• Title/Summary/Keyword: Endoscopic suturing

Search Result 8, Processing Time 0.02 seconds

Endoscopic and Laparoscopic Full-Thickness Resection of Endophytic Gastric Submucosal Tumors Very Close to the Esophagogastric Junction

  • Kwon, Oh Kyoung;Yu, Wansik
    • Journal of Gastric Cancer
    • /
    • v.15 no.4
    • /
    • pp.278-285
    • /
    • 2015
  • Purpose: Gastric submucosal tumors (SMTs) located very close to the esophagogastric junction (EGJ) are a challenge for gastric surgeons. Therefore, this study reports on the experience of using endoscopic and laparoscopic full-thickness resection (ELFR) with laparoscopic two-layer suturing in such tumors. Materials and Methods: Six patients with gastric SMTs very close to the EGJ underwent ELFR with laparoscopic two-layer suturing at Kyungpook National University Medical Center. With the patient under general anesthesia, the lesser curvature and posterior aspect adjacent to the EGJ were meticulously dissected and visualized using a laparoscopic approach. A partially circumferential full-thickness incision at the distal margin of the tumor was then made using an endoscopic approach under laparoscopic guidance. The SMT was resected using laparoscopic ultrasonic shears, and the gastric wall was closed using two-layer suturing. Thereafter, the patency and any leakage were checked through endoscopy. Results: All the ELFR procedures with laparoscopic two-layer suturing were performed successfully without an open conversion. The mean operation time was $139.2{\pm}30.9$ minutes and the blood loss was too minimal to be measured. The tumors from four patients were leiomyomas, while the tumors from the other two patients were gastrointestinal stromal tumors with clear resection margins. All the patients started oral intake on the third postoperative day. There was no morbidity or mortality. The mean hospital stay was $7.7{\pm}0.8$ days. Conclusions: ELFR with laparoscopic two-layer suturing is a safe treatment option for patients with an SMT close to the EGJ, as major resection of the stomach is avoided.

Non-exposure Simple Suturing Endoscopic Full-thickness Resection with Sentinel Basin Dissection in Patients with Early Gastric Cancer: the SENORITA 3 Pilot Study

  • Eom, Bang Wool;Kim, Chan Gyoo;Kook, Myeong-Cherl;Yoon, Hong Man;Ryu, Keun Won;Kim, Young-Woo;Rho, Ji Yoon;Kim, Young-Il;Lee, Jong Yeul;Choi, Il Ju
    • Journal of Gastric Cancer
    • /
    • v.20 no.3
    • /
    • pp.245-255
    • /
    • 2020
  • Purpose: Recently, non-exposure simple suturing endoscopic full-thickness resection (NESS-EFTR) was developed to prevent tumor exposure to the peritoneal cavity. This study aimed to evaluate the feasibility of NESS-EFTR with sentinel basin dissection for early gastric cancer (EGC). Materials and Methods: This was the prospective SENORITA 3 pilot. From July 2017 to January 2018, 20 patients with EGC smaller than 3 cm without an absolute indication for endoscopic submucosal dissection were enrolled. The sentinel basin was detected using Tc99m-phytate and indocyanine green, and the NESS-EFTR procedure was performed when all sentinel basin nodes were tumor-free on frozen pathologic examination. We evaluated the complete resection and intraoperative perforation rates as well as the incidence of postoperative complications. Results: Among the 20 enrolled patients, one dropped out due to large tumor size, while another underwent conventional laparoscopic gastrectomy due to metastatic sentinel lymph nodes. All NESS-EFTR procedures were performed in 17 of the 18 other patients (94.4%) without conversion, and the complete resection rate was 83.3% (15/18). The intraoperative perforation rate was 27.8% (5/18), and endoscopic clipping or laparoscopic suturing or stapling was performed at the perforation site. There was one case of postoperative complications treated with endoscopic clipping; the others were discharged without any event. Conclusions: NESS-EFTR with sentinel basin dissection is a technically challenging procedure that obtains safe margins, prevents intraoperative perforation, and may be a treatment option for EGC after additional experience.

