• 제목/요약/키워드: Enclosed Sound of Field

검색결과 8건 처리시간 0.022초

LQR 제어기를 이용한 밀폐음장의 능동소음제어 (fictive Noise Control of Enclosed Sound Field Using LQR Controller)

  • 유우열;김우영;황원걸;이유엽
    • 한국소음진동공학회논문집
    • /
    • 제12권1호
    • /
    • pp.12-20
    • /
    • 2002
  • To control the noise of an enclosed sound field, we built a state space model using the acoustic modal parameter description. Using the state space model, we can investigate the controllability and observability, and find an appropriate position of control speaker and microphone to control sound field of the enclosed space. We implemented LQR(linear quadratic regulator) controller and reduced order observer to reduce the first acoustic mode. Experiments showed satisfactory results of 4∼10 dB reduction of magnitude of the first acoustic mode, and support the feasibility of the proposed scheme to lightly damped acoustic field.

Acoustic Power Control of a Lightly-Damped Enclosed Sound Field

  • Kim, Woo-Young;Kim, Dong-Kyu;Hwang, Won-Gul
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제2권2호
    • /
    • pp.19-27
    • /
    • 2001
  • This research attempts to find an active control strategy which reduces acoustic power and acoustic energy in lightly-damped enclosed sound field such as a vehicle compartment or an operating room of heavy industrial machinery. An active control strategy, which takes into consideration of the acoustic radiation power of the source as a cost function, is formulated and examined to find capability of reducing noise. An adaptive filtering algorithm for sound power control is suggested and implemented to control lightly-damped sound field. To verify the method, sound power based active noise control algorithm was implemented on a rectangular box with lightly-damped wall, and popular acoustic energy based control with modal coupling reduction was performed to compare the noise reduction performance. It was shown that a total sound power based strategy provides a practical mean for global noise reduction for lightly damped sound field.

  • PDF

간선도로 방음터널의 효과와 타당성 (Effectiveness and Validity of Noise Barrier Tunnels on Main Line Roads)

  • 오양기;김하근;김영준;정대업;권성안
    • KIEAE Journal
    • /
    • 제2권1호
    • /
    • pp.55-61
    • /
    • 2002
  • It seems inevitable for residential buildings to be high-rise and allocated near traffic roads due to the overcrowding in urban area. Acoustic environment in those residential buildings has been seriously deteriorated by the increase of traffic vehicles. Commonly used sound barriers have a limitation in controlling noise diffracted over the boundary of a sound barrier and hence are not effective to attenuate noise especially for the residential units in high level. The use of an enclosed noise barrier can be an alternative to supplement the defects of conventional noise barriers. The present work aims at providing useful data in designing enclosed noise barriers for residential areas adjacent to roads. Number of field measurements for various noise barriers and enclosed noise barriers were carried out and the results were discussed with relation to the proper design of enclosed noise barriers.

Airborne Sound Insulation Performance of Window and Indoor Noise Level in the Balcony Expanded Apartments

  • Park, Hyeon Ku
    • KIEAE Journal
    • /
    • 제15권2호
    • /
    • pp.61-67
    • /
    • 2015
  • Purpose: The balcony in the apartment is important space not only as a fire escape but also as a buffer for heat and sound insulation. However, with the legalization of balcony expansion for residential apartments in Korea in 2006, many households have eliminated the balcony space altogether to increase the inner space, often without sufficient consideration for the effects on the indoor environment. This study examined the sound insulation performance of exterior-facing windows in enclosed balconies and the changes in the indoor acoustic environment due to expansion to provide a basis for appropriate balcony expansion. The apartments for the field test were chosen where two balcony types can be compared, and the sound insulation performance for the eighteen balcony windows was measured. The windows installed were typical double window with thickness 16 mm or 22 mm. Measurements of the weighted standard sound pressure level difference showed a decrease of about 3 dB in sound insulation performance due to expansion. For common exterior noise levels of 70-85 dB(A), the indoor noise level can exceed 45 dB(A), the limit level regulated in Korea. However, it was found that the sound insulation performance of the window and the quality of the construction have more influence on indoor noise levels than balcony expansion itself.

