• 제목/요약/키워드: Empress 2 crown

검색결과 37건 처리시간 0.028초

즉시 Frialit-2 implant 식립, 즉시 임시치관 제작 그리고 IPS Empress 2 crown을 이용한 상악중절치의 심미적 수복 (Esthetic reconstruction of upper central incisor using immediate Frialit-2 implant placement, immediate temporary crown fabrication and IPS Empress 2 crown)

  • 김유리;오상천
    • 구강회복응용과학지
    • /
    • 제19권1호
    • /
    • pp.43-48
    • /
    • 2003
  • During the past several years, significant advances have occurred in the utilization of osseointegrated implants for the treatment of partially edentulous patients. One of the biggest purposes for treating of these patients is the high demand for improved esthetics, especially in the anterior region. For this esthetics, the new trend in dental implants is the immediate placement and immediate superstructure fabrication. The refined surgical technique, the skillful soft tissue management, and the proper prosthetic coordination are the main factors to achieve natural looking of implant supported prosthesis. The customized provisional restoration and the customized impression coping are recommended for the optimal peri-implant soft tissue contour. The basic concept of Frialit 2 system was the immediate replacement of a tooth with root-analog fixture after extraction. This system guarantees an ideal result in function and esthetics. The ceramic abutment system offers improved quality in the respect of esthetics, fitness, translucency, and biocompatibility. In this clinical report, the final restoration made with IPS Empress 2 crown on the CeraBase abutmen of Frialit 2 system allowed the reproduction of the natural vitality of tooth and adjacent gingiva.

IPS-Empress 도재관의 변연형태에 따른 파절강도에 관한 연구 (A STUDY ON THE FRACTURE STRENGTH OF THE IPS-EMPRESS CERAMIC CROWN ACCORDING TO MARGIN TYPE)

  • 김현수;주태훈;오상천;동진근
    • 대한치과보철학회지
    • /
    • 제35권2호
    • /
    • pp.296-307
    • /
    • 1997
  • The purpose of this study was to compare the fracture strength of the IPS-Empress ceramic crown according to margin types such as bevel, shoulder, rounded shoulder, shoulder with bevel, rounded shoulder with bevel and bevel with groove. After 10 metal dies were constructed for each group, the IPS-Empress ceramic crown were fabricated and each crown was cemented on each metal die with Bistite resin cement. The cemented crowns mounted in the testing jig were inclined 30 degree and universal testing machine (Zwick 1456 41, Zwick Co., Germany) was used to measure the fracture strength. The obtained results were as follows : 1. The fracture strength of the crown with rounded shoulder was the highest of all. The mean fracture strength was 484N in rounded shoulder, 357N in bevel, 341N in rounded shoulder with bevl, 300N in shoulder with bevel, 280N in shoulder and 275N in bevel with groove. 2. The fracture strength of rounded shoulder was statistically different from those of shoulder with bevel, shoulder and beve41 with groove. 3. In the strain at fracture, there was no significant difference among each group. 4. The fracture mode of the crown was similar and most of fracture line began at the loading area and extended through proximal surface perpendicularly to the margin, irrespective of margin type.

  • PDF

IPS Empress 도재관의 파절강도 : 상악 중절치에서 절단연 삭제량과 축면 경사도에 따른 영향 (Fracture strength of the IPS Empress crown :The effect of incisal reduction and axial inclination on upper central incisor)

  • 송병권;이해형;동진근
    • 구강회복응용과학지
    • /
    • 제16권3호
    • /
    • pp.237-245
    • /
    • 2000
  • The purpose of this study was to compare the fracture strength of the IPS Empress ceramic crown according to the incisal depth(2.0mm, 2.5mm, 3.0mm) and axial inclination($4^{\circ}$, $8^{\circ}$, $12^{\circ}$) of the upper central incisor. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and each crown was cemented on each metal die with resin cement. The cemented crowns mounted on the testing jig were inclined 30 degrees and a universal testing machine was used to measure the fracture strength. The results were : 1. The fracture strength of the ceramic crown with 2.5mm depth and $8^{\circ}$ inclination was the highest(965N). Crowns of 2.0mm depth and $4^{\circ}$ inclination had the lowest strength(713N). There were no significant differences of the fracture strength by axial inclination in same incisal depth group. 2. The fracture mode of the crowns was similar. Most of fracture lines began at the loading area and extended through proximal surface perpendicular to the margin irrespective of incisal depth. There had correlation between fracture strength and fractured surface area.

