• Title/Summary/Keyword: Emergency monitoring

Search Result 469, Processing Time 0.024 seconds

Advances in gamma radiation detection systems for emergency radiation monitoring

  • Kumar, K.A. Pradeep;Sundaram, G.A. Shanmugha;Sharma, B.K.;Venkatesh, S.;Thiruvengadathan, R.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2151-2161
    • /
    • 2020
  • The study presents a review of research advancements in the field of gamma radiation detection systems for emergency radiation monitoring, particularly two major sub-systems namely (i) the radiation detector and (ii) the detection platform - air-borne and ground-based. The dynamics and functional characteristics of modern radiation detector active materials are summarized and discussed. The capabilities of both ground-based and aerial vehicle platforms employed in gamma radiation monitoring are deliberated in depth.

Development of an Integrated Control and Monitoring System for Emergency Power Generators (비상발전기 통합제어 및 감시시스템 개발)

  • 진강규;류길수;윤지근;유성호;김재환
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.192-196
    • /
    • 2001
  • These days, most of electric power facilities need high stability. Therefore integrated system has been required to monitor and control electronic power distribution system in fields at all times when the interruption of electric power has occurred. To construct this system, unit that convert and process the input signal from fields needed. And for control and monitoring from remote place MMI software is required. Lastly network equipments are required for real-time communications. So, in this paper, units for control and monitoring of emergency power generator and for electric power monitoring in normal electric power and interruption of electric power are developed. Also integrated remote system for monitoring in remote is developed.

  • PDF

A New Emergency-Handling Mechanism based on IEEE 802.15.4 for Health-Monitoring Applications

  • Ranjit, Jay Shree;Pudasaini, Subodh;Shin, Seokjoo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.2
    • /
    • pp.406-423
    • /
    • 2014
  • The recent advances in wireless communication systems and semiconductor technologies are paving the way for new applications over wireless sensor networks. Health-monitoring application (HMA) is one such emerging technology that is focused on sensing and reporting human vital signs through the communication network comprising sensor devices in the vicinity of the human body. The sensed vital signs can be divided into two categories based on the importance and the frequency of occurrence: occasional emergency signs and regular normal signs. The occasional emergency signs are critical, so they have to be delivered by the specified deadlines, whereas the regular normal signs are non-critical and are only required to be delivered with best effort. Handling the occasional emergency sign is one of the most important attributes in HMA because a human life may depend on correct handling of the situation. That is why the underlying network protocol suite for HMA should ensure that the emergency signs will be reported in a timely manner. However, HMA based on IEEE 802.15.4 might not be able to do so owing to the lack of an appropriate emergency-handling mechanism. Hence, in this paper, we propose a new emergency-handling mechanism to reduce the emergency reporting delay in IEEE 802.15.4 through the modified superframe structure. A fraction of an inactive period is modified into three new periods called the emergency reporting period, emergency beacon period, and emergency transmission period, which are used opportunistically only for immediate emergency reporting and reliable data transmission. Extensive simulation is performed to evaluate the performance of the proposed scheme. The results reveal that the proposed scheme achieves improved latency and higher emergency packets delivery ratio compared with the conventional IEEE 802.15.4 MAC.

Control Scheme of Emergency Power Supply for Elevator Emergency Call System (승강기의 비상 통화장치용 비상 전원장치의 충·방전 제어회로)

  • Park, Noh-Sik;Lee, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.8
    • /
    • pp.40-48
    • /
    • 2015
  • In this paper, battery charging and discharging circuit with a single voltage power supply is proposed. The proposed circuit has the separated current path and charging-monitoring sequence control scheme. In the charging sequence, the proposed 2-level comparator combined with control signal of the micro-processor can control the constant charging current to protect the over current of the battery. Furthermore, the proposed circuit uses a periodic main power switch control to detect the discharging characteristics to estimate the approximated battery life-time. In the experiments, the proposed emergency power supply for emergency call system has 89% efficiency with 98% power factor. And the proposed sequence control scheme is well operated in the designed emergency power system.

The effects of monitoring of the pressures applied on the defibrillator paddles - A manikin study - (제세동 패들에 가해지는 압력의 모니터링 효과)

  • Park, Si-Eun;Shin, Dong-Min
    • The Korean Journal of Emergency Medical Services
    • /
    • v.16 no.3
    • /
    • pp.9-18
    • /
    • 2012
  • Purpose : The purpose of this study was to determine the changes that occur due to the real-time monitoring of paddle pressures which has an important influence on the defibrillation success rate in defibrillation treatment known as the only treatment for cardiac arrest patients with VF. Methods : 40 people participated in the cardiac arrest simulation training and played the role of the defibrillation operator. Investigators measured the pressure of paddle while defibrillating by using instrument which was developed by the investigator. Results : Through real-time monitoring of the paddle pressures of defibrillator by indicator, the front sternum paddle showed a 77.5% success rate and the apex paddle showed a 40% success rate. While the values without monitoring the paddle pressures, the front sternum paddle showed a 51% success rate and the apex paddle showed a 20% success rate. These experiment revealed statistically significant(p <.001) low success rate. Conclusion : The method of monitoring the paddle pressures during defibrillation showed that the paddle can be precisely gripped. The success rate of paddle pressures is significantly correlated with height, weight and grip strength.

