• Title/Summary/Keyword: Emission Test

검색결과 1,624건 처리시간 0.035초

Comparative Analysis of the Physical and Biochemical Properties of Light-cure Resin-modified Pulp Capping Materials

  • Tae Gyeom Kim;Jongsoo Kim;Joonhaeng Lee;Jisun Shin;Mi Ran Han;Jongbin Kim;Yujin Kim;Jae Hee Park
    • 대한소아치과학회지
    • /
    • 제51권2호
    • /
    • pp.149-164
    • /
    • 2024
  • This study compared the solubility, water absorption, dimensional stability, release of various ions (hydroxyl, calcium, sulfur, strontium, and silicon), and cytotoxicity of light-cured resin-modified pulp-capping materials. Resin-modified calcium hydroxide (Ultra-blendTM plus, UBP), light-cured resin-modified calcium silicate (TheraCal LCTM, TLC), and dual-cure resin-modified calcium silicate (TheraCal PTTM, TPT) were used. Each material was polymerized; solubility, 24-hour water absorption, and 30- day dimensional stability experiments were conducted to test its physical properties. Solubility was assessed according to the ISO 6876 standard, and 24 hours of water absorption, 30 days of dimensional stability were assessed by referring to the previous protocol respectively. Eluates at 3 and 24 hours and on 7, 14, and 28 days were analyzed according to the ISO 10993-12 standard. And the pH, Ion-releasing ability, cell proliferation rate, and cell viability were assessed using the eluates to evaluate biochemical characteristics. pH was measured with a pH meter and Ion-releasing ability was assessed using inductively coupled plasma atomic emission spectrometry (ICP-AES). Cell proliferation rate and cell viability were assessed using human dental pulp cells (hDPCs). The former was assessed by an absorbance assay using the CCK-8 solution, and the latter was assessed by Live and Dead staining. TPT exhibited lower solubility and water absorption than TLC. UBP and TPT demonstrated higher stability than TLC. The release of sulfur, strontium, calcium, and hydroxyl ions was higher for TLC and TPT than for UBP. The 28-day release of hydroxyl and silicon ions was similar for TLC and TPT. TLC alone exhibited a lower cell proliferation rate compared to the control group at a dilution ratio of 1 : 2 in cell proliferation and dead cells from Live and Dead assay evaluation. Thus, when using light-cure resin-modified pulp-capping materials, calcium silicate-based materials can be considered alternatives to calcium hydroxide-based materials. Moreover, when comparing physical and biochemical properties, TPT could be prioritized over TLC as the first choice.

부갑상선: 부갑상선 영상에 익숙하지 않은 영상의학과 의사들을 위한 전반적인 검토 (The Parathyroid Gland: An Overall Review of the Hidden Organ for Radiologists)

  • 김수호;신정희;한수연;김해정;김명경
    • 대한영상의학회지
    • /
    • 제85권2호
    • /
    • pp.327-344
    • /
    • 2024
  • 부갑상선은 부갑상선 호르몬(parathyroid hormone; 이하 PTH)을 생성하여 칼슘 대사를 조절하는 작은 내분비선으로 구성되어 있다. 일반적으로 갑상선 뒤에 4개의 부갑상선이 위치해 있으나 개수 또는 위치는 개인차가 있으며 4개보다 많거나 적은 경우들이 있다. 부갑상선 질환은 부갑상선 기능 장애와 관련이 있으며, 부갑상선 자체의 문제 또는 신장질환으로 인한 비정상적인 혈청 칼슘 수치로 인해 발생할 수 있다. 최근 건강검진이 보편화되면서 우연히 비정상적으로 높은 혈청 칼슘 값이 발견되어 PTH 검사, 초음파, 테크네튬-99m 세스타 미비 부갑상선 스캔, 단일광자방출단층촬영/컴퓨터단층촬영(SPECT/CT), 4차원 컴퓨터단층촬영(4D-CT), 그리고 양전자방출단층촬영/컴퓨터단층촬영(PET/CT) 등의 추가적인 검사가 시행된다. 그러나 부갑상선은 여전히 영상의학과 의사에게 익숙하지 않은 기관이다. 이 종설에서 부갑상선의 해부학, 병태생리, 영상 및 임상 소견에 대해 알아보고자 한다.

