• Title/Summary/Keyword: Endoscopy, gastrointestinal

Search Result 588, Processing Time 0.032 seconds

Evaluation of the mechanical properties of current biliary selfexpandable metallic stents: axial and radial force, and axial force zero border

  • Wataru Yamagata;Toshio Fujisawa;Takashi Sasaki;Rei Ishibashi;Tomotaka Saito;Shuntaro Yoshida;Shizuka No;Kouta Inoue;Yousuke Nakai;Naoki Sasahira;Hiroyuki Isayama
    • Clinical Endoscopy
    • /
    • v.56 no.5
    • /
    • pp.633-649
    • /
    • 2023
  • Background/Aims: Mechanical properties (MPs) and axial and radial force (AF and RF) may influence the efficacy and complications of self-expandable metallic stent (SEMS) placement. We measured the MPs of various SEMSs and examined their influence on the SEMS clinical ability. Methods: We evaluated the MPs of 29 types of 10-mm SEMSs. RF was measured using a conventional measurement device. AF was measured using the conventional and new methods, and the correlation between the methods was evaluated. Results: A high correlation in AFs was observed, as measured by the new and conventional manual methods. AF and RF scatterplots divided the SEMSs into three subgroups according to structure: hook-and-cross-type (low AF and RF), cross-type (high AF and low RF), and laser-cut-type (intermediate AF and high RF). The hook-and-cross-type had the largest axial force zero border (>20°), followed by the laser-cut and cross types. Conclusions: MPs were related to stent structure. Hook-and-cross-type SEMSs had a low AF and high axial force zero border and were considered safest because they caused minimal stress on the biliary wall. However, the increase in RF must be overcome.

Characteristics of Metachronous Remnant Gastric Cancer After Proximal Gastrectomy: A Retrospective Analysis

  • Kenichi Ishizu;Tsutomu Hayashi;Rei Ogawa;Masashi Nishino;Ryota Sakon;Takeyuki Wada;Sho Otsuki;Yukinori Yamagata ;Hitoshi Katai;Yoshiyuki Matsui;Takaki Yoshikawa
    • Journal of Gastric Cancer
    • /
    • v.24 no.3
    • /
    • pp.280-290
    • /
    • 2024
  • Purpose: Despite annual endoscopy, patients with metachronous remnant gastric cancer (MRGC) following proximal gastrectomy (PG) are at times ineligible for endoscopic resection (ER). This study aimed to clarify the clinical risk factors for ER inapplicability. Materials and Methods: We reviewed the records of 203 patients who underwent PG for cT1 gastric cancer between 2006 and 2015. The remnant stomach was categorized as a pseudofornix, corpus, or antrum. Results: Thirty-two MRGCs were identified in the 29 patients. Twenty MRGCs were classified as ER (ER group, 62.5%), whereas 12 were not (non-ER group, 37.5%). MRGCs were located in the pseudo-fornix in 1, corpus in 5, and antrum in 14 in the ER group, and in the pseudofornix in 6, corpus in 4, and antrum in 2 in the non-ER group (P=0.019). Multivariate analysis revealed that the pseudo-fornix was an independent risk factor for non-ER (P=0.014). In the non-ER group, MRGCs at the pseudo-fornix (n=6) had more frequent undifferentiated-type histology (4/6 vs. 0/6), deeper (≥pT1b2; 6/6 vs. 2/6) and nodal metastasis (3/6 vs. 0/6) than non-pseudo-fornix lesions (n=6). We examined the visibility of the region developing MRGC on an annual follow-up endoscopy one year before MRGC detection. In seven lesions at the pseudofornix, visibility was only secured in two (28.6%) because of food residues. Of the 25 lesions in the non-pseudo-fornix, visibility was secured in 21 lesions (84%; P=0.010). Conclusions: Endoscopic visibility increases the chances of ER applicability. Special preparation is required to ensure the complete clearance of food residues in the pseudo-fornix.

