• Title/Summary/Keyword: Emergency gate

Search Result 17, Processing Time 0.024 seconds

Analysis of Small reservoir system by Flood control ability augmentation (치수능력 증대에 따른 저수지시스템 분석)

  • Park Ki-Bum;Lee Soon-Tak
    • Journal of Environmental Science International
    • /
    • v.14 no.11
    • /
    • pp.995-1004
    • /
    • 2005
  • As a research establish reservoir safety operation for small dam systems. This study presents hydrologic analysis conducted in the Duckdong and Bomun dam watershed based on various rainfall data and increase inflow. Especially the Duckdong dam without flood control feature are widely exposed to the risk of flooding, thus it is constructed emergency gate at present. In this study reservoir routing program was simulation for basin runoff estimating using HEC-HMS model, the model simulation the reservoir condition of emergency Sate with and without. At the reservoir analysis results is the Duckdong dam average storage decrease $20\%$ with emergency gate than without emergency gate. Also, the Bomun dam is not affected by the Duckdong flood control augmentation.

Evaluation of Flood Control Capacity for Seongju Dam against Extreme Floods (이상강우에 대비한 성주댐의 홍수조절 능력 분석)

  • 권순국;한건연;서승덕;최혁준
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.6
    • /
    • pp.109-118
    • /
    • 2003
  • As a fundamental research to establish a safety operation plan for irrigation dams, this study presents hydrologic analysis conducted in Sungju Dam watershed based on various rainfall data. Especially those reservoirs without flood control feature are widely exposed to the risk of flooding, a safe and optimized operation program need to be improved against arbitrary flooding. In this study, reservoir routing program was developed and simulated for reservoir runoff estimation using WMS hydrology model. The model simulated the variations of reservoir elevation under the condition of open or closed emergency gate. In case of closed emergency gate, water surface elevation was given as 193.15 m, and this value exceeds the dam crest height by 1.65 m. When the emergency gate is open, the increment of water surface elevation is given as 192.01 m, and this value exceeds dam crest height by 0.57 m. As an alternative plan, dam height increase can be considered for flood control under the PMP (Probable Maximum Precipitation) condition. Since the dam size is relatively small compare to the watershed area, sound protection can be expected from the latter option rather than emergency gate installation.

A Hydrological Analysis on the Gate Operation Rule of Dams in Han River Basin (한강유역(漢江流域) 댐군(群)의 수문조작방안(水門操作方案)에 관한 수문(水文) 해석(解析))

  • Lee, Won Hwan;Cho, Won Cheol;Lee, Jae Joon;Heo, Jun Haeng
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.1
    • /
    • pp.91-100
    • /
    • 1985
  • This study is on the gate operation of dams, which are for the hydropower and multipurpose in Han River Basin, considering the safety under the emergency. The results of the study on the safety of dams in Han River Basin associated with the gate operation of dams against the design flood flow and the combined inflow are as follows; 1) The empirical formula (1) can be used for gate operation with the informations of reservoir's water level and the inflow. 2) The applicability of the multiple regression formula (2) among the gate opening area, inflow, water level, and outflow is assured. 3) From the safety analysis of dams for the emergency by the procedures developed in this study, six dams are safe except Soyanggang, Euiam, and Cheongpyung Dam, but the above three dams can be safe with the lowering of the starting water level of gate opening by the pre-discharges.

