• Title/Summary/Keyword: End Plate

Search Result 643, Processing Time 0.026 seconds

Discomfort caused by the circumferential comfortable retainer (CCR) as a removable maxillary retainer (상악 가철식 보정장치인 circumferential comfortable retainer (CCR)에 대한 불편감 평가)

  • Choi, Jin-Hugh;Moon, Cheol-Hyun
    • The korean journal of orthodontics
    • /
    • v.40 no.5
    • /
    • pp.325-333
    • /
    • 2010
  • Objective: The aim of this study was to illustrate the circumferential comfortable retainer (CCR) as a removable maxillary retainer with good potential patient compliance and to evaluate the discomfort of the retainers including distorted speech, gagging sensation and appliance discomfort. Methods: Sixty-six orthodontic patients (male, 23; female, 43; mean age, $23.42{\pm}10.19$ years) who received orthodontic treatment with fixed orthodontic appliances were randomly assigned to two groups after debonding, a conventional wraparound retainer (CWR) group that fully covers the palate with an acrylic plate and a highly polished surface, and a circumferential comfortable retainer (CCR) group which has a horseshoe shaped base plate with three folds on the anterior region. A questionnaire that had a visual analog scale (VAS) which consists of a 100-mm horizontal line with 2 end-points labeled "no discomfort" on the left and "worst discomfort" on the right, with regard to distorted speech, gagging sensation and discomfort, was administered to patients after 4 weeks of retainer wear. The Mann-Whitney test was used to test the hypothesis that there was no difference between the two retainers. Results: Comparing distorted speech and discomfort, the CCR group significantly had lower values than the CWR group ($p$ < 0.05). Comparing gagging sensation, the CCR group had lower values than the CWR group but there were no statistically significant differences between groups ($p$ = 0.146). Conclusions: In conclusion, the results suggest that the circumferential comfortable retainer (CCR) might facilitate patient compliance and thereby improve the maintenance of the fixed orthodontic treatment outcome.

Development of a Belt Pick-up Type Two-row Sesame Reaper

  • Jun, Hyeon-Jong;Choi, Il-su;Kang, Tae-Gyoung;Kim, Young-Keun;Lee, Sang-Hee;Kim, Sung-Woo;Choi, Yong;Choi, Duck-Kyu;Lee, Choung-Keun
    • Journal of Biosystems Engineering
    • /
    • v.41 no.4
    • /
    • pp.281-287
    • /
    • 2016
  • Purpose: The purpose of this study is to develop a walking-type two-row sesame reaper, which can simultaneously perform the cutting and collecting of sesame plants and other crops like perilla and soybean. Methods: The factors involved in reaping sesame were determined experimentally in order to design a prototype of the sesame reaper. The prototype is made up of four parts for cutting, conveying, collecting, and running. The height of two disc-plate saw blades on the cutting part is adjusted by an adjusting wheel, and peripheral speed is adjusted in accordance with the running speed. The conveying belt of the conveying part can be tilted from $0^{\circ}$ to $90^{\circ}$. The collecting part extracts a predetermined amount of transferred sesame plants. The prototype was used to evaluate the performance at different working speeds, so that the work efficiency can be calculated. Results: The center of gravity of the sesame plants was 900 mm, measured from the end of the cut stem. The diameter of the disc-plate saw blade was determined to be 355 mm, peripheral speed was 20.4-32.7 m/s, and the picking height of the conveying belt for sesame was 130 mm. The performance of transfer and collection of the sesame, when the insertion angles were $60^{\circ}$ and $90^{\circ}$, proved to be excellent. However, when the angle was over $120^{\circ}$, the performance was only 75-80%. The performance was at 100% efficiency when the ratio between running speed and conveying belt speed of the prototype was 1:2, which seems to be the ideal ratio for the sesame reaper. Conclusions: A sesame reaper was developed, which can integrate the processes of cutting, conveying, and collecting, by investigating and considering various factors involved in the reaping process. The sesame reaper can reduce the costs for yielding and producing sesame due to its highly efficient performance.

