• Title/Summary/Keyword: Empirical power

Search Result 955, Processing Time 0.028 seconds

Empirical Comparisons of Disparity Measures for Partial Association Models in Three Dimensional Contingency Tables

  • Jeong, D.B.;Hong, C.S.;Yoon, S.H.
    • Communications for Statistical Applications and Methods
    • /
    • v.10 no.1
    • /
    • pp.135-144
    • /
    • 2003
  • This work is concerned with comparison of the recently developed disparity measures for the partial association model in three dimensional categorical data. Data are generated by using simulation on each term in the log-linear model equation based on the partial association model, which is a proposed method in this paper. This alternative Monte Carlo methods are explored to study the behavior of disparity measures such as the power divergence statistic I(λ), the Pearson chi-square statistic X$^2$, the likelihood ratio statistic G$^2$, the blended weight chi-square statistic BWCS(λ), the blended weight Hellinger distance statistic BWHD(λ), and the negative exponential disparity statistic NED(λ) for moderate sample sizes. We find that the power divergence statistic I(2/3) and the blended weight Hellinger distance family BWHD(1/9) are the best tests with respect to size and power.

An Experimental Investigation of the Interfacial Condensation Heat Transfer in Steam/water Countercurrent Stratified Flow in a Horizontal Pipe

  • Chu, In-Cheol;Yu, Seon-Oh;Chun, Moon-Hyun;Kim, Byong-Sup;Kim, Yang-Seok;Kim, In-Hwan;Lee, Sang-Won
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.565-570
    • /
    • 1998
  • An interfacial condensation heat transfer phenomenon in a steam/water countercurrent stratified flow in a nearly horizontal pipe has been experimentally investigated. The present study has been focused on the measurement of the temperature and velocity distributions within the water layer. In particular, the water layer thickness used in the present work is large enough so that the turbulent mixing is limited and the thermal stratification is established. As a result, the thermal resistance of the water layer to the condensation heat transfer is increased significantly. An empirical correlation of the interfacial condensation heat transfer has been developed. The present correlation agrees with the data within $\pm$15%

  • PDF

Performance Analysis of 30 kVA Super-Conducting Generator under Light Load (30 kVA 초전도 발전기의 소용량 부하 인가시 운전특성 해석)

  • Ha, Kyoung-Duck;Hwang, Don-Ha;Park, Doh-Young;Kim, Yong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.271-273
    • /
    • 1999
  • In this paper 30 kVA Super-Conducting Generator's test and analysis results of OCC and SCC are presented. Also the test and FE analysis results of the generator under 1.2, 2.4, and 3.6[kW] load are described. For FE analysis of the generator's performance, the external circuit is coupled with the FE region. The generator's end winding reactance is obtained based on the design data, actual dimension, preliminary FE analysis, and empirical formulas. The comparison of FE analysis coupled with external circuit to the test results shows a good agreement.

  • PDF

Analysis and Calibration of Propeller Power Effect for Turboprop Aircraft (터보프롭 항공기의 프로펠러 파워효과 해석 및 보정)

  • Park, Youngmin;Chung, Jindeog
    • Journal of Aerospace System Engineering
    • /
    • v.9 no.4
    • /
    • pp.62-66
    • /
    • 2015
  • During the conceptual design of turboprop aircraft, the power effect driven from rotating propeller is typically obtained from empirical data. In the present paper, propeller power effect was obtained by using unsteady three-dimensional Navier-Stokes solver with $k-{\omega}$ turbulence model for the accurate prediction of turboprop aircraft performance. In order to simulate the relative motion between propeller and fuselage, unsteady sliding mesh method was used. During simulation, three flow conditions such as climb, cruise and descending flight were selected considering the flight envelop of the real turboprop aircraft. For the correction of aerodynamic coefficients, the thrust effect of engine exhaust gas was included based on the engine manufacturer's data. Using the computational results, the correction table for the aerodynamic coefficient of turboprop aircraft was suggested for the performance analysis of turboprop aircraft.

Indoor Positioning Using WLAN Signal Strength (무선랜의 신호세기를 이용한 실내 측위)

  • Kim, Suk-Ja;Lee, Jin-Hyun;Jee, Gyu-In;Lee, Jang-Gyu;Kim, Wuk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.8
    • /
    • pp.742-747
    • /
    • 2004
  • Outdoors we can easily acquire our accurate location by GPS. However, the GPS signal can't be acquired indoors because of its weak signal power level. Adequate positioning method is demanded for many indoor positioning applications. At present, wireless local area network (WLAN) is widely installed in various areas such as airport, campus, and park. This paper proposes a positioning algorithm using WLAN signal strength to provide the position of the WLAN user indoors. There are two methods for WLAN based positioning, the signal propagation method uses signal strength model over space and the empirical method uses RF power propagation database. The proposed method uses the probability distribution of the power propagation and the maximum likelihood estimation (MLE) algorithm based on power strength DB. Test results show that the proposed method can provide reasonably accurate position information.

