The structures and energies of p-tert-butylcalix[5]crown-6-ether (1) and its alkylammonium complexes have been calculated by DFT B3LYP/6-31G(d,p) method. We have studied the binding sites of these host-guest complexes focusing on the p-tert-butylcalix[5]arene pocket (endo) or the crown-6-ether moiety (exo) of 1. The smaller alkylammonium cations have the better complexation efficiency with p-tert-butylcalix[5]crown-6- ether than the bulkier alkylammonium ions. For the sec- and tert-butylammonium ions, the hydrogen-bond distances of the exo-complexes are shorter, therefore, stronger than the endo-cases. This DFT calculated result is in parallel with the trend of the experimental association constants of the branched butylammonium ions.
Apical surgery cuts off the apical root and the crown-to-root ratio becomes unfavorable. Crown-to-root ratio has been applied to periodontally compromised teeth. Apical root resection is a different matter from periodontal bone loss. The purpose of this paper is to review the validity of crown-to-root ratio in the apically resected teeth. Most roots have conical shape and the root surface area of coronal part is wider than apical part of the same length. Therefore loss of alveolar bone support from apical resection is much less than its linear length.The maximum stress from mastication concentrates on the cervical area and the minimum stress was found on the apical 1/3 area. Therefore apical root resection is not so harmful as periodontal bone loss. Osteotomy for apical resection reduces longitudinal width of the buccal bone and increases the risk of endo-perio communication which leads to failure. Endodontic microsurgery is able to realize 0 degree or shallow bevel and precise length of root resection, and minimize the longitudinal width of osteotomy. The crown-to-root ratio is not valid in evaluating the prosthodontic prognosis of the apically resected teeth. Accurate execution of endodontic microsurgery to preserve the buccal bone is essential to avoid endo-perio communication.
이 실험의 목적은 근관 내에 충전된 수산화칼슘의 제거 시 치근단 1/3에서 기존의 근관세정법과 $EndoActivator^{(R)}$, $EndoVac^{(R)}$ system의 세정 효율을 비교하고, 근관 세정 중 치근단공 개방 확인의 영향에 대해 평가하고자 함이다. 60개의 단근치를 사용하였고 ISO #35까지 근관성형 후 수산화칼슘을 충전하였다. 근관 세정법과 치근단공 개방 확인 유무에 따라 6개 실험군으로 나누어 세정하였다. 실험 치아를 양분하여 치근단 3 mm에서 근관 면적에 대한 잔존 수산화칼슘 면적의 백분율을 측정하였다. 실험결과 $EndoActivator^{(R)}$, $EndoVac^{(R)}$군이 기존의 근관 세정법 군에 비해 유의하게 높은 제거효율을 나타냈으며 (p<0.05), 치근단공 개방 확인 유무에 따른 유의한 차이는 나타나지 않았다. 이 실험 결과에 따르면 기존의 근관세정법으로 효과적인 세정이 불가능했던 근관의 치근단 1/3부위에서 $EndoActivator^{(R)}$, $EndoVac^{(R)}$ system과 같은 근관 세정법이 효과적인 대안이 될 수 있다는 결론을 얻었다.
이 실험의 목적은 $EndoVac^{(R)}$과 $EndoActivator^{(R)}$를 이용한 근관세척시 근관 내 접종된 Enterococcus faecalis의 제거 효율을 기존의 irrigation needle을 이용한 방법과 비교 평가하고자 함이다. 발거된 70개의 단근치를 사용하였으며 .04 taper ProFile #40까지 근관형성 후 치아를 멸균하고 근관에 E. faecalis를 접종하고 배양하였다. 치아는 근관세척 방법에 따라 20개씩 3개의 실험군과 2개의 대조군으로 나누었다. 2.5% 치아염소산나트륨을 사용하여 근관세척 시행 후 일차 표본을 채취하였고, 다시 근관 내에 배양액을 채우고 24시간 동안 배양 후 이차 표본을 채취하였다. 표본은 colony forming units (CFU) 값을 얻기 위해 BHI agar plate에 배양하였다. 일차 표본 결과에서는 모든 실험치아 중 기존의 근관세척 방법을 이용한 하나의 근관에서 양성 배양을 보였다. 이차 표본 결과에서는 $EndoVac^{(R)}$ 실험군에서 가장 적은 양성 배양을 보였으며, 기존의 근관세척 방법과 비교시 통계적으로 유의한 차이를 보였다. 실험 결과에 따르면 $EndoVac^{(R)}$은 근관 내 접종된 E. faecalis의 제거에 있어 기존의 근관세척 방법보다 더 좋은 효율을 보였다.