Development of a Korean Type Totally Implantable TAH (한국형 완전이식 인공심장의 개발)

  • Min, B.G.;Choi, W.W.;Ahn, J.M.;Park, S.K.;Park, C.Y.;Chang, J.K.;Kim, J.W.;Kim, H.C.;Kim, W.K.;Roh, R.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.199-202
    • /
    • 1996
  • Artificial hearts are intended for use in patients with severe forms of heart disease for which no surgical repair is possible. The moving-actuator pump was developed to decrease the overall volume size of the electromechanical total artificial heart (TAH) by eliminating the occupied space of the fixed-actuator in the conventional pusher-plate type pump. In our pump, the actuator moves back and forth for alternative ejections of left and right ventricles. The problem of fitting the TAH to atrial remnants and arterial vessels could also be improved by circular or penduluous mot ion of the actuator instead of linear mot ion of the pusher-plate in the conventional pumps. We have evaluated two types of moving- actuator pump; one is a rolling cylinder type, and the other a pendulum type pump. In the rolling cylinder pump, frictional energy loss exists between the pump housing's guide bars and the actuator's end caps, while the bottom rack under the cylindrical actuator increases the height of the pump, the pump is therefor not implantable inside the small chest of human-sized animals with a body weight of less than 70kg. The new human type pump has a penduluous mot ion actuator to correct the above problems while maintaining the advantage of the moving- actuator's small total volume. The totally implantable TAH is composed of a blood pump, a control system and pheriperal equipments. The blood pump, which is constructed by a moving actuator, a right and left blood sac, and four artificial valves, is implanted in the thoracic. In 1988, the first implantation of the rolling cylinder TAH was performed into a female calf weighing 100kg, and the cal f recovered to the degree of voluntary standing and eat ing and survived to 100 hrs. We then survived two female sheep weighing about 63kg with the new human type TAH for three days.

  • PDF

Performance Evaluation of a New Buried Expansion Joint (새로운 매설형 신축이음장치의 성능 평가)

  • Hong, Seong-Hyeop;Park, Sang-Yeol;Jwa, Yong-Hyun
    • International Journal of Highway Engineering
    • /
    • v.12 no.3
    • /
    • pp.27-35
    • /
    • 2010
  • Asphalt Plug Joint(APJ) is an buried expansion joint that enabling the smooth connection of expansion gap and road pavement by filling the gap with bituminous mixture of 20% bitumen and 80% aggregate by weight, so it secures evenness and expansion or contraction using the material's properties. Although APJ is designed to have a 6-7 year lifecycle, there are some cases where it is damaged within the first six months. This early damage cause traffic congestion due to frequent repair works, and social cost exceeding the installation cost of the joint. So, in this research, we have developed a new system of Buried Folding Lattice Joint(BFLJ) which can overcome the disadvantages of APJ, and have analyzed and compared it's performance with the conventional APJ through experiment with specimens. As a result of the experiment, APJ had crack formation on both ends of the gap plate, spreading to the surface of the expansion joint. With this result, we can conclude that the reason for early damage is the tension failure due to the concentration of strain in the asphalt mixture along the end of gap plate and the debonding along the joint section. In contrast, the newly developed BFLJ induced even transformation in the joint by applying moving stud and high performance material, and resolved APJ's disadvantage of strain concentration. Therefore, it could be seen that the newly developed BFLJ could overcome the disadvantages of APJ and prevent early damage.

