• Title/Summary/Keyword: Enamel roughness

Search Result 39, Processing Time 0.019 seconds

Effects of various CLEAN-UP techniques on enamel surface roughness (수종의 CLEAN-UP technique이 법랑질 표면거칠기에 미치는 영향)

  • CHO, Sang-Wan;KWON, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.791-800
    • /
    • 1997
  • Sixty premolars extracted for orthodontic treatment were divided into four groups, and the residual resin was removed with four different rotary finishing instruments at a fixed speed of $18,500{\pm}300 rpm$ on the low speed handpiece. The instruments were G1; No.169L carbide fissure bur, G2: No.2 round bur, G3; No.4 round bur, G4: No.8 round bur. Then, the enamel received a S-second polishing with a rubber cup and a pumice. To find the extent of loss on the enamel at this point, prophylaxis was done with the rubber cup and pumice prior to bonding of the bracket(P1) and removal of residual resin by means of appropriate procedure applicable to each respective group(P2) followed. The final polishing was done with the rubber cup and pumice(P3), and the enamel surface roughness was measured each by the surface measuring instrument. The whole process was observed under a scanning electron microscope to gain the following results: At P2, the enamel surface roughness in G1 showed most smoothly with $2.60{\pm}0.55{\mu}m;\;in\;G2,\;3.24{\pm}0.80{\mu}m;\;in\;G3,\;3.44{\pm}0.94{\mu}m;\;in\;G4,\;3.89{\pm}0.54{\mu}m$, the roughest. G2 and G3 showed no statistical significance(P>0.05). At P3, the enamel surface roughness in G1 showed most smoothly with $2.29{\pm}0.47{\mu}m;\;in\;G2,\;2.44{\pm}0.56{\mu}m;\;in\;G3,\;2.44{\pm}0.56{\mu}m;\;in\;G4,\;2.92{\pm}0.43{\mu}m$, the roughest. G1 vs G2, G3, and G2 vs G3 had no statistical significances(p>0.05). In all groups, P2 and P3 showed rougher in surface roughness than P1, and P2 rougher than P3(p<0.01). In a case of 5-second prophylaxis with the rubber cup and the pumice on a virgin, normal enamel, fine scratches were found under the scanning electron microscope. In all four groups, unremovable gouges remained even after polishing with the ubber and pumice; residual resin was not observed with naked eye when finished with the rubber and pumice, but the resin debris was observed under the scanning electron microscope.

  • PDF

A SEM STUDY OF RADIATION EFFECTS ON THE RAT MOLAR ENAMEL FORMATION (방사선조사가 백서 구치 법랑질형성에 미치는 영향에 관한 주사전자현미경적 연구)

  • Lee Kyung-Ho;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.409-422
    • /
    • 1995
  • The purpose of this study was to investigate the effects of radiation on the formation of rat molar enamel at the developmental stage. The experimental animals were divided into five groups and were irradiated single dose of 396cGy ; 1 st group on 14th day of gestation, 2nd group on 19th day of gestation, 3rd group on 3 days after birth, 4th group on 8 days after birth, 5th group on 28 days after birth. The control and 1, 2, 3, and 4th experimental groups were sacrificed on 2, 4, and 6 weeks and the 5th groups were sacrificed on 1 day and 2 weeks after irradiation. Distal 1/2 and occlusal 1/3 enamel surface of lingual side of lingual cusp, and fractured surface of lingual side of lingual cusp in a longitudinal direction of the mandibular first molar were examined using scanning electron microscope. The following results were obtained. 1. The roughness of enamel surface and enamel hypoplasia were increased in a sequence of 4th, 1st, 2nd, and 3rd experimental group, and the enamel cracks were increased in the 1st and 2nd experimental group. 2. The pattern of enamel hypoplasia had a network form on the 1st and 2nd experimental group, and appeared a linear shape on the 3rd experimental group, and then the crator-like enamel defects were observed in all experimental groups (especially 1st and 2nd experimental group) except 5th. 3. Dentinoenamel junction showed the clear-cut and straight appearance except 5th experimental group. 4. There was no significant difference between 5th experimental and control group.

