• Title/Summary/Keyword: Enamel coating

Search Result 34, Processing Time 0.025 seconds

Interfacial Adhesion Properties of Enamel-coated Alloyed Steels (법랑 처리된 합금강판의 계면밀착특성 연구)

  • Yoon, Jeong Bong;Cho, Hang Sik;Park, Yeong-Do;Kim, Yangdo;Kim, Young-Seok;Nam, Dae-Geun;Oh, Weontae
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.3
    • /
    • pp.235-240
    • /
    • 2010
  • The interfacial adhesion properties of enamel-coated, alloyed steels were in detail characterized by spectroscopic techniques. The surfaces of alloyed steels existed as oxidized states of $Fe_3O_4$. Therefore, the oxidized surfaces of the steels significantly interacted with the coated enamels for the adhesion. Ti-alloyed steel showed many micro-boundaries during thermal treatment and these micro-boundaries might cause the decline of the interfacial adhesion between enamel and steel. The depth profiles of enamel-coated, alloyed steels were investigated by GDS (glow discharge spectroscopy) and Ti component was found to be related to the interfacial adhesion between enamel and steel.

An Innovative Solution for the Power Quality Problems in Induction Motor by Using Silica and Alumina Nano Fillers Mixed Enamel for the Coatings of the Windings

  • Mohanadasse, K.;Sharmeela, C.;Selvaraj, D. Edison
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1621-1625
    • /
    • 2015
  • Power quality has always been a concern of power engineers. Certainly an argument can be successfully made that most parts of power engineering have the ultimate objective to improve power quality. AC motors were widely used in industrial and domestic applications. Generally, AC motors were of two types: Induction and Synchronous motors. In motor many parameters like different load cycling, switching, working in hot weather and unbalances creates harmonics which creates major reasons for temperature rise of the motors. Due to high peak value of voltage, harmonics can weaken insulation in cables, windings and capacitors and different electronic components. Higher value of harmonics increase the motor current and decrease the power factor which will reduce the life time of the motor and increase the overall rating of all electrical equipments. Harmonics reduction of all the motors in India will save more power. Coating of windings of the motor with nano fillers will reduce the amount of harmonics in the motor. Based on the previous project works, actions were taken to use the enamel filled with various nano fillers for the coating of the windings of the different AC motors. Ball mill method was used to convert the micro particles of Al2O3, SiO2, TiO2, ZrO2 and ZnO into nano particles. SEM, TEM and XRD were used to augment the particle size of the powder. The synthesized nano powders were mixed with the enamel by using ultrasonic vibrator. Then the enamel mixed with the nano fillers was coated to the windings of the several AC motors. Harmonics were measured in terms of various indices like THD, VHD, CHD and DIN by using Harmonic analyzer. There are many other measures and indices to describe power quality, but none is applicable in all cases and in many instances, these indices may hide more than they show. Sometimes power quality indices were used as a basis of comparison and standardization. The efficiency of the motors was increased by 5 – 10 %. The thermal withstanding capacity of the motor was increased by 5º to 15º C. The harmonics of the motors were reduced by 10 – 50%.

ANTICARIOGENIC EFFECT OF FLUORIDE RELEASED FROM SEALANT COMPARED TO TOPICAL FLUORIDE APPLICATION METHODS (국소적인 불소도포제재와 불소유리 치면열구전색재의 내산성 효과)

  • Park, Ki-Tae;Shon, Heung-Kyu;Chai, Byung-Jai;Park, Kwang-Kyun;Shon, Dong-Su;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.1
    • /
    • pp.148-172
    • /
    • 1997
  • Sixty human premolar teeth were used for this in vitro study. After each tooth was sectioned mesiodistally, one half was used for the experimental group and the other half for the control. Three groups were made for each fluoride applying method and twenthy teeth were assigned to each group. Ten teeth were used for evaluating total fluoride amount and the other ten were used for firmly-bound fluoride. Fluorshield was used for fluoride-releasing sealant and 1.23% APF, 0.05% NaF were used for topical application fluorides. Each tooth was cleaned with a tooth brush using nonfluoride containing pumice before the experiment. In the sealant group, fluoroshield was applied to the enamel surface without etching procedure and stored in $37^{\circ}C$ saline for 30 days. After 30 days, sealant was removed with explorer without scratching the enamel surface and washed with distilled water and dried. In the APF group, each tooth was immersed in 1.23% APF for 30 min then washed and dried in the same manner. In the NaF group, each tooth was immersed in 0.05% NaF for 24 hours then washed and dried as described above. After each fluoride regimen was applied, ten teeth were randomly selected from each group and immersed in 1M KOH solution for 24 hours to remove loosely-bound fluoride possibly deposited by the three different fluorides applied. In each group, total fluoride amount deposited and the amount of enamel removed by acid biopsy were calculated. After loosely-bound fluoride was removed, firmly-bound fluoride deposited and the amount of enamel removed by acid biopsy were also calculated. Total fluoride amount deposition was significantly increased in the APF and NaF groups, but not in the sealant group. Amount of enamel removed by acid-biopsy was also significantly diminished in the APF and NaF groups, but not in the sealant groups. After loosely-bound fluoride was removed from each groups, no statistical difference was found in the amount of firmly-bound fluoride in any groups. Also no effect of firmly-bound fluoride on enamel dissolution was shown in any groups after loosely-bound fluoride was removed from each group. In conclusion, topical application method of APF or NaF is more effective than fluoride-releasing sealant application to make $CaF_2$ coating on enamel surface and $CaF_2$ coating is the main source for anticariogenic effect of fluoride. However, longterm anticariogenic effect of fluoride-releasing sealant should be further evaluated.

