• Title/Summary/Keyword: Emission Image

Search Result 523, Processing Time 0.051 seconds

High-Performance Compton SPECT Using Both Photoelectric and Compton Scattering Events

  • Lee, Taewoong;Kim, Younghak;Lee, Wonho
    • Journal of the Korean Physical Society
    • /
    • v.73 no.9
    • /
    • pp.1393-1398
    • /
    • 2018
  • In conventional single-photon emission computed tomography (SPECT), only the photoelectric events in the detectors are used for image reconstruction. However, if the $^{131}I$ isotope, which emits high-energy radiations (364, 637, and 723 keV), is used in nuclear medicine, both photoelectric and Compton scattering events can be used for image reconstruction. The purpose of our work is to perform simulations for Compton SPECT by using the Geant4 application for tomographic emission (GATE). The performance of Compton SPECT is evaluated and compared with that of conventional SPECT. The Compton SPECT unit has an area of $12cm{\times}12cm$ with four gantry heads. Each head is composed of a 2-cm tungsten collimator and a $40{\times}40$ array of CdZnTe (CZT) crystals with a $3{\times}3mm^2$ area and a 6-mm thickness. Compton SPECT can use not only the photoelectric effect but also the Compton scattering effect for image reconstruction. The correct sequential order of the interactions used for image reconstruction is determined using the angular resolution measurement (ARM) method and the energies deposited in each detector. In all the results of simulations using spherical volume sources of various diameters, the reconstructed images of Compton SPECT show higher signal-to-noise ratios (SNRs) without degradation of the image resolution when compared to those of conventional SPECT because the effective count for image reconstruction is higher. For a Derenzo-like phantom, the reconstructed images for different modalities are compared by visual inspection and by using their projected histograms in the X-direction of the reconstructed images.

Electromagnetic Susceptibilty design of High-Speed Image Signal Processing Unit for Small Infrared Image Homing sensor (적외선 영상 호밍센서 고속 영상신호처리기의 전자기파 내성 설계)

  • Kim, Hong-Rak;Park, Jin-Ho;Kim, Kyoung-Il;Jeon, Hyo-won;Shin, Jung-Sub
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.2
    • /
    • pp.27-33
    • /
    • 2022
  • The small infrared image homing sensor is the eye of a guided weapon that has an infrared image sensor that identifies a target on the ground through day and night infrared image processing and searches, detects, and tracks the target. Inside the guided weapon since the power supply and communication line are used together with various components, the part against electromagnetic wave interference is very important. In particular, the effect of CE (Conducted Emission) through the power and communication lines connected by cables is very important. Through this method, it is possible to directly affect other components of the guided weapon. In this paper, the EMI filter and cable design for avoiding electromagnetic interference to the power input through the cable and the communication line are described. Also, the designed EMI filter is manufactured After the CE102 test of MIL-STD-461G, design satisfaction will be explained.

Leakage Monitoring of Control Valves for Nuclear Power Plants Using Multi-measuring (Multi-measuring기법을 이용한 원전 제어밸브의 누설진단)

  • Kim, Sung-Young;Kim, Young-Bum;Kim, Bong-Ho;Lee, Sang-Guk
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3458-3463
    • /
    • 2007
  • Leakage would happen because of the damage of high temperature and high-pressure valve in nuclear power plant. condition based prevention maintenance is essential by using the suitable method based on local condition. Energy loss prevention can prevent from an accurate test, Local actually and ability. The methods of test for high energy fluid leakage at present are analysis of ${\Delta}$T, AE(Acoustic Emission) analysis, and thermal image. The result for test of AC (Main steam) system in YNG 2 Unit reveals that the AE occurred clearly in leakage situation, but thermal image didn't occur. It is identified that leakage is occurred when the orifice located front and back of valve operates. It shows that making a impatient judgment by using the single method if it is leakage is containing uncertainty. So I think that using the Multi-Measuring method is more sound judgment than Single-Measuring method.

  • PDF

Study on the Multi-measuring Method for Evaluation of Internal Leak of Power Plant Valve (발전용 밸브누설 평가를 위한 다중계측 연구)

  • Lee, S.G.;Park, S.K.;Park, J.H.;Kim, K.H.;Kim, Y.B.
    • Journal of Power System Engineering
    • /
    • v.11 no.3
    • /
    • pp.35-40
    • /
    • 2007
  • Leak would happen because of the damage of high temperature and high-pressure valve in nuclear power plant. condition based prevention maintenance is essential by using the suitable method based on local condition. Energy loss prevention can prevent from an accurate test, Local actually and ability. The methods of test for high energy fluid leak at present are analysis of ${\Delta}T$, AE(Acoustic Emission) analysis, and thermal image. The result for test of secondary system in nuclear power plant Unit reveals that the AE occurred clearly in leakage situation, but thermal image didn't occur. It is identified that leak is occurred when the orifice located front and back of valve operates. It shows that making a impatient judgment by using the single method if it is leakage is containing uncertainty. So we think that using the Multi-Measuring method is more sound judgment than single-measuring method.