  • PDF

IPS Empress 도재관의 파절강도 : 하악 견치에서 절단연 삭제량과 축면 경사도에 따른 영향 (Fracture Strength of IPS Empress Crown : The Effect of Incisal Reduction and Axial Inclination on Lower Canine)

  • 정영찬;신동국;박은주;김민정;동진근
    • 구강회복응용과학지
    • /
    • 제20권1호
    • /
    • pp.19-29
    • /
    • 2004
  • The purpose of this study was to compare the fracture strength of the IPS Empress ceramic crown according to the incisal reduction(2.0mm, 2.5mm, 3.0mm) and axial inclination ($4^{\circ}$, $8^{\circ}$, $12^{\circ}$) of the lower canine. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and each crown was cemented on each metal die with resin cement. The cemented crowns mounted on the testing jig were inclined 30 degrees and a universal testing machine was used to measure the fracture strength. The results of this study were as follows : 1. The fracture strength of the ceramic crown with 3.0mm depth and $12^{\circ}$ inclination was the highest(1377N). Crowns of 2.0mm depth and $4^{\circ}$ inclination had the lowest strength (731 N). 2. There were no significant differences of the fracture strength by axial inclination in same incisal reduction group. 3. The fracture mode of the crowns was similar. Most of fracture lines began at the loading area and extended through proximal surface perpendicular to the margin irrespective of incisal reduction.

전부도재관에 사용되는 레진시멘트의 색안정성에 관한 연구 (THE STUDY ON THE COLOR STABILITY OF RESIN CEMENT USED IN ALL CERAMIC CROWN)

  • 이태희;이영수;박원희
    • 대한치과보철학회지
    • /
    • 제42권1호
    • /
    • pp.41-48
    • /
    • 2004
  • Statement of problem : The Cement as well as restoration required esthetics for making natural color restoration. Purpose : The purpose of this research is to evaluate color stability of restoration intermediated by resin cement which is used for cementation of all ceramic crown. Material and method : After making Empress 2 ingot into the size of $10mm{\times}10mm{\times}1mm$ according to indication, it glazed and made 48 Empress 2 blocks. Three kinds of resin cement(Rely-X, Variolink 2, Choice) having same shade cemented between Empress 2 blocks and Ivory shade tiles and made 48 specimens in the thickness of $30{\mu}m$ and $80{\mu}m$. After measureing color difference using spectorphotomenter, the result of this study were as follows. Results : The color difference of resin cement used in experiment increased in the order Rely-X, Variolink 2. As the thickness of cement increases, the color difference of all kinds of cement found statistically sifnificant difference but, this result is clinically acceptable. Conclusion : More resarch would have to be done in order to decrease the color difference as cement's thickness.

구치용 도재소부금관과 전부도재관에 파절을 일으키는 한국음식에 관한 연구 (A comparative study on the correlation between Korean foods and the fractures of PFG and all ceramic crowns for posterior applications)

  • 김정호;이재봉
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.156-163
    • /
    • 2009
  • 연구목적: 4종 구치용도재관(Full-porcelain-occlusal-surfaced PFG, Half-porcelain-occlusal-surfaced PFG, Empress 2, Ice Zirkon)과 선별된 한국음식의 fracture load와 dynamic cyclic load를 측정하여 구치용 도재관에 파절을 일으킬 가능성이 있는 한국음식을 선별하는데 있다. 연구재료 및 방법: 4종의 각 porcelain 보철물 system 당 15개의 축대칭을 이루는 crown을 제작했다. 이때 occlusal reduction은 1.5-2.0 mm로 했다(중심부 1.5 mm, 교두부 2.0 mm). 각 15개의 시편의 교합면 중앙부에 직경 5 mm의 stainless steel ball을 위치시킨 후 Instron 4465 universal testing machine(Instron, Norwood, MA USA)을 이용하여 5 mm/min의 crosshead speed로 수직 부하를 주어 파절을 일으키는 최대 부하(N)를 기록했다. 이후, 한국음식 중 삶은 게, 닭(뼈포함), 소갈비(뼈포함), 마른 오징어, 건멸치, 사탕, 호두껍질을 표본으로 설정하고 이들을 파절시키는 최대 부하(N)를 universal testing machine(Instron 4465) 에서 측정하여 기록했다. 각 항목당 15번을 측정했다. 음식물을 파절시킬 때 필요한 최대부하와 각 보철물의 파절저항을 비교하여 한국의 식습관과 도재를 이용한 보철물 파절의 상관관계를 조사하였다. fracture loads는 analysis of variance 와 Post Hoc tests를 이용해서 분석하였다($\alpha$=0.05). 차후에 위에서 얻은 결과를 바탕으로 Hydraulic Dynamic Fatigue Testing Machine(858 Bionix II, MTS systems, Eden Prairie, MN USA)를 이용하여 4종의 각 porcelain 보철물 system당 5개의 crown에 14Hz Cyclic Load를 가하여 crown에 파절을 일으키는 masticatory cycle수를 알아 보았다. Load 수치는 41.0 N(건멸치 파절강도), 169.0 N(마른오징어 파절강도), 382.9 N(닭뼈 파절강도), 2224.8 N(사탕 파절강도)로 설정하였다. 결과: 95% confidence intervals for mean fracture load는 2599.3-2809.1 N(완전도재교합면 PFG), 3689.4-3819.9 N(반도재교합면 PFG), 1501.2-1867.9 N(Ice Zirkon), 803.2-1188.5 N(Empress 2)로 나왔고 95% confidence intervals for dynamic cyclic load on fracture는 instron 상에서 도재보철물에 파절을 일으키지 않은 load인 2224.8 N(사탕 파절강도)와 382.9 N(닭뼈 파절강도)로 실험했을 때, 2224.8 N에서 4796.8-9321.2 cycles(완전도재교합면 PFG), 2224.8 N에서 881705.1-1143565.7 cycles(반도재교합면 PFG), 382.9 N에서 979993.0-1145773.4 cycles(Ice Zirkon), 382.9 N에서 564.1-954.7 cycles(Empress 2)로 나왔다. 결론: 통계학적으로 유의할 만한 차이가 그룹들 간 fracture load에서 나타났다. 한국음식물 중 소갈비(뼈포함)와 사탕(자두맛캔디)은 구치용 도재보철물을 파절시킬 가능성이 있는 음식물로 밝혀졌다. 단일수직부하에서는 파절이 생기지 않는 경우라 할지라도 dynamic cyclic load를 줄 경우 일정 주기 후에 파절이 생기는 결과를 얻을 수 있었다.