Effect of ETCO2 monitoring of poisoning patients with decreased mental state in ED (의식 저하로 내원한 중독 환자들에 대한 호기말 이산화탄소분압 관찰의 효과)

  • Kwon, Yong Hee;So, Byung Hak;Jeong, Won Jung
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.19 no.1
    • /
    • pp.44-50
    • /
    • 2021
  • Purpose: This study aimed to analyse the effect of End-Tidal Carbon Dioxide (ETCO2) monitoring on patients who had been poisoned and presented in the emergency department with decreased consciousness. Methods: The data of patients over 18 years old presenting with poisoning from 2016 to 2020 was collected from the emergency department. We retrospectively analyzed their medical records, and defined patients with a Glasgow Coma Scale (GCS) score of 9 or less as having decreased consciousness. We divided the patients into two groups, one with ETCO2 monitoring and the other without, and the difference between the two groups was compared. Results: 168 patients participated in this study and 83 (49.4%) of them belonged to the ETCO2 monitoring group. In this group, the interval between arterial blood tests was statistically significantly longer and the rate of intubation was lower. In addition, in the monitoring group, the incidence of pneumonia and the rate of poor prognosis was not significantly higher. Conclusion: Although ETCO2 monitoring does not directly affect the prognosis of poisoned patients with decreased consciousness, it should be actively done as it can help to adequately treat patients while avoiding invasive techniques or unnecessary intubation.

An Integrated Emergency Call System based on Public Switched Telephone Network for Elevators

  • Lee, Guisun;Ryu, Hyunmi;Park, Sunggon;Cho, Sungguk;Jeon, Byungkook
    • International journal of advanced smart convergence
    • /
    • v.8 no.3
    • /
    • pp.69-77
    • /
    • 2019
  • Today, most of elevators have an emergency call facility for emergency situations. However, if the network installed in the elevator is also out of power, it cannot be used for the elevator remote monitoring and management. So, we develop an integrated and unified emergency call system, which can transmit not only telephone call but also data signals using PSTN(Public Switched Telephone Network) in order to remote monitoring and management of elevators, even though a power outage occurs. The proposed integrated emergency call system to process multiple data such as voice and operational information is a multi-channel board system which is composed of an emergency phone signal processing module and an operational information processing module in the control box of elevator. In addition, the RMS(remote management server) systems based on the Web consist of a dial-up server and a remote monitoring server where manages the elevator's operating information, status records, and operational faults received via the proposed integrated and unified emergency call system in real time. So even if there's a catastrophic emergency, the proposed RMS systems shall ensure and maintain the safety of passengers inside the elevator. Also, remote control of the elevator by this system should be more efficient and secure. In near future, all elevator emergency call system need to support multifunctional capabilities to transmit operational data as well as phone calls for the safety of passengers. In addition, for safer elevators, it is necessary to improve them more efficiently by combining them with high-tech technologies such as the Internet of Things and artificial intelligence.

Optimal Monitoring Intervals and MDA Requirements for Routine Individual Monitoring of Occupational Intakes Based on the ICRP OIR

  • Ha, Wi-Ho;Kwon, Tae-Eun;Jin, Young Woo
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.2
    • /
    • pp.88-94
    • /
    • 2020
  • Background: The International Commission on Radiological Protection (ICRP) has recently published report series on the occupational intakes of radionuclides (OIR) for internal dosimetry of radiation workers. In this study, the optimized monitoring program including the monitoring interval and the minimum detectable activity (MDA) of major radionuclides was suggested to perform the routine individual monitoring of internal exposure based on the ICRP OIR. Materials and Methods: The derived recording levels and the critical monitoring quantities were reviewed from international standards or guidelines by the International Atomic Energy Agency (IAEA), the International Organization for Standardization (ISO), and the European Radiation Dosimetry Group (EURADOS). The OIR data viewer provided by ICRP was used to evaluate the monitoring intervals and the MDA, which are derived from the reference bioassay functions and the dose coefficients. Results and Discussion: The optimal monitoring intervals were determined taking account of two requirement conditions on the potential intake underestimation and the MDA values. The MDA requirement values of the selected radionuclides were calculated based on the committed effective dose from 0.1 mSv to 5 mSv. The optimized routine individual monitoring program was suggested including the optimal monitoring intervals and the MDA requirements. The optimal MDA values were evaluated based on the committed effective dose of 0.1 mSv. However, the MDA can be adjusted considering the practical operation of the routine individual monitoring program in the nuclear facilities. Conclusion: The monitoring intervals and the MDA as crucial factors for the routine monitoring were described to suggest the optimized routine individual monitoring program of the occupational intakes. Further study on the alpha/beta-emitting radionuclides as well as short lived gamma-emitting nuclides will be necessary in the future.

Emergency Environmental Monitoring for the Decision-Aiding on Public Protective Actions during a Nuclear Accident (원자력 사고시 주민 보호조치 결정 지원을 위한 비상 환경감시)

  • Choi, Yong-Ho;Choi, Geun-Sik;Han, Moon-Hee;Lee, Han-Soo;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.3
    • /
    • pp.131-148
    • /
    • 2005
  • In a nuclear emergency, protective actions for the public should be taken in time. It is internationally proposed that generic intervention levels (GILs) and generic action levels, determined based on cost-benefit analyses, be used as the decision criteria for protective actions. Operational intervention levels (OILs) are directly or easily measurable quantities corresponding to these generic levels. To assess the necessity of protective actions in a nuclear emergency, it is important that the environmental monitoring data required for applying and revising OILs should be promptly produced. It is discussed what and how to do for this task in the course of the emergency response. For an emergency environmental monitoring to be performed effectively, a thorough preparedness has to be made including maintenance of the organization and equipments, establishment of various procedure manuals, development of a supporting computer system and periodical training and exercises. It is pointed out that Korean legal provisions concerning GILs and OILs need to be amended or newly established.