensis subsp. darmstadiensis. The delta-endotoxin of the strain H9B coincided with that of B. thuringiensis subsp. darmstadiensis strain 73E10-2 on agarose double immunodiffusion test. The delta-endotoxin of B. thuringiensis subsp. israelensis contains hemolysin fragment (28 kb) on SDS-PAGE when the delta-endotoxin was solubilized in alkali, while that of the strain H9B does not contain 28 kb protein.

  • PDF

장내세균 5종의 Endotoxin 정량 비교 (Comparison of Quantitative Endotoxin against 5 Species of Enterobacteriaceae)

  • 권필승
    • 대한임상검사과학회지
    • /
    • 제48권2호
    • /
    • pp.124-129
    • /
    • 2016
  • 세균내독소는 lipopolysaccharide (LPS)라고 불리우며, 그람음성 세균의 세포벽에 존재하는 물질로 어느 생체재료나 액체에 존재할 수 있다. 세균내독소가 혈액으로 침투되면 발열 및 염증을 유발시킨다. 본 연구에서는 장내 그람음성세균인 Escherichia coli O157:H7, Klebsiella oxytoca, Salmonella Typhi, Shigella sonnei, Morganella morganii의 LPS 양을 비교하려 하였다. 각 세균은 배양한 후 $1.5{\times}10^8CFU/mL$ 농도로 희석하여 동일한 농도로 하였으며 실험의 정당성을 위하여 LAL시약의 표시감도확인시험을 진행하였다. 10 fold dilution 후 1차 시험을 하여 각 균의 반응 end point를 확인하고 바로 윗단계 희석배수 사이에서 2 fold dilution하여 균의 최종 반응 end point를 확인하였다. 결과적으로 E. coli O157은 75~37.5 CFU/mL, K. oxytoca는 37.5~18.75 CFU/mL, M. morganii와 S. Typhi는 3.75~1.875 CFU/mL, S. sonnei는 7.5~3.75 CFU/mL에서 0.015 EU/mL 이상의 endotoxin이 검출되었다. 최종적으로 억제인자에 대한 확인시험을 진행하여 결과값을 보증하였다. 본 연구를 통하여 세균내독소에 대한 추가적인 연구가 지속되기를 기원한다.

오염된 임프란트 표면의 해독 방법에 따른 내독소 제거 효과에 관한 연구 (The Endotoxin Assay of Contaminated Titanium Implants following Various Techniques of Detoxification)

  • 박중희;임성빈
    • Journal of Periodontal and Implant Science
    • /
    • 제34권1호
    • /
    • pp.71-81
    • /
    • 2004
  • Peri-implantitis could be the result of biomechanical and occlusal overload as well as microbiologic invasion. The dental implant may be more susceptible to dental plaque than the natural tooth, as the predictability of a stable soft tissue attachment complex has not yet been confirmed. With the development of peri-implantitis, the implant surface would be exposed to the oral environment and becomes coated with bacteria. The objective of therapy for this condition is to regain integration of the implant with bone. Since fibroblast adherence to surfaces is impeded by endotoxin, it would seem that decontamination would be desirable to obtain maximum osseointegration. The purpose of this study was to determine whether various chemotherapeutic and mechanical treatments(distilled water, air-powder abrasive, hypersaturated citric acid, tetracycline) can detoxify contaminated titanium implant surface by means of kinetic LAL test. Experimental rough surface titanium disks were fabricated. All of them were divided into two groups(A.a group and P.g group) and each contaminated by A. actinomycetemcomitans and P. gingivalis suspension. Contaminated disks were treated with distilled water, air-powder abrasive, citric acid and tetracycline, and then all disks were placed into LPS-free water for elution. The results were as follows : 1. In A.a group, LPS elute level of all test groups were significantly lower than control group(p<0.05). 2. In A.a group, LPS elute level of test 2, test 3 and test4 groups were significantly lower than that of control group(p<0.05). But, among the test 2, test 3, test4 groups, the significant differences were not detected. 3. In P.g group, LPS elute level of test 2, test 3 and test 4 groups were lower than that of control group(p<0.05). But, among the test groups, the significant differences were not detected. From the result of this study, it would be concluded that air-powder abrasive, hypersaturated citric acid and tetracycline treatments may be effective at reducing endotoxin level on rough titanium implant surfaces, and can be clinically used. But the treatments in peri-implantitis differentially impact osseointegration making one method clinically superior. To gain this knowledges, further molecular biologic and histopathologic studies should be developed.