• Title/Summary/Keyword: End-to-end suture

Search Result 73, Processing Time 0.024 seconds

Comparison of Tracheal Anastomosis by Interrupted and Continuous Technique of Absorbable polydioxanone (PDS) Suture Material in Rabbit (가토에서 흡수성 PDS 봉합사의 단속봉합술식과 연속봉합술식에 따른 기관문합의 비교)

  • 이석열;양성린;이길노
    • Korean Journal of Bronchoesophagology
    • /
    • v.7 no.1
    • /
    • pp.9-13
    • /
    • 2001
  • Background: Tracheal resection and end-to-end anastomosis are the preferred treatment for tracheal tumor or tracheal stenosis. Absorbable suture material has been commonly used in case of tracheal anastomosis. But anastomosis technique is controversial. This experimental study compared between interrupted suture and continuous suture using Polydioxanone (PDS) absorbable suture material after tracheal resection and end-to-end anastomosis in rabbits. Methods : Twenty-four rabbits were used, divided into two groups of 12 animals each. The trachea was resected and then anastomosed with continuous 6-0 polydioxanone (PDS) (group 1), and intermittent 6-0 polydioxanone (PDS) (group 2). The animals were followed up for 6 months. Stenosis of the trachea was assessed at the time of death. Results : In two groups, anteroposterior diameter, transverse diameter, cross sectional area, and perimeter were greater in group 2 than in group 1 but, not significantly different. In addition, histologic findings were not different in two groups. Conclusions : This study suggest that stenosis after tracheal resection and end-to-end anastomosis using absorbable polydioxanone (PDS) suture material be not significantly different in both groups.

  • PDF

Surgical Treatment of Ahilles Tendon Rupture Using Modified Lynn Method (변형 Lynn씨 방법에 의한 아킬레스건 파열의 수술적 치료)

  • Kang, Jae-Do;Kim, Kwang-Yul;Kim, Hyung-Chun;Kim, Jin-Hyung;Choi, Shin-Kwon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.7 no.2
    • /
    • pp.223-231
    • /
    • 2003
  • Purpose: Achilles tendon rupture has become more common in the recent years. As suture with foreign material has been blamed for impaired healing, better results should be expected from the use of autogenous material such as plantaris tendon. We have evaluated the surgical results of end-to-end anastomosis using the plantaris tendon as suture material. Materials and Methods: Between Jan 1997 and Jan 2002, the 60 patients were included this study during one year follow-up. We performed the operations with end-to-end suture technique using modified Lynn's method. The plantaris tendon has been used as a autogenous suture material and can be utilized in the end-to-end anastomosis of ruptured Achilles tendon with modifed Bunnel suture technique. We used a clinical scoring system reported by Leppilahti to evaluate the results. Results: The overall results were excellent in thirty eight(63.3%), good in sixteen(26.6%), fair in five(8.3%) cases, and poor in only one (1.6%) case. Fifty four cases(90%) had the score more than good. We had no deep infection, rerupture, deep vein thrombosis, and skin necrosis as major complication. In just 2 cases, although there were superficial skin infection, the wounds did not proceed necrosis due to using antibiotics. Conclusion: End-to-end anastomosis using the plantaris tendon as suture material was good treatment option that had low infection rate and no foreign body reaction because of using autogenous material, and therefore we can get rapid healing of ruptured tendon due to early ragne of motion and accerlerated rehabilitation.

  • PDF

Continuous Sutures for Microarterial Anastomosis (미세혈관 수술시 혈관개존율 향상을 위한 연구)

  • Jung, Young-Sik;Jeong, Jae-Ho;Choi, See-Ho;Seul, Jung-Hyun
    • Journal of Yeungnam Medical Science
    • /
    • v.3 no.1
    • /
    • pp.237-241
    • /
    • 1986
  • In clinical microsurgery, limitation of space often prohibits rotation of a double clamp in an end-to-end anastomosis, or shortage of length of the secondary vessel in an end-to-side anastomosis does not allow visualization of the back wall. In these situation, back wall repair is extremely difficult. To overcome this problem, we use continuous suture technique without rotation of double clamp for end-to-end and end-to-side anastomosis of the 40 rat femoral arteries. After continuous sutures for microarterial anastomosis, the following results were obtained: Continuous sutures are useful in anastomosis where there is unavoidable limited access to the posterior wall and for some of the larger vessels now being anastomosed in free flap and other reconstructive surgery.

