• Title/Summary/Keyword: Emission pollutants

Search Result 627, Processing Time 0.032 seconds

An Analysis of First Flush Phenomenon of Non-point Source Pollution during Rainfall-Runoff Events from Impervious Area (불투수성 지역의 강우유출수에 대한 비점오염물질의 초기유출현상 분석)

  • Ahn, Tae-Ung;Bum, Bong-Su;Kim, Tae-Hoon;Choi, I-Song;Oh, Jong-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.9
    • /
    • pp.643-653
    • /
    • 2013
  • In this study, trend analysis was performed by various runoff analysis method of Non-point Pollution Source(NPS) at the impervious area. The characteristics of rainfall at impervious area appeared to be influenced by rainfall strength and it appeared that first flush phenomenon occurs often if rainfall strength acts largely. It is judged that the measure is required to be prepared against that now that concentration difference of non-point pollution source appeared to be big by precedent number of days of no rainfall. As the result of calculating Decrease Rate (DR) by first flush of non-point pollution source, it is judged that it is important to prepare the measure against the pollutants about initial rain and it is necessary to calculate the capacity of non-point pollution source processing facilities regarding that now that the non-point pollution source integrated at impervious area showed the characteristics that are flowed out in high concentration by initial rain in case of non-rainfall considering the characteristics of non-point pollution source at impervious area. When taking 50% of non-point pollution source as the standard for decrease rate that was evaluated previously, it appeared as 15~60 min in case of TSS and it appeared as 30~90 min in case of organic compound, but the characteristic whose decrease rate is below 50% also appeared even till rainfall-runoff ends. Based on that, it is judged that it could be used as the reference when designing the structural BMPs facilities later.

Research Study on Indoor Air Quality (IAQ) inside of the Subway Cabin in Seoul Metropolitan City (지하철 전동차 객실 내부 공기질 조사 연구)

  • Lee, Kyoung Bin;Kim, Jin Sik;Bae, Sung Joon;Kim, Shin Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.2
    • /
    • pp.175-187
    • /
    • 2014
  • The subways play an important part in serious traffic problems. Almost seven million citizens a day are using subways as a means of traffic communication in the Seoul metropolitan city in 2012. However, the subway system is a semi-closed environment, so many serious problems occurred in subway stations and injured passengers' health. Platform screen doors (PSD) are expected to prevent negligent accident such as injury or death from falling and improve the air quality of the subway station. Installation of PSD at stations in Seoul metropolitan subway had been completed in December 2009. Consequently, the underground transportation system became a closed environment, so the air quality has improved the platforms, but it has deteriorated in the tunnels. Especially, the subway cabin has many doors, and the doors are frequently opened and closed. For this reason, the effect of door opening on subway cabin, dust flow inside the subway cabin. In this process, the maintenance work may influence the health of people who work underground, as well as that of subway users (passengers). In this study, we measured air quality inside and outside of the subway cabin line 2 in Seoul, Korea. This study focused on the investigation of Indoor Air Quality (IAQ) and measurement target pollutants are PM10, CO, $CO_2$, $NO_2$, $O_3$. It was found that levels of PM10, $CO_2$, and $NO_2$ inside subway cabin line 2 exceeded the Korea IAQ standard. Concentrations of PM10, $CO_2$, and $NO_2$ inside of the cabin are higher than outside of the cabin (Indoor Outdoor ratio is higher than 1.). Concentrations of CO, $O_3$ inside of the cabin are lower than outside of the cabin (Indoor Outdoor ratio is lower than 1.). There is a high correlation between $CO_2$ and passengers inside of the cabin and PM10 is only the weakest correlation with passengers. Therefore, it is important to find out the emission source of $NO_2$. The results of this study will be useful as fundamental data to study indoor air quality of a subway cabin.

Assessment of Technology-Based Industrial Wastewater Effluent Limitations and Standards for the Application in Domestic Industries ( I ) : Case-study, Applying TBELs in US (처리기술에 근거한 산업폐수 배출허용기준 국내 적용성 연구( I ) : 미국 TBELs 적용사례 검토)

  • Kim, Kyeongjin;Son, Daehee;Her, Jin;Kim, Kwangin;Kwon, Osang;Yeom, Ictae
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • Technology-Based Effluent Limitations (TBELs) is a permit limits for a pollutant that is based on the capability of a treatment technology to reduce the pollutant to a certain concentration. Widely practiced for regulations of industrial wastewater in US, TBELs has been accepted as an effective means that can achieve balanced goals between complete elimination of pollutants discharge and economic feasibility for industries. The review of TBELs application in US and the applicability of TBELs to the domestic industry categories was given in three papers. In the first paper, the development and practices of TBELs in US were reviewed including case studies. The developments of TBELs in US in the four major categories, the metal products & machinery, the petroleum refining, the porcelain enameling and the meat & poultry products were reviewed. The applicability of TBELs to the domestic industrial categories was also assessed. In the second paper, the pollution loads analysis for domestic industrial wastewater was conducted based on risk assessment indicator using Toxic Weighting Factors (TWFs). This is an essential part to determine the priority of TBELs application for the domestic industrial categories. In the last paper, the application of TBELs to the domestic industries was demonstrated through a case-study for the pulp/paper/paperboard category. Direct application of TBELs of US into the Korean regulation system may not be desirable because the specific goals and the environment for the regulations for the two countries may not be identical. For example, unlike US, Korea does not adopt the individual permit system for pollution sources. However, among the unproductive and exhaustive controversies over the uniform regulations regardless of the industrial categories in Korea, the introduction of the principles of TBELs are inevitable and more extensive study for applications of TBELs optimized for Korean regulation system will be necessary.