  • PDF

EFFECT OF ETCHING TIME ON ENAMEL SURFACE ROUGHNESS: CONFOCAL LASER SCANNING MICROSCOPIC STUDY (공초점 레이저주사현미경을 이용한 산부식 시간에 따른 법랑질 표면 양상에 관한 연구)

  • Kam, Dong-Hoon;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.41-46
    • /
    • 2003
  • In order to evaluate the sufficient etching time for successful bonding and also minimizing unnecessary mineral loss, the enamel surface roughness analysis was performed using confocal laser scanning microscopy. Sixty extracted sound human molar teeth were imbedded in the center of acrylic cylinder using self-curing clear resin exposing buccal surface, and then polished with series of SiC paper(220, 500, 800, 1000, 2000, 4000 grit). Each specimen was randomly assigned to six groups(N=10). 37% phosphoric acid was applied to the polished tooth surface for 10, 20, 30, 40, 50, 60 seconds respectively and washed with copious water. After the surface roughness analysis, five roughness parameters(Sa, Sq, Sz, Sdr, Ra) were statistically analysed by ANOVA and Duncan post hoc test. We found that the all five parameters had higher roughness value in 30 seconds etching time, especially parameter Sz showed the lowest value in 10 seconds etching time and the highest value in 30 seconds etching time compared with the other etching times(p<0.05).

  • PDF

A STUDY ON THE INFLUENCE OF FLUORIDE TO ENAMEL DECALCIFICATION (불소화합물(弗素化合物)이 법랑질탈회(琺瑯質脫灰)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Kim, Yung-Hai
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.1
    • /
    • pp.173-178
    • /
    • 1988
  • The purpose of the study was to confirm the influence of fluoride to enamel decalcification. Specimens were prepared from 20 extracted teeth. Every tooth was sliced into 4 pieces by means of seperating disc. The pieces with sound enamel were distributed to 4 groups. 1st group was treated with 0.5% NaF solution for 2 minutes. 2nd group was treated with 0.5% NaF solution for 10 minutes. 3rd group was treated with 1% NaF solution for 2 minutes. 4th group was treated with 1% NaP solution for 10 minutes. The enamel surface of each specimen were decalcified with 30% $H_3PO_4$ for 2 minutes and the findings through electron microscope were as follows; 1. The degree of decalcification on the 1st group was greater than that of the 2nd group. 2. Roughness of the 3rd group was slightly higher than that of the 4th group. 3. Under the same procedure of decalcification, the specimen treated by higher conceutration of NaF solution for same length of time showed less decalcified picture. 4. Under the same procedure, of decalcification, the specimens treated by same concentration of NaF solution for different length of time, were compared and found longer the time less decalcified.

  • PDF

Regeneration of a Micro-Scratched Tooth Enamel Layer by Nanoscale Hydroxyapatite Solution

  • Ryu, Su-Chak;Lim, Byoung-Ki;Sun, Fangfang;Koh, Kwang-Nak;Han, Dong-Wook;Lee, Jae-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.4
    • /
    • pp.887-890
    • /
    • 2009
  • Hydroxyapatite (HAp)-based materials have attracted considerable attention on account of their excellent stability and recrystallization. Nanoscale HAp powders with a mean particle size of 200 nm were used to regenerate the enamel layers of damaged teeth. An artificially scratched tooth was immersed in a nanoscale HAp powder suspension in d.i. water (HAp of 70 wt%) at 37 ${^{\circ}C}$ for a period of 1~3 months. SEM and AFM showed that the scratched surface was ultimately inlaid with HAp after three months and the roughness increased from 2.80 to 5.51. Moreover, the hardness of the neo-generated HAp layer on the crown was similar to that of the innate layer. $Ca^{2+}$ and ${PO_4}^{3-}$ ions from the HAp powders dissolved in d.i. water were precipitated on the tooth to produce cemented pasteson the enamel surface due to its high recrystallizing characteristics, resulting in a hard neo-regenerated HAp layer on the enamel layer. This nanoscale HAp powder solution might be used to heal decayed teeth as well as to develop tooth whitening appliances.

Effect of Fluoridated 10% Carbamide Peroxide on Enamel Surface Change and Whitening (불소를 첨가한 10% Carbamide Peroxide의 법랑질표면 변화와 미백효과)

  • Lee, Hye-Jin;Kim, Hyun-Dae;Kim, Min-Young;Kwon, Tae-Yub;Kim, Kyo-Han
    • Journal of dental hygiene science
    • /
    • v.10 no.2
    • /
    • pp.95-100
    • /
    • 2010
  • The purposes of this study were to examine the effect of different fluoridated bleaching solution on the changes in physical and chemical characteristics of tooth. Forty-eight bovine incisors were divided into four groups to receive bleaching treatments, over a 14days period, as follows: no treatment; 10% carbamide peroxide (CP) bleaching; 10% CP containing 0.05% fluoride; and 10% CP containing 0.1% fluoride. All the specimens were highly polished and discolored with commercial COCK.Color and enamel changes were determined with colorimeter, microhardness tester, scanning electron microscope, atomic force microscopy. All the collected data were analyzed with one-way ANOVA. After the bleaching, bleached groups showed the color change(E*). Microhardness of 10% CP group decreased after tooth bleaching. But microhardness of containing fluoride bleached groups increased after tooth bleaching. Enamel surface of 10% CP bleached group showed any apparent morphology and roughness changes compared to the enamel which was stored in distilled water only. These results demonstrated that Fluoridated 10% Carbamide Peroxide have appreciable bleaching effect on bovine teeth and were not adversely affects enamel. Supporting influence of fluoride-containing bleaching solution on remineralization could be observed and further research must be carried out in various active environments to confirm these results clinically.