대기 누출 방사성물질 선원 위치 추적을 위한 3차원 궤적모델 개발 (Development of Three-Dimensional Trajectory Model for Detecting Source Region of the Radioactive Materials Released into the Atmosphere)

  • 서경석;박기현;민병일;김소라;양병모
    • Journal of Radiation Protection and Research
    • /
    • 제41권1호
    • /
    • pp.31-39
    • /
    • 2016
  • 연구배경: 우리나라를 포함한 중국, 대만, 북한, 일본 등에서 원전, 재처리시설과 같은 원자력시설의 증가에 따라 주변국 핵활동 분석의 종합적 대책이 필요하다. 우리나라와 포괄적핵실험금지조약기구(Comprehensive Nuclear-Test-Ban Treaty Organization, CTBTO)는 동북아시아 지역에서 핵종 탐지소를 운영 중으로, 핵종탐지 장비에서 특이 값 측정시 모니터링 자료의 분석과 더불어 배출원 탐색모델을 이용하여 핵종의 기원이 어디인지 추정하고 평가하는 것은 주변국 핵활동에 대한 감시 및 안전성 확보 측면에서 중요하다. 재료 및 방법: 주변국의 은밀한 핵활동 시 방사성핵종의 기원을 추정하기 위하여 3차원 전진/후진형 궤적모델을 개발하였다. 개발된 궤적모델은 궤적 미분방정식을 유한차분법을 이용한 방법으로 주어진 바람자료를 이용하여 방사성핵종의 방출지점으로부터 입자의 궤적을 순차적으로 찾아가는 전진형 모델과 시간 역산으로 방출기원을 추정하는 후진형 모델로 구성되었다. 결과 및 논의: 개발된 궤적모델의 검증을 위하여 체르노빌 사고 당시 측정된 농도자료를 이용하였다. 검증결과 관측지점의 농도가 높게 측정된 지점과 방출기원에서 가까운 지역으로부터 시간 역산의 방출지점을 추정한 결과의 정확도가 높았다. 3차원 궤적모델은 방출시간, 방출높이, 방출간격 등의 변수에 의해 계산결과가 달라지는 불확도를 내포하고 있는데, 이러한 궤적모델의 불확도를 최소화하기 위해 한국원자력연구원에서 개발한 대기확산모델(long-range accident dose assessment system, LADAS)를 이용하여 fields of regards (FOR) 기법에 의해 오염물 방출영역을 추정한바 신뢰성 있는 결과를 얻었다. 결론: 본 연구를 통하여 개발된 배출원 탐색모델은 주변국의 은밀한 핵활동 시 핵종 탐지장비와 연계하여 방사성핵종의 방출지역과 기원을 파악하여 우리나라의 핵종탐지 능력을 향상하고 핵활동 및 방사선 안전 분야에서 주도적 역할을 할 수 있을 것으로 생각된다.

아말감의 구강내 부식 및 인공 부식에 관한 연구 (A STUDY ON IN VIVO AND IN VITRO AMALGAM CORROSION)

