• 제목/요약/키워드: Endoscopic ultrasonography (EUS)

검색결과 29건 처리시간 0.022초

Quality indicators of endoscopic ultrasound in the pancreatobiliary system: a brief review of current guidelines

  • Sung Yong Han;Hyung Ku Chon;Seong-Hun Kim;Sang Hyub Lee
    • Clinical Endoscopy
    • /
    • 제57권2호
    • /
    • pp.158-163
    • /
    • 2024
  • Since its development, the use of endoscopic ultrasonography (EUS) in the pancreas and the biliary tract has become increasingly important. The accuracy of EUS varies depending on the experience of the endoscopist. Hence, quality control measures using appropriate indicators are required to reduce these variations. American Society for Gastrointestinal Endoscopy and European Society of Gastrointestinal Endoscopy have announced the EUS quality indicators. Here, we reviewed the quality indicators of the EUS procedure in the current published guidelines.

Medical disputes related to advanced endoscopic procedures with endoscopic retrograde cholangiopancreatography or endoscopic ultrasonography for the management of pancreas and biliary tract diseases

  • Yoon Suk Lee;Jae-Young Jang;Jun Yong Bae;Eun Hye Oh;Yehyun Park;Yong Hwan Kwon;Jeong Eun Shin;Jun Kyu Lee;Tae Hee Lee;Chang Nyol Paik
    • Clinical Endoscopy
    • /
    • 제56권4호
    • /
    • pp.499-509
    • /
    • 2023
  • Background/Aims: This study aimed to evaluate the characteristics of endoscopic retrograde cholangiopancreatography (ERCP) or endoscopic ultrasonography (EUS)-related adverse events (AEs) that eventually lead to medical disputes or claims on medical professional liability. Methods: Medical disputes for ERCP/EUS-related AEs filed in the Korea Medical Dispute Mediation and Arbitration Agency between April 2012 and August 2020 were evaluated using corresponding medical records. AEs were categorized into three sections: procedure-related, sedation-related, and safety-related AEs. Results: Among a total of 34 cases, procedure-related AEs were 26 (76.5%; 12 duodenal perforations, 7 post-ERCP pancreatitis, 5 bleedings, 2 perforations combined with post-ERCP pancreatitis); sedation-related AEs were 5 (14.7%; 4 cardiac arrests, 1 desaturation), and safety-related AEs were 3 (8.8%; 1 follow-up loss for stent removal, 1 asphyxia, 1 fall). Regarding clinical outcomes, 20 (58.8%) were fatal and eventually succumbed to AEs. For the types of medical institutions, 21 cases (61.8%) occurred at tertiary or academic hospitals, and 13 (38.2%) occurred at community hospitals. Conclusions: The ERCP/EUS-related AEs filed in Korea Medical Dispute Mediation and Arbitration Agency showed distinct features: duodenal perforation was the most frequent AE, and clinical outcomes were fatal, resulting in at least more than permanent physical impairment.

Diagnostic Value of Endoscopic Ultrasonography for Common Bile Duct Dilatation without Identifiable Etiology Detected from CrossSectional Imaging

  • Nonthalee Pausawasdi;Penprapai Hongsrisuwan;Lubna Kamani;Kotchakon Maipang;Phunchai Charatcharoenwitthaya
    • Clinical Endoscopy
    • /
    • 제55권1호
    • /
    • pp.122-127
    • /
    • 2022
  • Background/Aims: Endoscopic ultrasonography (EUS) is warranted when cross-sectional imaging demonstrates common bile duct (CBD) dilatation without identifiable causes. This study aimed to assess the diagnostic performance of EUS in CBD dilatation of unknown etiology. Methods: Retrospective review of patients with dilated CBD without definite causes undergoing EUS between 2012 and 2017. Results: A total of 131 patients were recruited. The mean age was 63.2±14.1 years. The most common manifestation was abnormal liver chemistry (85.5%). The mean CBD diameter was 12.2±4.1 mm. The area under the receiver operating characteristic curve (AUROC) of EUS-identified pathologies, including malignancy, choledocholithiasis, and benign biliary stricture (BBS), was 0.98 (95% confidence interval [CI], 0.95-1.00). The AUROC of EUS for detecting malignancy, choledocholithiasis, and BBS was 0.91 (95% CI, 0.85-0.97), 1.00 (95% CI, 1.00-1.00), and 0.93 (95% CI, 0.87-0.99), respectively. Male sex, alanine aminotransferase ≥3× the upper limit of normal (ULN), alkaline phosphatase ≥3× the ULN, and intrahepatic duct dilatation were predictors for pathological obstruction, with odds ratios of 5.46 (95%CI, 1.74-17.1), 5.02 (95% CI, 1.48-17.0), 4.63 (95% CI, 1.1-19.6), and 4.03 (95% CI, 1.37-11.8), respectively. Conclusions: EUS provides excellent diagnostic value in identifying the etiology of CBD dilatation detected by cross-sectional imaging.

