• Title/Summary/Keyword: Emergency Storage

Search Result 148, Processing Time 0.025 seconds

Evaluation Algorithm of Interruption Cost in Distribution Systems Interconnected with Dispersed Storage and Generation Systems (분산형전원이 도입된 배전계통에서의 정전비용산출 알고리즘에 관한 연구)

  • Rho, Dae-Seok;Choi, Jae-Suk;Cha, Jun-Min;Kim, Deok-Young
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.82-84
    • /
    • 2000
  • This paper deals with a evaluation algorithm of interruption cost in distribution systems in the case where Dispersed Storage and Generation (DSG) systems are interconnected with the distribution systems. If DSG systems are operated as the function of the load levelling in distribution systems at the normal conditions and as the uninterruptible power supply in fault areas at the emergency conditions, the reliability improvement of the distribution systems can be expected. In other words, the benefit can be represented by the cost avoiding interruption according to the operation of DSG systems when a fault is occurred. Therefore, this paper presents the evaluation algorithm for interruption cost in order to evaluate the benefit for the uninterruptible power supply of DSG systems in a quantitative manner.

  • PDF

Development of Evaluation System for Agricultural Drought Management (농업가뭄 분석을 위한 농업가뭄평가.정보제공시스템 개발)

  • Park, Ki-Wook;Kim, Jin-Taek;Cheong, Byung-Ho
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.7-13
    • /
    • 2005
  • There are two ways to mitigate the drought. One is the structural measures such as storage of irrigation water, development of emergency wells, etc. The other one is the nonstructural measures such as water saving management by the early warning system. To precast and evaluate the drought, we need to develop the drought indices for agriculture. In the present drought preparedness plans of Ministry of Agriculture and Forestry (MAF), it is prescribed that the preparedness levels should be classified by considering the precipitation, reservoir storage, soil moisture in paddy and upland, and the growing status of crops. However there are not clear quantitative criteria for consistent judgment. This shows that we have not selected and utilized the proper drought index for agriculture and we did not have the information system to calculate the drought indices periodically and warn the outbreak of the drought. The objectives of the study are to develope of Agricultural Drought Evaluation System and to evaluate this indices for current agricultural status using the system.

  • PDF

Design Procedure and Analysis of Ramp Profile in SFF HDD (초소형 하드디스크에서 램프 형상 분석 및 설계 프로세스 연구)

  • Lee, Yong-Hyun;Park, Kyoung-Su;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.2
    • /
    • pp.150-155
    • /
    • 2006
  • Vertical L/UL (Load/Unload) velocity is very important parameter to determine the L/UL performance, and the vertical velocity is determined by the actuator velocity and the ramp profile. However, it is not easy to precisely control the actuator rotating velocity during the L/UL process. Especially in emergency parking, servo system doesn't operate, it is impossible to control an actuator velocity. Then, the vertical unloading velocity depends on only ramp profile. The ramp height and the sliding length for L/UL process in SFF (Small Form Factor) HDD are restricted due to slimness and small media. For these reasons, it is very difficult to design the ramp profile in SFF HDD. Therefore, this study analyzes the unloading dynamic characteristics for various ramp profiles and makes the thesis for ramp profile design.

  • PDF

A Study on the Liquid Tightness Design on LNG Tank Incorporating Cryogenic Temperature-induced Stresses (LNG 탱크의 극저온 온도응력을 고려한 수밀성 설계방법 비교 연구)

  • 전세진;김영진;정철헌;진병무;김성운
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.128-131
    • /
    • 2003
  • In a design of LNG storage tank, one of the major loading conditions that significantly affects liquid tightness of the outer concrete wall is the cryogenic temperature of LNG under the emergency condition of LNG leakage. Proposed in this study are the more consistent procedures to ensure the liquid tightness of LNG tank focusing on the design of prestressing tendon. It is expected that the proposed schemes lead to a more effective serviceability design of LNG tank that satisfies various requirements for the liquid tightness in an efficient manner.

  • PDF

A Study on the Optimal Operation of the Private Cogeneration System (민생용 열병합발전시스템의 최적운전에 관한 연구)

  • Lyu, Seung-Heon;Lee, Jong-Bum;Kim, Chang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.896-898
    • /
    • 1996
  • This paper presents the optimal operation scheduling of the private cogeneration system connected with auxiliary equipments. And the optimal size of auxiliary equipments is determined through evaluations of the minimum operation cost. The optimal operation scheduling is established by using the linear programming method. Simulation results show that the auxiliary boiler is operated as an economical facility but the thermal storage tank is used as a back up facility for emergency.

  • PDF

A Study on Economic Evaluations of ESS Load Test Device for Field Load Test in Fire-fighting Emergency Generator Systems (소방용 비상발전기의 현장부하시험을 위한 ESS 부하시험장치의 경제성평가에 관한 연구)

  • Choi, Seung-Kyou
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.380-386
    • /
    • 2020
  • The ESS load test device (ELTD) can store and exchange electrical energy during the load test of an emergency generator. On the other hand, it is difficult to commercialize ELTDs based on Li-ion batteries because of the high initial cost, which is higher than a load bank test. If the trade of electrical energy stored in ELTD during the test of an emergency generator is considered, it may be possible to commercialize the ELTD. Therefore, this paper proposes an economic model of ELTD composed of the costs and benefits by considering electrical energy trade to perform accurately economic evaluations of an ELTD. From the simulation results of the economic evaluations of an ELTD and the load bank method, it was found that the commercialization of ELTD is possible when the trade in electrical energy in ELTDs is considered.