  • 임병목;권혁춘;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.1-33
    • /
    • 1997
  • The objective of this study was to analyze the in vitro and in vivo corrosion products of low and high copper amalgams. The four different types of amalgam alloy used in this study were Fine cut, Caulk spherical, Dispersalloy, and Tytin. After each amalgam alloy and Hg were triturated according to the directions of the manufacturer by means of the mechanical amalgamator(Amalgam mixer. Shinhung Co. Korea), the triturated mass was inserted into a cylindrical metal mold which was 12mm in diameter and 10mm in height. The mass was condensed by 150Kg/cm compressive force. The specimen was removed from the mold and aged at room temperature for about seven days. The standard surface preparation was routinely carried out by emery paper polishing under running water. In vitro amalgam specimens were potentiostatically polarized ten times in a normal saline solution at $37^{\circ}C$(potentiostat : HA-301. Hukuto Denko Corp. Japan). Each specimen was subjected to anodic polarization scan within the potential range -1700mV to+400mV(SCE). After corrosion tests, anodic polarization curves and corrosion potentials were obtained. The amount of component elements dissolved from amalgams into solution was measured three times by ICP AES(Inductive Coupled Plasma Atomic Emission Spectrometry: Plasma 40. Perkim Elmer Co. U.S.A.). The four different types of amalgam were filled in occlusal and buccal class I cavities of four human 3rd molars. After about five years the restorations were carefully removed after tooth extraction to preserve the structural details including the deteriorated margins. The occlusal surface, amalgam-tooth interface and the fractured surface of in vivo amalgam corrosion products were analyzed. In vivo and in vitro amalgam specimens were examined and analyzed metallographically by SEM(Scanning Electron Microscope: JSM 840. Jeol Co. Japan) and EDAX(Energy Dispersive Micro X-ray Analyser: JSM 840. Jeol Co. Japan). 1. The following results are obtained from in vitro corrosion tests. 1) Corrosion potentials of all amalgams became more noble after ten times passing through the in vitro corrosion test compared to first time. 2) After times through the test, released Cu concentration in saline solution was almost equal but highest in Fine cut. Ag and Hg ion concentration was highest in Caulk spherical and Sn was highest in Dispersalloy. 3) Analyses of surface corrosion products in vitro reveal the following results. a)The corroded surface of Caulk spherical has Na-Sn-Cl containing clusters of $5{\mu}m$ needle-like crystals and oval shapes of Sn-Cl phase, polyhedral Sn oxide phase. b)In Fine cut, there appeared to be a large Sn containing phase, surrounded by many Cu-Sn phases of $1{\mu}m$ granular shapes. c)Dispersalloy was covered by a thick reticular layer which contained Zn-Cl phase. d)In Tytin, a very thin, corroded layer had formed with irregularly growing Sn-Cl phases that looked like a stack of plates. 2. The following results are obtained by an analysis of in vivo amalgam corrosion products. 1) Occlusal surfaces of all amalgams were covered by thick amorphous layers containing Ca-P elements which were abraded by occlusal force. 2) In tooth-amalgam interface, Ca-P containing products were examined in all amalgams but were most clearly seen in low copper amalgams. 3) Sn oxide appeared as a polyhedral shape in internal space in Caulk spherical and Fine cut. 4) Apical pyramidal shaped Sn oxide and curved plate-like Sn-Cl phases resulted in Dispersalloy. 5) In Tytin, Sn oxide and Sn hydroxide were not seen but polyhedral Ag-Hg phase crystal appeared in internal space which assumed a ${\beta}_l$ phase.

  • PDF

선박 배연탈질용 금속 구조체 기반 촉매 제조를 위한 코팅슬러리 최적화 (Optimum Synthesis Conditions of Coating Slurry for Metallic Structured De-NOx Catalyst by Coating Process on Ship Exhaust Gas)

  • 정해영;김태용;임은미;임동하
    • 청정기술
    • /
    • 제24권2호
    • /
    • pp.127-134
    • /
    • 2018
  • 국제해사기구에서는 선박 배기가스 내 질소산화물($NO_x$) 배출에 대한 강화된 Tier III 규제가 2016년부터 적용됨에 따라 이를 대응하기 위한 노력이 필요하다. $NO_x$ 저감 방법으로 선택적 촉매 환원법(Selective catalytic reduction, SCR)을 주로 사용하고 있으며, 세라믹 허니컴 촉매를 주로 사용하고 있다. 그러나 기존의 세라믹 허니컴 촉매는 약한 강도로 인하여 운전상 문제가 발생하거나 유지 및 보수에 있어서도 어려움을 갖는 단점을 가지고 있다. 본 연구에서는 세라믹 허니컴 촉매의 단점들을 보완하기 위하여 높은 열적 안정성과 기계적 강도를 가짐과 동시에 배기가스의 다방향성 이동을 통한 낮은 배압효과 등의 장점을 가지는 금속 지지체를 적용하였다. 이러한 금속 지지체 상에 촉매를 담지하기 위하여 유 무기바인더 첨가를 통해 코팅슬러리를 제조하고, 이를 코팅, 건조 및 소성과정을 통해 금속 지지체 상에 견고하게 부착된 금속 지지체 기반 촉매를 제조하였다. 이러한 금속 지지체 기반 촉매는 $NO_x$ 성능평가와 초음파 및 낙하시험을 통한 접착 내구성 평가를 수행하였다. 특히, 무기바인더를 첨가한 MFC01경우 95% 이상의 $NO_x$ 전환율을 보였으며, 상용 세라믹 허니컴 촉매보다도 우수한 내구성을 보였다. 이러한 특성 및 성능평가를 통하여 개발된 금속 지지체 기반 촉매는 고효율, 고내구성을 가짐을 확인하였으며, 기존 세라믹 허니컴 촉매를 대체할 수 있는 선박용 배연탈질 촉매로서의 가능성을 확인하였다.

