• Title/Summary/Keyword: Emssion factor

Search Result 4, Processing Time 0.017 seconds

A Study on the Relationship of Air Pollution and Meteorological Factors : Focusing at Kwanghwamun in Seoul (대기오염농도와 기상인자의 관련성 연구: 서울 광화문지점을 중심으로)

  • 신찬기;한진석;김윤신
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.4
    • /
    • pp.213-220
    • /
    • 1992
  • Simple correlation analysis, factor analysis, and multi-variate analysis have been performed to analyze the relationship between air pollution and meteorological factors for air pollution and meteorological data measured at Kwanghwamun in Seoul during the period of one year(January 1990 $\sim$ December 1990). As a result of simple correlation and factor analysis, $SO_2$, TSP and CO concentrations have shown high negative correlation with temperature and among these indicating that these are related with pollutant emission trend based upon heating fuel usage. Ozone has a good corrleation with solar radiation and relative humidity to have a closed relation with $O_3$ generation reaction mechanism. The result of multi-variate correlation analysis shows that the concentration of $SO_2$ and CO are adequate for correlation model with ambient temperature and wind speed and $O_3$ concentrations are adequate for that with solar radiation and wind speed. $SO_2$ and CO levels are considered to be affected first of all by heating fuel usage as a emssion source and wind speed as a dispersion effect. The $SO_2$ concentration in the condition that the temperature fall below zero is explained by multilicative model with wind speed, only one variable.

  • PDF

A Study on the Comparison of Measuring Methods and Development of Emssion Factor on Mercury from Large-Scale Emission Sources (대형배출원에서의 수은 측정방법 비교 및 배출계수 개발에 관한 연구)

  • Kim, Hyung-Chun;Kim, Rhok-Ho;Kim, Jong-Hyeon;Lim, Seung-young;Kang, Dae-Il;Hong, Ji-Hyung;Jang, Kee-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.2
    • /
    • pp.184-192
    • /
    • 2016
  • Recently, studies on reducing mercury have been actively conducted worldwide, which include the current status of mercury emissions and mercury control technology. Among the control technology, Sorbent Trap measurement method has been aggressively developed due to its reliability, easiness in measurement and analysis. The purpose of this study is to evaluate the applicability of the new international measurement method; Sorbent Trap. For this, the study compared the Sorbent trap method (US EPA Method 30B) and the Korean Standard Method for Examination of Air (ES 01408.1) to evaluate their reliability, and developed mercury emission factors. As the result, the relative standard deviations (% RSD) of the two methods were 3.5~13.4% at Coal-fired Power Plants (CPP), 4.0~18.4% at Cement Kilns (CK), and 3.0~11.3% at Medical Waste Incinerators (MWI). The emissions factors were developed as 14.50 kg/ton at CPP, 45.10 kg/ton at CK, and 1,290.2 kg/ton at MWI.

A Study on Process Integrated Innovation System for a LNG Industry (휘발성 유기화합물의 배출량 산정 및 관리 소프트웨어 개발)

  • Yi Jonghyeop;Park Hyeonsoo;Lee Sunwoo;Kim Hwayong
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.2 s.19
    • /
    • pp.7-13
    • /
    • 2003
  • Abstract This paper presents new emission mechanism and emission estimation model in volatile organic compounds(VOCs) emission sources. Also classifies applicable emission reduction techniques and presents new economical evaluation method for each techniques. We ultimately developed VEER(VOCs Emission Estimation and Reduction) software, which is backed by above mentioned model, emission source DB, Chemical properties DB, meteorological DB, and emission factor DB. With VEER, users in enterprise, central government and local self-governing body can get reliable emission results easily, and choose suitable emission reduction techniques.

  • PDF

Estimating PM Emission Factor from Coal-Fired Power Plants in Korea (화력발전소에서의 국내 배출계수 산정 방안 연구 -먼지를 중심으로-)

  • Jang, Kee-Won;Kim, Hyoung-Chun;Lee, Yong-Mi;Song, Deok-Jong;Jung, No-El;Kim, Sang-Kyun;Hong, Ji-Hyung;Lee, Suk-Jo;Han, Jong-Su
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.485-493
    • /
    • 2011
  • In Korea, PM (Particulate Matter) emissions caused by coal-fired power plants are measured by a system, so called Clean Air Policy Support System (CAPSS), which uses foreign emission factors. However, the system fails to reflect the characteristics of domestic power plants. In this regard, this study aims to develop local, accurate domestic emission factors. The study measured the amount of TSP (Total Suspended Particulates), PM10 and PM2.5 by collecting samples from the latter parts of pollution control devices which were installed at 3 bituminous-fired power plants and 3 anthracite-fired power plants. The results showed that the average concentrations of TSP, PM10 and PM2.5 measured at bituminous-fired power plants were 4.63 mg/$Sm^3$, 2.96 mg/$Sm^3$ and 3.07 mg/$Sm^3$ respectively, much higher than those from anthracite-fired power plants (2.96 mg/$Sm^3$, 2.47 mg/$Sm^3$ and 1.37 mg/$Sm^3$, respectively). In addition, bituminous-fired power plants showed higher ratios of PM10/TSP and PM2.5/TSP with 0.66 and 0.92, respectively, compared to 0.82 and 0.46, the ratios of PM10/TSP and PM2.5/TSP measured in anthracite-fired power plants. Emission factors based-on concentration measurements were also higher for bituminous-fired power plants, and PM with smaller particles tended to have bigger difference in emission factors between the two fuels. This study calculated the amount of PM emissions by using the estimated emission factors. When it comes to the PM emissions, it was less than that of CAPSS while similar to that of CleanSYS in its amount. It is expected that the emission factors developed by this study will be used in Korea replacing foreign emission factors currently used in Korea by ensuring the objectivity and reliability as domestic emission factors.