The role of needle-based confocal laser endomicroscopy in the diagnosis of pancreatic neuroendocrine tumors

  • Masanori Yamada;Kazuo Hara;Nobumasa Mizuno;Shin Haba;Takamichi Kuwahara;Nozomi Okuno;Yasuhiro Kuraishi;Takafumi Yanaidani;Sho Ishikawa;Tsukasa Yasuda;Toshitaka Fukui
    • Clinical Endoscopy
    • /
    • v.57 no.3
    • /
    • pp.393-401
    • /
    • 2024
  • Background/Aims: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is a highly accurate method for diagnosing pancreatic neuroendocrine tumors (PNETs); however, some PNETs are difficult to diagnose. Recently, the efficacy of needle-based confocal laser endomicroscopy (nCLE) in diagnosing solid pancreatic masses has been reported. However, the efficacy of nCLE in the diagnosis of PNETs remains unknown and only a small number of cases have been reported. Hence, this study aimed to evaluate the efficacy of nCLE in the diagnosis of PNETs. Methods: This single-center retrospective study evaluated 30 consecutive patients with suspected PNETs on contrast-enhanced computed tomography, who consented to nCLE combined with EUS-FNA and were diagnosed using EUS-FNA or surgical resection. The diagnostic criteria for PNETs using nCLE were based on the nesting and trabecular and glandular arrangement of tumor cell clusters surrounded by capillary vessels and fibrosis, as reported in previous studies. Results: The diagnosis using nCLE was classified into three categories: misdiagnosis in three cases (10%), non-diagnostic in six cases (20%), and diagnostic in 21 cases (70%). nCLE was able to diagnose PNET in one of the two cases with inconclusive EUS-FNA. Conclusions: Although further development of the resolution and optimization of the diagnostic criteria are required, nCLE may constitute a useful diagnostic option in cases of inconclusive EUS-FNA for PNETs.

Safety of endoscopic ultrasound-guided hepaticogastrostomy in patients with malignant biliary obstruction and ascites

  • Tsukasa Yasuda;Kazuo Hara;Nobumasa Mizuno;Shin Haba;Takamichi Kuwahara;Nozomi Okuno;Yasuhiro Kuraishi;Takafumi Yanaidani;Sho Ishikawa;Masanori Yamada;Toshitaka Fukui
    • Clinical Endoscopy
    • /
    • v.57 no.2
    • /
    • pp.246-252
    • /
    • 2024
  • Background/Aims: Endoscopic ultrasound (EUS)-guided hepaticogastrostomy (EUS-HGS) is useful for patients with biliary cannulation failure or inaccessible papillae. However, it can lead to serious complications such as bile peritonitis in patients with ascites; therefore, development of a safe method to perform EUS-HGS is important. Herein, we evaluated the safety of EUS-HGS with continuous ascitic fluid drainage in patients with ascites. Methods: Patients with moderate or severe ascites who underwent continuous ascites drainage, which was initiated before EUS-HGS and terminated after the procedure at our institution between April 2015 and December 2022, were included in the study. We evaluated the technical and clinical success rates, EUS-HGS-related complications, and feasibility of re-intervention. Results: Ten patients underwent continuous ascites drainage, which was initiated before EUS-HGS and terminated after completion of the procedure. Median duration of ascites drainage before and after EUS-HGS was 2 and 4 days, respectively. Technical success with EUS-HGS was achieved in all 10 patients (100%). Clinical success with EUS-HGS was achieved in 9 of the 10 patients (90%). No endoscopic complications such as bile peritonitis were observed. Conclusions: In patients with ascites, continuous ascites drainage, which is initiated before EUS-HGS and terminated after completion of the procedure, may prevent complications and allow safe performance of EUS-HGS.

Comparison of scissor-type knife to non-scissor-type knife for endoscopic submucosal dissection: a systematic review and meta-analysis

  • Harishankar Gopakumar;Ishaan Vohra;Srinivas Reddy Puli;Neil R Sharma
    • Clinical Endoscopy
    • /
    • v.57 no.1
    • /
    • pp.36-47
    • /
    • 2024
  • Background/Aims: Scissor-type endoscopic submucosal dissection (ST-ESD) knives can reduce the adverse events associated with ESDs. This study aimed to compare ST-ESD and non-scissor-type (NST)-ESD knives. Methods: We identified ten studies that compared the performance characteristics and safety profiles of ST-ESD and NST-ESD knives. Fixed- and random-effects models were used to calculate the pooled proportions. Heterogeneity was assessed using the I2 test. Results: On comparing ST-ESD knives to NST-ESD knives, the weighted odds of en bloc resection was 1.61 (95% confidence interval [CI], 0.90-2.90; p=0.14), R0 resection was 1.10 (95% CI, 0.71-1.71; p=0.73), delayed bleeding was 0.40 (95% CI, 0.17-0.90; p=0.03), perforation was 0.35 (95% CI, 0.18-0.70; p<0.01) and ESD self-completion by non-experts was 1.89 (95% CI, 1.20-2.95; p<0.01). There was no heterogeneity, with an I2 score of 0% (95% CI, 0%-54.40%). Conclusions: The findings of reduced odds of perforation, a trend toward reduced delayed bleeding, and an improvement in the rates of en bloc and R0 resection with ST-ESD knives compared to NST-ESD knives support the use of ST-ESD knives when non-experts perform ESDs or as an adjunct tool for challenging ESD procedures.

