• 제목/요약/키워드: End-to-end reliability

검색결과 631건 처리시간 0.027초

소프트웨어 개발 방법론 지원 시스템에 관한 연구 -정보시스템 개발을 위한 메타시스템의 설계를 주로- (A Study on System for Supporting Software Development Environment -On the Design of Meta System Supporting the Development of Information System-)

  • 이숙희
    • 한국통신학회논문지
    • /
    • 제15권10호
    • /
    • pp.811-818
    • /
    • 1990
  • 이 논문의 목적은 데이타베이스로의 정보 시장에 관한 작업을 담당하는 FLA(Flont-end Language Analyzer)와 여기에서 추출된 데이타베이스의 일관성과 완전성을 쉽게 검사할 수 있고 사용자의 요구에 따라 다양한 형태의 문서를 생성해 주는 BIS(Back-end Information system)를 구축함에 있다. 앞으로 본 시스템음 소프트웨어 시스템 개발에 실제로 사용됨으로써 소프트웨어의 생산성과 신뢰성 향상에 기여할 수 있으리라 예상된다.

  • PDF

국내 실정에 적합한 신뢰성 교육 모형에 관한 기초연구 (Development of an Efficient Reliability Education Program for Domestic Industries)

  • 권영섭;권영일;남경현;박동호;임재학;정해성
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제4권1호
    • /
    • pp.27-37
    • /
    • 2004
  • In this paper, we propose a framework of reliability education program for industry people taking charge of reliability improvement or reliability evaluation. To this end, we investigate the situation of how reliability theories or reliability technologies are applied to industry and how industry people have reliability educations. And we also identify reliability theories or technologies which industry people need to ensure. Based on the result of such studies, we design a reliability education program which is appropriate for industry people.

  • PDF

국내 실정에 적합한 신뢰성 교육 모형 개발에 관한 연구 (Development of an Efficient Reliability Education Program for Domestic Industries)

  • 권영섭;권영일;남경현;박동호;임재학;정해성
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2004년도 정기학술대회
    • /
    • pp.269-280
    • /
    • 2004
  • In this paper, we propose a framework of reliability education program for industry people taking charge of reliability improvement or reliability evaluation. To this end, we investigate the situation of how reliability theories or reliability technologies are applied to industry and how industry people have reliability educations. And we also identify reliability theory or technology which industry people need to ensure. Based on the result of such studies, we design a reliability education program which is appropriate for industry people.

  • PDF

미디어선택이 최종사용자의 만족도에 미치는 영향: SERVQUAL 연구 틀을 이용한 실증적 연구 (The Impact of Media Selection on End - user Satisfaction : An Empirical Study Based on SERVQUAL Framework)

  • 이상근;유상진
    • 경영과학
    • /
    • 제19권2호
    • /
    • pp.179-189
    • /
    • 2002
  • In this paper, we investigate the relationship between the use of different media and customer satisfaction in help desk service. Different dimensions of customer satisfaction were derived based on SERVQUAL : reliability, empathy, assurance, tangibles, and responsiveness. The results support our hypotheses that use of conventional media (face-to-face and telephone) is related to help desk satisfaction through reliability and empathy and electronic media (e-mali and internet) users show higher satisfaction in tangibles and assurance. Also, hybrid media users (multi-media users by task) show a higher level of satisfaction in reliability and responsibility. The results suggest that automating help desks should be considered as a way to provide more options to end-users.

정보센터의 사용자 지원활동이 사용자 만족도에 미치는 영향에 관한 연구 (A Study of the Effect on End-User Satisfaction for the End-User Supporting Activities in Information Center)