Spinal Tuberculosis in Children: Predictable Kyphotic Deformity after Cure of the Tuberculosis (소아 척추 결핵: 투약 후의 병의 정지와 치유점, 그리고 후만 변형)

  • Moon, Myung-Sang;Kim, Dong-Hyeon;Kim, Sang-Jae;Moon, Hanlim;Kim, Sung-Soo;Kim, Sung-Sim
    • Journal of the Korean Orthopaedic Association
    • /
    • v.52 no.1
    • /
    • pp.73-82
    • /
    • 2017
  • Purpose: To assess the chronological changes of disease-related kyphosis after chemotherapy alone. Materials and Methods: A total of 101 children aged 2 to 15 years with spinal tuberculosis, accompanied by various stages of disease processes were enrolled for analysis. By utilizing the images in them, the growth plate condition and chronological changes of kyphosis after chemotherapy were analyzed at two points in time; the first assessment was at post-chemotherapy one-year and second at the final discharge. Results: Complete disc destruction in the cervical, dorsal and lumbosacral spines was observed in 2 out of 40 children (5.0%), 8 out of 30 children (26.7%), and 6 out of 31 children (19.4%), respectively. In those cases, the residual kyphosis inevitably developed. In the remaining children, the discs were intact or partially damaged. Among the 101 children kyphotic deformity was maintained without change in 20 children (19.8%). Kyphosis decreased in 14 children (13.9%), while it increased in 67 children (66.3%) with non-recoverably damaged growth plate. Conclusion: Although it is tentatively possible to predict the deformity progress or non-progress and spontaneous correction at the time of the initial treatment, its predictive accuracy is low. Therefore, assessment of the chronological changes should be performed at the end of chemotherapy. In children with progressive curve change, assessment of deformity should be continued until maturity.

Study on the Manufacturing Techniques of Metallic Ornament of Treasure 930, the Staffs of Yi Gyeong-seok (보물 제930호 이경석 지팡이에 사용된 장석의 제작기법 고찰)

  • Lee, Jae-sung;Jeon, Ik-hwan
    • Journal of Conservation Science
    • /
    • v.31 no.3
    • /
    • pp.309-318
    • /
    • 2015
  • The staff given with chair to Yi Gyeong-seok, senior official over 70 years old by King Hyeonjong of Joseon Dynasty is representative handcraft of Joseon Dynasty. Results of analysis on the metallic decoration show that the metallic ornament of the end part which is connected to the spade was made by rolling of iron plate and brass plating. The plated part is limited to the ornament of the end part connected to the spade and the plating was not applied to the spade. Brass including 20% zinc was used for the connecting part of guard while brass gilded iron was used for the spade. This suggests that the tone of the connecting part of the guard and the spade was not different for reason of visual harmonization. Potential applied plating method can be amalgam, dippping in molten brass, and brushing but the analysis result suggests that dipping in molten brass method is the most likely accepted method. The brass guard of knife was joined by tin-lead solder. Rivet used to fix the blade was made by pure iron as an optimum material which satisfies flexibility and strength.

Effect of Drift Pin Arrangement for Strength Property of Glulam Connections (드리프트 핀의 배열 형태가 집성재 접합부의 회전 거동 및 강도 성능에 미치는 영향)

  • Lee, In-Chan;Park, Chun-Young;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.10-21
    • /
    • 2007
  • It is necessary to study about moment performance of glulam-dowel connections which had been applied rotation. To analyze and predict the moment performance, angled to grain load was replaced with parallel to grain load and perpendicular to grain load. The dowel bending strength and dowel bearing strength were tested. And tensile strength test for connections of two different end distances was performed. Specimens of rotation test were composed with different drift pin numbers and drift pin arrangement. Connection deformation was occurred by plastic behavior of drift pin after yield when tensile load applied at connection. And the absorbing drift pin deflection by end distance continued the connection deformation. When rotation applied at connection that 2 drift pins were arranged parallel to grain (b2h), it showed similar performance with tensile perpendicular to grain. And connection that 2 drift pins were arranged perpendicular to grain (b2v) showed similar performance with tensile parallel to grain. Connection capacity that 4 drift pins were arranged rectangular (b4) showed 1.7 times as strong as connection that 2 drift pins were arranged parallel to grain (b2h). These results agreed predicted values and it is available that rotation replaced with tensile load.

