A Study on the Evaluation of Water Consumption in Electric Appliances using Water Footprint - Focusing on Washing Machine - (Water Footprint 개념을 이용한 가전제품의 수자원 사용량 산정 (세탁기를 중심으로))

  • Jo, Hyun-Jung;Kim, Woo-Ram;Park, Ji-Hyoung;Hwang, Young-Woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.691-697
    • /
    • 2011
  • In this study, by using the Water footprint technique, the water consumption by washing machines, which holds higher ranks in using water than any other electric appliances, was analyzed during their life cycle. The life cycle is defined as raw materials production step, manufacturing step, and using step. In raw materials production step, Input materials were researched by using LCI DB(Life Cycle Inventory Database) and the water consumption was calculated with consideration of approximately 65% Input materials which were based weight. In manufacturing step, the water consumption was calculated by the amount of energy used in assembly factories and components subcontractors and emission factor of energy. In using step, referring to guidelines on carbon footprint labeling, the life cycle is applied as 5 years for a washing machine and 218 cycles for annual bounds of usage. The water and power consumption for operating was calculated by referring to posted materials on the manufacture's websites. The water consumption by nation unit was calculated with the result of water consumption by a unit of washing machine. As a result, it shows that water consumption per life cycle s 110,105 kg/unit. The water consumption of each step is 90,495 kg/unit for using, 18,603 kg for raw materials production and 1,006 kg/unit for manufacturing, which apparently shows that the using step consume the most water resource. The water consumption by nation unit is 371,269,584tons in total based on 2006, 83,385,649 tons in both steps of raw material production and manufacturing, and 287,883,935 tons in using step.

Exergetic and Thermoeconomic Analysis of a 200kW Phosphoric Acid Fuel Cell Plant (200kW 인산형 연료전지 발전시스템의 엑서지-열경제학적 해석)

  • Jeon, J.;Kwak, H.;Lee, H.;Choi, D.;Park, D.;Cho, Y.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.689-696
    • /
    • 2001
  • Exergetic and thermoeconomic analysis were performed for a 200kW Phosphoric Acid Fuel Cell(PAFC) plant which offers many advantage for cogeneration in the aspect of high electrical efficiency and low emission. This analytical study was based on the data obtained by in-field measurement of PC25 fuel cell plant to find whether this system is viable economically. For 100% load condition, the electrical efficiency and the unit cost of electricity are about 45% and 0.032 $/kWh respectively, which turn out to be much better than those for the 1000kW gas turbine cogeneration plant. Further, at lower loads, the unit costs of electricity and hot water increase slightly and consequently more economic operation is possible at any loads.

  • PDF

An Experimental Study of Short Stack on the Performance of the Proton Exchange Membrane Fuel Cell for the Residential Power generation (소형 모듈 스택을 이용한 가정용 연료전지 성능의 실험적 고찰)

  • Choi, Won-Seok;Kim, Yong-Mo;Yu, Sang-Seok;Lee, Young-Duk;Hong, Dong-Jin;Ahn, Kook-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.21-24
    • /
    • 2008
  • Proton Exchange Membrane Fuel Cell (PEMFC) is an attractive candidate for residential power generator due to fast start-up and stop, high efficiency, low emission, and high power density. In this study, we employ short module stack to understand the performance of the unit cell of the stack in terms of operating temperatures. To simulate the practical fuel cell stack of residential power generator, the structure and active area of the short module stack is kept the same as that of the practical fuel cell. The results shows that the electric potential of short module stack is different from the number of cells times the potential of unit cell because of cell-to-cell variation.

  • PDF

The influence of exhaust system on heat efficiency and fuel consumption of S.I engine (엔진운전조건에 따른 배기시스템의 압력분포특성에 관한 연구)

  • 김동현;박세종;손성만;박경석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1091-1096
    • /
    • 2004
  • It is necessary to consider the stability, economic environmental-friendly problems by the development of the road, supply of the automobile, environmental problem as designing the exhaust system. To reduce the noise and the vibration of the automobile. The need for stricter regulation limits emission and demand for lower fuel comsumption. According to motor vehicle company develop variable type muffler, dual muffler and active intelligence exhaust system unit. Improvement in engine performance and fuel consumption for demand information of pressure fraction and heat characteristics. To be able to determine these factor for we experiment on each case of exhaust system unit. In this study, in order to establish the optimized conditions design factors which are taking many performance as the variable valve, it shows how the standard performance and the additional element of the exhaust system effects on the engine performance.

  • PDF

Comparison on Social Cost by Unit Calorific Value between Wood Pellets and Coals (목재펠릿과 석탄의 단위 발열량에 따른 사회적 비용 비교 분석)

  • Li, Lingying;Kim, Joon Soon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.4
    • /
    • pp.403-410
    • /
    • 2017
  • With the growing importance of GHG reduction, wood pellets are considered as a cheaper renewable energy and carbon neutral. On the other hand, there is a concern that the burning wood pellets may release even more air pollutants such as CO and VOCs. In this study, we analyzed the social costs of burning fuels including wood pellets and coals based on the unit calorific value. The social costs were calculated by sum of the import costs of the fuels and the emission costs of the air pollutants. The results showed that wood pellets are inferior to coals in the aspect of the social costs. It is necessary to improve the quality of the wood pellets and pellet boiler facilities for being used eco-friendly energy sources in the future. We suggest that the control facilities of CO and VOCs should be installed, if the control costs are lower than the pollution costs.