대형 변압기의 밀폐장치용 소음기 개발 (Development of a Silencer for an Acoustic Enclosure of a Large Transformer)

  • 이준신;이욱륜;이대성
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.786-789
    • /
    • 2005
  • An acoustic total or partial enclosure is widely used to reduce the sound pressure level propagating from a noise source. However, the performance of the acoustic enclosure is decreased by its inherent limitations such as temperature rise or acoustic pressure build up inside the enclosed acoustic field. In general, a silencer is installed to overcome these limitations, for large amount of air can be exchanged through the silencers. In this reason, a parallel baffle type duct silencer with acoustic resonators is studied to reduce the transmitted noise from a transformer. In this silencer, the high frequency components of the transmitted noise over 360Hz are effectively absorbed by the parallel baffles and the other ones, 120 and 240 Hz, are reduced due to the presence of Helmholtz resonators. Large sound attenuation is achieved by applying the sound resonating barrier to the large transformers in a substation.

  • PDF

조화가진된 밀폐계 음장에서의 능동소음제어 (I) 컴퓨터 시물레이션 (The Active Noise Control in Harmonic Enclosed Sound Fields (I) Computer Simulation)

  • 오재응;이태연;김흥섭;신준
    • 대한기계학회논문집
    • /
    • 제17권5호
    • /
    • pp.1054-1065
    • /
    • 1993
  • 본 연구에서는 정상상태의 단일 주파수에서의 임의의 음압분포로 조화가진되 는 3차원 정방형 밀폐계 음장의 경우에 대한 능동제어를 시도함으로써 사무실과 같은 실내 공간에 대한 능동적 소음저감의 응용 가능성을 검토하고자 하였다. 또한 변환기 의 위치선정을 위하여 상태공간 모드 모델의 모드 근사화에 따른 계수행렬의 요소를 평가함으로써 가제어성과 가광측성을 만족하는 최적한 변환기 (부가음원, 마이크로폰) 의 위치를 선정하였다. 밀폐계 내부의 음압을 저감시키는 목적함수로는 전체 시간평 균 음향 포텐셜에너지를 사용하였으며 폐공간의 음압변동을 이론적으로 규명함으로써 부가적인 음원의 복소세기를 적절히 선정하여 이 음향 포텐셜 에너지의 양을 최소화 시킬 수 있음을 보였다.

저소음 변압기용 조립식 철판 방음실 개발 (Development of an Acoustic Enclosure for the Large Low-Noise Transformer)

  • 이준신;이욱륜;손석만;구교선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.87-88
    • /
    • 2007
  • An acoustic total or partial enclosure is widely used to reduce the sound pressure level propagating from a noise source. However, the performance of the acoustic enclosure is decreased by its inherent limitations such as temperature rise or acoustic pressure build-up inside the enclosed acoustic field. In this reason, an acoustic enclosure consisting of a silencer and absobent panels with acoustic resonators is studied to reduce the transmitted noise from a transformer. Large sound-attenuation is expected by applying the enclosure to the large transformers in a substation.

  • PDF

Multi-Domain Structural-Acoustic Coupling Analysis Using the Finite Element and Boundary Element Techniques

  • Ju, Hyeon-Don;Lee, Shi-Bok
    • Journal of Mechanical Science and Technology
    • /
    • 제15권5호
    • /
    • pp.555-561
    • /
    • 2001
  • A new approach to analyze the multi-domain acoustic system divided and enclosed by flexible structures is presented in this paper. The boundary element formulation of the Helmholtz integral equation is used for the internal fields and the finite element formulation for the structures surrounding the fields. We developed a numerical analysis program for the structural-acoustic coupling problems of the multi-domain system, in which boundary conditions such as the continuity of normal particle velocity and sound pressure in the structural interfaces between Field 1 and Field 2 are not needed. The validity of the numerical analysis program is verified by comparing the numerical results with the experimental ones. Example problems are included to investigate the characteristics of the coupled multi-domain system.