Safety and efficacy of novel oblique-viewing scope for B2-endoscopic ultrasound-guided hepaticogastrostomy

  • Sho Ishikawa;Kazuo Hara;Nozomi Okuno;Nobumasa Mizuno;Shin Haba;Takamichi Kuwahara;Yasuhiro Kuraishi;Takafumi Yanaidani;Masanori Yamada;Tsukasa Yasuda;Toshitaka Fukui;Teru Kumagi;Yoichi Hiasa
    • Clinical Endoscopy
    • /
    • v.57 no.4
    • /
    • pp.527-533
    • /
    • 2024
  • Background/Aims: Endoscopic ultrasound (EUS)-guided hepaticogastrostomy (EUS-HGS) performed at the intrahepatic bile duct segment 3 (B3) is widely used for biliary drainage. Although performing post-puncture procedures is easier in the intrahepatic bile duct segment 2 (B2) when using a conventional oblique-viewing (OV) EUS scope, this method may cause transesophageal puncture and severe adverse events. We evaluated the safety and efficacy of B2 puncture using a novel OV-EUS scope. Methods: In this single-center retrospective study, we prospectively enrolled and collected data from 45 patients who consecutively underwent EUS-HGS procedures with a novel OV-EUS scope between September 2021 and December 2022 at our cancer center. Results: The technical success rates of B2-EUS-HGS and EUS-HGS were 93.3% (42/45) and 97.8% (44/45), respectively. The early adverse event rate was 8.9% (4/45) with no cases of scope changes or transesophageal punctures. The median procedure time was 13 minutes (range, 5-30). Conclusions: B2-EUS-HGS can be performed safely with the novel EG-740UT (Fujifilm) OV-scope without transesophageal puncture and with a high success rate. B2-EUS-HGS using this novel OV scope may be the preferred strategy for EUS-HGS.

Underestimation of endoscopic size in large gastric epithelial neoplasms

  • Jae Sun Song;Byung Sun Kim;Min A Yang;Young Jae Lee;Gum Mo Jung;Ji Woong Kim;Jin Woong Cho
    • Clinical Endoscopy
    • /
    • v.55 no.6
    • /
    • pp.760-766
    • /
    • 2022
  • Background/Aims: Endoscopic submucosal dissection (ESD) is an effective method for resecting gastric adenomas and adenocarcinomas. A significant discrepancy was observed between endoscopic and pathological sizes in samples obtained from patients undergoing ESD. This study elucidates the factors affecting size discrepancy after formalin fixation. Methods: The records of 64 patients with 69 lesions were analyzed, including 50 adenomas and 19 adenocarcinomas. Data on location, gross shape, histology, and size after fixation in formalin were collected. Results: The mean size of the resected specimen appeared to decrease after formalin fixation (37.5 mm prefixation vs. 35.8 mm postfixation, p<0.05). The mean long axis diameter of the lesions was 20.3±7.9 mm prefixation and 13.4±7.9 mm postfixation. Size differences in lesions smaller than 20 mm were significantly greater than those in lesions larger than 20 mm (7.6±5.6 mm vs. 2.5±5.8 mm, p<0.01). In multivariate analysis, a tumor size of ≥20 mm was found to be an independent factor affecting size postformalin fixation (p<0.05). Conclusions: The endoscopic size of lesions before ESD may be underestimated in tumors larger than 20 mm in size. Therefore, increased attention must be paid during ESD to avoid instances of incomplete resection.