Preparation of Natural Wall Paint by Using Sericite Clay (견운모를 이용한 벽마감용 천연페인트 제조)

  • Kim, Munui;Lalhmunsiama, Lalhmunsiama;Lee, Seung-Mok;Jin, Kang-Jung
    • Applied Chemistry for Engineering
    • /
    • v.28 no.5
    • /
    • pp.501-505
    • /
    • 2017
  • Due to the rapid urbanization and increased population, there is an increase in airtight nature of buildings which causes serious indoor air pollution. Among several indoor air pollutants, volatile organic compounds (VOCs) emitted from paint are of major concern. Therefore, there is an urge for the development of environmental friendly paint products. In this wok, a natural wall paint (NWP) was prepared by utilizing a natural clay material "sericite" as a main component. A small chamber test was carried out to identify the toxic substances release from NWP and the results were compared with two eco-friendly commercial paints. The total VOCs were detected in trace level inside the test chamber and their concentrations were below the recommended indoor air quality standards. Toluene was not detected for NWP, whereas formaldehyde was observed in trace level. The toxicity index results were compared with two commercial paints and found that NWP exhibited less harmful gas emission. Based on certification rating of building materials, NWP can be classified as the first grade of building materials. Due to the above advantages, the use of sericite as a major component in NWP will be a useful technique to maintain the indoor air quality.

Development of a Raman Lidar System for Remote Monitoring of Hydrogen Gas (수소 가스 원격 모니터링을 위한 라만 라이다 시스템 개발)

  • Choi, In Young;Baik, Sung Hoon;Park, Nak Gyu;Kang, Hee Young;Kim, Jin Ho;Lee, Na Jong
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.4
    • /
    • pp.166-171
    • /
    • 2017
  • Hydrogen gas is a green energy sources because it features no emission of pollutants during combustion. But hydrogen gas is very dangerous, being flammable and very explosive. Hydrogen gas detection is very important for the safety of a nuclear power plant. Hydrogen gas is generated by oxidation of nuclear fuel cladding during a critical accident, and leads to serious secondary damage in the containment building. This paper discusses the development of a Raman lidar system for remote detection and measurement of hydrogen gas. A small, portable Raman lidar system was designed, and a measurement algorithm was developed to quantitatively measure hydrogen gas concentration. To verify the capability of measuring hydrogen gas with the developed Raman lidar system, experiments were carried out under daytime outdoor conditions by using a gas chamber that can adjust the hydrogen gas density. As results, our Raman lidar system is able to measure a minimum density of 0.67 vol. % hydrogen gas at a distance of 20 m.

Real Time Measurement of Exhaust Emissions from Main Engine using Training Ship (실습선을 이용한 주 추진기관의 배기배출물의 실시간 계측)

  • Choi, Jung-Sik;Lee, Sang-Deuk;Lee, Kyoung-Woo;Chun, Kang-Woo;Nam, Youn-Woo;Yoon, Seok-Hun;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.5
    • /
    • pp.531-537
    • /
    • 2013
  • In this study, we conducted real-time measurement at the ship arrivals and departures at the port and at a constant speed of 150 rpm for exhaust emissions from a main engine installed on the training ship, HANBADA, of Korea Maritime University. The result showed that the concentration of nitrogen oxide was measured in the range of 800 ppm to 1,000 ppm at constant speed mode. On the other hand, the concentration of nitrogen oxide during ship arrivals and departures was significantly fluctuated between 210 ppm and 1,230 ppm. And, the concentration of carbon oxide at the arrivals and departures was also larger than that of at constant speed mode. These results show that the ship maneuvering skills to prevent a sudden load change of main engine at the arrivals and departures of ship is needed. Additionally, it means that the difference of exhaust emissions generated between the constant speed mode and the arrival/departure has to be considered when invented many technologies are adopted into the reduction technologies of air pollutants from ships.

