• Title/Summary/Keyword: Emission factors

Search Result 923, Processing Time 0.027 seconds

A Study on Calculation of Air Pollutants Emission Factors for Construction Equipment (건설기게의 대기오염물질 배출계수 산정을 위한 연구)

  • lim, Jae-Hyun;Jung, Sung-Woon;Lee, Tae-Woo;Kim, Jong-Choon;Seo, Chung-Youl;Ryu, Jung-Ho;Hwang, Jin-Woo;Kim, Sun-Moon;Eom, Dong-Sup
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.3
    • /
    • pp.188-195
    • /
    • 2009
  • Generally. mobile sources of air pollution were classified in on-road and non-road. Due to increased registration number of construction equipment in Korea. updated emission factors for non-road mobile sources, such as construction machinery. should be developed. NONROAD model of U.S. EPA already has introduced transient adjustment factors and sulfur adjustment factors for emission factors of diesel powered engine. In addition to this. European Environment Agency (EEA) has proposed emission factors for off-road machinery including several types of construction equipment. In this study. six types of construction equipment, such as excavator. forklift, loader, crane, roller and bulldozer, were studied to estimate emission factors based on total registration status in Korea. Total 445 construction equipments between 2004 and 2007 model year were tested with KC1-8 mode and air pollutants (CO, THC, $NO_x$, and PM) were measured. After statistical estimation and calculation, emission factors for CO, THC, $NO_x$, and PM for excavator, forklift, loader, crane, roller and bulldozer were provided and compared with previous emission factors. Moreover, updated emission factors for six types of construction equipment in this study were verified after comparison with emission factors of U.S. EPA. Finally, estimated emission amounts of four air pollutants were suggested according to six types of construction equipment.

Development of Chassis Dynamometer Test Modes to Derive the Emission Factors for Light Duty Vehicles (소형자동차 배출계수 산출용 차대동력계 시험모드의 개발)

  • 이영재;김강출;표영덕;선우명호;엄명도
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.6
    • /
    • pp.117-124
    • /
    • 2002
  • For the correct estimation of air pollutant emission from automobiles which is the largest contributor of metropolitan area air pollution, the total pollutant emission from automobiles should be estimated accurately. Nationwide emissions from automobiles, such as CO, HC and NOx, are calculated by using emission factor and total VMT(vehicle miles traveled). The emission factors were derived from the emissions data on chassis dynamometer with test modes which represent the real driving patterns. In the present study, test modes to derive the emission factors for light duty vehicles are developed by using the real driving pattern data for the urban, suburban and express way.

Development of Estimation Methods of Pollutant Emissions from Railroad Diesel Rolling Stocks (철도디젤차량에서 배출되는 오염물질의 배출량 산정방법 개발)

  • 박덕신;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.4
    • /
    • pp.539-553
    • /
    • 2004
  • Up to the present time, many methods to estimate emissions from a particular diesel engines have wholly depended on the quantity of diesel fuel consumed. Then, the recommended emission factors were normalized by fuel consumption, and further total activity was estimated by the total fuel consumed. One of main purposes in the study is newly to develop emission factors for the railroad diesel rolling stock (RDRS) and to estimate a total amount of major gaseous pollutants from the RDRS in Korea. Prior to develop a Korean mode emission factor. the emission factor from the USEPA was simply applied for comparative studies. When applying the USEPA emission factors, total exhaust emissions from the RDRS in Korea were estimated by 28,117tons of NOx, 2,832.3tons of CO, and 1,237.5tons of HC, etc in 2001. In this study, a emission factor for the RDRS, so called the KoRail mode (the Korean Railroad mode) has been developed on the basis of analyzing the driving pattern of the Gyeongbu-Line especially for the line-haul mode. Explicitly to make the site specific emission factors, many uncertainty problems concerning weighting factors for each power mode, limited emission test, incomplete data for RDRS, and other important input parameters were extensively examined. Total exhaust emissions by KoRail mode in Korea were estimated by 10,960tons of NOx, and 4,622tons of CO, and so on in the year of 2001. The emissions estimated by the USEPA mode were 2.6 times higher for NOx, and 1.6 times lower for CO than those by the KoRail mode. As a conclusion, based on the emission calculated from both the USEPA mode and the KoRail mode, the RDRS is considered as one of the significant mobile sources for major gaseous pollutants and thus management plans an(1 control strategies for the RDRS must be established to improve air quality near future in Korea.