Design of Fire-fighting Ambulance Interior (119 구급자동차의 내부 디자인 개발에 관한 연구)

  • Shin, Dong-Min;Park, Min-Jung;Han, Yong-Taek
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.121-129
    • /
    • 2016
  • Ambulances are an important element of pre-hospital emergency medical services, and also an important space for improving the work efficiency of paramedics. Paramedics use the interior environment to maximize the capabilities of the space, but ambulances need to be improved to help with the responsibilities of paramedics. A Seamless space was constructed in accordance with the placement of first-aid emergency medical equipment and drugs, and a patient room was loaded in the interior space of an ambulance. This study was to improve the treatment space of an ambulance to improve the efficiency of work by paramedics The new design provides safety and efficiency for emergency medical services through planning of interior storage suitable for the duties of paramedics and through identification and analysis of the problems in the environment.

Research on the emission of electromagnetic waves in ambulance (구급차량 내 전자파 방출에 관한 조사)

  • Yun, Jong-Geun
    • The Korean Journal of Emergency Medical Services
    • /
    • v.23 no.1
    • /
    • pp.61-69
    • /
    • 2019
  • Purpose: The study aims to provide basic data to enhance the health of paramedics responsible for patient transport and treatment by analyzing the exposure level of paramedics to electromagnetic waves generated by electric devices used in ambulances. Methods: The study measured electromagnetic waves in ambulances in N region from July to December 2018. ME3030B produced by German Gigahertz Solutions was used to measure these waves and the maximum value was selected by moving it slowly in various directions. Each measurement part was selected and the mean value was calculated by repeatedly measuring at 10-minute intervals three times in total: $1^{st}$, $2^{nd}$, and $3^{rd}$ phase. Results: Among the electrical devices installed in the patient room of the ambulance measured at distances of 1 cm or 30 cm, results showed a high level of electric waves at the inverter ($26.25{\pm}39V/m$) and high level of electromagnetic waves ($564.00{\pm}31.75nT$) at the ozone sterilizer. According to measurements toward the front near the driver's seat, results indicated high levels of electric waves ($3.67{\pm}1.15V/m$) and electromagnetic waves ($450.00{\pm}19.52nT$) at the black box hard drive. Conclusion: Electromagnetic waves within the ambulance were stable and not beyond the range that might impact human health. However, in the case of the black box hard drive ($3.67{\pm}1.15V/m$, $450.00{\pm}19.52nT$) located under the passenger seat, it may have a direct effect on the human body and, thus it is necessary to move it to a storage area further away from the paramedics to minimized the impact.

Economic Assessment of Customer Owned Battery Energy Storage System (BESS) (수용가용 전자전력저장시스템의 경제성 분석)

  • Choi, Joon-Ho;Kim, Jae-Chul;Hong, Jeong-Suk;Son, Sag-Sig;Im, Tae-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.180-183
    • /
    • 2000
  • The Battery Energy Storage System(BESS) has lots of advantages such as load levelling, quick response emergency power(spinning reserve), frequency and voltage control, improvement of reliability, and deferred generation and transmission construction. The economic feasibility requires justification from the customer side of meter to promoting the dissemination of BESS nationally. In this paper, we proposed the economic assessment model of customer owned Battery Energy Storage System(BESS) which is complemented and improved the existing model. The proposed model is applied to the typical customer type(light-industrial commercial, and residential) which are taken from the statistical analysis on the load profile survey of Korea Electric Power COmpany (KEPCO). The economic assessment performed for each customer type to justifying their economic feasibility of BESS installation from the economic measures such as payback period, overall benefits, ROI, and ROR. The results of this paper are useful to the customer investment decision making and the national energy policy & strategy.

  • PDF

Modeling and Control of Integrated STATCOM-SMES System to Improve Power System Oscillations Damping

  • Molina, Marcelo G.;Mercado, Pedro E.
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.4
    • /
    • pp.528-537
    • /
    • 2008
  • Primary frequency control(PFC) has the ability to regulate short period random variations of frequency during normal operation conditions and also to respond rapidly to emergencies. However, during the past decade, numerous significant sized blackouts occurred worldwide that resulted in serious economic losses. Therefore, the conclusion has been reached that the ability of the current PFC to meet an emergency is poor, and security of power systems should be improved. An alternative to enhance the PFC and thus security is to store excessive amounts of energy during off-peak load periods in efficient energy storage systems for substituting the primary control reserve. In this sense, superconducting magnetic energy storage(SMES) in combination with a static synchronous compensator(STATCOM) is capable of supplying power systems with both active and reactive powers simultaneously and very rapidly, and thus is able to enhance the security dramatically. In this paper, a new concept of PFC based on incorporating a STATCOM-SMES is presented. A complete detailed model is proposed and a new control scheme is designed, comprising an enhanced frequency control scheme, and a fully decoupled current control strategy in d-q coordinates with a novel controller to prevent dc bus capacitors voltage drift/imbalance. The performance of the proposed control schemes is validated through digital simulation carried out using MATLAB/Simulink.