Stable molecular isomers were calculated for the azobenzene crown ether p-tert-butylcalix[4]arene (1) in the host and their alkali-metal-ion complexes. The structures of two distinct isomers (cis and trans) have been optimized using DFT B3LYP/6-31G(d,p) method. Trans isomer of 1 is found to be 11.69 kcal/mol more stable than cis analogue. For two different kinds of complexation mode, the alkali-metal-cation in the crown-ether moiety (exo) has much better complexation efficiency than in the benzene-rings (endo) pocket for both isomers of 1. Sodium ion has much better complexation efficiency than potassium ion in all kinds of complexation mode with host 1. The Na+ complexation efficiency of the trans-complex (1) in the exo-binding mode is 8.24 kcal/mol better than cis-exo analogue.
본 연구의 목적은 근관치료 된 치아를 구조와 물성이 다른 post와 core 그리고 전장관으로 수복한 후 과도한 교합하중을 가했을 때 치아에 나타나는 응력분포를 조사하기 위함이다. 발치 된 상악 제2소구치를 micro-CT로 단층촬영하고 3D Doctor로 윤곽선을 추출한 다음 HyperMesh Ver. 6으로 삼차원 치아모형을 만들고 다음과 같은 세 가지 방법으로 수복한 유한요소모형을 제작하였다. 1) 스테인레스 스틸 포스트와 복합레진 코어 그리고 도재소부전장금관으로 수복한 모형. 2) fiber 포스트와 복합레진 코어 그리고 전부도재관으로 수복한 모형 3) 포스트, 코어와 전장관이 일체형인 간접복합레진 EndoCrown으로 수복한 모형 형성된 모형의 협측 또는 설측교두에 500N의 하중을 가하였으며 하중의 방향은 치아 장축에 대해 45도 이었다. 치관부와 치근부의 von Mises 응력을 ANSYS 9.0프로그램으로 분석한 결과 포스트와 코어의 형태보다는 전장관 재료의 탄성 계수가 근관치료된 상악 소구치의 응력분포를 좌우하였다. 치관부에서는 재료의 탄성계수가 높은 전 장관으로 수복한 모형이 낮은 응력분포를 보였다. 치근부에서는 재료의 탄성계수가 낮은 전 장관으로 수복한 모형 이 낮은 응력분포를 보였다.
Light detection and ranging (LIDAR) is one of the effective technologies for monitoring forest inventory, and importance of forestry is increasing because of its function as the sink of green house gases (GHG). This study aims at development of a methodology for better and more accurate estimation of physical parameters of individual trees by removing sudden drops of LIDAR data within a crown. Our study area is located in Aomori prefecture, the northern part of Honshu Island, with the dominant species of Japanese cedar. The results show practicality of our method in the usage of LIDAR data in the field of forest inventory.
이 연구의 목적은 Mtwo 전동 파일의 사용에 있어서 제조사가 제안한 single length technique과 crown-down technique의 근관성형효율과 안전성을 비교하고 Mtwo 전동 파일의 변형된 사용방법을 제안하고자 하는 것이다. 기구의 종류와 사용방법에 따라 60개의 레진 블록 근관 모형 (Endo Training Bloc; Benstply Maillefer, Ballaigues, Switzerland)을 세 군으로 나누어 20개씩 표본을 성형하였다. MT군은 Mtwo 파일 (VDW, Munich, Germany)을 제조사의 추천방법인 single length technique으로, MC군은 Mtwo 파일을 crown-down technique으로 형성하였고, 대조군인 PT군은 ProTaper (Denstply Maillefer, Ballaigues, Switzerland)를 사용하였다. 모든 기구는 250 r.p.m., torque 2.2 N로 고정한 전동 모터 (X-smart; Denstply Maillefer, Ballaigues, Switzerland)로 사용하였다. 근관 성형 후, 스캐너로 근관 형성 전후의 이미지를 채득하여 중첩 비교함으로써 근단부로부터 1, 2, 3, 4, 5, 6, 7, 8 mm 높이에서의 중심변위율을 산출하였다. 순수 기구조작 시간 및 기구조작 동안의 binding빈도를 기록하였다. 근관 성형 후, 레진 블록의 무게 감소를 측정하였고 근관 성형에 사용된 파일의 파절이나 변형 및 근관 성형 후 형태의 이상을 조사하였다. 세 실험군의 측정 및 산출된 자료를 일원배치 분산분석 및 Duncan's Multiple Range Test로 사후 검정을 시행하여 비교하였으며, Fisher's exact test으로 근관의 이형성, 기구의 변형 그리고 기구 binding 등 발생 빈도를 유의 확률 95%에서 통계 검정하였다. 그 결과는 다음과 같다. 1. 근관의 만곡도 감소, 중심변위율, 레진 블록의 무게 감소, 기구 변형 등은 세 군간에 유의한 차이가 없었다 (p > 0.05). 2. 기구 조작 시간은 보면 MT군과 MC군이 PT군보다 짧았다 (p < 0.05). 3. Elbow는 MT군이 MC군에서 PT군보다 더 많이 형성되었다 (p < 0.05). Ledge는 세 군 모두에서 나타나지 않았다. 4. 파일 binding 횟수는 MC군이 가장 적고 PT군이 가장 많았다 (p < 0.05). 이상의 결과를 볼 때, Mtwo 전동 파일을 crown-down technique으로 사용하는 것이 single length technique과 유사한 성형 효율을 보이면서도 더 안전할 것으로 추정된다.