  • PDF

Microvascular Anastomosis Using 'Continuous Suture with Interrupted Knot' Technique (연속 봉합 단속 결찰법을 이용한 미세 혈관 문합법)

  • Choi, Moon-Su;Park, Sang-Hoon
    • Archives of Reconstructive Microsurgery
    • /
    • v.8 no.1
    • /
    • pp.22-27
    • /
    • 1999
  • While the conventional end-to-end anastomotic technique is accepted as 'the golden standard' for microvascular anastomosis, it is time-consuming and tedious. In an effort to offer faster and safer ways of performing microvascular anastomoses, numerous anastomotic techniques have been proposed, but further refinements in microvascular techniques are still necessary. A 'continuous suture with interrupted knot' technique was devised for faster and safer anastomosis. It has been successfully used in microanastomoses of both artery and vein for free tissue transfer. It is a combination of the interrupted suturing technique and the continuous suturing technique. First, a continuous suture is made with the size of loop decreasing in order, and then the sutures are tied individually from the first loop to the last one as in the conventional interrupted suturing technique. It was applied clinically to fourteen patients over the past ten months and found to be a highly efficient technique that satisfied our needs. This 'continuous suture with interrupted knot' technique has several advantages over other techniques : The operative time is reduced comparing conventional interrupted suture technique. By delaying the tie and with the vessel walls kept separated, the risk of through-stitch can be reduced. Tying all the sutures at one time not only speed up the procedures, but also reduced the surgeon's fatigue. In addition, it has no problem of anastomotic stenosis which is a disadvantage of continuous suture technique. This technique proved to be faster and safer, and has patency equal to that of the conventional end-to-end anastomosis. It is of great help to the surgeon in reducing operative time, especially in clinical situations when many anastomoses are required, or lengthy grafting procedures are undertaken.

  • PDF

Comparison of Simple Interrupted Approximating Suture with Single Layer Continuous Connell Suture in End-to-end Intestinal Anastomosis of Dogs (개의 단단장문합술에서 단순결절접합봉합과 단층연속코넬봉합의 비교)

  • 이충헌;신영규;정순옥;이채용
    • Journal of Veterinary Clinics
    • /
    • v.18 no.2
    • /
    • pp.124-132
    • /
    • 2001
  • The purpose of this study is to know whether single layer continuous connell suture is an acceptable alternative to simple interrupted approximating suture for end-to-end intestinal anastomosis in dogs. Fourteen mixed-breed dogs weighing 2 to 5 kg were allotted to group treated with simple interrupted approximating suture (Group I) and group treated with single layer continuous Connell suture (Group II), each of 7 dogs. All dogs in each suture pattern were compared with time for total operation ad suture elapsed for intestines to anastomose, clinical signs, changing of pre-and postoperative luminal size, status of feces, adhesion at anastomotic site for 14 days after operation. Time for total operation and suture time for intestinal anastomosis were none significant between Group I and Group II, although those in Group II was about 3 minutes shorter than those in Group I, respectively. Group I spent average 47.08${\pm}$11.10 minutes on total operation, 20.97${\pm}$5.54 minutes on suture time for intestinal anastomosis and Group II spent average 44.74${\pm}$7.77 minutes, 17.73${\pm}$3.05 minutes, respectively. All dogs were no special differences in vitality, vomiting, appetite between Group I and Group II for 14 days after operation. All dogs, except one dog in Group I, had showed normal vitality and appetite since 6~8 days after operation. Initial return of fecal passage showed in all dogs before 6 days after operation and thereafter most dogs showed normal feces. According to results, it was thought that all dogs with normal vitality and appetite before 8 days had showed good prognosis. There were no changes of intestinal luminal size in 2 dogs performed Group In and one dog performed Group II between at operation and 14 days after operation. Narrowing rate of intestinal lumen in Group I was average 9.3% of the normal diameter, whereas in Group II, 9.5% of normal diameter. In complications after operation, only one dog in Group I showed intestinal intussusception but the others didn't. Length of adhesion was measured between intestinal anastomotic site and omental graft. Length of adhesion in dogs performed Group II was mostly shorter than that of Group I. Adhesion with proximate intestines occurred in five dogs, which consisted of 3 dogs performed Group I and 2 dogs performed Group II. Concurrently, they had a great length of adhesion between anastomotic site and omental graft. There were no great differences between Group I and Group II about speed of operation, clinical signs, complications such as leakage and stricture. And all dogs performed intestinal anastomosis showed good clinical condition and prognosis. In conclusion, Single layer continuous Connell suture can safely perform an intestinal anastomosis and be an alternative of simple interrupted approximating suture in aspect of speed clinically.

