• 제목/요약/키워드: Enclosure

검색결과 644건 처리시간 0.023초

수평격판을 갖는 정사각형 밀폐공간내에서 자연대류 유동 및 열전달 (Natural Convective Flow and Heat Transfer in a Square Enclosure with a Horizontal Partition)

  • 정인기;김점수;송동주
    • 대한기계학회논문집
    • /
    • 제17권9호
    • /
    • pp.2304-2314
    • /
    • 1993
  • Natural convective flow and heat transfer in a two-dimensional square enclosure fitted with a horizontal partition are investigated numerically. The enclosure was composed of the lower hot and the upper cold horizontal walls and the adiabatic vertical walls, and a partition was situated perpendicularly at the one vertical insulated wall. The governing equations are solved by using the finite element method with Galerkin method. The computations were carried out with the variations of length, position and thermal conductivity of the partition, and Rayleigh number based on the temperature difference between two horizontal walls and the enclosure height with water(Pr=4.95). As the results, an oscillatory motion of natural convection is resulted in a sudden rise of overall heat transfer, but the increase of length of partition is significantly restrained the increase of Nusselt number. The maximum heat transfer was shown just before the transition of the direction of oscillating flow. An oscillatory motion of flow was perfectly shown the stability with the decrease of the length of partition and Rayleigh number. Also, the heat transfer was raised with the increase of the thermal conductivity in proportion to the increase of the length of partition. The stability and oscillation of flow are affected by the position of partition.

개구를 갖는 함체의 외부 다이폴 파원에 의한 침투전계와 공진 주파수 특성 (Penetrated Electric Fields and Resonant Frequencies inside Metallic Enclosure with Aperture Exited by an External Dipole Source)

  • 황보승;김기채
    • 한국전자파학회논문지
    • /
    • 제12권6호
    • /
    • pp.939-947
    • /
    • 2001
  • 본 논문에서는 외부 다이폴 파원에 의해 합체의 개구를 통하여 침투하는 침투 전계와 함체의 공진 주파수 특성을 검토하고 있다. 이론해석 방법으로서는 외부 다이폴 파원의 전류분포 및 함체에 있는 개구의 개구면 전계분포에 관한 연립 적분방정식을 Galerkin의 모멘트 법으로 해석하고 있다. 이론해석의 결과, 침투전계는 개구면 부근에서 가장 크며, 함체의 공진 주파수는 개구가 없는 경우의 공진 주파수와 거의 일치하므로 함체의 크기가 결정되면 공진 주파수의 추정이 가능하다는 것을 알 수 있었다. 이론해석의 타당성을 화인하기 위하여 함체의 내부 전계 및 공진 주파수의 실험치와도 비교하고 있다.

  • PDF

헬름홀츠 공명기 배열을 이용한 인클로저 내부의 저주파 소음 저감 (Low-frequency Noise Reduction in an Enclosure by using a Helmholtz Resonator Array)

  • 박순홍;서상현
    • 한국소음진동공학회논문집
    • /
    • 제22권8호
    • /
    • pp.756-762
    • /
    • 2012
  • A method of the low-frequency noise reduction in an enclosure by using an array of Helmholtz resonator is presented. An integral form of equation, which represents the acoustical coupling between the internal sound field and the resonator array, is formulated so that the boundary element method can be applied to solve the coupling problem. It is shown that the resonator array on the surface of the enclosure can be regarded as impedance patches on the boundary element. Experiments on a simple enclosure acoustically coupled with an array of resonators are conducted to verify the method. The predicted noise reduction by the boundary element method shows good agreement with the measured one. The effects of the resistance of resonators as well as the number of resonators on the noise reduction are demonstrated. As a practical example, the presented method is applied to the payload fairing of a space launcher with resonator arrays. It is demonstrated that the resistance of resonators affects significantly the required number of resonators to achieve a desired noise reduction.