Covered self-expandable metallic stents versus plastic stents for endoscopic ultrasound-guided hepaticogastrostomy in patients with malignant biliary obstruction

  • Taro Shibuki;Kei Okumura;Masanari Sekine;Ikuhiro Kobori;Aki Miyagaki;Yoshihiro Sasaki;Yuichi Takano;Yusuke Hashimoto
    • Clinical Endoscopy
    • /
    • 제56권6호
    • /
    • pp.802-811
    • /
    • 2023
  • Background/Aims: Covered self-expandable metallic stents (cSEMS) have become popular for endoscopic ultrasound-guided hepaticogastrostomy with transmural stenting (EUS-HGS). We compared the time to recurrent biliary obstruction (TRBO), complications, and reintervention rates between EUS-HGS using plastic stent (PS) and cSEMS in patients with unresectable malignancies at multicenter institutions in Japan. Methods: Patients with unresectable malignant biliary obstruction who underwent EUS-HGS between April 2015 and July 2020 at any of the six participating facilities were enrolled. Primary endpoint: TRBO; secondary endpoints: rate of complications other than recurrent biliary obstruction and technical success rate of reintervention were evaluated. Results: PS and cSEMS were used for EUS-HGS in 109 and 43 patients, respectively. The TRBO was significantly longer in the cSEMS group than in the PS group (646 vs. 202 days). Multivariate analysis identified two independent factors associated with a favorable TRBO: combined EUS-guided antegrade stenting with EUS-HGS and the use of cSEMS. No significant difference was observed in the rate of complications other than recurrent biliary obstruction between the two groups. The technical success rate of reintervention was 85.7% for PS and 100% for cSEMS (p=0.309). Conclusions: cSEMS might be a better option for EUS-HGS in patients with unresectable malignancies, given the longer TRBO.

Safety and efficacy of novel oblique-viewing scope for B2-endoscopic ultrasound-guided hepaticogastrostomy

  • Sho Ishikawa;Kazuo Hara;Nozomi Okuno;Nobumasa Mizuno;Shin Haba;Takamichi Kuwahara;Yasuhiro Kuraishi;Takafumi Yanaidani;Masanori Yamada;Tsukasa Yasuda;Toshitaka Fukui;Teru Kumagi;Yoichi Hiasa
    • Clinical Endoscopy
    • /
    • 제57권4호
    • /
    • pp.527-533
    • /
    • 2024
  • Background/Aims: Endoscopic ultrasound (EUS)-guided hepaticogastrostomy (EUS-HGS) performed at the intrahepatic bile duct segment 3 (B3) is widely used for biliary drainage. Although performing post-puncture procedures is easier in the intrahepatic bile duct segment 2 (B2) when using a conventional oblique-viewing (OV) EUS scope, this method may cause transesophageal puncture and severe adverse events. We evaluated the safety and efficacy of B2 puncture using a novel OV-EUS scope. Methods: In this single-center retrospective study, we prospectively enrolled and collected data from 45 patients who consecutively underwent EUS-HGS procedures with a novel OV-EUS scope between September 2021 and December 2022 at our cancer center. Results: The technical success rates of B2-EUS-HGS and EUS-HGS were 93.3% (42/45) and 97.8% (44/45), respectively. The early adverse event rate was 8.9% (4/45) with no cases of scope changes or transesophageal punctures. The median procedure time was 13 minutes (range, 5-30). Conclusions: B2-EUS-HGS can be performed safely with the novel EG-740UT (Fujifilm) OV-scope without transesophageal puncture and with a high success rate. B2-EUS-HGS using this novel OV scope may be the preferred strategy for EUS-HGS.