  • PDF

Corrosion protection of magnesium alloys by organic coatings

  • Fazal, Basit Raza;Moon, Sungmo
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.194.2-194.2
    • /
    • 2016
  • Magnesium has many desirable properties of which the high strength/weight ratio makes it extremely valuable in automobile and aerospace industry. However, the high corrosion susceptibility of magnesium and its alloys has greatly limited their large scale use for various applications. Organic coating is one of the most effective ways to prevent magnesium alloys from corrosion. An organic coating is normally used in the final stage of a coating process. It can enhance corrosion resistance of magnesium and its alloys. Organic coating involves a variety of process such as painting, powder coating, cathodic electrocoating (E-painting) and the application of lacquers, enamel and varnishes.

  • PDF

Measurement Feasibility Assessment of Coating Film Thickness using Dual Sensor (이중센서를 이용한 코팅막 두께 측정 가능성 평가)

  • 김주현;김성렬;김정욱;김화영;안중환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.78-81
    • /
    • 2004
  • A technical performance of the coating depends greatly on the thickness of painting film or coating film. Therefore the confirmed report of the technique to measure accurately is essential to the coating film thickness for the assessment about a coating quality performance. In this paper, two gap sensors - eddy current gap sensor and capacitance gap sensor - which has a different operating principle were used to measure the thickness of a nonmagnetic substance coating film such as paint, enamel or ceramic that was coated on the metallic material. A capacitance gap sensor was used to measure the distance between the sensor head and a coating film and an eddy current gap sensor to measure the distance between the sensor head and a base metal. Then the thickness of a coating film was obtained by the difference of two measurement value. At this result, the suggested dual sensor can measure an arbitrary film thickness to be coated on a base metal as the measurement value of coating thickness exists accurately within the 2% error.

  • PDF

Separation of Enamel from the Enamel Coated Coper Wires Via High Frequency Induction Process (에나멜코팅된 구리코일로 부터의 친환경적(親環境的) 구리선의 분리(分離))

  • Song, Yong-Ho;Kim, Jeong-Min;Park, Joon-Sik;Kong, Man-Sik;Lee, Caroline Seun-Young
    • Resources Recycling
    • /
    • v.21 no.3
    • /
    • pp.48-55
    • /
    • 2012
  • Recently, the recycling with environmentally friendly method has been an issue for various fields. An effective removal method of coating layers from coated copper wires is one critical factor for recycling copper wire. We have adopted a high frequency heating routine for removing the coating layers on the coated copper wires, and attempted to find optimum conditions. The experimental results show that the copper wires should be maintained at or above $950^{\circ}C$ for rapid removal of the polyester. The simulation and experimental results are discussed with respect to the microstrucrual evolution during heating of the copper wires.

Coating of two kinds of bioactive glass on Ti6Al4V alloy (Ti6Al4V 합금에 두 종류의 생체활성화 유리 코팅)

  • Kang, Eun-Tae;Lee, Nam-Young;Choi, Hyun-Bin
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.28 no.5
    • /
    • pp.206-210
    • /
    • 2018
  • Two kinds of bioactive glass were coated on the Ti6Al4V alloy by the enameling technique. In order to reduce the thermal stress due to the difference in expansion coefficient with the alloy with the secondary coating forming hydroxyapatite, the difference in expansion coefficient between the alloy and the two glasses was adjusted at $2{\times}10^{-6}/^{\circ}C$ intervals. FE-SEM and EDS analysis showed that good adhesion was formed between the Ti6Al4V alloy and the primary coating by diffusion bonding. After immersion in SBF solution, it was confirmed from FT-IR that hydroxycarbonate apatite formed in the secondary coating was not different from bulk bioactive glass.