  • 윤중현
    • 정보관리학회지
    • /
    • 제24권3호
    • /
    • pp.5-19
    • /
    • 2007
  • 조직은 최종사용자 업무를 지원하기위한 새로운 정보시스템을 투자하고 있으며 이러한 정보시스템을 통한 이점은 정보센터의 효과적인 지원과 지원에 대한 사용자의 만족도에 의해 크게 좌우되어가고 있다. 정보센터는 정보 집약적이며 최신의 기술을 활용하여 조직의 역량을 전달하기 위해 사용자를 지원하므로 정보센터는 최종사용자 지원활동과 관련하여 매우 중요한 의미를 갖는다. 본 연구는 정보센터의 사용자 만족도와 관련된 정보제공, 신뢰제공, 그리고 시스템 제공역량과 같은 최종사용자 지원요인들을 살펴봄으로서 사용자만족도 향상을 위해 고려되어야 할 사항에 대해 논의하였다. 정보제공, 서비스 스텝의 신뢰성제공, 그리고 시스템제공 역량 등 18개의 잠재요인으로 252명의 사용자에 대한 설문내용을 기초로 3개의 가설을 검증하였다. 또한, 동일한 잠재요인에 대해 지원요인의 지각된 중요도와 수행정도의 차이를 통해 서비스 품질 격차를 조사하였다. 연구결과 정보제공 활동, 서비스 신뢰성제공 활동, 그리고 시스템 제공역량은 정보센터의 사용자 만족도에 유의한 영향을 미치는 것으로 파악되었으며, 사용자 만족도는 정보센터의 지원요인에 대한 지각된 중요도와 수 행정도에 대한 서비스 품질 격차의 정도에 의해서도 영향을 받는 것으로 밝혀졌다.

공압식 심실 보조기의 동물실험 (Animal Experiment of the Pneumatic Ventrivular Assist Device)

  • 박성식;김삼현;서필원;최창휴;이상훈;이혁수;황승옥;안혁
    • Journal of Chest Surgery
    • /
    • 제32권12호
    • /
    • pp.1065-1077
    • /
    • 1999
  • Background : Ventricular assist devices(VADs) are being used for patients in postcvardiotomy cardiogenic shock status bridge to cardiac transplant settings and in post-myocardial infarction cardiogenic shock. The VAD which was developed at the Deparment of medical engineering in Dankook University College of Medicine was a pneumatically driven device and can maintain pulsatile flow. The goal of this study is to develop animal experimental models using the VAD and to clarify the reliability and hemodynamic property adequacy of end organ perfusion durability and severity of thrombotic-hemolytic tendency of the device. Material and Method : The pneumatic VAD was applied to 8 adult female lambs, We examined some hemodynamic parameters such as arterial blood pressure pulmonary capillary wedge pressure(pcwp) pulmonary artery pressure(PAP) left atrial pressure hour urine output cardiac index VAD flow EKG to determine the reliability of the VAD and hemodynamic compatibility of the experimental animals within 24 hours of experiment. We also observed the end organ perfusion durability of the VAD and thrombotic-hemolytic property of the VAD after 24 hours of VAD insertion. Result: We could monitor all hemodynamic parameters including pcwp PAP cardiac index EKG, adn hour urine as true clinical settings. We observed that the reliability of the VAD was excellent and the hemodynamic property of the experimental animal and end organ perfusion were adequate within 24 hours of experiment. In four lambs surviving 24 hours after insertion the reliability of the VAD and end organ perfusion were excellent and no thrombotic-hemolytic tendency was noted. However after 15 days of experiment the diaphragm of the VAD was torn and it was recommende that the durability of the VAD should be extended. Conclusion : e conclude that the pneumatic VAD developed at Dankook University Biomedical Engineering has good hemodynamic property and low thromboembolic tendency and presents adequate end organ perfusion but we noted that the durability of the device should be expanded further. It will be possible to do more reliable experiment in the future according to the animal experimental method developed in this study especially with the heart failure models.

  • PDF

Negative-bias Temperature Instability 및 Hot-carrier Injection을 통한 중수소 주입된 게이트 산화막의 신뢰성 분석 (Reliability Analysis for Deuterium Incorporated Gate Oxide Film through Negative-bias Temperature Instability and Hot-carrier Injection)

  • 이재성
    • 한국전기전자재료학회논문지
    • /
    • 제21권8호
    • /
    • pp.687-694
    • /
    • 2008
  • This paper is focused on the improvement of MOS device reliability related to deuterium process. The injection of deuterium into the gate oxide film was achieved through two kind of method, high-pressure annealing and low-energy implantation at the back-end of line, for the purpose of the passivation of dangling bonds at $SiO_2/Si$ interface. Experimental results are presented for the degradation of 3-nm-thick gate oxide ($SiO_2$) under both negative-bias temperature instability (NBTI) and hot-carrier injection (HCI) stresses using P and NMOSFETs. Annealing process was rather difficult to control the concentration of deuterium. Because when the concentration of deuterium is redundant in gate oxide excess traps are generated and degrades the performance, we found annealing process did not show the improved characteristics in device reliability, compared to conventional process. However, deuterium ion implantation at the back-end process was effective method for the fabrication of the deuterated gate oxide. Device parameter variations under the electrical stresses depend on the deuterium concentration and are improved by low-energy deuterium implantation, compared to conventional process. Our result suggests the novel method to incorporate deuterium in the MOS structure for the reliability.