Outcomes of Endoscopic Drainage in Children with Pancreatic Fluid Collections: A Systematic Review and Meta-Analysis

  • Nabi, Zaheer;Talukdar, Rupjyoti;Lakhtakia, Sundeep;Reddy, D. Nageshwar
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제25권3호
    • /
    • pp.251-262
    • /
    • 2022
  • Purpose: Endoscopic drainage is an established treatment modality for adult patients with pancreatic fluid collections (PFCs). Available data regarding the efficacy and safety of endoscopic drainage in pediatric patients are limited. In this systematic review and meta-analysis, we aimed to analyze the outcomes of endoscopic drainage in children with PFCs. Methods: A literature search was performed in Embase, PubMed, and Google Scholar for studies on the outcomes of endoscopic drainage with or without endoscopic ultrasonography (EUS) guidance in pediatric patients with PFCs from inception to May 2021. The study's primary objective was clinical success, defined as resolution of PFCs. The secondary outcomes included technical success, adverse events, and recurrence rates. Results: Fourteen studies (187 children, 70.3% male) were included in this review. The subtypes of fluid collection included pseudocysts (60.3%) and walled-off necrosis (39.7%). The pooled technical success rates in studies where drainage of PFCs were performed with and without EUS guidance were 95.3% (95% confidence interval [CI], 89.6-98%; I2=0) and 93.9% (95% CI, 82.6-98%; I2=0), respectively. The pooled clinical success after one and two endoscopic interventions were 88.7% (95% CI, 82.7-92.9%; I2=0) and 92.3% (95% CI, 87.4-95.4%; I2=0), respectively. The pooled rate of major adverse events was 6.3% (95% CI, 3.3-11.4%; I2=0). The pooled rate of recurrent PFCs after endoscopic drainage was 10.4% (95% CI, 6.1-17.1%; I2=0). Conclusion: Endoscopic drainage is safe and effective in children with PFCs. However, future studies are required to compare endoscopic and EUS-guided drainage of PFCs in children.

Stereomicroscopic on-site evaluation in endoscopic ultrasound-guided tissue acquisition of upper gastrointestinal subepithelial lesions

  • Seigo Nakatani;Kosuke Okuwaki;Masafumi Watanabe;Hiroshi Imaizumi;Tomohisa Iwai;Takaaki Matsumoto;Rikiya Hasegawa;Hironori Masutani;Takahiro Kurosu;Akihiro Tamaki;Junro Ishizaki;Ayana Ishizaki;Mitsuhiro Kida;Chika Kusano
    • Clinical Endoscopy
    • /
    • 제57권1호
    • /
    • pp.89-95
    • /
    • 2024
  • Background/Aims: In stereomicroscopic sample isolation processing, the cutoff value (≥4 mm) of stereomicroscopically visible white cores indicates high diagnostic sensitivity. We aimed to evaluate endoscopic ultrasound-guided tissue acquisition (EUS-TA) using a simplified stereomicroscopic on-site evaluation of upper gastrointestinal subepithelial lesions (SELs). Methods: In this multicenter prospective trial, we performed EUS-TA using a 22-gauge Franseen needle in 34 participants with SELs derived from the upper gastrointestinal muscularis propria, requiring pathological diagnosis. The presence of stereomicroscopically visible white core (SVWC) in each specimen was assessed using stereomicroscopic on-site evaluation. The primary outcome was EUS-TA's diagnostic sensitivity with stereomicroscopic on-site evaluation based on the SVWC cutoff value (≥4 mm) for malignant upper gastrointestinal SELs. Results: The total number of punctures was 68; 61 specimens (89.7%) contained stereomicroscopically visible white cores ≥4 mm in size. The final diagnoses were gastrointestinal stromal tumor, leiomyoma, and schwannoma in 76.5%, 14.7%, and 8.8% of the cases, respectively. The sensitivity of EUS-TA with stereomicroscopic on-site evaluation based on the SVWC cutoff value for malignant SELs was 100%. The per-lesion accuracy of histological diagnosis reached the highest level (100%) at the second puncture. Conclusions: Stereomicroscopic on-site evaluation showed high diagnostic sensitivity and could be a new method for diagnosing upper gastrointestinal SELs using EUS-TA.

Accuracy of Endoscopic Ultrasonography for Determination of Tumor Invasion Depth in Gastric Cancer