  • PDF

Design and Implementation of Robot-Based Alarm System of Emergency Situation Due to Falling of The Eldely (고령자 낙상에 의한 응급 상황의 4족 로봇 기반 알리미 시스템 설계 및 구현)

  • Park, ChulHo;Lim, DongHa;Kim, Nam Ho;Yu, YunSeop
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.4
    • /
    • pp.781-788
    • /
    • 2013
  • In this paper, we introduce a quadruped robot-based alarm system for monitoring the emergency situation due to falling in the elderly. Quadruped robot includes the FPGA Board(Field Programmable Gate Array) applying a red-color tracking algorithm. To detect a falling of the elderly, a sensor node is worn on chest and accelerations and angular velocities measured by the sensor node are transferred to quadruped robot, and then the emergency signal is transmitted to manager if a fall is detected. Manager controls the robot and then he judges the situation by monitoring the real-time images transmitted from the robot. If emergency situation is decided by the manager, he calls 119. When the fall detection system using only sensor nodes is used, sensitivity of 100% and specificity of 98.98% were measured. Using the combination of the fall detection system and portable camera (robot), the emergency situation was detected to 100 %.

A Research and development of healthcare gateway for international standards that support a WiBro / WiMAX (WiBro/WiMAX 지원 국제표준 헬스케어 게이트웨이 연구 개발)

  • Lee, Jeong-Gi;Kim, Kuk-Se;Kim, Choong-Won;Ahn, Seong-Su
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.12
    • /
    • pp.3020-3028
    • /
    • 2014
  • In the present study, A protocol gateway between agent is designed by using an optimized protocol for the exchange of ISO / IEEE 11073-20601 in order to compensate the disadvantage of the existing gateway and a international standard healthcare set-top. The gate way was designed to smooth data transmission to overcoming the geographical limits of the service and to enable data transfer on emergency vehicle and the mountain area.

Synchronization of ALE signal for HF communication systems (HF통신 시스템을 위한 ALE 신호의 동기)

  • 오상균
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.7
    • /
    • pp.1833-1841
    • /
    • 1996
  • Recently, by emerging of the ALE techniques that make it possible to providereliable communications link automatically, high frequency communiation is newly used as emergency communication and back-up for satellite communications. ALE signal is transmitted in burst, and the received signal is subject to distortions by detrimental multipath fading channels. In the case of that channel, the performance of ALE system is highly dependent upon that of synchronization techniques. In this paper, M-ary FSK signals are detected by a bank of bandpass filter, which is implemented using recusive DFT(Discrete Fourier Transform). Also an acquisition and trancking algorithm are designed uisng parallel structure and early-late-gate methods respectively. Finally, we verify the performance ofthe proposed synchronization algorithm by the computer simulation.

  • PDF

Design and Implementation of PDA-based Image Surveillance System for Harbor Security using IP Camera

  • Shim, Joon-Hwan
    • Journal of Navigation and Port Research
    • /
    • v.31 no.9
    • /
    • pp.779-784
    • /
    • 2007
  • This paper describes a new progressive embedded Internet Protocol(IP) camera available for real-time image transmission. It was applied for ship safety and security on seashore area. The functions of developed embedded system was more effective and excellent than conventional systems. Nowadays, each nation has established harbor security systems to jump up their ports to international port. Recently Incheon port has tried to change man security into center security system used by image security system. The security system of Incheon port has some advantages like effectivity of security system and reduction of manpower and cost, installed by image security system with CCTV cameras at the entrance gate and around the fence. Thus in this paper, we have designed and implemented a Personal Digital Assistants(PDA) based Image Surveillance System for Harbor Security using IP Camera under ubiquitous environment. This system has big advantages which are more effective in an emergency and low cost and small manpower than conventional systems.

Development of Video Work Manual for Rock-Drill Data In Fire Service (소방에서의 도상훈련 기초자료 영상화작업 매뉴얼 개발)

