• Title/Summary/Keyword: Emission spectrometry

Search Result 255, Processing Time 0.023 seconds

Direct Analysis of Aerosol Particles by Atomic Emission and Mass Spectrometry

  • Kawaguchi, Hiroshi;Nomizu, Tsutomu;Tanaka, Tomokazu;Kaneco, Satoshi
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.411-418
    • /
    • 1995
  • A method for the direct determination of elemental content in each of aerosol particles by inductively coupled plasma atomic emission (ICP-AES) or mass spectrometry (ICP-MS) is described. This method is based upon the introduction of diluted aerosol into an ICP and the measurement of either the flash emission intensities of an atomic spectral line or ion intensities. A pulse-height analyzer is used for the measurement of the distribution of the elemental content. In order to calibrate the measuring system, monodisperse aerosols are used. The potentials of the method are shown by demonstrating the copper emission signals from the aerosols generated at a small electric switch, a study of the relation between the decreasing rate of particle number density and particle size, and measurements of calcium contents in the individual biological cells.

  • PDF

Analysis of $Si_3N_4$ Ultra Fine Powder Using High-pressure Acid Digestion and Slurry Injection in Inductively Coupled Plasma Atomic Emission Spectrometry

  • Kim, K.H.;Kim, H.Y.;Im, H.B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.2
    • /
    • pp.159-163
    • /
    • 2001
  • Si3N4 powder has been analyzed by inductively coupled plasma atomic emission spectrometry (ICP-AES). The sample was dissolved by high-pressure acid digestion with HF, H2SO4 (1+1), and HNO3 mix ture. This technique is well suited for the impurity analysis of Si3N4 because the matrix interference is eliminated. A round-robin samples trace elements, such as Ca, W, Co, Al, Fe, Mg, and Na, were determined. For the direct analysis, slurry nebulization of 0.96 mm Si3N4 powder also has been studied by ICP-AES. Emission intensities of Fe were measured as ICP operational conditions were changed. Significant signal difference between slurry particles and aqueous solution was observed in the present experiment. Analytical results of slurry injection and high-pressure acid digestion were compared. For the use of aqueous standard solution for calibration, k-factor was determined to be 1.71 for further application.

Analysis of Cast Iron by Glow Discharge Emission Spectrometry (글로우 방전/방출분광분석법에 의한 주철시료의 분석)

  • Cho, K.H.;Woo, J.C.;Han, M.S.
    • Analytical Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.297-305
    • /
    • 1993
  • Generally, it is difficult to analyze cast iron samples with spark discharge emission spectrometry since the content of carbon in these samples is high as a few percent. The cast iron samples were analyzed with the developed glow discharge emission spectrometer composed of glow discharge emission source and polychromator. The discharge condition of glow discharge lamp(GDL) has been optimized by variation of Ar gas pressure, discharge voltage and discharge time. Under the optimum conditions obtained in this work, relationships between the measured emission intensities and concentration of two types of cast iron standard samples(BAS, LECO) were investigated. Most of elements(Mn, Si, P, S etc.) showed the good linearity in one calibration curve. And the carbon showed slightly the systematic difference according to the type of standard samples.

  • PDF

A Study on Air Emission Spectra Observed by Using Electrothermal-Hollow Cathode Glow Discharge Spectrometry (Et-HCGDS) (Electrothermal-Hollow Cathode Glow Discharge Spectrometry(Et-HCGDS)를 이용하여 살펴본 Air Emission에 관한 연구)

  • Lee, Sang Chun;Shin, Jung-Sook;Kang, Mi-Ra
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.5
    • /
    • pp.399-407
    • /
    • 1995
  • Electrothermal-Hollow Cathode Glow Discharge Spectrometry (Et-HCGDS) has been constructed in our laboratory for in-situ monitoring of traceble amounts of rare earth elements and actinides. Et-HCGDS is the portable glow discharge system that can perform the trace analysis of elements. The main structural design of Et-HCGDS was based upon the electrothermal heating and glow discharge techniques. More details on Et-HCGDS are available elsewhere. In this study, air was used as a flow gas for the glow discharge system. As a result, the emission spectra of air were collected and the assignment of air emission lines was performed with helps of pure nitrogen and oxygen emission spectra and previously published results. We found that the emission lines of air plasma were mainly due to nitrogen molecules. This paper includes the complete assignments of the air emission lines observed by using Et-HCGDS. Also, this study will be an useful reference for spectrochemical anaysis including air analysis.