급격한 조석 감소에 의한 새만금 갯벌 대형저서동물 변화 (Changes in Benthic Macrofauna of the Saemangeum Tidal Flat as Result of a Drastic Tidal Reduction)

  • 구본주;신상호;이석
    • Ocean and Polar Research
    • /
    • 제30권4호
    • /
    • pp.485-495
    • /
    • 2008
  • Tidal ranges of inner Saemangeum were largely reduced after the final dyke enclosure, resulting in the former tidal flats becoming either permanently exposed, still influenced by changing tide, or permanently submerged. The effect of reduced tidal range on survival and population stability of tidal flat macrofauna were investigated at three shifted habitats after the dyke completion. At the exposed area, several species survived for 80 days after the dyke enclosure. However, within 120 days, all macrofauna died off due to the elevated temperature during summer. At the intertidal area, some species were maintained until 170 days after the dyke enclosure with a large decrease of the faunal abundance. Species of the submerged area were seen to be more tolerant of the changed environments. The opportunistic species, such as Sinocorophium sinensis, Theora fragilis and Pseudopolydora Kempi, were massively introduced into the submerged area after the dyke enclosure, in which the benthic ecosystem was severely disturbed.

정사각형 밀폐공간내에서 수평격판에 의한 자연대류의 진동현상 (Oscillatory Motion of Natural Convection in a Square Enclosure with a Horizontal Partition)

  • 김점수;정인기;송동주
    • 설비공학논문집
    • /
    • 제5권4호
    • /
    • pp.285-294
    • /
    • 1993
  • An oscillatory motion of natural convection in a two-dimensional square enclosure fitted with a horizontal partition is investigated numerically. The enclosure was composed of the lower hot and the upper cold horizontal walls and the adiabatic vertical walls, and a partition was positioned perpendicularly at the mid-height of one vertical insulated wall. The governing equations are solved by using the finite element method with Galerkin method. The computations were carried out with the variations of the partition length and Rayleigh number based on the temperature difference between two horizontal walls and the enclosure height with water(Pr=4.95). As the results, an oscillatory motion of natural convection has perfectly shown the periodicity with the decrease of Rayleigh number, and the stability was reduced to a chaotic state with the increase of Rayleigh number. The period of oscillation gets shorten with the decrease of the partition length and the increase of Rayleigh number. The frequency of oscillation obtained by the variations of stream function is more similar to the experimental results than that of the average Nusselt number. The stability of oscillation grows worse with the increase of Rayleigh number. The transition Rayleigh number for the chaos is gradually decreased with the increase of the partition length.

  • PDF

수평격판으로 분리된 정사각형 밀폐공간내의 층류 자연대류 해석 (An investigation of laminar natural convection in a square partitioned enclosure)

  • 김점수;정인기
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.312-322
    • /
    • 1997
  • The natural convective flow in a two-dimensional square enclosure with horizontal partitions is investigated numerically. The enclosure was composed of the lower hot and the upper cold horizontal walls and the adiabatic vertical walls, and two identical partitions were positioned perpendicularly at the mid-height of the right and left walls, respectively. The governing equations are solved by using the finite element method with Galerkin method. Calculations are made for different partition lengths, partition conductivites, and Rayleigh numbers based on the temperature difference between two horizontal walls and the enclosure height with water(Pr=4.95). An oscillatory motion of the natural convective flow is affected significantly by the variation of the gap width and Rayleigh number. When the gap width is comparatively short, the heat transfer rate is raised with the increase of the thermal conductivity of partitions. However, for sufficiently large gap widths at higher Rayleigh numbers, the average Nusselt numbers of the conductive partitions are smaller than those of the adiabatic partitions.

  • PDF

등가소스법을 이용한 공간 내의 음장 모델링에서 경계면 조건 오차의 최소화에 관한 연구 (A Study on Minimising the Errors on the Boundary Conditions when Using an Equivalent Source Technique for a Modelling of Sound Field inside an Enclosure)

  • 백광현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.581-586
    • /
    • 2000
  • The equivalent source method is used to calculate the internal pressure field for an enclosure which can have arbitrary boundary conditions and may include internal objects which scatter the sound. Some of the equivalent positions are chosen to be the same as the first order images of the source inside the enclosure, some are positioned on a spherical surface some distance outside the enclosure. The normal velocity on the surfaces of the enclosure walls is evaluated at a larger number of positions than there are equivalent sources. The sum of the squared difference between this velocity and the expected is minimized by adjusting the strength of the equivalent sources. The convergence of this method is checked by evaluating the velocity error at a larger number of monitoring positions. Example results are presented for various numbers of sources and evaluation points. The results showed that in general the more equivalent sources increased the accuracy of the sound field predictions but the accuracy is not too much sensitive to the numbers of evaluation points.