A Study on Estimation of NOx and CO Emission Factor from Industrial and Commercial LNG Boilers (천연가스 사용 난방 및 산업보일러의 NOx와 CO 배출계수 산정 연구)

  • Jang, Young-Kee;Choi, Sang-Jin;Kim, Kwan;Song, Ki-Pong;Kim, Ho-Jung;Jung, Bong-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.5
    • /
    • pp.615-623
    • /
    • 2004
  • This study was conducted for developing the emission factors of nitrogen oxide(NOx) and carbon monoxide (CO) from the combustion boilers burning liquefied natural gas (LNG). These emission factors were compared with those of U.S. EPA and European Environment Agency (EEA). NOx and CO concentration in the flow gas were measured using Kane-May, KM9106 and Thermo Environmental Instruments Inc., 42C-HL. Measurement were conducted at thirty industrial and commercial LNG boilers. Emission factors were calculated on the basis of fuel consumption (kg-pollutant/㎥-fuel burned). NOx concentration at industrial boiler was 14~125 ppm and it was measured as 35~125 ppm at commercial boiler. NOx emission factors of industrial boiler and commercial boiler were 1.84kg/$m^3$ and 2.09kg/$m^3$, respectively. NOx emission factor of commercial boiler was higher than that of industrial boiler. The NOx emission factors estimated in this study were lower than those of U.S. EPA and higher than those of EEA. Average CO emission factor of industrial boiler was 0.65 kg/$m^3$ and at commercial boiler it was 0.70kg/$m^3$, CO emission factor at industrial boiler was lower than that at commercial boiler.

A Study on the Estimation of Air Pollutants Emission Factors in Electric Power Plants (화력발전소의 대기오염물질 배출계수 산정 연구)

  • 김대곤;엄윤성;홍지형;이석조;석광설;이대균;이은정;방선애
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.3
    • /
    • pp.281-290
    • /
    • 2004
  • The main purpose of this study was to characterize the air pollutants emission factors in electric power plant (EPP) using fossil fuels. The electric power plant is a major air pollution source, thus knowing the emission characteristics of electric power plant is very important to develop a control strategy. The major air pollutants of concern from EPP slacks are particulate matter (PM), sulfur oxides (SOx), nitrogen oxides (NOx), carbon monoxide (CO) and heavy metals. Throughout the study, the following results are estimated - PM : 8.671E-05 ∼ 8.724E+01 PM emission (kg) per fuel burned (ton) - SOx : 4.149E-04∼7.877E+01 SOx emission (kg) per fuel burned (ton) - NOx 1.578E-02∼9.857E+00 NOx emission (kg) per fuel burned (ton) - CO : 3.800E-04∼1.291E+00 CO emission (kg) per fuel burned (ton) - Hg : 1.220E+01∼3.108E+02 Hg emission (mg) per fuel burned(ton) From the statistical analysis by Wilcoxon signed ranks test between the emission factors of ours and U.S. EPA's, we can yielded that : p 〉0.05.

Determination of Weighted Value to Estimate Each Emission Factor of Landfill (폐기물 매립부문 배출계수 평가항목의 가중치 결정)

  • Lee, Seung Hoon;Kim, Jae Young;Yi, Seung Muk;Choi, Eun Hwa;Kim, Young Soo
    • Journal of Climate Change Research
    • /
    • v.5 no.3
    • /
    • pp.199-208
    • /
    • 2014
  • According to "IPCC guide line for national greenhouse gas inventories" each country should develop the 'Country-specific emission factor' and apply it to estimate greenhouse gases emissions from landfill. It could reflect properties of country and make estimation more accurate. For that accuracy, developed country-specific emission factor should be assessed and be verified consistently. Developed emission factors should be assessed in terms of Representative, Emission Property, Accuracy and Uncertainty, but there is no study about weighted assessment factors under each emission variable. This study do survey targeting public officials, professors and other experts for Analytical Hierarchy Process(AHP), mostly use to make decisions, to weight assessment factors. We investigated the weighted values per Emission factor for Representative, Emission property, Accuracy and Uncertainty on AHP survey, and Representative factor was the highest, and then in the order of Emission property (0.26), Accuracy(0.22), Uncertainty (0.15).

Development of Emission Factors for Greenhouse Gas (CO2) from Bituminous coal Fired Power Plants (에너지사용시설의 온실가스 배출 특성 연구 -유연탄 화력발전소의 이산화탄소를 중심으로-)

  • Jeon Eui Chan;Sal Jae Whan;Lee Seong Ho;Jeong Jae Hak;Kim Ki Hyun;Bae Wi Sup
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.1
    • /
    • pp.107-116
    • /
    • 2006
  • The main purpose of this study is to develop the greenhouse gas emission factor for power plant using bituminous coal. The power plant is a major source of greenhouse gases among the sectors of fossil fuel combustion, thus information of its emission factors is very essential to the establishment of control strategies for the greenhouse gas emissions. These emission factors derived in this study were compared with those of U. S. EPA, AGO and CCL. The $CO_{2}$ concentrations in the flue gas were measured using NDIR analyser and the GC-FID with a methanizer. The amount of carbon (C) and hydrogen (H) in fuel was measured using an elemental analyzer. Calorific values of fuel were also measured using a calorimeter. Caloric value of bituminous coal used in the power plants were 5,957 (as received basis), 6,591 (air-dried basis) and 6,960 kcal/kg (dry basis). Our estimates of carbon emission factors were lower than those of IPCC. The CO2 emission factors for the power plants using bituminous coal were estimated to be 0.791 Mg/MWh (by carbon contents and caloric value of the fuel) and 0.771 Mg/MWh (by $CO_{2}$ concentration of the flue gas). The $CO_{2}$ emission factors estimated in this study were $3.4\sim 5.4\%$ and $4.4\sim 6.7\%$ lower than those of CCL (2003) and U. S. EPA (2002).

