• Title/Summary/Keyword: Emergency Monitoring

Search Result 477, Processing Time 0.027 seconds

Assessment of Applicability of Portable HPGe Detector with In Situ Object Counting System based on Performance Evaluation of Thyroid Radiobioassays

  • Park, MinSeok;Kwon, Tae-Eun;Pak, Min Jung;Park, Se-Young;Ha, Wi-Ho;Jin, Young-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.2
    • /
    • pp.83-90
    • /
    • 2017
  • Background: Different cases exist in the measurement of thyroid radiobioassays owing to the individual characteristics of the subjects, especially the potential variation in the counting efficiency. An In situ Object Counting System (ISOCS) was developed to perform an efficiency calibration based on the Monte Carlo calculation, as an alternative to conventional calibration methods. The purpose of this study is to evaluate the applicability of ISOCS to thyroid radiobioassays by comparison with a conventional thyroid monitoring system. Materials and Methods: The efficiency calibration of a portable high-purity germanium (HPGe) detector was performed using ISOCS software. In contrast, the conventional efficiency calibration, which needed a radioactive material, was applied to a scintillator-based thyroid monitor. Four radioiodine samples that contained $^{125}I$ and $^{131}I$ in both aqueous solution and gel forms were measured to evaluate radioactivity in the thyroid. ANSI/HPS N13.30 performance criteria, which included the relative bias, relative precision, and root-mean-squared error, were applied to evaluate the performance of the measurement system. Results and Discussion: The portable HPGe detector could measure both radioiodines with ISOCS but the thyroid monitor could not measure $^{125}I$ because of the limited energy resolution of the NaI(Tl) scintillator. The $^{131}I$ results from both detectors agreed to within 5% with the certified results. Moreover, the $^{125}I$ results from the portable HPGe detector agreed to within 10% with the certified results. All measurement results complied with the ANSI/HPS N13.30 performance criteria. Conclusion: The results of the intercomparison program indicated the feasibility of applying ISOCS software to direct thyroid radiobioassays. The portable HPGe detector with ISOCS software can provide the convenience of efficiency calibration and higher energy resolution for identifying photopeaks, compared with a conventional thyroid monitor with a NaI(Tl) scintillator. The application of ISOCS software in a radiation emergency can improve the response in terms of internal contamination monitoring.

On-Line Condition Monitoring of Electrical Equipment Using Temperature Sensor (온도센서를 이용한 전력설비의 온라인 상태 감시)

  • Choi, Yong-Sung;Kim, Sun- Jae;Kim, Yeong-Min;Song, Hwao-Kee;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.202-208
    • /
    • 2008
  • Condition monitoring technologies allow achieving this goal by minimizing downtime through the integrated planning and scheduling of repairs indicated by condition monitoring techniques. Thermal runaways induced by conduction problems deteriorate insulating material and cause disruptive dielectric discharges resulting in arcing faults. Therefore, having the ability to directly measure the temperature of the contacts while in service will provide more information to determine the true condition of the equipment. It allows connective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on -line condition monitoring of energized equipment is applicable both as stand alone system and with an interface for power quality monitoring system. The paper presents the results of wireless temperature monitoring: of electrical equipment at a power plant.

Correlation Between Pulmonary Contusion and Myocardial Contusion in Patients with Multiple Injuries (다발성 외상환자에서 폐좌상과 심근좌상의 상관관계)

  • Ryu, Ji-Ho;Yeom, Seok-Ran;Jeong, Jin-Woo;Min, Mun-Ki;Park, Maeng-Real;Kim, Yong-In;Han, Sang-Kyun;Park, Sung-Wook
    • Journal of Trauma and Injury
    • /
    • v.24 no.1
    • /
    • pp.31-36
    • /
    • 2011
  • Purpose: This study was conducted to evaluate the correlations among pulmonary contusion severity, trauma score and cardiac troponin I (cTnI) level. Methods: We prospectively evaluated patients with multiple injuries who had been admitted to the emergency department (ED) from July 2007 to July 2008. We first measured the total creatinine kinase (CK), the MB fraction of CK (CK-MB), TnI, and myoglobin within 2 hours after the injury. We then checked the electrocardiogram, x-ray, and computed tomography (CT) results. Finally, we assessed the injuries as variables and then compared the results for patients with elevated TnI levels (group A) and patients whose TnI levels fell within the normal range (group B). Results: Eighty-six of the 92 patients admitted to the ED were enrolled. The pulmonary contusion score (PCS) was well correlated with $PaO_2/FiO_2$. TnI levels were correlated with PCS. When TnI levels were above 0.86 ng/ml, the mortality was estimated with 100% sensitivity and 86.1% specificity. Conclusion: Pulmonary contusion severity is correlated with TnI level. When the PCS is high and the cTnI level is elevated in multiple-injury patients, we recommend continuous cardiac monitoring and further evaluation

