• Title/Summary/Keyword: Emergency generator

Search Result 198, Processing Time 0.028 seconds

A Study of Analysis for Small Buried Type Permanent Magnet Synchronous Generator Considering Armature Resistance Effect (전기자 저항의 영향을 고려한 소형 영구자석 매입형 동기발전기 정상상태 특성 해석 연구)

  • Hong, Sun-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.380-383
    • /
    • 2012
  • Small permanent magnet generator can be used not only as an emergency power source but also an exciting power source of generator for small generating systems because it does not need the external exciting power source. Especially the air-gap flux density of the buried PM synchronous generator can be increased more than that of the permanent magnet. In this study, the analysis of the small buried type PM synchronous generator is performed. From the phasor diagram considering armature resistance for exact analysis, analytic equations are induced and the efficiency, developed voltage, load current are calculated. The experimental results are compared with the calculated results for the appropriateness.

An Experimental Study upon Modeling and Control of Coupled Engine and Generator System (엔진-발전기 시스템 모델링 및 제어특성에 관한 실험적 연구)

  • 송승호;정세종;오정훈;함윤영;최용각;이광희
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.5
    • /
    • pp.163-169
    • /
    • 2003
  • Modeling of engine-generator system and its control responses are investigated using high performance generator controller. The nonlinear engine is modeled using mean torque production model based on experimental engine map. In case of diesel engine. the amount of injected fief is decided by engine controller depending on the APS(Acceleration Position Sensor) value. An electromechanical generator model contains electrical circuits and moment of inertia. The generator controller maximizes the performance of generator using decoupling and linearized current feedback control. The generator control system consists of 3-phase IGBT inverter and controller board based on 32 bit floating point DSP. Field oriented control algorithm with digital current feedback control at 10kHz sampling enabled high performance torque and speed control of induction machine. Not only the steady state but also the transient state responses can be evaluated through a batch test of the engine generator system. Developed engine and generator modeling and control can be utilized in various applications such as Series Hybrid Electric Vehicle(SHEV), engine-generator for emergency, and other hybrid generation systems.

A Study on the Power Plant Application of Engine Condition Diagnosis Technology for Diesel Generator (디젤발전기 엔진 상태 진단 기술의 발전소 적용 연구)

  • Choi, Kwang-Hee;Lee, Sang-Guk
    • Journal of Power System Engineering
    • /
    • v.17 no.4
    • /
    • pp.17-22
    • /
    • 2013
  • Diesel generator of nuclear power plant has a role for supply of emergency electric power to protect reactor core system in event of loss of off-site power supply. Therefore diesel generator should be tested periodically to verify the function that can supply specified frequency and voltage at design power level within limited time. For this purpose, appropriate maintenances in case that abnormal conditions were found are required in allowed time. In this paper, results of development of engine condition diagnosis technology and study on power plant of its technology for diesel generator are described.

Analysis of the Virtual Power Plant Model Based on the Use of Emergency Generators in South Korea

  • Chung, Beom Jin;Kim, Chang Seob;Son, Sung-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.38-46
    • /
    • 2016
  • This study analyzes the economic efficiency of the virtual power plant (VPP) model that aims to integrate a number of emergency generators installed at the consumer end and operate them as a single power plant. Several factors such as the demand response benefits from VPP operation and costs incurred for converting emergency generators into VPP are considered to assess the economic efficiency of the proposed VPP model. Scenarios for yearly VPP conversion are prepared based on the installed capacities of the emergency generators distributed in South Korea, while the costs and benefits are calculated from the viewpoints of participants and power companies in accordance with California Test Methods. Furthermore, a sensitivity analysis is conducted on the cost factors among those affecting the economic efficiency of VPP business because these two factors have a great impact on benefits.

Study on the Emergency Protection System of Liquid Rocket Engine (액체로켓엔진 비상보호시스템 연구)

  • Kim, Seung-Han;Han, Yeoung-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.97-103
    • /
    • 2011
  • This paper describes the main considerations for the development of engine emergency protection system and applications to preliminary engine development tests. Emergency protection system performed its role without failure to shutdown test very quickly for the prevention of development of malfunctioning of test articles, which protected test articles and test facility in all abnormal situation occurred during preliminary engine development test program. This results will be used for the development of engine emergency protection system.