Antifungal effects of synthetic human β-defensin 3-C15 peptide

  • Lim, Sang-Min;Ahn, Ki-Bum;Kim, Christine;Kum, Jong-Won;Perinpanayagam, Hiran;Gu, Yu;Yoo, Yeon-Jee;Chang, Seok Woo;Han, Seung Hyun;Shon, Won-Jun;Lee, Woocheol;Baek, Seung-Ho;Zhu, Qiang;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • 제41권2호
    • /
    • pp.91-97
    • /
    • 2016
  • Objectives: The purpose of this ex vivo study was to compare the antifungal activity of a synthetic peptide consisting of 15 amino acids at the C-terminus of human ${\beta}$-defensin 3 (HBD3-C15) with calcium hydroxide (CH) and Nystatin (Nys) against Candida albicans (C. albicans) biofilm. Materials and Methods: C. albicans were grown on cover glass bottom dishes or human dentin disks for 48 hr, and then treated with HBD3-C15 (0, 12.5, 25, 50, 100, 150, 200, and $300{\mu}g/mL$), CH ($100{\mu}g/mL$), and Nys ($20{\mu}g/mL$) for 7 days at $37^{\circ}C$. On cover glass, live and dead cells in the biomass were measured by the FilmTracer Biofilm viability assay, and observed by confocal laser scanning microscopy (CLSM). On dentin, normal, diminished and ruptured cells were observed by field-emission scanning electron microscopy (FE-SEM). The results were subjected to a two-tailed t-test, a one way analysis variance and a post hoc test at a significance level of p = 0.05. Results: C. albicans survival on dentin was inhibited by HBD3-C15 in a dose-dependent manner. There were fewer aggregations of C. albicans in the groups of Nys and HBD3-C15 (${\geq}100{\mu}g/mL$). CLSM showed C. albicans survival was reduced by HBD3-C15 in a dose dependent manner. Nys and HBD3-C15 (${\geq}100{\mu}g/mL$) showed significant fungicidal activity compared to CH group (p < 0.05). Conclusions: Synthetic HBD3-C15 peptide (${\geq}100{\mu}g/mL$) and Nys exhibited significantly higher antifungal activity than CH against C. albicans by inhibiting cell survival and biofilm.

DTG 분석법을 활용한 슬래그류 비탄산염 재료의 CO2 정량 측정방법 연구 (A Study on the Method for Quantifying CO2 Contents in Decarbonated Slag Materials by Differential Thermal Gravimetric Analysis)

  • 최재원;유병노;추용식;한민철
    • 한국건설순환자원학회논문집
    • /
    • 제12권1호
    • /
    • pp.8-16
    • /
    • 2024
  • 포틀랜드 시멘트, 철강 산업 등에서 원료로 사용되는 석회석(CaCO3, calcium carbonate)은 고온에서 탈탄산 분해 반응에 의해 CO2를 배출한다. 석회석 사용에 의한 CO2 배출을 저감하기 위해 CO2 배출의 원인이 되는 carbonate 광물을 함유하지 않거나 함유량이 적으면서도 CaO를 함유한 산업부산물로 석회석을 대체하려는 기술이 제안되었다. 이들 산업부산물에 함유된 CO2를 정량 측정하는 방법으로 Loss of Ignition(LOI), Thermo-Gravimetric Analysis(TG), Infrared Spectroscopy(IR) 등이 사용되나, 산업부산물의 특성에 따라 CO2 배출량을 과대 또는 과소 평가할 우려가 있다. 본 연구에서는 CaCO3 시료와 고온에서 산화반응에 의해 중량이 증가하는 시료 각각에 carbonate 형태로 함유된 CO2의 함량을 측정하는 방법으로 LOI, TG, IR 및 DTG(Differential Thermo-Gravimetric Analysis) 방법의 신뢰도와 시험방법별 측정결과를 비교 검토하였다. CaCO3 시료에 대해서는 검토한 모든 시험결과는 충분한 수준의 신뢰도를 나타내었다. 반면, 고온에서 중량이 증가하는 시료의 CO2 함량에 대해서는 LOI와 TG는 시료의 CO2 함량을 제대로 평가하지 못했으며, IR은 예측값에 비해 CO2 함량을 과대평가하는 경향을 나타내었으나, DTG에 의한 평가 결과는 예측값에 근사하였다. 이로부터 수 % 미만 수준의 미량의 CO2를 함유하고, carbonate 광물의 분해 배출 온도에서 CO2 배출에 의한 중량 감소 외에도 중량이 변화하는 시료의 경우 DTG를 이용하여 CO2 함량을 구하는 것이 LOI나 TG, IR을 이용한 평가보다 합리적이라고 판단된다.