  • PDF

Preconcentration of Cd by Continuous Hydroxide Precipitation-Dissolution in Atomic Emission Spectrometry

  • 연평흠;허걸;박용남
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.7
    • /
    • pp.766-770
    • /
    • 1998
  • On-line preconcentration by direct precipitation with hydroxide has been developed and applied for the analysis of Cd in Inductively Coupled Plasma Atomic Emission Spectrometry. Cadmium is continuously precipitated with hydroxide and dissolved by nitric acid in on-line mode. Currently, the enrichment factor is more than 90 times for 20.0 mL of sample and could be further increased very easily. For a large sample throughput, 1.0 mL of sample loop is used and the enrichment factor is 4.5 with the sampling speed of 15/hr. The method has been applied to the analysis of NIST reference sample and has yielded good results with the certified value.

Thermo-Field emission in silicon nanomembrane ion detector for mass spectrometry (실리콘 나노 박막의 열-전계 방출효과를 이용한 분자 질량분석)

  • Park, Jong-Hoo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.586-591
    • /
    • 2013
  • This paper describes the characteristics of thermo-field emission in a freestanding silicon nanomembrane under ion bombardment with various thermal and field conditions. The thermal effect and field effect in thermo-field emission in silicon nanomembrane are investigated by varying kinetic energy of ions and electric field applied to the silicon nanomembrane surface, respectively. We found that thermo-field emission increases linearly as the electric field increases, when the electric field intensity is lower than the threshold. The thermo-field emission (schottky effect) increases proportionally to the power of temperature, which agree well with the predictions of a thermo-field emission model.

Comparison of analytical methods for quantifying total chromium in soil using Atomic Absorption Spectrometer (AAS) and Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) (토양 시료 중 Atomic Absorption Spectrometry (AAS) 및 Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES)를 이용한 총 크롬 분석방법 비교)

  • Lee, Hong-gil;Kim, Ji-in;Byun, Yoonjoo;Kim, Hyunkoo;Yoon, Jeong Ki
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.6
    • /
    • pp.22-28
    • /
    • 2017
  • The accuracy of analytical results in response to the use of different additives ($NH_4Cl$, KCl, $LaCl_3$) and oxidant gases was evaluated and compared by using Atomic Absorption Spectrometry (AAS). Identification of spectroscopic interferences and possible improvements in Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) analysis were also discussed. The average accuracies of total chromium using Certified Reference Materials (CRMs) were found to be 72.1~94.2% in air/acetylene flame condition by AAS, and they were improved to 100.5~110.5% when the oxidants was changed to nitrous oxide rather than adding the additives. The field samples showed similar trends to CRMs, but chromium concentrations were highly variable depending on analytical conditions. The average accuracies using CRMs were estimated to be 89.3~166.1% by ICP-AES, and improved to below 121.7% after eliminating iron interference. Field samples with low chromium and high iron concentration were measured to be > 30% lower in total chromium concentrations by ICP-AES than AAS in nitrous oxide/acetylene flame. Total chromium concentrations in soil could be analyzed with better accuracy under nitrous oxide/acetylene flame by AAS because it was more effective to increase the temperature of the flame than to eliminate the chemical interference for maximizing atomization of chromium. When using ICP-AES, interference substances, total chromium levels, and analytical conditions should be also considered.

An Investigation on the Extraction and Quantitation of a Hexavalent Chromium in Acrylonitrile Butadiene Styrene Copolymer (ABS) and Printed Circuit Board (PCB) by Ion Chromatography Coupled with Inductively Coupled Plasma Atomic Emission Spectrometry

  • Nam, Sang-Ho;Kim, Yu-Na
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.6
    • /
    • pp.1967-1971
    • /
    • 2012
  • A hexavalent chromium (Cr (VI)) is one of the hazardous substances regulated by the RoHS. The determination of Cr (VI) in various polymers and printed circuit board (PCB) has been very important. In this study, the three different analytical methods were investigated for the determination of a hexavalent chromium in Acrylonitrile Butadiene Styrene copolymer (ABS) and PCB. The results by three analytical methods were obtained and compared. An analytical method by UV-Visible spectrometer has been generally used for the determination of Cr (VI) in a sample, but a hexavalent chromium should complex with diphenylcarbazide for the detection in the method. The complexation did make an adverse effect on the quantitative analysis of Cr (VI) in ABS. The analytical method using diphenylcarbazide was also not applicable to printed circuit board (PCB) because PCB contained lots of irons. The irons interfered with the analysis of hexavalent chromium because those also could complex with diphenylcarbazide. In this study, hexavalent chromiums in PCB have been separated by ion chromatography (IC), then directly and selectively detected by inductively coupled plasma atomic emission spectrometry (ICP-AES). The quantity of Cr (VI) in PCB was 0.1 mg/kg.