• 제목/요약/키워드: Enclosed Indoor Spaces

검색결과 6건 처리시간 0.023초

복합문화시설내 공간 구조에 따른 일조와 일사가 실내 온열환경에 미치는 영향 (Effects of Daylight and Solar Radiation on Indoor Thermal Environment According to Space Structures in Multi-Complex Cultural Center)

  • 최병보;전현식;윤석일;김석환;이상진;김수민
    • 설비공학논문집
    • /
    • 제24권11호
    • /
    • pp.751-758
    • /
    • 2012
  • Recently, people are paying attention to new forms of construction. For example, deviated from an enclosed type space, people have been interested in an atrium type and an arcade type spaces. In this study, we had hypothesis 'Indoor thermal environment will be influenced by the inflow rate of natural lights with temperature and humidity.' We selected a multi-complex cultural center and conducted this study. This place is consisted of atrium, arcade, and enclosed types. The three spaces were classified according to the type of spaces that have own features along with their forms. The atrium type space has ceiling and the side windows, and the arcade type space has ceiling windows. On the other hand, there are no windows or open parts in the enclosed type space. Three measurement points at each space were selected because of their huge space. Intensity of illumination, temperature and humidity were confirmed by the average value of three measurement points. In addition, surveys were conducted regarding indoor comfort elements in each space.

밀폐공간 내 감염병 위험도 모니터링을 위한 열화상 온도 스크리닝 시스템 설계 및 구현에 대한 연구 (A Study on the Design and Implementation of a Thermal Imaging Temperature Screening System for Monitoring the Risk of Infectious Diseases in Enclosed Indoor Spaces)

  • 정재영;김유진
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제12권2호
    • /
    • pp.85-92
    • /
    • 2023
  • 코로나바이러스감염증-19와 같은 호흡기 감염병은 주로 밀집/밀폐/밀접 공간인 실내에서 일어난다. 호흡기 감염병 이상징후의 존재 여부는 발열, 기침, 재채기 및 호흡곤란 등의 초기 증상을 통해 판단되고 있으며, 이러한 초기 증상에 대한 상시 모니터링이 요구된다. 열화상 온도 스크리닝 시스템은 개인의 피부 온도 상승의 징후가 있는지 초기에 선별하는 빠르고 쉬운 비접촉 스크리닝 방법을 제공하지만, 측정 타겟, 주변 온도 등의 측정 환경과 피 측정대상과의 측정 거리에 따른 오차로 인해 정확한 온도측정이 어렵다. 그리고 국제표준 IEC 80601-2-59 에서는 내안각(Inner Canthus) 인접한 영역에 대한 안면 열화상 촬영을 권고하고 있다. 본 논문에서는 가시광 카메라 모듈과 열화상 카메라 모듈에 대해서 이미지 일치화 보정을 수행하였으며, 흑체(Blackbody)를 이용해 측정 환경에 대한 열화상 카메라 모듈 온도를 보정하였다. 표준에서 권고하는 측정 타겟을 인식하기 위해 딥러닝 기반 객체 인식 알고리즘과 내안각 인식 모델을 개발하였으며, 100명의 실험자군에 대한 데이터셋을 적용하여 인식 모델 정확도를 도출하였다. 또한 라이다 모듈을 이용한 객체 거리 측정과 선형회귀 보정 모듈을 통해 측정 거리에 따른 오차를 보정하였다. 제안한 모델의 성능 측정을 위해 모터 스테이지, 열화상 온도 스크리닝 시스템, 흑체로 구성된 실험환경을 구축하였으며, 1m에서 3.5m 사이 가변 거리에 따른 온도측정 결과 0.28℃ 이내의 오차 정확도를 확인하였다.

쇼핑몰의 야외성 발현 특성에 관한 연구 -공용공간 비교를 중심으로- (The Sense of Outdoor Characteristics on the Shopping Mall Planning -Focusing on Common Space Comparison-)

  • 조훈희;오준걸
    • 한국산학기술학회논문지
    • /
    • 제19권3호
    • /
    • pp.557-566
    • /
    • 2018
  • 현대 사회의 상업시설 중 쇼핑몰은 소비자의 집객과 매출을 높이기 위해 다양한 형태로 발전되어 왔다. 본 연구의 목적은 오픈형 쇼핑몰과 인클로즈드형 쇼핑몰의 공용공간에서 공통적으로 발견되는 야외성의 표출을 위한 건축계획적 특성을 비교하여 사례별 쇼핑몰의 야외성이 어떻게 구성되고 발현되는지 분석하는데 있다. 이는 다양한 프로그램이 복합적으로 집약되어 있는 쇼핑몰의 사례분석 결과를 통해 보다 쾌적한 공간계획을 위한 건축계획적 기초 연구의 토대가 된다. 결론은 다음과 같다. 첫째, 인클로즈드형 쇼핑몰 공간의 경우 오픈형 쇼핑몰에서 가지는 외부성을 표현하기 위하여 대규모 실내 공간의 구축을 통하여 야외성을 추구한다. 둘째, 인클로즈드형 쇼핑몰의 공용공간 구성방식은 기능적 가로 구성과 유기적 가로 구성의 구성으로 구분되며 입지적 특성에 따라 서로 다른 구성방식을 활용한다. 또한 공용공간은 실내공간의 제약을 극복하기 위해 지하 선큰, 내부 중정 등과 연계되어 공간의 확장 효과를 주는 것으로 분석된다. 셋째, 인클로즈드형 쇼핑몰의 건축계획적 요소들은 오픈형 쇼핑몰에서 보이는 일상성의 개념에 따라 공간의 정체성을 만들어 가며, 대규모 실내 이벤트를 위한 공간을 계획하는 것이 특징이다.