RESIN TAG FORMATION OF SELF-ETCHING ADHESIVES (자가부식 접착제의 레진 Tag 형성)

  • Kim, Young-Jae;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.143-152
    • /
    • 2003
  • The aims of the present study was to observe resin tag of the resin/enamel, dentin interface produced by self-etching adhesive systems and evaluate effect of additional acid etching on resin tag formation. Three self-etching primer(SE bond, AQ bond and L Pop) and an one bottle adhesive(Single bond) were used. Flat occlusal enamel and dentin disks were obtained from extracted human molars. A total of 20 surfaces were collected and divided into four groups of 5 samples. One-half of each specimen in each group was etched with 35% phosphoric acid prior to the application of each adhesive system, with the second half being kept unetched. Subsequently, resin composite was placed and polymerized. The samples were sliced and immersed into HCl and NaOCl solutions, followed by drying and sputter coating for examination with a SEM. The results were as follows; 1. Additional etching side of dentin displayed longer and thicker resin tag than unetched side in all self-etching adhesive groups. 2. In enamel, additional etching side displayed deeper and more distinct etching pattern than unetched side except L Pop. There is no difference between etched and unetched enamel in L Pop. The results obtained suggest the self-etching adhesive did not etch enamel and penetrate into dentinal tubule as deeply as did additional etching. Further research should include the evaluation of the relationship of boding strength, microleakage and resin tag morphology.

  • PDF

Evaluation of the Properties of Wrapping Material of Steel Pipe for Water Supply (수도용 강관의 도복장 재료특성 평가에 관한 연구)

  • Lee, Hyun-Dong;Lee, Ji-Eun;Kwak, Phill-Jae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.3
    • /
    • pp.331-338
    • /
    • 2008
  • Coal-tar enamel, blown asphalt and polyethylene have been used as wrapping materials of steel pipe in Korea. Currently, every manufacturer produces wrapped steel pipes with different materials and methods, and little research has been performed to get on wrapping methods and materials. In this research, properties of wrapping material of steel pipe used for water supply have been evaluated. All of the materials tested in this work were found to meet the standard. Among the wrapping materials of steel pipe tested, blown asphalt and coal-tar enamel were reasonable in price, and their mechanical properties were excellent. The quality of the wrapped steel pipes was being melted easily in organic solvent. When coated thick, the load of the steel pipes was higher than necessary. Tensile strength of cathode exfoliation and PE 3-layer wrapping method was excellent. The pulling intensity of T-Die PE 3-layer was stronger than PE fluidized in PE wrapping method. Cathode exfoliation area was smaller than PE fluidized. Mechanical property and thermo-property of T-Die PE 3-layer were excellent and its anti-chemical property was great. Liquid epoxy can change the property of coating materials depending on the hardening condition and resin selection. Polyurethane used in this test showed a less adhesive strength with steel pipes than epoxy. Moisture absorbance rate was higher than Epoxy's, however. To utilize polyurethane as wrapping materials, basic property of the matter should be improved followed by finding the best suited coating condition. The method of PE 3-layer by extrude method appeared to be the best in this study. However, identification of other wrapping materials requires further additional tests.

A COMPARISON OF FLUORESCENCE EFFECT OF VARIOUS LIGHT SOURCES IN EARLY ENAMEL CARIES (초기 우식 병소에서 광원에 따른 형광효과 비교)

  • Jeon, Jeong-Hoon;Lee, Nan-Young;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.4
    • /
    • pp.611-619
    • /
    • 2005
  • The aim of this study was to apply the quantitative light-induced fluorescence(QLF) and use of fluorescein-enhanced QLF method for quantitative assessment of early enamel demineralization in vitro, comparing effectiveness of light sources : argon laser, halogen lamp, light emitting diode (LED) and plasma arc lamp. Sixty extracted teeth were used, prepared by gentle pumicing and coating in an acid-resistant nail-varnish, except for an exposure to a demineralizing solution. Teeth were removed at regular intervals (24, 48 and 72hrs), air-dried and QLF image were taken. Mineral loss, as measured by difference of optical density, was recorded. For dyeenhanced QLF a 0.075% sodium fluorescein dye was applied after QLF examination and mineral loss was recorded. The following result were obtained : 1. Comparing with mean difference of optical density, plasma arc lamp was higher than other light sources in all group (p<0.05). 2. Comparing each group with mean difference of optical density, there was significant different using plasma are lamp and halogen lamp. 3. For use of dye-enhanced QLF, comparing with mean difference of optical density, plasma arc lamp were higher than other light sources in all group(p<0.05). 4. With this model dye-enhanced QLF compared with QLF in optical density, dye-enhanced QLF was higher than QLF in optical density. From the results presented in this paper, it was concluded that plasma light source was more effective compared with other light source for the detection and the quantification of early enamel caries.

  • PDF