Endoscopic Treatment for Gastric Subepithelial Tumor

  • Chan Gyoo Kim
    • Journal of Gastric Cancer
    • /
    • v.24 no.1
    • /
    • pp.122-134
    • /
    • 2024
  • Most gastric subepithelial tumors (SETs) are asymptomatic and are often incidentally discovered during endoscopic procedures conducted for unrelated reasons. Although surveillance is sufficient for the majority of gastric SETs, certain cases necessitate proactive management. Laparoscopic wedge resection, although a viable treatment option, has its limitations, particularly in cases where SETs (especially those with intraluminal growth) are not visualized on the peritoneal side. Recent advances in endoscopic instruments and technology have paved the way for the feasibility of endoscopic resection of SETs. Several promising endoscopic techniques have emerged for gastric SET resection, including submucosal tunneling endoscopic resection, endoscopic full-thickness resection (EFTR), laparoscopic and endoscopic cooperative surgery (LECS), and non-exposure EFTR (non-exposed endoscopic wall-inversion surgery and non-exposure simple suturing EFTR). This study aimed to discuss the indications, methods, and outcomes of endoscopic therapy for gastric SETs. In addition, a simplified diagram of the category of SETs according to the therapeutic indications and an algorithm for the endoscopic management of SET is suggested.

Successive Suturing Device For Endoscope Utilizing Beads (비드를 이용한 내시경용 연속봉합기구)

  • 조문기;이창양;홍대희;전훈재;이규백
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.804-808
    • /
    • 2004
  • This paper deals with the designing of instrument for achieving surgical operation in the stomach and gullet using endoscope channel. The method used herein was to provide beads to knot suturing thread automatically. Following design rules were applied : 1) that instrument must be designed to enable surgical operator to stitch successively by only simple handling 2) that instrument must be designed to minimize insertion and extraction of endoscope. The main result from the experiment with animal stomach was that the surgical operation time was reduced and successive suture was available. Considering the requirement of operator‘s highly trained skills and the discomfort of patient in traditional suture process, the proposed design is expected to markedly improve the endoscopic suturing performance.

  • PDF

Endoscopic Intervention for Anastomotic Leakage After Gastrectomy

  • Ji Yoon Kim;Hyunsoo Chung
    • Journal of Gastric Cancer
    • /
    • v.24 no.1
    • /
    • pp.108-121
    • /
    • 2024
  • Anastomotic leaks and fistulas are significant complications of gastric surgery that potentially lead to increased postoperative morbidity and mortality. Surgical intervention is reserved for cases with severe symptoms or hemodynamic instability; however, surgery carries a higher risk of complications. With advancements in endoscopic treatment options, endoscopic approaches have emerged as the primary choice for managing these complications. Endoscopic clipping is a traditional method comprising 2 main categories: through-the-scope clips and over-the-scope clips. Through-the-scope clips are user friendly and adaptable to various clinical scenarios, whereas over-the-scope clips can close larger defects. Another promising approach is endoscopic stent insertion, which has shown a high success rate for leak closure, although vigilant monitoring is required to monitor stent migration. Infection control is essential in post-surgical leakage cases, and endoscopic internal drainage provides a relatively safe and noninvasive means to manage fluids, contributing to infection control and wound healing promotion. Endoscopic suturing offers full-thickness wound closure, but requires additional training and endoscopic versatility. As a promising tool, endoscopic vacuum therapy potentially surpasses stent therapy by draining inflammatory materials and closing defects. Furthermore, the use of tissue sealants, such as fibrin glue and cyanoacrylate, has been reported to be effective in selected situations. The choice of endoscopic device should be tailored to individual cases and specific patient conditions, with careful consideration of the nature of the defect. Further extensive studies involving larger patient populations are required to provide more robust evidence on the efficacy of endoscopic approach in managing post-gastric anastomotic leaks.