  • PDF

STUDY OF PATENCY RATE IN VARIABLE MICROVASCULAR ANASTOMOSIS (다양한 방법으로 적용한 미세혈관문합술간의 개존율연구)

  • Kim, Uk-Kyu;Kim, Yong-Deok;Byun, June-Ho;Shin, Sang-Hun;Chung, In-Kyo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.5
    • /
    • pp.349-357
    • /
    • 2003
  • Several microvascular anastomotic techniques have been described with methodical effectiveness, patency rates, healing state of microscopic findings. This experimental study presents the comparison of three types of arterial microvascular anastomotic techniques: end-to-end(ETE) anastomosis, end-in-end(EIE) anastomosis, and continuous technique. Sixty male Sprague-Dawley rats, 60 femoral arteries were used for this study. Twenty rats per each technique were used and sacrificed at post-operation 1 day, 3 days, a week, 2 weeks for scanning electromicroscopic findings. The patency was monitored by miniDoppler throughout total experimental periods. The anastomotic time on each method was measured to compare the technical effectiveness. The final results were as follows: 1. The anastomotic time for the end-in-end technique was significantly shorter than another techniques. The average time for each technique was measured as 15 minutes on EIE technique, 20 minutes on continuous technique and 25 minutes on ETE technique. 2. The patency rate for the end-in-end technique at 2 weeks also was superior to another techniques. The patency rate for each technique was demonstrated as 90 % on EIE technique, 85 % on ETE technique and 80 % on continuous technique. 3. The scanning electromicroscopic findings on healing condition of vessel endothelium during the observation period showed that the end results of EIE technique, ETE technique and continuous technique in sequence were good. The end-in-end technique proved to be the superior with regard to anastomotic time and patency rate when compared to end-to-end technuqe, so EIE techniqe might be well available for the case of large discrepancy of vessel size. The patency rate, microscopic healing findings in continuous technique were seen as the lowest level among the three anastomotic techniques, therefore the application of continuous technique was recommended only on the inevitable case.

Flow Dynamics Near End-To-End Anastomoses - Part I. In Vitro Compliance Measurement -

  • Kim, Y.H
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.165-174
    • /
    • 1992
  • Compliance mismatch across an end-to-end anastomosis was measured In the In vitro experimental setup. A 35mm camera was used and Image process was done in Gould/ DeAnza Image processor. The results showed that compliances of Penrose tubing and synthetic PTFE grafts were In good agreement with the previously reported In vivo data. PTFE grafts exhibited a nonlinear behavior with compliance decreasing with Increasing transmural pressure, whereas the compliance of the Penrose tubing remained relatively constant within the range of the pressures in which data were obtained. The lumen cross sections at the anastomosis were affected by the suture and the mismatch In compliance between the Penrose tubing and vascular grafts. The varla~lons In the lumen dtameter at the anastomosis was more pronounced with increasing transmural pressures. From the present study, it was clearly demonstrated that the compliance of prosthetic grafts Is much lower than that of the arteries. In addition to the hemodynamlc consequences, compliance mismatch across the anastomosis has been known to lead to Increased anastomotlc and suture stresses with resultant suture line dehlscence and false aneurysm formation. Thus, there are good hemodynamic reasons to suppose that Introduction of a less compliant arterial graft Into the arterial circulation wlll be damaging and that grafts should be made to match the elastic behavior of their host arteries as closely possible.

