• Title/Summary/Keyword: Emission Source

Search Result 1,449, Processing Time 0.028 seconds

A flat thin display with RF electron generation

  • Dijk, R. Van;Vissenberg, M.C.J.M.;Zwart, S.T. De
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.927-930
    • /
    • 2004
  • We report on a new type of a flat and thin display with a secondary emission electron source. In this display device electrons are multiplied between two secondary emission plates under a high frequency electric field. This principle has a few important advantages over a field emission display: the emission comes from flat plates, which reduces the life-time problems of ion bombardment of field emitter tips. Furthermore, the electron emission is space charge limited which gives a uniform electron distribution. The electrons are extracted from the source and accelerated to a phosphor screen to generate light. Gray levels are made by pulse width modulation.

  • PDF

A Study on Mercury Emission Factor for Environmental Impact Assessment of Municipal Waste Incinerator (소각장 환경영향평가시 수은 배출 계수에 관한 연구)

  • Chun, Mee-Kyung;Park, Seok-Soon
    • Journal of Environmental Impact Assessment
    • /
    • v.7 no.2
    • /
    • pp.113-125
    • /
    • 1998
  • The amount of mercury emitted from an incinerator depends on the properties of waste, combustion condition, and control devices. Mercury concentration in air proportionates to the increase of incinerator installation. The purpose of this study is to provide a method for determination of mercury emission factor which can predict the amount of mercury emitted from each incinerator specifically. Case study was performed for N municipal waste incinerator. Based on the method presented in this paper, we obtained mercury emission factor as 1.85~1.95 g Hg/t at N Municipal Waste Incinerator and this result was regarded as reasonable when compared with existing mercury emission factor in reference cases. Fluorescent lamps turned out to be the most important source(44.4%) of mercury in municipal waste and its amount will tend to increase, while batteries become less significant. In addition, medical waste is one of the major source of mercury.

  • PDF

Simple Prediction of Odor Affection by Odor Emission Rate from a Chemical Plant (화학공장의 악취배출량으로부터 간이 악취 영향도 예측 사례)

  • 유미선;양성봉;이오근
    • Journal of Environmental Science International
    • /
    • v.11 no.4
    • /
    • pp.383-389
    • /
    • 2002
  • Odor sources of a chemical plant in Ulsan were surveyed and temperatures, humidities and flow rates of each exhaust gas were measured. The air samples collected from each source were transferred to the laboratory for sensory test and their odor concentrations were investigated. The odor emission rate of each source was estimated from the recorded results and assigned the sources expected to be needed for the odor prevention policy using the simple prediction equation of the affection by malodor to the nearest residential area. From the total odor emission rate of the examined plant and the relation table for expectable affection area it was concluded that total odor emission of this plant might be decreased for the prevention of residential complaint.

Characteristics of Ozone Precursor Emissions and POCP in the Biggest Port City in Korea

  • Song, Sang-Keun;Shon, Zang-Ho;Son, Hyun Keun
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.2
    • /
    • pp.146-157
    • /
    • 2015
  • Emissions of ozone precursors ($NO_x$ and VOCs) and photochemical ozone creation potentials (POCPs) of VOC emission sources were investigated in the largest port city (i.e., Busan), Korea during the year 2011. This analysis was performed using the Clean Air Policy Support System (CAPSS) national emission inventory provided by the National Institute of Environmental Research (NIER), Korea. For $NO_x$, the emissions from off-road mobile sources in Busan were the most dominant (e.g., $31,202ton\;yr^{-1}$), accounting for about 60% of the total $NO_x$ emissions. The emission from shipping of off-road mobile sources (e.g., $24,922ton\;yr^{-1}$) was a major contributor to their total emissions, amounting to 47% of the total $NO_x$ emissions due to the port-related activities in Busan. For VOCs, the emission source category of solvent usage was predominant (e.g., $36,062ton\;yr^{-1}$), accounting for approximately 82% of the total VOC emissions. Out of solvent usages, the emission from painting was the most dominant ($22,733ton\;yr^{-1}$), comprising 52% of the total emissions from solvent usages. The most dominant VOC species emitted from their sources in Busan was toluene, followed by xylene, butane, ethylbenzene, n-butanol, isopropyl alcohol, and propane. The major emission sources of toluene and xylene were found to be painting of coil coating and ship building, respectively. The value of POCP for the off-road mobile source (61) was the highest in ten major activity sectors of VOC emissions. Since the POCP value of ship transport of off-road mobile source (72) was also high enough to affect ozone concentration, the ship emission can play a significant role in ozone production of the port city like Busan.