EFFECTS OF PHOSPHORIC ACID CONCENTRATION ON DEPTH OF ETCH AND SHEAR BOND STRENGTH OF ORTHODONTIC BRACKETS TO BOVINE ENAMEL (인산농도가 소의 법랑질에서 부식깊이와 브라켓 전단결합강도에 미치는 영향)

  • Kim, Soo-Cheol;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.25 no.3 s.50
    • /
    • pp.341-353
    • /
    • 1995
  • Previous study had shown the diversities in the propriety for optimal bond strength on the concentration of the etchant. The aim of present study in vitro was to evaluate and compare the shear bond strength of orthodontic brackets to enamel and to measure the depth of etch on the phosphoric acid concentrations. A hundred and seventy six extracted bovine lower centrals were ground to yield flat surfaces and etched by the concentration $0%,\;5%,\;10%,\;20%,\;30%,\;40%,\;50%,\;60%,\;70%,\;80%\;and\;85\%$ of phosphoric acid respectively during 60 seconds. The shear bond strength of orthodontic brackets, the depth of etch and surface roughness of the enamel were measured, and scanning electron microscopic observations on the etched enamel surfaces were carried out. The data obtained from the very experiments were processed and statistically analyzed and evaluated. The gradual increase in the depth of etch to enamel as the accretion of the concentration of the phosphoric acid upto $40-50\%$ and decline henceforth were manifested. The surface roughness showed no correlation with the depth of etch, yet moderate correlation with the shear bond strength of brackets. Scanning electron microscopic investigation revealed that morphological patterns of the etched enamel surfaces for $5\%\;to\;40\%$ of concentrations were even and homogenous, and those for $50\%$ as well as $60\%$ exhibited the overetched and unhomogenous. The shear bond strengths kom $10\%\;to\;60\%$ of concentration showed no statistically significant differences. It was suggested that the shear bond strengths at $5\%\;and\;70\%$ were sufficient to tolerate the force levels of the ordinary orthodontic treatment notwithstanding to be significantly lower than those from $10\%\;to\;60\%$ phosphoric acid solution.

  • PDF

Comparison in Demineralization Resistance of Resin Infiltration and 1.23% Acidulated Phosphate Fluoride in Bovine Teeth (우치에서 레진 침투법 및 불소 적용의 탈회 저항성 비교)

  • Lee, Doo-Young;Kim, Ik-Hwan;Song, Je Seon;Kim, Seong-Oh;Son, Heung Kyu;Lee, Jaeho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.2
    • /
    • pp.137-143
    • /
    • 2018
  • The aim of this study is to compare the differences of the demineralization resistance of resin infiltration and 1.23% acidulated phosphate fluoride in bovine teeth with artificial caries. We applied 1.23% Acidulated phosphate fluoride (APF) gel and $Icon^{(R)}$ caries infiltrant on the artificial bovine enamel carious lesion and then demineralized all samples. The depth of demineralization was measured by using Confocal Laser Scanning Microscope (CLSM) and observed the roughness and irregularity of the enamel was observed by Scanning Electron Microscope (SEM). In this experiment with demineralization resistance on smooth artificial carious lesion, less depth of demineralization, roughness, and irregularity of enamel was observed in APF gel and $Icon^{(R)}$ group than in the control group. There was no significant difference between the depth of demineralization of 1.23% APF gel and $Icon^{(R)}$ caries infiltrant group. However, resin infiltration is beneficial as less roughness and irregularity was observed on the enamel surface than when 1.23% APF gel is applied.