포스트 코로나 시대의 대학교 주변 원룸형 주택에 대한 실내 공기질 분석 및 위해성 평가 (An Analysis of Indoor Air Quality and Risk Assessment for One-room Housing around the University in the Post-Corona Era)

  • 포위;정재연;정인수
    • 한국농촌건축학회논문집
    • /
    • 제24권3호
    • /
    • pp.23-30
    • /
    • 2022
  • In this study, in order to grasp the current situation of indoor environmental pollution and indoor ventilation in one-room around the university in the post-corona era, we analyzed the experimental data and conducted a questionnaire survey on university students. By analyzing the content, the effects of formaldehyde, dust and other pollution on the human body, which are usually not easily detectable, are digitized and more easily taken into account. Among the experimental results, the concentration of VOC and HCHO, gas pollutants among indoor pollutants, exceeded the recommended criteria of the Ministry of Environment in most studio apartments. Overall, the average CO2 concentration was lower than the Ministry of Environment's maintenance standard (1000ppm), but it was relatively high in summer and winter, and it is believed to be caused by cooling and heating in an enclosed space. The levels of PM2.5 and PM10, particulate pollutants, increased in November and December, and it is believed that ventilation defects due to degradation in external temperature. There was no clear difference between the two types, and there was a very high correlation between PM2.5 and PM10, HCHO and VOC. It was found that temperature was closely correlated with all sources except CO2, and humidity was closely correlated with all sources except PM2.5 and PM10. Health risk assessment was conducted for formaldehyde. The average ECR of studio R2 in May was 3.91E-4, and the ECR figure in September was 3.65E-4, which was very high compared to other residential spaces. The R2 level was calculated as 4 people per 10,000 people in the lifetime risk of cancer of residents, exceeding the allowable risk. R8 also showed higher ECR results than other spaces after R2, especially in October, 2.01E-4, six times higher than R7 measured in October, and 1.87E-4 in July, four times higher than R9.

충청북도 일부지역 내 주택 실내 라돈 농도 (A Study on the Concentrations of Indoor Radon for Houses in Chungcheongbuk-do Province, Korea)

  • 지현아;유주희;김가현;원수란;김선홍;이정섭
    • 한국환경보건학회지
    • /
    • 제45권6호
    • /
    • pp.668-674
    • /
    • 2019
  • Objectives: Modern people spend most of their day indoors. As the health impact of radon becomes an issue, public interest also has been growing. The primary route of potential human exposure to radon is inhalation. Long-term exposure to high levels of radon increases the risk of developing lung cancer. Radon exposure is known to be the second-leading cause of lung cancer, following tobacco smoke. This study measures the indoor radon concentrations in detached houses in area A of Chungcheongbuk-do Province considering the construction year, cracks in the houses, the location of installed detectors, and seasonal effects. Methods: The survey was conducted from September 2017 to April 2018 on 1,872 private households located in selected areas in northern Chungcheongbuk-do Province to figure out the year of building construction and the location of detector installed and identify the factors which affect radon concentrations in the air within the building. Radon was measured using a manual alpha track detector (Raduet, Hungary) with a sampling period of longer than 90 days. Results: Indoor radon concentrations in winter within area A was surveyed to be 168.3±193.3 Bq/㎥. There was more than a 2.3 times difference between buildings built before 1979 and those built after 2010. The concentration reached 195.4±221.9 Bq/㎥ for buildings with fractures and 167.2±192.4 Bq/㎥ for buildings without fractures. It was found that detectors installed in household areas with windows exhibited a lower concentration than those installed in concealed spaces. Conclusion: High concentrations of indoor radon were shown when there was a crack in the house. Also, ventilation seems to significantly affect radon concentrations because when the location of the detector in the installed site was near windows compared to an enclosed area, radon concentration variation increased. Therefore, it is considered that radon concentration is lower in summer because natural ventilation occurs more often than in winter.

선박 환경에서 TDOA 기법에 의한 위치 추정 방법 (A Location Estimation Method Using TDOA Scheme in Vessel Environment)

  • 김범무;정민아;이성로
    • 한국정보통신학회논문지
    • /
    • 제19권8호
    • /
    • pp.1934-1942
    • /
    • 2015
  • GPS 신호가 도달하지 않은 환경에서는 실내 위치 추정 기법을 써서 추정 문제를 풀어야 한다. 일반적으로 실내 환경에서 위치를 추정하는 기법은 AOA, TOA, RSS, Fingerprint, TDOA 등이 쓰이고 있다. 그런데 철판에 의해 막힌 공간이 많은 선박의 실내 환경에서 위치 추정은 대체적으로 근거리 추정이기 때문에 TDOA 기법을 쓰는 것이 적합하다. 본 논문에서는 선박의 환경에서 단말기가 있는 위치를 추정하는 문제를 다룬다. 이를 위해 먼저 TDOA을 써서 위치를 추정하는 문제를 구체적으로 살펴보고, 다음으로 선박 환경에 적용하기 위한 알고리즘을 제안한다. 마지막으로는 세가지 관점의 모의실험을 통해 TDOA 기법에 의한 선박 내 위치 추정에 대한 타당성을 검증한다.