  • Cho, Jae-Kwan;Park, Hee-Jin;Hwang, Inn;Kwon, Hayrran
    • The Korean Journal of Emergency Medical Services
    • /
    • v.6 no.1
    • /
    • pp.103-128
    • /
    • 2002
  • As a result of trying the various manufacturing methods considering the reality of manpower and equipments with this manual, the following standardized procedures and contents can be suggested. (1) Since tools presenting Rock-Drill data must formalize the order of explanation although explainers are different, it will be valid that it is configured by existing power point method rather than by web document type. Composition of contents are selected on the basis of defence card and survey and then 8 items including initial screen, peripheral conditions, mobilization route, general conditions, use and structure by floor, department of vehicle consideration in activities and end screen are included. (2) Making methods and cautions of data included and used in power point are as follows ; - It was most effective that objects of fire fighting and location of neighboring fire fighting water were expressed by electronic map and drawing of inner building was made by scanning it after paining general architecture drawing(plan by each floor) rather than using drawing tools of EXCEL program or CAD drawing. And it was helpful to simplify contents of architecture drawing to wall, stairs and gate in understanding them. - Photographing of video data should be taken to show available fire fighting facilities in fire, use of planned space and the whole inner structure of each floor from the inside of fire fighting buildings and to display play time between 10 sec. and 1 min, for obstacles to distance from adjacent buildings or passage of special vehicles and fire fighting water from the outside of the building. - File format of video data taken in this way is most suitable to use wmv(window media video) or asf(advanced streaming format) type in consideration of time required for export, screen quality, file capacity and play type in Rock-Drill through network. - Still screen(photo) is more effective to express the department of fire fighting vehicles or other equipments than using video. (3) In configuration work of power point, hyper link was used most and configured to see any part at any situation like web document and then uniformity of presentation order of power point was complemented. (4) In case of sales facilities with the area of $35.557m^2$, the time of 22 hours and 30 minutes for five days was taken with five persons. Therefore, when eight-hour works a day were calculated, the whole process of video work for Rock-Drill can be finished with three day works.

  • PDF

Adaptive Noise Canceller of Single Channel For Heart Sound Enhancement (심음 향상을 위한 단일채널 적응 잡음 제거기)

  • Lee, Chul-Hyun;Kim, Pil-Un;Lee, Yun-Jung;Chang, Yong-Min;Bae, Keun-Sung;Cho, Jin-Ho;Kim, Myoung-Nam
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.7
    • /
    • pp.973-982
    • /
    • 2010
  • In this paper, we proposed the single-channel adaptive noise canceller for the enhancement of heart sound (HS) in the auscultation signal. In case of either normal or emergency, a HS diagnosis is difficult due to the various signal source in the chest. Therefore, the HS enhancement is necessary. The conventional active noise canceller(ANC) has two channel, main signal and reference signal. For signal channel, the reference signal in ANC was generated by the proposed HS analyser and BS-Gate based on the characteristic of HS. This reference signal is suitable to the ANC condition. Experimental data were acquisited from MP36, SS30L in BIOPAC Inc., By the experiment, we confirmed that the proposed single-channel ANC was efficient for HS enhancement. And by the comparison with active linear enhancement, it was validate that the proposed ANC is not affected by the variation of a heartbeat.

Preventing disaster system of the subaqueous tunnel under the Han river in the Bundang railway (분당선 한강 하저터널의 방재시스템)

  • Kim Yong-Il;Hwang Nak-Yeon;Yoon Young-Hoon;Jie Hong-Keun;Jang Sung-Wook;Kim Dong-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.308-327
    • /
    • 2004
  • As use of tunnels and subways increase there also are accidents proportionate to it. Daegu Subway Station fire, Hongjimoon tunnel fire led people to be conscious of disaster protection and as a result, there is a trend to adopt standards for fire protection. Accordingly, this thesis is focused on investigating various fire and water protection related issues for subaqueous tunnel under Ran river. The thesis developed evacuation and disaster prevention plan as fire level increases and have identified the suitability of disaster prevention through evacuation and fire simulation, countermeasure of a water leakage during construction and operation considering the subaqueous tunnel. And we selected EPB shield TBM equipment considering the ground condition and effect of boring hole, and accomplished reasonable water protection design through setting goals using event-tree method, as well as examining model test of boring hole and flooding in heavy rain. Also included structured total system consist of water leakage sensing system, water protection gate, pumping system and fire protection system to respond systematically in emergency.

  • PDF