Bispectral index-guided propofol sedation during endoscopic ultrasonography

  • Ayana Okamoto;Ken Kamata;Takeshi Miyata;Tomoe Yoshikawa;Rei Ishikawa;Tomohiro Yamazaki;Atsushi Nakai;Shunsuke Omoto;Kosuke Minaga;Kentaro Yamao;Mamoru Takenaka;Yasutaka Chiba;Toshiharu Sakurai;Naoshi Nishida;Masayuki Kitano;Masatoshi Kudo
    • Clinical Endoscopy
    • /
    • v.55 no.4
    • /
    • pp.558-563
    • /
    • 2022
  • Background/Aims: Bispectral index (BIS) monitors process and display electroencephalographic data are used to assess the depth of anesthesia. This study retrospectively evaluated the usefulness of BIS monitoring during endoscopic ultrasonography (EUS). Methods: This study included 725 consecutive patients who underwent EUS under sedation with propofol. BIS monitoring was used in 364 patients and was not used in 361. The following parameters were evaluated: (1) median dose of propofol; (2) respiratory and circulatory depression; (3) occurrence of body movements; (4) awakening score >8 at the time; and (5) awakening score 2 hours after leaving the endoscopy room. Results: The BIS group received a significantly lower median dose of propofol than the non-BIS group (159.2 mg vs. 167.5 mg; p=0.015) in all age groups. For patients aged ≥75 years, the reduction in heart rate was significantly lower in the BIS group than in the non-BIS group (1.2% vs. 9.1%; p=0.023). Moreover, the occurrence of body movements was markedly lower in the BIS group than in the non-BIS group (8.5% vs. 39.4%; p<0.001). Conclusions: During EUS examination, BIS monitoring is useful for maintaining a constant depth of anesthesia, especially in patients 75 years of age or older.

Safe implementation of transoral incisionless fundoplication as a new technique in a tertiary care center

  • Shivanand Bomman;Sofya Malashanka;Adil Ghafoor;David J. Sanders;Shayan Irani;Richard A. Kozarek;Andrew Ross;Michal Hubka;Rajesh Krishnamoorthi
    • Clinical Endoscopy
    • /
    • v.55 no.5
    • /
    • pp.630-636
    • /
    • 2022
  • Background/Aims: Transoral incisionless fundoplication (TIF) is an accepted anatomic treatment for gastroesophageal reflux disease in selected patients. In this report, we analyze our institution's programmatic allocation of resources during the safe implementation of TIF as a new procedure. Methods: A retrospective analysis of all patients who underwent TIF from January 2020 to February 2021 at our institution was performed. The process of initially allocating the operating room (OR) with overnight admission and postoperative esophagram for added safety, and subsequently transitioning TIF to the endoscopy suite (ES) as an outpatient procedure was described. Patient safety and outcomes were evaluated during transition. Results: Thirty patients who underwent TIF were identified. The mean age was 51.2±16.0 years. TIF was performed in an OR in nine patients (30%) and 21 (70%) in the ES. All the OR patients were admitted overnight and had routine esophagogram. In contrast, four (19%) from the ES group required clinically-indicated admission and three (14.2%) required esophagram. The mean procedure duration was significantly lower in the ES group (65.7 min vs. 84 min, p=0.02). Conclusions: A stepwise, resource-efficient process was described that allowed safe initiation of TIF as a new technique and its effective transition to a fully outpatient procedure.

Colorectal Cancer Screening with Computed Tomography Colonography: Single Region Experience in Kazakhstan

  • Jandos Amankulov;Dilyara Kaidarova;Zhamilya Zholdybay;Marianna Zagurovskaya;Nurlan Baltabekov;Madina Gabdullina;Akmaral Ainakulova;Dias Toleshbayev;Alexandra Panina;Elvira Satbayeva;Zhansaya Kalieva
    • Clinical Endoscopy
    • /
    • v.55 no.1
    • /
    • pp.101-112
    • /
    • 2022
  • Background/Aims: The aim of our study was to determine the efficacy of computed tomography colonography (CTC) in screening for colorectal cancer (CRC). Methods: A total of 612 females and 588 males aged 45 to 75 years were enrolled in CTC screening. CTC was performed following standard bowel preparation and colonic insufflation with carbon dioxide. The main outcomes were the detection rate of CRC and advanced adenoma (AA), prevalence of colorectal lesions in relation to socio-demographic and health factors, and overall diagnostic performance of CTC. Results: Overall, 56.5% of the 1,200 invited subjects underwent CTC screening. The sensitivity for CRC and AA was 0.89 and 0.97, respectively, while the specificity was 0.71 and 0.99, respectively. The prevalence of CRC and AA was 3.0% (18/593) and 7.1% (42/593), respectively, with the highest CRC prevalence in the 66-75 age group (≥12 times; odds ratio [OR], 12.11; 95% confidence interval [CI], 4.45-32.92). CRC and AA prevalence were inversely correlated with Asian descent, physical activity, and negative fecal immunochemical test results (OR=0.43; 95% CI, 0.22-0.83; OR=0.16; 95% CI, 0.04-0.68; OR=0.5; 95% CI, 0.07-3.85, respectively). Conclusions: Our study revealed high accuracy of CTC in diagnosing colonic neoplasms, good compliance with CTC screening, and high detection rate of CRC.