전신 PET/CT 검사에서 팔의 위치에 따른 감약 정도와 SUV 변화 평가 (The Evaluation of Attenuation Difference and SUV According to Arm Position in Whole Body PET/CT)

  • 곽인석;이혁;최성욱;석재동
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.21-25
    • /
    • 2010
  • PET/CT검사에 있어서 CT는 해부학적인 정보를 제공할 뿐 아니라 PET영상에 대한 감약 정보를 제공하는 역할을 하고 있다. CT의 감약차를 이용하는 것으로서 검사 부위에 존재하는 여러 가지 변수에 의해 그 정도가 달라질 수 있다. 이것은 현재 본 원에서 PET/CT검사 시에 팔을 몸 옆에 두고 검사하는 것에도 적용할 수 있으며, 이에 본 논문에서는 일부 타 병원에서 시행하고 있는 팔을 머리 위로 올리고 검사하는 방법과 함께 CT값의 변화에 따른 표준섭취계수의 변화를 비교 연구했다. NEMA 1994 PET 모형의 삽입체와 모형의 부피를 고려하여 4:1의 비율로 $^{18}F$-FDG를 주입하였다. 먼저 테플론 삽입체 두 개를 NEMA 1994 PET 모형의 양 옆에 고정시켜 팔을 내리고 있는 상태를 가정하여 영상을 얻었으며 테플론 삽입체를 제거하여 팔을 머리 위로 올린 상태를 가정하여 영상을 얻었다. 앞의 과정을 거쳐 얻은 영상을 재구성 하여 Volume Viewer를 이용해 한 영상면 당 5개의 관심 체적을 설정했고 각 측정값을 평균하여 얻어낸 CT값과 표준섭취계수로 그 변화를 측정하였다. 측정된 값과 폐 관련 암환자의 간에 관심 영역을 설정하고 측정한 값을 비교하여 실제 임상 영상에서의 차이를 측정하였다. 모형 실험결과 테플론 삽입체를 부착하였을 때보다 테플론 삽입체를 부착하지 않았을 때 CT값이 -5.8 HU에서 0 HU으로 평균 5.8 HU 증가하였고 표준섭취계수는 24.64에서 24.29로 평균 0.35 감소하였다. 축방향 균일도는 0.064에서 0.052로 평균 0.012 감소하였다. 환자 실험결과 팔을 내리고 검사하였을 때보다 팔을 머리 위로 올리고 검사하였을 때 CT값은 54.1 HU에서 59.9 HU로 평균 5.8 HU 증가하였고 표준섭취계수는 2.02에서 1.85로 평균 0.17 감소하였다. 테플론 삽입물을 부착한 상태로 검사할 때 보다 테플론 삽입물을 부착하지 않은 상태로 검사할 때 CT값은 증가하고 표준섭취계수는 감소하는 양상을 보였다. 이러한 현상이 일어나는 이유는 감약의 정도와 표준섭취계수의 상관관계에서 찾을 수 있다. CT값이 증가할수록 감약 계수는 비례하여 증가하는데 이것은 결국 CT값이 증가될수록 감약이 증가된다고 볼 수 있다. 따라서 팔에 의해 감약이 과다하게 측정될 수 있으므로 결국 표준섭취계수의 증가로 이어진다고 판단된다. 하지만 그 값의 차이가 매우 적어 진단적으로 유의한 범위라고 볼 수 없다. 팔을 머리 위로 올리고 검사하는 자세가 어깨 및 팔에의 $^{18}F$-FDG섭취와 환자의 고통을 야기하게 된다는 점들을 종합하여 고려해 보았을 때, PET/CT검사 시에는 팔을 내리고 검사하는 것이 합리적이나, 환자의 상태 및 영상의 질적 측면을 고려하여 결정하여야 하겠다.