Assessment of PM Emission Factors Made by Construction Machineries (건설현장의 공사장비에 의한 미세먼지 배출계수 평가)

  • Lee, Im Hack;Lee, Kyoung Bin;Kim, Jin Sik;Kim, Shin Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.4
    • /
    • pp.311-318
    • /
    • 2014
  • The goles of this study were that we calculated the difference between the emission factors currently used officially and the emission factors that calculated by atmospheric dispersion modeling results and actual field measurements of dust concentrations and that we investigated how we applied to the emission factors appropriate to the reality in Korea. At the results, we calculated the Business As Usual ambient dust concentration concerning U.S. EPA method emissions, and we thought that the emission reduction efficiency had to be 99.7% if the ambient dust concentration that measured in this study could be satisfied. In other words, U.S. EPA dust emission calculation method is very overestimated than reality, so it is important that our country obtain reliable construction site dust emissions estimation methods by continuous researches.

A Study on Estimation of Air Pollutants Emission from Residential Wood Stove (주거용 화목난로의 대기오염 배출량 추정에 관한 연구)

  • Kim, Pil-Su;Jang, Young-Kee;Kim, Jeong;Shin, Yong-Il;Kim, Jeong-Soo;An, Jun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.3
    • /
    • pp.276-285
    • /
    • 2010
  • Recently the Korean government has tried to cut down the $PM_{10}$ concentration by the Special Law for Air Quality Improvement. But the concentrations of $PM_{10}$ have exceeded the air quality standard at most monitoring stations. Primary $PM_{10}$ emitted from various sources and emission data have large uncertainty. The biomass burning is one of the major sources of $PM_{10}$ emission. The biomass burning is composed of wood stove usage, meat cooking and agricultural combustion etc.. Activity data and emission factors for the biomass burning are limited, and it is hard to calculate the air pollution emissions from these sources. In this study, we tried to estimate the air pollution emission from residential wood stove usage. The number of total wood stoves is estimated by the survey of wood stove manufacturer. And air pollution emission factors for the wood stove are investigated using the flue gas measurement by U.S. EPA particulate test method (Method 5G). As the results, the $PM_{10}$ and CO emission factors of wood stove are estimated as 7.7 g/kg-wood and 78.8 g/kg-wood respectively. The annual $PM_{10}$ and CO emissions from wood stove are calculated as 1,200~3,600 ton/year and 12,600~36,400 ton/year in Korea. It is confirmed that wood stove is the one of major sources of biomass burning, and the survey for activity data and the measurement for emission factors are needed for reducing the uncertainty of these emission data.

Estimation of Emission and Development of Emission Factor on Greenhouse Gas (CO2) of the Combustion Facilities (연소시설의 온실가스(CO2) 배출량 산정 및 배출계수개발)

  • Kim, Hong-Rok;Jin, Byong-Bok;Yoon, Wan-Woo;Kwon, Young-Sung;Lee, Min-Young;Yoon, Young-Bong;Shin, Won-Geun
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.4
    • /
    • pp.277-283
    • /
    • 2007
  • Since the Kyoto Protocol became into effect, Korea has been expected to be part of the Annex I countries performing the duty of GHG reduction in the phase of post-Kyoto. Therefore, it is necessary to develop emission factors appropriate to Korean circumstances. In order to develop emission factors this study utilized the CleanSYS, which is the real-time monitoring system for industrial smoke stacks to calculate the emission rate of $CO_2$ continuously. In this study, the main focus was on the power generation plants emitting the largest amount of $CO_2$ among the sectors of fossil fuel combustion. Also, an examination on the comparison of $CO_2$ emission was made among 3 generation plants using the different types of fuels such as bituminous coal and LNG; one for coal and others for LNG. The $CO_2$ concentration of the coal fired plant showed Ave. 13.85 %(10,384 ton/day). The LNG fired plants showed 3.16 %(1,031 ton/day) and 3.19 %(1,209 ton/day), respectably. Consequently, by calculating the emission factors using the above results, it was found that the bituminous coal fired power plant had the $CO_2$ emission factor average of 88,726 kg/TJ, and the LNG fired power plants had the $CO_2$ average emission factors of 56,971 kg/TJ and 55,012 kg/TJ respectably which were similar to the IPCC emission factor.