Air Quality Impact Analysis of Point and Area Sources (점오염원과 면오염원의 대기환경영향 분석)

  • 김영성;손재익
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.2
    • /
    • pp.168-173
    • /
    • 1993
  • Air quality impacts of point and area sources were analyzed by using ISCST2 with wind speed and stability class combinations of SCREEN. Stack height was important in determining the impact of point sources. With the stack height reduced to 21m from 75m, the concentration in the vicinity increased several times in spite of decreasing the emission rate by half. When the emission rates were same, concentrations from an area source of 10m release height were slightly lower than those from a point source of 21m stack height at the plume centerline. Bur the area source resulted in larger area of high concentration. Concentration from the point source was high in neutral to slightly unstable conditions with strong winds in a short distance, and in stable conditions with weak winds in a long distance. Concentration from the area source decreased with distance from the source, and was high in stable conditions with weak winds.

  • PDF

Effect of TiO Addition on Morphologies and Luminescence Properties of ZnO Crystals Fabricated by Vapor Transport Method (기상이동법에 의해 제조된 ZnO 결정의 형상 및 발광 특성에 미치는 TiO 첨가의 영향)

  • Lee, Geun-Hyoung
    • Korean Journal of Materials Research
    • /
    • v.28 no.10
    • /
    • pp.590-594
    • /
    • 2018
  • ZnO micro/nanocrystals are formed by a vapor transport method. Mixtures of ZnO and TiO powders are used as the source materials. The TiO powder acts as a reducing agent to reduce the ZnO to Zn and plays an important role in the formation of ZnO micro/nanocrystals. The vapor transport process is carried out in air at atmospheric pressure. When the weight ratios of TiO to ZnO in the source material are lower than 1:2, no ZnO micro/nanocrystals are formed. However, when the ratios of TiO to ZnO in the source material are greater than 1:1, the ZnO crystals with one-dimensional wire morphology are formed. In the room temperature cathodoluminescence spectra of all the products, a strong ultraviolet emission centered at 380 nm is observed. As the ratio of TiO to ZnO in the source material increases from 1:2 to 1:1, the intensity ratio of ultraviolet to visible emission increases, suggesting that the crystallinity of the ZnO crystals is improved. Only the ultraviolet emission is observed for the ZnO crystals prepared using the source material with a TiO/ZnO ratio of 2:1.

VOCs Emission Characteristics and Mass Contribution Analysis at Wanju Industrial Area (완주지역의 VOCs 배출특성에 따른 공단지역과 일반지역의 기여도 분석)

  • Kim, Deug-Soo;Yang, Go-Soo;Park, Bi-O
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.5
    • /
    • pp.562-573
    • /
    • 2008
  • Concentrations of volatile organic compounds (VOCs) measured from the local industrial sources in Wanju industrial complex during June $2007{\sim}January$ 2008. The samples were collected from the primary sources (6 emission points) in 4 major factories in Wanju industrial complex as well as two general sources in Wanju County to elucidate the abundances of speciated VOCs and their spacial and temporal distributions depending on source bases. Industrial sources are as follows; fabricated metal manufacture, motor vehicle manufacture, rubber and plastic manufacture, and chemical manufacture factories. Two general source samples were collected from gasoline gas station and dry cleaning shop in urban area. In order to understand the near source influence at receptor, samples from the two receptor sites (one is at center of the industrial complex and the other site is at distance residential area downwind from the center) were collected with sample canister, and analyzed by using GC/MSD. The concentrations from different sources were compared and discussed. The mass contributions of the speciated VOCs to total VOCs measured from industrial sources and ambient ai r at two receptors were presented and discussed.