All-ceramic Crown 용 도재의 동적 피로특성 평가 (AN EVALUATION OF DYNAMIC FATIGUE CHARACTERISTICS OF DENTAL CERAMICS FOR ALL-CERAMIC CROWN)

  • 유형우;배태성;송광엽;박찬운
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.781-792
    • /
    • 1997
  • This study was peformed to evaluate the dynamic fatigue characteristics of the dental ceramics for all-ceramic crown. A feldspathic porcelain of VMK68. glass ceramic of IPS-Empress, and glass infiltrated alumina ceramic of In-Ceram were used. Disc specimens were prepared to the final dimensions of 12 mm in diameter and 1 mm in thickness. The biaxial flexure test was conducted using a ball-on-three-ball method. 240 specimens were tested in $37^{\circ}C$ water by testing 20 samples at each of four loading rates:0.05, 0.2, 1, and 5mm/min. 60 specimens were tested in a moisture-free environment by testing 20 samples at 5mm/min. The inert strength of VMK68 was 80.25MPa, and the fatigue parameters were n=29.1, ${\sigma}_{fo}=52.90MPa$. The inert strength of IPS-Empress was 104.76MPa, and the fatigue parameters were n=32.46, ${\sigma}_{fo}=67.52MPa$. The inert strength of In-Ceram was 429.33MPa, and the fatigue parameters were n=31.46, ${\sigma}_{fo}=258.36MPa$. 10-year failure stresses of VMK68, IPS-Empress, and In-Ceram were 20.3MPa, 24.8MPa, and 93.6MPa, respectively. Failure strength and fatigue life showed the highest value in In-Ceram, and then, IPS-Empress and VMK68.

  • PDF

Ceromer crown의 교합면 두께에 따른 압축 파절 강도의 비교 (The compressive fracture strength of ceromer crown by the difference of occlusal thickness)

  • 김지연;박하옥;양홍서
    • 구강회복응용과학지
    • /
    • 제18권3호
    • /
    • pp.205-215
    • /
    • 2002
  • This study investigated the compressive fracture strength of Targis ceromer crown by the difference of occlusal thickness on a maxillary first premolar. Control group was a castable IPS-Empress all-ceramic crown with occlusal thickness of 1.5 mm constructed by layered technique. Experimental groups were Targis crowns having different occlusal thicknesses of 1.0 mm, 1.5 mm, 2.0 mm, 2.5 mm, respectively. The classification of Targis group is T10, T15, T20, T25 and T15N (for no-thermocycling and occlusal thickness of 1.5mm). Ten samples were tested per each group. Except occlusal thickness, all dimension of metal die is same with axial inclination of $10^{\circ}$and marginal width 0.8mm chamfer. All crowns were cemented with Panavia F and thermocycled 1,000 times between $5^{\circ}$ and $55^{\circ}$ water bath with 10 sec dwelling time and 10 sec resting time. The compressive fracture strength was measured by universal testing machine. The results were as follows : 1. Fracture strength was increased as the occlusal thickness increased : compressive fracture strength of Group T10, T15, T20, T25 was $66.65{\pm}4.88kgf$, $75.04{\pm}3.01kgf$, $87.07{\pm}7.06kgf$ and $105.03{\pm}10.56kgf$, respectively. 2. When comparing material, Targis crown had higher fracture strength than IPS-Empress crown : the mean compressive strength of group T15 was $75.04{\pm}3.01kgf$ and the value of group Control was $37.66{\pm}4.28kgf$. 3. Fracture strength was decreased by thermocycling : the compressive fracture strength of T15 was $75.04{\pm}3.01kgf$, which is lower than $90.69{\pm}6.88kgf$ of group T15N. 4. The fracture line of crowns began at the loading point and extended along long axis of tooth. IPS-Empress showed adhesive failure pattern whereas Targis had adhesive and cohesive failure. In the SEM view, stress was distributed radially from loading point and the crack line was more prominent on Targis crown.