  • PDF

차폐막이 있는 밀폐공간 내에서의 난류 자연대류 - 복사열전달에 관한 연구 (A Study on the Turbulent Natural Convection - Radiative Heat Transfer In a Partitioned Enclosure)

  • 박경우;이주형;박희용
    • 대한기계학회논문집
    • /
    • 제18권10호
    • /
    • pp.2738-2750
    • /
    • 1994
  • The Effects of radiative heat transfer on turbulent flow in a partitioned enclosure is studied numerically. The enclosure is partially divided by a thin, poorly conducting vertical divider projecting from the ceiling of the enclosure. The low Reynolds number $k-{\epsilon}$ model is adopted to calculate the turbulent flow field. The solutions to the radiative transfer equations are obtained by the discrete ordinates method(DOM). This method is based on control volume method and is compatible with the SIMPLER algorithm used to solve the momentum and energy equations. The effects of optical thickness and Planck number on the flow, temperature fields and heat transfer rates are investigated for a moderate Rayleigh number($=10^9$). The changes in buoyant flow fields and temperature distributions due to the variation of baffle length are also analyzed. From the predictions, radiant heat exchange between the baffle and the sidewalls strongly influences the temperature distribution in the baffle and its vicinity and total heat transfer increases as the optical thickness and the baffle length decrease. It is possible to neglect the radiative heat transfer effect when Planck number is over one.

발열체와 부분 열림 수직벽을 갖는 사각 공간 내 자연대류 특성 해석 (A Study on the Characteristics of Natural Convection in a Partially Opened Enclosure with a Heat Source)

  • 심동식;강보선;차동진;주원종
    • 대한기계학회논문집B
    • /
    • 제24권12호
    • /
    • pp.1588-1595
    • /
    • 2000
  • Natural convection heat transfer in an enclosure with an opening in the right veritcal wall and a heat source at the bottom surface is investigated using a holographic interferometric technique. The effects of the opening length, divider length attached to the top wall, and heater temperature on the temperature distribution are examined. The opening length as well as the divider length greatly affects the degree of inflow and outflow of air. In the case of small opening length, the opening doesnt affect much the upward warm air flow resulting in the symmetric temperature distribution .The upward flow in hindered by the divider resulting in the decrease of heat transfer from the heater region to the upper region. The longest divider shows the highest temperature in the lower region of enclosure. In the case of large opening length, the inward cold flow moves the upward flow to the left direction. Among the cases of different divider length, the case of H(sub)d=0.25H shows the highest temperature in the lower region of enclosure.

수평격판을 갖는 상부가 부분 개방된 밀폐공간내의 자연대류 (Natural Convection in a Partially Opened Enclosure with a Horizontal Divider)

  • 김점수;정인기;송동주
    • 설비공학논문집
    • /
    • 제7권3호
    • /
    • pp.528-537
    • /
    • 1995
  • Natural convective flow and heat transfer characteristics in a partially opened enclosure fitted with a horizontal divider are investigated numerically. The enclosure is composed of a lower hot and a upper cold horizontal walls and adiabatic vertical walls. A divider is attached perpendicularly to the vertical insulated wall. The governing equations are solved by using the finite element method with Galerkin method. The computations have been carried out by varying the length of divider, the opening size, and the Rayleigh number based on the temperature difference between two horizontal walls and the enclosure height for air(Pr=0.71). As result, when the opening size is fixed, the intensity of the secondary flow is weaken as the length of divider increases. The maximum heat transfer rate over the upper cold wall occurs at a position bounded on the opening. However, when the length of divider is increased considerably, its maximum occurs at the right wall. The stability and frequency of oscillation are affected by the Rayleigh number and length of divider. The Nusselt number is increased with the increase of the opening size and the increase of Rayleigh number.

  • PDF