Measurement of odor compounds from odorous emissions source of Industrial Complex (산업단지에서 배출되는 악취원인물질의 규명)

  • An Sang-Young;Choi Sung-Woo
    • Journal of Environmental Science International
    • /
    • v.14 no.1
    • /
    • pp.81-89
    • /
    • 2005
  • As a typical example of simultaneous analysis of the odorous compounds, the volatile organic compounds from inventory sources in Seongseo industrial area were concentrated and analyzed with thermal desorber/GC/MSD, and major malodorous compounds were estimated. Odor intensity and odor concentration was analyzed simultaneously During a period from November in 2002 to December in 2003, this study was conducted to evaluate malodor emission characterization in major treatment facilities. The major components were Dimethyl sulfide, Dimethyl disulfide, Methyl mercaptane, Ammonia, Benzene, Toluene, m,p-xylene, o-xylene, Styrene, 1,2,4­T.M.B and 1,3,5-T.M.B. Among the six major inventory sources, the odor unit concentration of Night-soil disposal facilities was the highest, $669\~2344\;ou/m^{3}.$

Fabrication and Properties of Under Gate Field Emitter Array for Back Light Unit in LCD

  • Jung, Yong-Jun;Park, Jae-Hong;Jeong, Jin-Soo;Nam, Joong-Woo;Berdinsky, Alexander S.;Yoo, Ji-Beom;Park, Chong-Yun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1530-1533
    • /
    • 2005
  • We investigated under-gate type carbon nanotube field emitter arrays (FEAs) for back light unit (BLU) in liquid crystal display (LCD). Gate oxide was formed by wet etching of ITO coated glass substrate instead of depositing $SiO_2$ on the glass substrate. Wet etching is easer and simpler than depositing and etching of thick gate oxide to isolate the gate metal from cathode electrode in triode. Field emission characteristic s of triode structure were measured. The maximum current density of 92.5 ${\mu}A/cm^2$ was when the gate and anode voltage was 95 and 2500 V, respectively at the anode-cathode spacing of 1500 ${\mu}m$.

  • PDF

Next Generation PET for Human Brain Study

  • Murayama, Hideo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.35-37
    • /
    • 2002
  • Conceptual design of the next generation PET with both high sensitivity and high spatial resolution has been performed. A detector unit using a depth encoding scheme was designed and constructed for trial. The unit consists of four Gd$_2$SiO$\sub$5/:Ce crystal blocks in a 2x2x4 array coupled to a position-sensitive photomultiplier tube having metal channel dynodes and 4x4 multi-anodes. Our proposed detector is a very reliable and simple solution suitable for volume PET devices since the proposed depth encoding scheme does not need additional photo-detectors.

  • PDF

Fluorometric Determination of Gastric Acidity with 2-Fluorenecarboxaldehyde Hydrazone

  • Choi, Kyong;Choi, Jung-Kap;Yoo, Gyurng-Soo
    • Archives of Pharmacal Research
    • /
    • v.17 no.4
    • /
    • pp.231-235
    • /
    • 1994
  • Fluorenecarboxaldehyde hydrazone 9FCH)was synthesized as a new fluorescent reagent for the determination of acidity. FCH had no fluorescence in itself, however, it strongly fluoresced under acidic conditions at excitation maximum of 392 nm and emission maximum of 447 nm, respectively. It showed good correlation with pH in the range from pH 0.60 to pH 3.60 in strong acids. As an application, the acidity of gastric juice in rats and humans was determined. In comparision with pH-metry, the acidity measured by the developed method showed generally increased values of about 0.7-1.3 unit and 0.8-1.2 unit in rats and humans, respectively. However, these results had statistically close correlation with those of pH-metry and the correlation coefficients were 0.887 in rats and humans between two methods.

  • PDF

Development of a Very Small LED Lamp with a Low-Thermal-Resistance Lead Frame for an LCD Backlight Unit

  • Yu, Soon-Jae;Kim, Do-Hyung;Choi, Yong-Seok;Kim, Hee-Tae
    • Journal of Information Display
    • /
    • v.10 no.2
    • /
    • pp.49-53
    • /
    • 2009
  • In this study, a very small LED packaging lead frame with a low thermal resistance was developed. The cost of the package process was reduced by the use of many small LED lamps, which increased the light emission efficiency. Compared to the large lead frame lamp, however, the optical property of the small LED packaging lead frame lamp was not sufficiently improved because its reflection structure was changed and its reflection area was reduced. The luminous efficiency of the LED lamp reaches 58 lm/W at the current density of 0.16 A/$cm^2$. Using the LED lamps, 46-inch LCD BLU was manufactured. The BLU-made LED lamps have a low power consumption of 146 W and have a slim (10-mm-thick) BLU, keeping good uniformity in terms of brightness, and maintaining good thermal properties.