Study on the Cyclic Seismic Testing of U-shape Hybrid Composite Beam-to-Composite Column Connections (신형상 U형 하이브리드 합성보와 기둥 접합부의 내진성능에 관한 연구)

  • Kim, Sung Bae;Kim, Sang Seup;Ryu, Deog Su
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.1
    • /
    • pp.47-59
    • /
    • 2013
  • This study that is a successive secondary study right after the primary bending strength test of a new form of U-shape hybrid composite beam is a cyclic seismic test of U-shape hybrid composite beam and column conncetion. Three specimens are built for the variables which are kinds of columns, depth of beam, continuity or discontinuity of upper plate of beam, and a number of steel bars of end-beam. Kinds of columns are a reinforcement concrete column and a ACT column of CFT shape, and beam depth are 300, and 500 mm. Detail of connection is bolt connection with using a short bracket that is commonly use. As the result, deformability of 2~4% is ensured the floor displacement angle. If it is the negative moment, the maximum moment shows that its capacity is above the nominal moment.

Algorithm to determine injection position in olive flounder, Paralichthys olivaceus

  • Cha, Bong-Jin;Kwon, Mun-Gyeong;Kim, Hyun-Young;Park, Myoung-Ae
    • Journal of fish pathology
    • /
    • v.26 no.2
    • /
    • pp.59-64
    • /
    • 2013
  • This study aimed to develop an algorithm to determine the optimal injection position in olive flounder, Paralichthys olivaceus when a vaccine is injected into the fish by using a vision-based automatic equipment measruing the total length (TL), width and weight of the fish. Over a 5-month period, 500 olive flounders were examined to analyze the relation of the fish size and to the shape and location of its abdomen, using radiography, a ruler plate and scale. There were significant correlations between the TL and the shape and location of the abdomen. The abdomen was located 0.232TL - 2.7221 mm ($R^2$=0.8787) from the end of the mouth of the fish. The height and width of the abdomen in the fish were 0.1292TL + 1.8768 mm ($R^2$=0.7935) and 0.183TL-5.9791 mm ($R^2$=0.8641), respectively. The injection point in the abdominal region avoiding organs was determined by calculating the center of gravity of the abdomen volume. This can be expressed as g (0.2759TL - 2.0965, 0.1295TL - 4.2325) on the basis of TL line coordinates. The injection point by the expressed coordinates had errors for the x and y axes as 12.15 mm and 8.28 mm, respectively. These were enough to use the algorithm to injection for the equipment. This automated method to determine the position of any part in the fish can also be used for other purposes, for example, intramuscular injection or auto-tagging of fish.

The effect of whole body vibration training on postural sway in patients with spinal cord injury: a pilot study

  • Asakawa, Yasuyoshi;Lee, Myung-Mo;Song, Chang-Ho
    • Physical Therapy Rehabilitation Science
    • /
    • v.2 no.2
    • /
    • pp.70-74
    • /
    • 2013
  • Objective: The aim of this study was to determine the impact of the application of whole body vibration training (WBV) on the balance ability of patients with an American Spinal Injury Association (ASIA) type C or D spinal cord injury. Design: Randomized controlled trial. Methods: Twelve patients with spinal cord injury were enrolled in this study. The participants were randomized to an experimental group (n=6) or control group (n=6). The subjects in the experimental group received WBV exercise and the control group received the sham exercise without vibration. The vibrations were adjusted vertically to the patient at a 30 Hz frequency and 3 mm amplitude. The whole body vibration lasted for 16 minutes in total including 5-minutes warm-up and cool-down at the beginning and end of the program, respectively. The static sitting balance ability was assessed by measuring the postural sway while sitting on the force plate with the eyes opened or closed. Postural sway length was measured for 30 seconds with a self-selected comfortable position. Results: In the static balance test, the anterio-posterior, medio-lateral, and total postural sway length with the eyes open and closed was improved significantly before and after the intervention in the experimental group (p<0.05). The experimental group showed significantly more improvement than the control group (p<0.05). Conclusions: Our results demonstrated that WBV training has a positive effect on improving static sitting balance and enhanced control of postural sway in patients with an ASIA-C or D type spinal cord injury.