  • PDF

PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향 (The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media)

  • 안샤론;박훈희;박민수;오신현;이승재;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제13권1호
    • /
    • pp.77-81
    • /
    • 2009
  • PET/CT (Positron Emission Tomography/ Computed Tomography)의 PET은 생체의 생리, 화학적인 정보를 정량적으로 영상화할 수 있지만 해부학적인 구조를 명확히 나타내는 데에는 한계를 가지고 있어 PET에 CT를 접목시켜 해상력을 높임은 물론, CT 데이터를 감쇠보정에 이용하여 촬영시간도 단축시키고 잡음제거 측면에서도 우수함을 나타내고 있다. 또한 CT 검사 시 조영제를 사용함으로써 병변의 정확한 범위를 확인하고 정상 구조물을 구별하는데 용이하여 조영제의 사용이 증가하고 있는 추세이다. 하지만 조영제를 사용한 경우 CT 영상의 보정에 따라 PET/CT 영상에서 표준화섭취계수(Standardized Uptake Value: SUV)에 영향을 미치기 때문에 본 연구에서는 조영제 보정에 따라 표준화섭취계수(SUV)에 미치는 정도를 평가하였다. 2008년 4월에서 7월 사이에 본원에서 PET/CT검사를 시행한 환자 중 요오드 조영제에 대한 부작용이 없고 당뇨병이 없는 환자 30명을 대상으로 (남: 20, 여: 10, 연령범위: 연령범위 27세~72세, 평균나이 49.6세) 후향적 조사를 하였다. 장비는 DSTe (General Electric Healthcare, Milwaukee, MI, USA)를 사용하였다. 검사자에게 $^{18}F$-FDG 370~555 MBq를 몸무게에 따라 주사하였으며, 1시간 정도의 안정된 자세를 취한 후 검사를 시행하였다. CT촬영은 140 kV, 210 mA로 설정하였으며 CT 검사에 사용되는 조영제의 양은 환자 몸무게 1 kg당 2 cc를 주입하였다. 검사 후 최초 획득 데이터(raw data)를 이용하여 조영제 영향을 보정한 CT데이터와 보정을 하지 않은 CT데이터로 감쇠보정을 하여 영상을 얻었으며 각 영상의 간, 심장, 폐에 관심영역(Region of Interest: ROI)를 그려 SUV를 측정하여 비교하였다. SUV를 측정한 결과 조영제 보정을 한 영상의 표준화섭취계수(SUV)가 줄어듦을 알 수 있었다. 조영제에 대한 영향이 거의 없는 폐에서는 수치적인 변화가 거의 나타나지 않았으며 통계적으로도 유의하지 않았다. 비교적 혈류가 풍부한 간과 심장에서 조영제 보정으로 인한 표준화 섭취계수(SUV) 값이 수치적인 차이를 보였으나 간에서만 통계적으로 유의했다. PET/CT 검사에서 조영제의 사용으로 인하여 검사하고자 하는 부위의 대조도를 증강시켜 진단의 효율성을 높이고 있지만 이로 인하여 표준화섭취계수(SUV)의 증가가 일어난다. 따라서 조영제를 사용한 CT로 감쇠보정을 할 경우에 조영제의 영향에 대한 보정을 해주어 고해상력의 해부학적 영상뿐만 아니라 신뢰를 할 수 있는 반정량적 방법으로 진단적 가치를 더욱 높일 수 있을 것이며 다른 장기에 대해서도 추가적인 연구가 필요하다고 생각된다.

  • PDF

저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰 (Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration)