An Empirical Study on the Change in Market Power after Mergers & Acquisition (합병과 시장지배력의 관계분석)

  • Chung Bhum-Suk;Lee Jin
    • Management & Information Systems Review
    • /
    • v.4
    • /
    • pp.327-348
    • /
    • 2000
  • There are three major motives for M&A, financial synergy effect, operating & managerial synergy effect, and tax effect. The purpose of this study is to prove the operating & managerial synergy effect of M&A. To do this, we analyze the market-ripple effect of M&A, focusing on the increase in market power. Specifically we use cross-sectional data from 1985 to 1998 to show whether a market power of mergers is higher than that of a matched non-merging control group. we use time series data to show whether a market power of merger is higher than that of pre-merger. Also we use the event study using market model to show the stock price movement after mergers. The result is that although revenue increase after mergers, profit of the firms does not improve after mergers. Also there is sufficient evidence to say that there is a cumulative abnormal return for the firms after mergers.

  • PDF

The Demonstration Research on Hybrid Power Generation System Based on Wind Power (풍력기반의 하이브리드 발전시스템의 실증연구)

  • Ahn, Jae-Young;Lee, Hwa-Choon;Song, Sung-Geun;Lee, Sang-Hun;Cho, Su-Eog;Park, Sung-Joon;Kim, Gwang-Heon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.106-113
    • /
    • 2010
  • In this paper, the empirical study for a hybrid generation system based on wind power which is leading renewable energy was performed. The simulation for the overall operation of the wind generator, diesel generators, monitoring system and a central controller operated in Demonstration Complex was carried out. In addition, the adequacy of the control algorithm was examined through the experiments.

A Study on the Optimal Design Fuzzy Type Stabilizing Controller Using Genetic Algorithm (유전 알고리즘을 이용한 퍼지형 안정화 제어기의 최적설계에 관한 연구)

  • Lee, Heung-Jae;Lim, Chan-Ho;Yoon, Byong-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.326-328
    • /
    • 1998
  • This paper presents an optimal fuzzy power system stabilizer to damp out low frequency oscillation. The fuzzy logic controllers has been applied to a power system stabilizing controllers. But the design of a fuzzy logic power system stabilizer relies on empirical and heuristic knowledge of human experts as well as many trial-and-errors in general. This paper presents the optimal design method of the fuzzy logic stabilizer using the genetic algorithm, which is the optimization method based on the mechanics of natural selection and natural genetics. The proposed method tunes the parameters of the fuzzy logic stabilizer in order to minimize the consuming time during the design process. In this paper, the proposed method tunes the shape of membership function of the fuzzy variables. The proposed system is applied to the one-machine infinite-bus model of a power system. Through the case study, the efficiency of the fuzzy stabilizing controller tuned by genetic algorithm is verified.

  • PDF

A Study on the Cost Estimate System Development Method for Nuclear Power Plant Construction Projects

  • Lee, Sang Hyun
    • International conference on construction engineering and project management
    • /
    • 2017.10a
    • /
    • pp.133-137
    • /
    • 2017
  • Nuclear power plants in Korea are usually built based on a duplicated model; so the project cost data of the preceding unit can be used as reference when estimating the project cost for the succeeding unit. However, since the contracting method is oriented towards the price, empirical factors such as making top-down estimations using the reverse calculation method based on the completion cost of the preceding unit is dominant. In order to develop a project cost database to resolve such problems, the detailed cost boundary of the project cost data must be categorized by project and by system. This study proposes a method to connect the code of account with the base quantities and the IAEA account, and proposes a database structure for the development of a project cost estimation system. The estimation system developed in the future is expected to utilize the proposed project cost data structure.

  • PDF

Anomaly Detection System for Solar Power Distribution Panels utilizing Thermal Images

  • Kwang-Seong Shin;Jong-Chan Kim;Seong-Yoon Shin
    • Journal of information and communication convergence engineering
    • /
    • v.22 no.2
    • /
    • pp.159-164
    • /
    • 2024
  • This study aimed to develop an advanced anomaly-detection system tailored for solar power distribution panels using thermal imaging cameras to ensure operational stability. It addresses the imperative shift toward digitalized safety management in electrical facilities, transcending the limitations of conventional empirical methodologies. Our proposed system leverages a faster R-CNN-based artificial intelligence model optimized through meticulous hyperparameter tuning to efficiently detect anomalies in distribution panels. Through comprehensive experimentation, we validated the efficacy of the system in accurately identifying anomalies, thereby propelling safety protocols forward during the fourth industrial revolution. This study signifies a significant stride toward fortifying the integrity and resilience of solar power distribution systems, which is pivotal for adapting to emerging technological paradigms and evolving safety standards in the energy sector. These findings offer valuable insights for enhancing the reliability and efficiency of safety management practices and fostering a safer and more sustainable energy landscape.