Studies on the Use of Carboxymethylcellulose Sodium Salt Matrix for the Immobilization of Photobacterium phosphoreum (Photobacterium phosphoreum을 고정화하기 위한 Carboxymethylcellulose Sodium Salt [CMC] 담체의 이용성 연구)

  • 이용제;정성제;허문석;전억한
    • KSBB Journal
    • /
    • v.15 no.1
    • /
    • pp.49-54
    • /
    • 2000
  • Bioluminescence of Photobacterium phosphoreum has been used for the detection of pollutants in the environment. Immobilization method was used to maintain the stability of bioluminescence of P. phosphoreum. The carboxymethylcellulose was investigated to find out whether it was suitable for the immobilization of P. phosphoreum as a matrix without disturbing the bioluminescence emission. A maintenance of bioluminescence was determined from the P. phosphoreum immobilized on the various concentrations of carboxymethylcellulose. A relatively high bioluminescence intensity was shown with immobilized cells on 1%(w/v) carboxymethylcellulose. The effect of carboxymethylcellulose concentrations on the sensitivity of Crcompounds including $Na_{2}CrO_{4}$, $K_{2}CrO_{4}$, $CrO_{3}$, CrK$(SO_4)_{2}$ and $CrCl_{3}$ to the bioluminescence intensity. The calculated $EC_{50}$ showed that the linear relations between such substances and bioluminesence intensity were established.

  • PDF

Effects of Grassed Swale Lengths on Reduction Efficiencies of Non-point Source Pollutants (식생수로 길이가 비점오염물질 저감효율에 미치는 영향)

  • Paek, Seoungbong;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.15 no.3
    • /
    • pp.387-396
    • /
    • 2013
  • Non-point pollution source is difficult to control due to uncertain outflow path and emission. So, There are many development and research to Best Management Practices(BMP) established to manage the Non-point pollution source. Besides, various methods of estimated efficiency to exact assessment of BMP is presented. In this study, the impact about length of Grassed Swale on reduction efficiency based on monitoring results of Grassed Swale by length is studied. By estimating Grassed Swale reduction efficiency in a variety of methods, the difference between the methods of estimated efficiency was compared with those that. Estimated efficiency method using ER, SOL, ROL, ROF, SOLF, and ROLF methods is analyzed. EMC analysis result is high inflow and outflow concentration distinction organic compound for nutritive salts The result of efficiency analysis along Grassed Swale length sharply increases in a Grassed Swale inlet. After this increase, the efficiency gradually decreases. This is expected that cistern installed in the end of the front. To obtain a stable reduction efficiency of Grassed Swale, minimum length 30m of Grassed Swale should be enough. Also, in order to efficiently and economically design Grassed Swale, the researches on length of Grassed Swale are needed rather than simple analysis of efficiency.

Study on Characteristics of Change of Urea and Biuret Content by Temperature Variation in Urea Solution (요소수(Urea solution)의 온도변화에 따른 요소 및 뷰렛함량 변화 특성 연구)

  • Doe, Jin-woo;Park, Tae-sung;Lee, Yu-rim;Yim, Eui-soon;Lee, Joung-min;Kang, Hyung-kyu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.1307-1319
    • /
    • 2018
  • As interests in the air pollution increases, many kinds of researches are underway on the reduction of air pollutants. The removal of nitrogen oxides from the emission gas of diesel vehicles using urea solution has shown a great effect. The quality of urea solution is strictly defined by domestic law, but the increase of impurities in urea solution reduces the effect of reducing nitrogen oxides. Therefore, in this study, the change of physical properties of urea solution was analyzed after heating the urea solution for a certain temperature and time. Also, the changes of physical properties of urea solution were analyzed according to kinds of storage container and temperature for storing the urea solution. After heating the urea solution for a certain period of time, the biuret content in urea solution increased and the content of urea decreased. As the urea content decreased, both density and refractive index decreased. In the storage stability test carried out at a constant temperature with iron and PET containers, no change in physical properties was observed.

Evaluation of Ventilation Deficiecy in Elementary, Middle, and High Schools using Monte Carlo Simulation (Monte-Carlo 모의실험을 이용한 초·중·고등학교의 환기부족 평가)

  • Choe, Youngtae;Park, Jinhyeon;Kim, Eunchae;Ryu, Hyoensu;Kim, Dong Jun;Min, Kihong;Jung, Dayoung;Woo, Byung Lyul;Cho, Mansu;Yang, Wonho
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.6
    • /
    • pp.627-635
    • /
    • 2020
  • Objectives: Indoor air quality has become more important aspeople spend most of their times indoors. Since students spend most of their times at home or at school, they are more likely to be exposed to indoor air pollutants. Ventilation in school classrooms can affect health and learning performance. In this study, ventilation deficiency was evaluated in school classrooms using Monte Carlo simulation. Methods: This study used sensor-based monitoring for six months to measure carbon dioxide (CO2) concentrations in classrooms in elementary, middle, and high schools. The volume of the classroom and the number of students were investigated, and the students' body surface area was used to calculate the CO2 emission rate. The distribution of ventilation rates was estimated by measured CO2 concentration and a mass-balance model using Monte Carlo simulation. Results: In the elementary, middle, and high schools, the average CO2 concentrations exceeded 1000 ppm, indicating that the ventilation rates were insufficient. The ventilation rates were deficient from July to August and in December, but showed relatively high ventilation rates in October. Forty-three percent of elementary schools, 56% of middle schools, and 62% of high schools showed insufficient ventilation rates. Conclusions: The ventilation rates calculated in elementary, middle and high schools were found to be quite insufficient. Therefore, proper management is needed to overcome the lack of ventilation and improve air quality.