  • 김일수;김호신;류형기;강영직;박수영;김승찬;이귀원
    • 핵의학기술
    • /
    • 제20권1호
    • /
    • pp.32-36
    • /
    • 2016
  • 핵의학검사에서 $^{131}I$은 갑상선암 및 질환의 진단, 치료등 핵의학 검사에서 많이 사용되고 있다. $^{131}I$${\gamma}$선과 ${\beta}^-$선을 방출하여 검사와 치료를 할 수 있고, 높은 집적율과 신장을 통한 빠른 배설이 용이 하지만, $^{131}I$(364 keV)은 $^{99m}Tc$(140 keV)보다 고에너지이기 때문에 작업을 수행 시 조작 및 투여 과정에서 $^{99m}Tc$보다 술자의 피폭을 줄이기 위해 외부피폭 방어의 3요소인 거리, 시간, 차폐 중에 차폐에 주안점을 두어 $^{131}I$ 조작 시 차 폐체 착용 전과 후의 피폭선량의 차이를 비교하고자 한다. Apron(보통 Pb 0.5 mm) 착용 시 $^{99m}Tc$은 90%이상이 차폐가 되지만, $^{131}I$은 고에너지이기 때문에 차폐효과가 비교적 낮고, 고용량의 경우 산란선(2차) 및 제동방사선의 영향으로 오히려 더 피폭을 받을 수 있다. 하지만 저용량(74 MBq) 고에너지의 경우 이에 대한 특별한 보고나 Guide Line이 마련되어 있지 않아, $^{131}I$ 조작 시 Apron 착용 유무에 따른 술자의 피폭선량을 정량적으로 분석하고자 한다. 본원 핵의학과에서 2014년 6월부터 2014년 12월까지 7개월 동안 갑상선암 치료 및 진단을 위한 저용량$^{131}I$을 투여하기 위해 방문한 갑상선암 환자를 대상으로 준비과정부터 투여 시까지 연구기간 동안 갑상선, 가슴, 고환 3곳에 Apron 안쪽과 바깥쪽 각각 1개씩 총 6개의 TLD를 부착한 뒤 $^{131}I$검사 과정부터 투여 시 까지의 방사선 피폭선량을 측정하였다. 총 작업시간은 설명시간 3분, 분배시간 1분, 투여시간 1분으로 각각 1인당 5분이내로 설정하였다. TLD 위치설정은 일반적으로 피폭선량을 측정하는 가슴과 방사선 감수성이 높은 갑상선 및 고환으로 설정하였다. 준비과정은 $^{131}I$$2m{\ell}$ 주사기를 이용해 74MBq을 분배한 뒤 생리식염수와 희석해 $2m{\ell}$의 용량을 만들어 분배한다. $^{131}I$을 분배 후 환자에게 투여 시 컵에 물을 $100m{\ell}$ 담고 분배한 $^{131}I$을 희석하여 환자 1 m 정도 거리를 두고, 경구투여 한다. 그리고 경구투여 한 $2m{\ell}$ 주사기와 컵을 폐기하는 과정을 Apron과 TLD를 착용한 상태에서 시행하였다. Apron과 TLD는 방사선 피폭이 미치지 않는 보관실에 따로 보관하였고, 서울방사선 서비스에 의뢰하여 피폭선량을 측정하였다. 연구기간 동안 저용량 $^{131}I$ 검사 시 갑상선, 가슴, 고환 부위에 Apron 안과 밖d[착용한 TLD의 매월 누적선량을 인원수로 나눈 결과를 가지고, SPSS Version. 12.0K를 이용해 Wilcoxon Signed Rank Test를 사용하여 통계를 시행하였다. 그 결과 갑상선(p = 0.345), 가슴(p = 0.686), 고환(p = 0.715)은 모두 p > 0.05으로 유의한 차이가 없음을 알 수 있었다. 그리고 연구기간 동안의 총 누적선량의 변화를 백분율로 환산하였을 때, 갑상선 -23.5%, 가슴 -8.3%, 고환 19.0%로 나타났다. Wilcoxon Signed Rank Test를 사용한 결과 통계적으로 유의한 차이가 없는 것으로 나타났다(p > 0.05). 또한 7개월간의 누적선량으로 차폐율을 계산 했을 때 에는 Apron 안쪽과 바깥쪽의 피폭선량의 변화가 불규칙적으로 나타나는 결과를 보였다. 이 결과는 백분율로 표현 시 변화폭이 커보이지만, 누적 피폭선량이 소수점 이하이므로 큰 변화라고 보기 어렵다. 그러므로 고에너지 저용량 $^{131}I$ 투여 시 Apron을 착용유무와 상관없이 일정한 거리를 두고 최대한 빠른 시간 내에 투여를 종료하는 것이 피폭선량을 줄이는 데 도움이 될 것이다. 본 연구는 $^{131}I$ 투여시간을 1인당 각 5분 이내로 투여 할 수 있도록 제한하고, 거리를 1 m로 일정하게 하여 작업 할 수 있도록 하였으나 통계 시 N수가 적어서 비모수적인 방법으로 통계를 시행함으로써 정확한 결과를 얻기에 부족한 부분이 있었다. 또한 저용량 $^{131}I$ 투여 시 각 1인당 피폭선량을 직독식 선량으로 측정하지 못하고, TLD를 이용한 누적선량으로 측정한 결과 값이므로 전자선량계 및 포켓선량계를 이용한 측정이 이루어진다면 더 효과적인 결과를 얻을 수 있을 것으로 사료된다.

  • PDF