  • PDF

Eleven Cases on Peripheral Arterial Injuries (말초동맥손상 11례 보고)

  • 이승진;이남수;김형묵
    • Journal of Chest Surgery
    • /
    • v.7 no.1
    • /
    • pp.109-116
    • /
    • 1974
  • Eleven cases of peripheral arterial injuries treated at Korea University Woo Sok Hospital during these 3 years and 3 months from Feb. 1971Eleven cases of peripheral arterial injuries treated at Korea University Woo Sok Hospital during these 3 years and 3 months from Feb. 1971 to May 1974 were reviewed. Common causes of injuries were stab wound, automobile accidents and iatrogenic injuries during operation. Of the 11 arterial injuries 3 were femoral artery which` was the commonest in frequency and the next was 2 cases of brachial artery. The most frequent type of injury was transection. Laceration, contusion and spasm was also recognized. The need to operate immediately following an injury was emphasized. Operative procedures were end to end anastomosis and saphenous vein graft in 5 and 2 cases, respectively. Other cases were undergone multiple suture ligature due to staphyllococcal infection, insertion of polyethylene catheter, and lateral suture after thromboendarterectomy. Fractures and extensive soft tissue damage associated with arterial injuries with widespread destruction of the collateral circulation aggravated the situation and complicated the amputation of lower extremity in 4 cases. The factors influencing the amputation were time lag, presence of associated injuries and complications.[KTCS 1974;1:109-116] Common causes of injuries were stab wound, automobile accidents and iatrogenic injuries during operation. Of the 11 arterial injuries 3 were femoral artery which` was the commonest in frequency and the next was 2 cases of brachial artery. The most frequent type of injury was transection. Laceration, contusion and spasm was also recognized. The need to operate immediately following an injury was emphasized. Operative procedures were end to end anastomosis and saphenous vein graft in 5 and 2 cases, respectively. Other cases were undergone multiple suture ligature due to staphyllococcal infection, insertion of polyethylene catheter, and lateral suture after thromboendarterectomy. Fractures and extensive soft tissue damage associated with arterial injuries with widespread destruction of the collateral circulation aggravated the situation and complicated the amputation of lower extremity in 4 cases. The factors influencing the amputation were time lag, presence of associated injuries and complications.

  • PDF

Heterotopic Heart Transplantation in the Rat Model (쥐모델에서의 이소성의 심장이식)

  • Chung, Won-Sang;Jeon, Yang-Bin;Chun, Soon-Ho;Kim, Hyuk;Lee, Chul-Burm;Kim, Young-Hak;Jee, Heng-Ok;Seo, Jung-Kuk;Kong, Gu
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.531-535
    • /
    • 1998
  • In 1964, Abbott and Colleagues published the world's first heterotopic heart transplantation technique in the rat. Their method established circulation by end-to-end anastomoses of the graft's aorta and pulmonary artery to the recipient's abdominal aorta and Inferior Vena Cava(IVC), respectively. In 1966, Tomita et al altered Abbott's technique by employing end-to-side rather than end-to-end anastomoses, thus eliminating the hind leg paralysis that sometimes resulted from Abbott's technique. In order to prevent postsuture hemorrhage (since 7-0 silk suture was the finest available at that time), Tomita's aortic anastomosis was done with double up-and-down continuous suture technique. A single layer continuous anstomosis effected the pulmonary artery-IVC anastomosis. The availability of Nylon monofilament suture made it possible for Ono and Lindsey to use a single layer suture technique for the aortic end-to-side anastomosis in their modified rat heart transplantation. We observed survival time between control group and Immunosuppression(Cyclosporine administration, 10mg/Kg${\times}$4 times postoperatively) group after heterotopic heart transplantation in the rat model. The cyclosporine adminstration group survived longer than the control group, thus we concluded that cyclosporine was based on Immunosuppressive drugs.

  • PDF

A Single Left Lung Transplantation in Dog -One Case Report- (황견에서 좌측 폐이식수술 -1례 보고-)

  • 이두연
    • Journal of Chest Surgery
    • /
    • v.27 no.3
    • /
    • pp.238-240
    • /
    • 1994
  • We performed post-operative hemodynamic evaluation and lung perfusion scan after left lung transplantation in dog. The heart & lungs were extracted from donor dog while the both lungs were flushed with 4oC Euro-Collin`s solution after heparinization & infusion of prostaglandin E1.In the recipient dog, anastomosis of the left atrial cuff was performed by continuous 4-0 Prolene everted suture, and bronchial anastomosis by telescope method with 4-0 Prolene continuous suture. The end-to-end anastomosis of left main pulmonary arteries was performed with continuous 6-0 Prolene suture. After closure of left thoracotomy incision, the lung perfusion scan was performed post operative 2 days for evaluation of the function of the transplanted lung which showed good perfusion. The dog was sacrificed in the post-operative 5 days for autopsy.

  • PDF