I. Objectives The purpose of this study was to compare the shaping ability between the single length technique performed with Mtwo instruments (VDW, Munich, Germany) and the crown-down technique using K3 (SybronEndo, West Collins, CA, USA) and RaCe (FKG, La Chaux-de-Fonds, Switzerland) instruments. II. Materials & Methods Forty five curved canals in resin blocks were equally divided in to three groups. Group 1 (Mtwo) was instrumented used the full length of canal according to the manufacturer's instructions. The simulated canals was prepared to an instrument size of 35, 0.04 taper canal terminus. In group 2 (Race) and group 3 (K3) was instrumented in a crown-down manner and prepared to an instrument size of 30, 0.06 taper canal terminus. Pre- and post-instrumentation images were scanned and assessment of canal shape was completed with a computer image analysis program. Material removal was measured at 7 measuring points, beginning 1mm from the end point of preparation. Differenced of centering ratio were statistically analyzed using One-way ANOVA followed by Duncan's test. II. Results & Conclusion There was no significant difference on 1, 2, 3 and 7mm measuring point. At 4 and 5 measuring point, significant difference showed between the Mtow instruments and other two instruments. (p<0.05)
본 연구는 레진모형 만곡근관에서 여러 가지 엔진구동형 Ni-Ti 파일로 근관성형 후, 같은 경사도를 가진 수종의 거타퍼챠콘을 적용시 근관내 삽입깊이에 대해 비교, 분석해보고자 시행하였다. 레진 모형근관으로 J자의 근관형태가 재현된 ENDO-TRAINING BLOCK 50개를 사용하여 각각 10개씩 1) ProFile .04 taper #25, 2) ProFile .06 taper #25, 3) ProTaper F2, 4) HEROShaper .04 taper #25, 5) HEROShaper .06 taper #25 파일로 최종 근관성형 하였다. 거타퍼챠콘은 META (META Biomed, Korea), Sure-Endo(SUREDENT, Korea) 그리고 DiaDent(DiaDent Group International Inc., Canada)의 .04 및 .06 경사도의 콘을 사용하였으며 선택된 거타퍼챠콘의 직경 및 경사도를 측정하였다. ProFile과 HEROShaper로 성형한 레진블록에는사용된 Ni-Ti 파일의 경사도에 맞는 제조회사별 .04및 .06경사도의 거타퍼챠콘을 10개씩 근관에 적용하였으며, ProTaper로 성형한 레진블록에는 경사도와 무관하게 제조회사별 .04 및 .06 경사도의 거타퍼챠콘을 10개씩 적용하였다. 거타퍼챠콘을 근관내 적용한 상태에서 스캐너를 이용하여 이미지를 얻은 후 이미지 분석 프로그램을 사용하여 근첨에서 거타퍼챠콘 첨부까지의 거리를 측정하였고 다음의 결과를 얻었다. HEROShaper를 이용하여 근관성형 한 경우 ProFile 및 ProTaper보다 거타퍼챠콘의 근관내 적합성이 우수하게 나타났으며, 근관성형시 .04 taper HEROShaper로 근관성형 후에는 META 거타퍼챠콘 및 Sure-Endo 거타퍼챠콘을, .06 taper HEROShaper로 근관성형 후에는 DiaDent 거타퍼챠콘을 마스터콘으로 사용시 근관내 적합성이 우수하게 나타났다. 따라서 근관성형 후 사용한 Ni-Ti 파일과 같은 경사도를 가진 거타퍼챠콘이 근관에 알맞게 위치되는 것은 아니며 근관충전시 적절한 마스터콘의 선택이 필요함을 시사한다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.