A Novel Technique of Hand-Sewn Purse-String Suturing by Double Ligation Method (DLM) for Intracorporeal Circular Esophagojejunostomy

  • Takayama, Yuichi;Kaneoka, Yuji;Maeda, Atsuyuki;Fukami, Yasuyuki;Takahashi, Takamasa;Uji, Masahito
    • Journal of Gastric Cancer
    • /
    • v.19 no.3
    • /
    • pp.290-300
    • /
    • 2019
  • Purpose: The optimal method for intracorporeal esophagojejunostomy remains unclear because a purse-string suture for fixing the anvil into the esophagus is difficult to perform with a laparoscopic approach. Therefore, this study aimed to evaluate our novel technique to fix the anvil into the esophagus. Materials and Methods: This retrospective study included 202 patients who were treated at our institution with an intracorporeal circular esophagojejunostomy in a laparoscopy-assisted total gastrectomy with a Roux-en-Y reconstruction (166 cases) or a laparoscopy-assisted proximal gastrectomy with jejunal interposition (36 cases). After incising 3/4 of the esophageal wall, a hand-sewn purse-string suture was placed on the esophagus. Next, the anvil head of a circular stapler was introduced into the esophagus. Finally, the circular esophagojejunostomy was performed laparoscopically. The clinical characteristics and surgical outcomes were evaluated and compared with those of other methods. Results: The average operation time was 200.3 minutes. The average hand-sewn purse-string suturing time was 6.4 minutes. The overall incidence of postoperative complications (Clavien-Dindo classification grade ${\geq}II$) was 26%. The number of patients with an anastomotic leakage and stenosis at the esophagojejunostomy site were 4 (2.0%) and 12 (6.0%), respectively. All patients with stenosis were successfully treated by endoscopic balloon dilatation. There was no mortality. Regarding the materials and devices for anvil fixation, only 1 absorbable thread was needed. Conclusions: Our procedure for hand-sewn purse-string suturing with the double ligation method is simple and safe.

Laparoscopic Rectovaginal Septal Repair without Mesh for Anterior Rectocele

  • Kwak, Han Deok;Ju, Jae Kyun
    • Journal of Minimally Invasive Surgery
    • /
    • v.21 no.4
    • /
    • pp.177-179
    • /
    • 2018
  • A rectocele with a weakened rectovaginal septum can be repaired with various surgical techniques. We performed laparoscopic posterior vaginal wall repair and rectovaginal septal reinforcement without mesh using a modified transperineal approach. A 63-year-old woman with outlet dysfunction constipation complained of lower pelvic pressure and sense of heaviness for 30 years. Initial defecography showed an anterior rectocele with a 45-mm anterior bulge and perineal descent. Laparoscopic procedures included peritoneal and rectovaginal septal dissection directed toward the perineal body, rectovaginal septal suturing, and peritoneal closure. The patient started a soft diet the following day and was discharged on the 5th postoperative day without any complications. The patient had no dyschezia or dyspareunia, and no problem with bowel function; 3-month follow-up defecography showed a decrease in bulging to 18 mm. Laparoscopic posterior vaginal wall and rectovaginal septal repair is safe and feasible for treatment of a rectocele, and enables early recovery.

A Treatment Case of Endoscopic Removal of Left Ventricular Thrombus, During Coronary Artery Bypass Graft

  • Park, Hyun-Seok;Ryu, Se-Min;Cho, Seong-Joon;Park, Sung-Min;Lim, Sun-Hye
    • Journal of Chest Surgery
    • /
    • v.47 no.4
    • /
    • pp.434-436
    • /
    • 2014
  • Left ventricular thrombus is a common complication related to acute myocardial infarction. Removing this with an incision of the free wall of the left ventricle may cause fatal cardiac dysfunction or arrhythmias. Furthermore, performing incision and suture on the fragile myocardium of an acute myocardial infarction patient may cause serious bleeding complications. If there is a patient with left ventricular thrombus who needs thoracotomy for another reason, the case is attempted with the thought that if effective intraventricular visualization and manipulation can be done, fatalities caused by incision and suture may be reduced. For patients undergoing cardiopulmonary bypass, if intracardiac manipulation is required, an endoscope can be used, and given the potential complications after the incision and suturing of the infarcted tissue, the benefits are deemed sufficient.