Reliability and Safety of Cross-Leg Free Latissmus Dorsi Muscle Flap in Reconstruction of Mutilating Leg Injuries Using End-to-Side Anastomosis

  • Ahmed Gaber Abdelmegeed;Mahmoud A. Hifny;Tarek A. Abulezz;Samia Saied;Mohamed A. Ellabban;Mohamed Abdel-Al Abo-Saeda;Karam A. Allam;Mostafa Mamdoh Haredy;Ahmed S. Mazeed
    • Archives of Plastic Surgery
    • /
    • 제50권5호
    • /
    • pp.507-513
    • /
    • 2023
  • Background Free tissue transfer is considered the gold standard option for the reconstruction of distal leg defects. Free tissue transfer using recipient vessels in the contralateral leg (cross-leg bridge) is a potential option to supply the flap if there are no suitable recipient vessels in the injured leg. Most studies have described this technique using end-to-end anastomosis which sacrifices the main vessel in the uninjured leg. This study evaluated the use of a cross-leg free latissimus dorsi muscle flap for the reconstruction of defects in single-vessel legs, using end-to-side anastomosis to recipient vessels in the contralateral leg without sacrificing any vessel in the uninjured leg. Methods This is a retrospective study that included 22 consecutive patients with soft tissue defects over the lower leg. All the reconstructed legs had a single artery as documented by CT angiography. All patients underwent cross-leg free latissimus dorsi muscle flap using end-to-side anastomosis to the posterior tibial vessels of the contralateral leg. Results The age at surgery ranged from 12 to 31 years and the mean defect size was 86 cm2. Complete flap survival occurred in 20 cases (91%). One patient had total flap ischemia. Another patient had distal flap ischemia. Conclusion Cross-leg free latissimus dorsi muscle flap is a reliable and safe technique for the reconstruction and salvage of mutilating leg injuries, especially in cases of leg injuries with a single artery. As far as preservation of the donor limb circulation is concerned, end-to-side anastomosis is a reasonable option as it maintains the continuity of the donor leg vessels.

무선 센서 네트워크의 전송 신뢰성을 제공하는 링크계층 프로토콜 (SLC : Reliable Link-layer protocol for wireless Sensor Networks)

  • 김남곤;석승준
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2009년도 추계학술대회
    • /
    • pp.578-580
    • /
    • 2009
  • 무선 센서 네트워크는 다양한 분야에 응용하여 사용하고 있다. 배터리를 사용하는 센서노드는 전원이 제한적이기 때문에 다양한 기능과 전송의 신뢰성보다 저전력을 사용하는 동작에 더 최적화 되어있다. 하지만 더욱 다양한 목적으로 정확한 데이터를 사용하기 위해서는 전송의 신뢰성이 보장되어야 한다. 멀티홉 환경으로 구성되어 있는 센서 네트워크에서 종단간 전송 신뢰성을 보장하기 위해서는 링크(홉)간의 전송 신뢰성이 바탕이 되어야 하지만, IEEE 802.15.4 표준은 링크계층의 전송 신뢰성을 고려하지 않고 있다. 본 논문에서는 에너지를 효율적으로 사용하면서 링크(홉)간 전송 신뢰성을 제공하기 위한 링크계층 프로토콜을 제안한다.

  • PDF

봉단 용접부 와전류탐상의 기초적인 연구 (A Basic Study on Eddy Current Testing of End-Cap Welds)

  • 서동만;심기섭;권우주;김정하;박춘호
    • 비파괴검사학회지
    • /
    • 제18권2호
    • /
    • pp.85-91
    • /
    • 1998
  • 핵연료 제작과정에서 봉단마개 용접부는 완벽한 품질이 요구되고 있다. 본 연구에서는 와전류탐상방법을 이용하여 봉단마개 용접부의 검사를 위한 기초적인 방법을 연구하였다. 봉단마개 용접부 와전류검사를 위한 주사속도와 와전류신호의 최대주파수를 찾았고 잡음신호제거를 위해 대역통과여파기(0-250Hz)론 사용하였다. 이러한 와전류탐상방법은 직경 0.35mm의 작은 핀홀결함에서도 좋은 감도를 얻을 수 있었다.

  • PDF