AN IN-VITRO WEAR STUDY OF DENTAL PORCELAINS AND HUMAN ENAMEL (치과용도재에 의한 법랑질 마모에 관한 연구)

  • Lee, Young-Kook;Lee, Sun-Hyung;Yang, Jae-Ho;Chung, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.1
    • /
    • pp.51-70
    • /
    • 1999
  • Dental porcelain is one of the materials of choice for restoration where esthetics is of concern, but has a considerable potentials of wear. The wear of enamel is variable when opposed by different porcelain systems and surface conditions, and the exposed dentine and opaque porcelain due to clinical failure is expected to have high potentials of wear. The purpose of this study was to investigate the wear effects of self-glazed, polished incisal porcelain. polished dentine and opaque porcelain against human enamel in the laboratory by use of a pin-on-disk type wear tester. 4 types of dental porcelain($Vita-{\Omega}$, Ceramco-II, Vintage powder $Vita-{\alpha}$ of In-Ceram system) and type IV gold alloy as cotrol group were used for test specimens. Intact buccal cusps of maxillary premolar were used for enamel specimens, and the cusp converged to a point and was devoid of visible abrasion, caries, decalcification. The upper part was the cusp of a maxillary premolar and the lower part was a porcelain specimen. The enamel wear was deter-mined by weighing the cusp before and after each test. Surface profilometer was used to quantitate wear of the porcelain specimens. Vicker's hardness tester was used to evaluate the surface hardness of test specimens. The SEM was used to evaluate the wear surfaces. The results were as follows : 1 Self-glazed porcelain produced more enamel wear than polished porcelain, especially the enamel wear of $Vita-{\alpha}$ self-glazed porcelain was 3.2 times more than that of other groups. 2. Opaque porcelain produced least porcelain wear, $Vita-{\alpha}$ self-glazed porcelain produce greatest porcelain wear, but there was no statistically significant difference between the groups(p>0.05). 3. The enamel wear of dentine porcelain was 3.8 times more than that of polished inisal porcelain(p<0.05), and the enamel wear of opaque porcelain was 1.9 times more than that of polished inisal porcelain, but there was no statistically significant difference between the groups(p>0.05) 4. Overglazed porcelain produced less enamel wear than self-glazed porcelain, and more enamel wear than polished porcelain, but there was no statistically significant difference between the groups(P>0.05). 5. The hardness number of $Vita-{\Omega}$ dentine and Ceramco-II opaque porcelain was larger, but that of Vintage dentine and $Vita-{\alpha}$ self-glazed porcelain was similar to other groups. 6. Examination of SEM photographs revealed that overglazed porcelain had smoother surface than self-glazed porcelain, and self-glazed porcelain had smoother surface than polished porcelain. Much polishing scratches and larger porosities were observed on the opaque porcelain specimen, and much polishing scratchess and small porosities were observed on the dentine porcelain specimen.

  • PDF

SURFACE ANALYSIS OF CERCE RESTORATIONS POLISHED BY DIFFERENT TECHNIQUE (연마방법에 따른 Cerec block의 표면 거칠기 비교)

  • Kim, Sung-Gwang;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.1
    • /
    • pp.31-42
    • /
    • 1997
  • This study was performed to investigate the surface roughness of the Cerec Vita Mark II polished by various polishing techniques, compare with that of the Vintage enamel porcelain glazed by high temperature glazing technique. All of the Cerec specimen were finished with sequential use of high speed diamond burs(grit 45, 30 and $15{\mu}m$). The groups were divided into 5 groups : Group I : Cerec Vita Mark II block specimens polished with Sof-lex discs. Group II : Cerce Vita Mark II block specimens polished with Two Striper MPS. Group III : Cerce Vita Mark II block specimens polished with Enhance. Group IV : Cerce Vita Mark II block specimens polished with Porcelain laminate polishing FG kit. Group V : Vintage enamel porcelain glazed by high temperature glazing Technique. Each group was consisted of 10 specimens. The surfaces produced were examined quantitatively using a laser specular reflectance machine(Perthen RM600-s, Feinpruf Perthen GmbH., Germany) and qualitatively under SEM(JSM-5400, JEOL, Japan). The Results were as follows : 1. The arithmetic mean roughness value(Ra) in groups 1, 2, 3 and 4 was higher than that of group5. There was statistically significant difference(P<0.05). 2. The arithmetic mean roughness value(Ra) decreased in the following orders : group 1, group 2, group 4, group 3 and there was no statistically significant difference between group 1 and group 2, group 3, and group 4. There was statistically significant difference among group 1, 2, and group 3, 4 and group 5(P<0.05). 3. The maximum individual peak-to-valley-height(Rmax) decreased in the following orders : group 2, group 1, group 4, group 3, group 5 and there was no statistically significant difference between group 1 and 2, group 1 and group 4, group 3 and group 5. There was statistically significant difference among group 1, 2, and group 1, 4 and group 3, 5(P<0.05). 4. The treated surfaces of group 5 had smoother surface than that of groups 1, 2, 3, 4 with SEM.

  • PDF