  • PDF

Study on the Liquid Rocket Engine Health Monitoring and Emergency Protection System (액체로켓엔진 상태진단/비상보호시스템 연구)

  • Kim, Seung-Han;Nam, Chang-Ho;Seol, Woo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.178-182
    • /
    • 2007
  • This paper reviews on the LRE health monitoring and emergency protection system to protect test object engine system and engine test facility, in case of various fault occurrence at LRE testing. General composition and major technical consideration of LRE health monitoring system and emergency protection system are reviewed. Moreover, some application of LRE health monitoring/emergency protection system to development test of major LRE component such as turbopump testing, gas generator and combustion chamber test are reviewed.

  • PDF

Operating Vibration Reduction Effect Evaluation of EDG at the NPP Site (원자력발전소 비상디젤발전기의 가동중 진동저감 효과)

  • Kim, Min-Kyu;Choun, Young-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.111-118
    • /
    • 2006
  • The Emergency Diesel Generator(EDG) is a very important piece of equipment for the safety of a Nuclear Power Plant(NPP). In this study, the operating vibration or three kinds or EDG system was measured. The target EDG systems art Yonggwang 5 unit, Ulchin 2 unit and Ulchin 3 unit. The Yonggwang 5 and Ulchin 3 unit EDG system is the same type but the foundation systems are different. One is an anchor bolt type and the other is a spring and viscous-damper type. The purpose of this measurement is for a verification of the vibration isolation effect according to the foundation system. As a result. it can he said that the spring and viscous damper system of the EDG performed well for the vibration isolation.

  • PDF

Retrofit of Safety Class 1E Emergency Diesel Generator in Nuclear Power Plant (원자력발전소 안전 등급 1E 비상디젤발전기 리트로피트 (Retrofit))

  • Kim, Chul-Hyo;Chang, Choong-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.689-690
    • /
    • 2015
  • 국내 최초 원전인 고리1호기는 지난 2007년 30년의 운전수명을 마친 뒤 정부의 안전점검을 거쳐 10년간 연장운전에 들어갔다. 이 과정에서 원전의 비상 전원 계통 신뢰성 확보를 위해 설계수명을 초과한 35년 된 노후 비상디젤발전기(Emergency Diesel Generator, 이하 EDG)를 지난 2013년 4월부터 9월까지 약 6개월에 걸쳐 교체하게 되었으며, 국내 원전 EDG 총 42대 중 18대가 20년 넘게 운영되고 있고, 2025년까지 고리 1호기를 후속으로 월성1호기, 고리2호기, 고리3호기, 고리4호기, 한빛1호기 순으로 40년 승인된 운전 인허가 기간이 만료된다.[1]. 본 연구에서, Class 1E EDG 교체 시 신규 EDG 설계기준, 용량결정, 해석 및 평가에 대한 기술적 방법들을 고리1호기의 사례를 통해 고찰하였다.

  • PDF

On Hunting Protected Circuit at the Inflow about Load direction Harmonics of a Small Size the Generator (소형 발전기의 부하측 고조파 유입시 HUNTING 방지회로)

  • Bae, Jong-Il;Park, Byeong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2668-2670
    • /
    • 2002
  • The generators of a small size below 100Kw are often used as power suppliers for emergency only in most domestic telecommunication companies. Serious twisted waves occur due to the inflow of harmonies from the generator into a S-type rectifier. And the increasing by stages of load upon the rectifier end up a stoppage of power supply during the serious hunting, which makes it difficult to supply power securely on the other part as well as that of communications. In case of long time of power failure the generators of a small size will be essential because the battery for emergency has a limit in capacity. Therefore it is necessary to solve the problems concerning the generators. This study is focused on the identifying and solving the problem including use of SCR elements connected to the generators.

  • PDF