  • Razavi, Seyed Mohsen;Khodadost, Mahmoud;Sohrabi, Masoudreza;Keshavarzi, Azam;Zamani, Farhad;Rakhshani, Naser;Ameli, Mitra;Sadeghi, Reza;Hatami, Khadijeh;Ajdarkosh, Hossein;Golmahi, Zeynab;Ranjbaran, Mehdi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권8호
    • /
    • pp.3141-3145
    • /
    • 2015
  • Background: Gastric cancer (GC) is one the common lethal cancers in Iran. Detection of GC in the early stages would assesses to improve the survival of patients. In this study, we attempt to evaluate the accuracy of EUS in detection depth of invasion of GC among Iranian Patients. Materials and Methods: This study is a retrospective study of patients with pathologically confirmed GC. They underwent EUS before initiating the treatment. The accuracy of EUS and agreement between the two methods was evaluated by comparing pre treatment EUS finding with post operative histopathological results. Results: The overall accuracy of EUS for T and N staging was 67.9% and 75.47, respectively. Underestimation and overestimation was seen in 22 (14.2%) and 40 (25.6%) respectively. The EUS was more accurate in large tumors and the tumors located in the middle and lower parts of the stomach. The EUS was more sensitive in T3 staging. The values of weighted Kappa from the T and N staging were 0.53 and 0.66, respectively. Conclusions: EUS is a useful modality for evaluating the depth of invasion of GC. The accuracy of EUS was higher if the tumor was located in the lower parts of the stomach and the size of the tumor was more than 3 cm. Therefore, judgments made upon other criteria evaluated in this study need to be reconsidered.

Comparison of diagnostic performances of slow-pull suction and standard suction in endoscopic ultrasound-guided fine needle biopsy for gastrointestinal subepithelial tumors

  • Joon Seop Lee;Chang Min Cho;Yong Hwan Kwon;An Na Seo;Han Ik Bae;Man-Hoon Han
    • Clinical Endoscopy
    • /
    • 제55권5호
    • /
    • pp.637-644
    • /
    • 2022
  • Background/Aims: Endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) is integral to the diagnosis of gastrointestinal (GI) subepithelial tumors (SETs). The impact of different EUS-FNB tissue sampling techniques on specimen adequacy and diagnostic accuracy in SETs has not been fully evaluated. This study aimed to compare the diagnostic outcomes of slow-pull (SP) and standard suction (SS) in patients with GI SETs. Methods: In this retrospective comparative study, 54 patients were enrolled. Medical records were reviewed for location and size of the target lesion, FNB needle type/size, technical order, specimen adequacy, diagnostic yield, and adverse events. The acquisition rate of adequate specimens and diagnostic accuracy were compared according to EUS-FNB techniques. Results: The mean lesion size was 42.6±36.4 mm, and most patients were diagnosed with GI stromal tumor (75.9%). The overall diagnostic accuracies of the SP and SS techniques were 83.3% and 81.5%, respectively (p=0.800). The rates of obtaining adequate core tissue were 79.6% and 75.9%, respectively (p=0.799). No significant clinical factors affected the rate of obtaining adequate core tissue, including lesion location and size, FNB needle size, and final diagnosis. Conclusions: SP and SS had comparable diagnostic accuracies and adequate core tissue acquisition for GI SETs via EUS-FNB.

Bispectral index-guided propofol sedation during endoscopic ultrasonography

  • Ayana Okamoto;Ken Kamata;Takeshi Miyata;Tomoe Yoshikawa;Rei Ishikawa;Tomohiro Yamazaki;Atsushi Nakai;Shunsuke Omoto;Kosuke Minaga;Kentaro Yamao;Mamoru Takenaka;Yasutaka Chiba;Toshiharu Sakurai;Naoshi Nishida;Masayuki Kitano;Masatoshi Kudo
    • Clinical Endoscopy
    • /
    • 제55권4호
    • /
    • pp.558-563
    • /
    • 2022
  • Background/Aims: Bispectral index (BIS) monitors process and display electroencephalographic data are used to assess the depth of anesthesia. This study retrospectively evaluated the usefulness of BIS monitoring during endoscopic ultrasonography (EUS). Methods: This study included 725 consecutive patients who underwent EUS under sedation with propofol. BIS monitoring was used in 364 patients and was not used in 361. The following parameters were evaluated: (1) median dose of propofol; (2) respiratory and circulatory depression; (3) occurrence of body movements; (4) awakening score >8 at the time; and (5) awakening score 2 hours after leaving the endoscopy room. Results: The BIS group received a significantly lower median dose of propofol than the non-BIS group (159.2 mg vs. 167.5 mg; p=0.015) in all age groups. For patients aged ≥75 years, the reduction in heart rate was significantly lower in the BIS group than in the non-BIS group (1.2% vs. 9.1%; p=0.023). Moreover, the occurrence of body movements was markedly lower in the BIS group than in the non-BIS group (8.5% vs. 39.4%; p<0.001). Conclusions: During EUS examination, BIS monitoring is useful for maintaining a constant depth of anesthesia, especially in patients 75 years of age or older.