• Title/Summary/Keyword: End-to-end 시험

Search Result 850, Processing Time 0.027 seconds

Bearing Reinforcing Effect of Concrete Block with a Round End according to the Application of Aluminum Stiffener (알루미늄 보강재 적용에 따른 원형 단부 콘크리트 블록의 지압 보강 효과)

  • Seok Hyeon Jeon;Tae-Yun Kwon;Jin-Hee Ahn
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.3
    • /
    • pp.38-46
    • /
    • 2023
  • In this study, a bearing test was performed and analytically evaluated to evaluate the bearing performance according to the application of the aluminum stiffener in round-end concrete. In the bearing strength test, the change in bearing performance due to the aluminum stiffener using the aluminum form for manufacturing concrete with round-end, and the steel anchor bolts for member movement and assembly was confirmed. The FE analysis model was identically configured to the experimental conditions, and the result was compared with the experiment. Also, the crack patterns and stress behavior were confirmed. In addition, the effect of strength change of the aluminum stiffener on the round-end concrete was also evaluated analytically. The bearing strength of the round-end concrete increased by about 20% due to the aluminum stiffener, and it was confirmed that the steel anchor bolt did not affect the bearing strength. The maximum load and crack patterns shown as a result of FE analysis were similar to those of the experiment. As a result of FE analysis according to the strength change of the aluminum stiffener, the maximum load change according to the increase and decrease of the strength of the aluminum stiffener by 10% and 20% was evaluated to have no significant effect at a maximum of about 4% compared to before the strength change.

A Study for Experiment to Measure Mechanical Properties of Pressurizer Nozzle and Safety-Ends in Nuclear Power Plant (원전 가압기 노즐 및 안전단 재료에 대한 기계적 물성시험 연구)

  • Lee, Kyoung-Soo;Lee, Sung-Ho;Kim, Jin-Weon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.147-153
    • /
    • 2013
  • Recently the primary water stress corrosion cracking(PWSCC) has occurred in the dissimilar metal weld region between pressurizer nozzle and safe-end in nuclear power plants(NPPs). As material of the pressurizer nozzle, SA508 Gr. 3 low alloy steel was used. F316L stainless steel and Alloy 82/182 were used as safe-end and weld metal, respectively. Although mechanical properties are needed for evaluation of the structural integrity against flaw in the material, material specification and standard don't supply those properties. Therefore, the present study conducted tensile and fracture toughness tests on SA508 Gr.3 and F316L stainless steel at ambient temperature and operating temperature of NPPs and reported the tested results.

Application of an Adaptive Robust Controller to Cutting Force Regulation (견실한 서보적응제어기를 응용한 절삭력 추종제어)

  • 김종원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.78-89
    • /
    • 1991
  • This Paper presents an application example of the Adaptive Robust Servocontrol (ARSC) scheme, which is an explicit (or indirect) pole-assignment adaptive algorithm with the property of "robustness". The ARSC scheme is applied to an end-milling process for cutting force regulation. It is shown that the federate of an end-milling process can be maximized by the adaptive regulation of the peak cutting force through the ARSC scheme. The results of simulation study and real cutting experiment are presented. It has been verified that asymptotic regulation can be achieved with robustness against the slowly time-varying perturbations to the process model parameters, which are caused by nonlinear cutting dynamics. dynamics.

In -Cylinder Flow Characteristics Varying Intake Valve Lift (밸브 리프트 변화에 따른 실린더 내 흡입 공기의 유동 특성)

  • 윤정의
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.9
    • /
    • pp.82-88
    • /
    • 1999
  • The object of this study is to find new evaluation index for in-cylinder flow chracteristics istead of current swirl, tumble coefficient using steady flow test rig on intake port system. To this end, port flow system. To this end, port flow rig test was conducted on DOHC head varying intake valve lift respectively. Finally combination angular coefficient and inclination angle were introduced as new evaluation index for in-cylinder angularflow characteristics instead of swirl and tumble coefficient.

  • PDF

A Study on the Neck Injury Criteria Using BioRID-II during Very Low Speed Rear-end Collision (초저속 후방 추돌시 BioRID-II를 이용한 목 상해 지수 측정에 관한 연구)

  • Hong, Seungjun;Ryu, Hankyu;Kim, Youngeun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.4
    • /
    • pp.54-61
    • /
    • 2013
  • Although typically classified as AIS 1, whiplash injuries continue to represent a substantial social problem with associated costs estimated at over $1 billion annually. The primary objective of this study was to determine the effects of seat positions(seatback angle, headrest height) on risk for whiplash injury in very low speed(${\Delta}V$=4~10km/h) rear-end impact. To accomplish this, rear impact seat carriage tests and simulations were conducted using the BioRID-II dummy seated in a mass production seat, which allowed for the adjustment of seatback angle and headrest height. Neck injury criteria(NIC, Nkm) were then compared for different ${\Delta}V$ and seat positions.