Development of the vac Source Profile using Collinearity Test in the Yeosu Petrochemical Complex (여수석유화학산단의 공선성 시험을 이용한 VOC 오염원 분류표 개발)

  • Jeon Jun-Min;Hur Dang;Hwang In Jo;Kim Dong-Sul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.3
    • /
    • pp.315-327
    • /
    • 2005
  • The total of 35 target VOCs (volatile organic compounds), which were included in the TO-14, was selected to develop a VOCs' source profile matrix of the Yeosu Petrochemical Complex and to test its collinearity by singular value decomposition(SVD) technique. The VOCs collected in canisters were sampled from 12 different sources such as 8 direct emission sources (refinery, painting, wastewater treatment plant, incinerator, petrochemical processing, oil storage, fertilizer plant, and iron mill) and 4 general area sources (gasoline vapor emission, graphic art activity, vehicle emission, and asphalt paving activity) in this study area, and then those samples were analyzed by GC/MS. Initially the resulting raw data for each profile were scaled and normalized through several data treatment steps, and then specific VOCs showing major weight fractions were intensively reviewed and compared by introducing many other related studies. Next, all of the source profiles were tested in terms of degree of collinearity by SVD technique. The study finally could provide a proper VOCs' source profile in the study area, which can give opportunities to apply various receptor models properly including chemical mass balance (CMB).

Field Emission source를 이용한 SEMAP(Scanning Electron Microscopy with Polarization Anlysis) 개발

  • Lee, Sang-Seon;Bae, Mun-Seop;Kim, Won-Dong;Hwang, Chan-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.346-346
    • /
    • 2011
  • 최근 들어 나노스케일에서의 자구체(magnetic domain)에 대한 연구가 매우 활발하게 진행되고 있다. 현재 국내에서 자성 나노구조에 대한 연구가 매우 활발하게 진행 되고 있는 반면에 나노자성이미지를 연구 할 수 있는 장비는 매우 미비한 상황이다. 이러한 자성 이미징을 연구하는데 있어 가장 핵심 적인 장비가 SEMPA(Scanning Electron Microscopy with Polarization Analysis)이다. 국내에서 자성나노구조의 자화와 형상을 동시에 측정 할 수 있는 장비는 한국표준과학연구원에서 개발된 W-filament source를 사용한 SEMPA가 유일하다. 일반적으로 SEM의 경우 고에너지 빔의 전자 빔을 주사 시키고 이때 발생되는 이차 전자의 수를 2차원상의 영역에 따라 달라지는 비로 형상을 측정 하게 된다. 이때 전자의 수 뿐만 아니라 이들의 spin polarization을 측정 할 수 있다면 형상뿐 만 아니라 표면에서의 스핀 상태를 동시에 측정할 수 있게 된다. 기개발된 W-filament source를 이용한 SEMPA는 field emission source에 비하여 전자빔의 세기가 약하며 이차 전자의 수도 적어 spin polarization 감도가 현저히 떨어진다. 또한 초고진공(1x10-10torr)에서 사용할 수 없어 측정시료의 contamination을 방지 할 수 없다. 이러한 문제점들을 보안하기 위하여 field emission source를 이용한 FE-SEMPA를 개발 중이다. 본 연구에서는 설계 및 전산시늉등의 연구결과와 진행사항을 발표하고자 한다. 아울러 W-filament를 사용한 SEMPA의 연구결과에 대한 논의를 할 예정이다.

  • PDF

A Study of the Development of PC-Based Source Location System using Acoustic Emission Technique (음향방출기법을 이용한 PC기반 위치표정시스템 개발에 관한 연구)

  • Lee, M.R.;Lee, J.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.3
    • /
    • pp.205-211
    • /
    • 2003
  • Acoustic emission (AE) technique has been applied to not only mechanical property testing but also on-line monitoring of the el)tire structure or a limit zone only. Although several AE devices have already been developed for the on-line monitoring, the price of these systems is very high and it is difficult for the field to apply yet. In this study, wc developed a specially designed PC-based source location system using the A/D board. The source location technique is very important to identify the source, such as crack, leak detection. However, since the AE waveforms obtained from transducers are very difficult to distinguish the defect signals, therefore, it is necessary to consider the signal analyses of the transient waveform. Wavelet Transform (WT) is a powerful tool for processing transient signals with temporally varying spectra that helps to resolve high and low frequency transients components effectively In this study, the analyses of the AE signals are presented by employing the WT analyses. AE results are compared the PC-based source location system using A/D board with the commercial AE system.