  • PDF

Experimental study of noise level optimization in brain single-photon emission computed tomography images using non-local means approach with various reconstruction methods

  • Seong-Hyeon Kang;Seungwan Lee;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1527-1532
    • /
    • 2023
  • The noise reduction algorithm using the non-local means (NLM) approach is very efficient in nuclear medicine imaging. In this study, the applicability of the NLM noise reduction algorithm in single-photon emission computed tomography (SPECT) images with a brain phantom and the optimization of the NLM algorithm by changing the smoothing factors according to various reconstruction methods are investigated. Brain phantom images were reconstructed using filtered back projection (FBP) and ordered subset expectation maximization (OSEM). The smoothing factor of the NLM noise reduction algorithm determined the optimal coefficient of variation (COV) and contrast-to-noise ratio (CNR) results at a value of 0.020 in the FBP and OSEM reconstruction methods. We confirmed that the FBP- and OSEM-based SPECT images using the algorithm applied with the optimal smoothing factor improved the COV and CNR by 66.94% and 8.00% on average, respectively, compared to those of the original image. In conclusion, an optimized smoothing factor was derived from the NLM approach-based algorithm in brain SPECT images and may be applicable to various nuclear medicine imaging techniques in the future.

A study on the temporal bright image sticking problem in AC PDP

  • Ha, Chang-Hoon;Jeong, Dong-Chul;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.113-116
    • /
    • 2004
  • In this study, the causes of temporal bright image sticking problem in an AC PDP were investigated. The temporal bright image sticking problem in an ac PDP is observed to be a relatively lower luminance following several minutes on-time at a high gray level compared to that of the ordinary turned-on image area. We focused on the detailed causes of image sticking, which are directly related with the visible emission such as the changes in the characteristics of phosphor, MgO surface and gas dynamics. The experimental results show that the thermal quenching of phosphor and temperature-dependent discharge characteristics change cause the image sticking problem.

  • PDF

Far-ultraviolet Observations of the Comet C/2001 Q4 (NEAT)

  • Lim, Yeo-Myeong;Min, Kyoung-Wook;Seon, K.I.;Han, W.;Edelstein, J.
    • Bulletin of the Korean Space Science Society
    • /
    • 2011.04a
    • /
    • pp.20.1-20.1
    • /
    • 2011
  • We present the results of far-ultraviolet (FUV) observations of comet C/2001 Q4 (NEAT) obtained with Far-ultraviolet Imaging Spectrograph (FIMS) on board the Korean microsatellite STSAT-1, which operated at an altitude of 700 km in a sun-synchronous orbit. FIMS is a dual-channel imaging spectrograph (S channel 900-1150 ${\AA}$, L channel 1350-1750 ${\AA}$, ${\lambda}/{\Box}{\lambda}$ ~ 550) with large image fields of view (S: $4^{\circ}.0{\times}4'.6$, L: $7^{\circ}.5{\times}4'.3$, angular resolution 5'-10') optimized for the observation of diffuse emission of astrophysical radiation. Comet C/2001 Q4 (NEAT) was observed with a scanning survey mode when it was located around the perihelion between 8 and 15 May 2004. Several important emission lines were detected including S I (1425, 1474 ${\AA}$), C I (1561, 1657 ${\AA}$) and several emission lines of CO $A1{\cap}-X1{\sum}+$ system in the L channel. We estimated QCO = ($2.58\;{\pm}\;0.64)\;{\times}\;1028$ s-1 from the production rate of CO 1510 ${\AA}$. We obtained L-channel image which have map size of $5^{\circ}{\times}5^{\circ}$. The image was constructed for the wavelength band of L-channel (1350-1750 ${\AA}$).We also obtained radial profile of S I, C I, CO with line fitting from central coma.

  • PDF

FUV observation of the comet C/2001 Q4 (NEAT) with FIMS

  • Lim, Yeo-Myeong;Min, Kyoung Wook;Feldman, Paul D.;Han, Wonyong;Edelstein, Jerry
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.107.1-107.1
    • /
    • 2012
  • We present the results of far-ultraviolet (FUV) observations of comet C/2001 Q4 (NEAT) obtained with Far-ultraviolet Imaging Spectrograph (FIMS) on board the Korean microsatellite STSAT-1, which operated at an altitude of 700 km in a sun-synchronous orbit. FIMS is a dual-channel imaging spectrograph (S channel 900-1150 ${\AA}$, L channel 1350-1750 ${\AA}$, ${\lambda}/{\Delta}{\lambda}$ ~ 550) with large image fields of view (S: $4^{\circ}.0{\times}4^{\prime}.6$, L: $7^{\circ}.5{\times}4^{\prime}.3$, angular resolution 5'-10') optimized for the observation of diffuse emission of astrophysical radiation. Comet C/2001 Q4 (NEAT) was observed with a scanning survey mode when it was located around the perihelion between 8 and 15 May 2004. Several important emission lines were detected including S I (1425, 1474 ${\AA}$), C I (1561, 1657 ${\AA}$) and several emission lines of CO $A^1{\Pi}-X^1{\Sigma}^+$ system in the L channel. Production rates of the notable molecules, such as C I, S I and CO, were estimated from the photon fluxes of these spectral lines and compared with previous observations. We compare the flux and the production rates in the radius of $3{\times}10^5$ km with $20{\times}10^5$ km from the central coma. We obtained L-channel image which have map size $5^{\circ}{\times}5^{\circ}$ The image was constructed for the wavelength band of L-channel (1350 - 1710 ${\AA}$. We also present the radial profiles of S I, C I, CO obtained from the spectral images of the central coma. The radial profiles of $2{\times}10^6$ km region are compared with the Haser model.

  • PDF