End Bearing Capacity of Pile Tip-enlarged PHC Piles in Weathered Rock (풍화암에 근입된 선단확장형 PHC 말뚝의 선단지지력)

  • Yoo, Chung-Sik;Heo, Kab-Soo;Song, Ki-Yong;Kim, Sun-Bin
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.1
    • /
    • pp.23-37
    • /
    • 2007
  • Recently a concept of pile-tip enlarged PHC pile (Ext-PHC pile), for use in the auger-drilled construction method, has been developed and is being implemented in practice. A series of field axial load tests on both PHC and Ext-PHC piles were conducted at an experimental site. In addition, a parametric study on a number of influencing factors was made using a validated finite element model. The field axial load tests indicated an enhanced load-settlement characteristics for the Ext-PHC piles compared with the PHC piles, giving approximately 50% increase in the end bearing capacity. Also found in the results of the parametric study was that the increase in the end bearing capacity of Ext-PHC piles slightly varies with the mechanical properties of supporting ground as well as pile length, in the range of 1.25 to 1.4 time that of PHC. Overall, the results of the field tests as well as the numerical study confirmed that the end bearing capacity of PHC pile can be improved by the concept of.Ext-PHC pile.

Shape Change Analysis of a Small Propane Container by Pressure Test (소형프로판용기 내압시험을 통한 용기의 형상변화 분석)

  • Lee, Jong-Sang;Jang, Kap-Man;Lee, Yoon Hyoung;Yim, Sang-Sik;Lee, Jin-Han
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.6
    • /
    • pp.40-44
    • /
    • 2014
  • In this study, it is analyzed that a change in the shape of small propane containers made of STS304 when increasing of internal pressure. When internal pressure of a small propane container increased, bottom of end plate is convexly changed. This test is applied to a water bath pressure test to analyze the characteristics of the container. Water bath is able to analyze relationship between internal pressure and volume. In result, shape change section is confirmed because bottom of end plate is convexly changed. In addition, this section tend to decrease internal pressure because a volume increment increase out of proportion to pressure. The results of this study are expected to contribute to improving the safety of the pressure vessel, as well as various small propane container.

Study on the Basic Properties of Platanus occidentalis L. for Its End-use Development (양버즘나무의 용도개발(用途開發)을 위(爲)한 기초재질시험(基礎材質試驗))

  • Lim, Kie-Pyo;So, Won-Tek
    • Journal of the Korean Wood Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.8-15
    • /
    • 1990
  • This study was carried out to investigate the wood qualities for the end-use development of sycamore (Platanus occidentalis L.) grown in Korea. The results obtained were as follows: 1. The average length of wood fibers was l.56mm and the average width of annual rings was 9.5mm. It had very fast growth rate. 2. The specific gravity in air-dry was 0.66. The shrinkage and water absorption were relatively large. The shear and impact strengthes were very strong, while the compressive, tensile, and bending strengthes were weak in comparison to it's specific gravity. 3. The contents of ash, holocellulose, lignin were relatively high 0.74%, 83.08%, 28.79%, but that of pentosan was low 18.53%. 4. The expected uses of sycamore wood are plywood. fancy veneer, small furniture, musical instrument, door and window frame, tool handels, boxes, etc.

  • PDF

Evaluate Bond strength of high Relative Rib Area Bars Using Beam-end test specimens (보 단부 부착시험체에 의한 높은마디 철근의 부착성능)

  • Seo Dong Min;Yang Seung Youl;Hong Gi Suop;Choi Oan Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.112-115
    • /
    • 2004
  • Bond between reinforcing bar and surrounding concrete is supposed to transfer load safely in the process of design of reinforced concrete structures. Bond failure of reinforcing bar generally take place by splitting of the concrete cover as bond force between concrete and reinforcing bars exceeds the confinement of the concrete cover and reinforcement. However, the confinement force has a limitation. Thus, the only variable is the bearing angle corresponding to the change of bond force. Higher rib height bars possessing higher shearing resistance can maintain higher bearing angle and higher splitting resistance when bars are highly confined, and consequently higher bond strength, than lower rib higher bars. In this study, from the evaluate bond strength of high Relative Rib Area Bars Using beam-end test specimens are compared with the current provisions for development of reinforcement, and the improved design method of bond strength is proposed.

  • PDF

The Collapse Characteristics of Vehicle Thin-walled Members Coated Damping Material (댐핑재가 도포된 차체 박육부재의 압궤특성)

  • 송상기;박상규;송찬일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.1
    • /
    • pp.76-81
    • /
    • 2003
  • The purpose of this study is to analyze the collapse characteristics of widely used spot welded section members coated damping material Y1000 and to develop an analysis method for acquiring exact collapse loads and energy absorption ratio. Hat-shaped thin-walled members have the biggest energy absorbing capacity in a front-end collision. The sections were tested on quasi-static and impact loads. Specimens with two type thickness, width ratio and spot weld pitch on the flange have been tested in impact velocities(6.73n0sec and 7.54n1sec) which imitate a real-life car collision. As a result, it was developed the system for acquiring impact energy absorbing characteristics of structure united thin-walled member and damping materials.