Images of Hospital Emergency Medical Technicians Perceived by Emergency Medical Service Providers (Focusing on tertiary medical institutions in Daejeon and Chungcheongnam do) (응급의료종사자가 인식하는 병원 내 응급구조사의 이미지 (대전, 충남 3차의료기관 중심으로))

  • Han, Song-Yi;Bae, Ki-Sook;Kim, Jin-Uk
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.4
    • /
    • pp.373-379
    • /
    • 2012
  • This study surveyed the image of hospital emergency medical technicians with 122 emergency medical service providers (doctors and nurses) working at tertiary medical institutions in Daejeon and Chungcheongnam.do in order to provide basic materials for enhancing the status and professional image of hospital emergency medical technicians. According to the results of this study, the overall image was $3.27{\pm}0.34$, and by its sub.area, professional image was highest and role image was lowest. By item, 'Maintain a friendly relations with doctors' was highest, and 'Arrogant and negligent in job performance' was lowest. In order to enhance their image, hospital emergency medical technicians need to assume a sincere attitude toward patients and colleagues consistently, to strengthen their professionalism, and to carry out their duties and roles faithfully. What is more, the association should take proper measures and to establish the sound image of emergency medical technician as a professional through active campaigns and monitoring using mass media.

Conceptual Design of Navigation Safety Module for S2 Service Operation of the Korean e-Navigation System

  • Yoo, Yun-Ja;Kim, Tae-Goun;Song, Chae-Uk;Hu, Shouhu;Moon, Serng-Bae
    • Journal of Navigation and Port Research
    • /
    • v.41 no.5
    • /
    • pp.277-286
    • /
    • 2017
  • IMO introduced e-Navigation concept to improve the efficiency of ship operation, port operation, and ship navigation technology. IMO proposed sixteen MSPs (Maritime Service Portfolio) applicable to the ships and onshore in case of e-Navigation implementation. In order to meet the demands of the international society, the system implementation work for the Korean e-Navigation has been specified. The Korean e-Navigation system has five service categories: the S2 service category, which is a ship anomaly monitoring service, is a service that classifies emergency levels according to the degree of abnormal condition when a ship has an abnormality in ship operation, and provides guidance for emergency situations. The navigation safety module is a sub-module of the S2 service that determines the emergency level in case of navigation equipment malfunctioning, engine or steering gear failure during navigation. It provides emergency response guidance based on emergency level to the abnormal ship. If an abnormal condition occurs during the ship operation, first, the ship shall determine the emergency level, according to the degree of abnormality of the ship. Second, an emergency response guidance is generated based on the determined emergency level, and the guidance is transmitted to the ship, which helps the navigators prevent accidents and not to spread. In this study, the operational concept for the implementation of the Korean e-Navigation system is designed and the concept is focused on the navigation safety module of S2 service.

Status of region-wise deployment of 119 emergency resources in Korea -Focusing on whether regional criteria are met and the characteristics of the region- (국내 119구급자원의 지역별 배치 현황 -시·군·구별 기준 충족 여부와 지역특성을 중심으로-)

  • Hyeji Kwon;Youngjeon Shin
    • The Korean Journal of Emergency Medical Services
    • /
    • v.28 no.2
    • /
    • pp.157-172
    • /
    • 2024
  • Purpose: Ensuring prompt and consistent 119 emergency services for all citizens is crucial and requires every region to adhere to prescribed deployment standards Methods: This study assessed the compliance with 119 emergency resource deployment standards in 229 districts (si-gun-gu) by analyzing data from 18 fire headquarters as of December 31, 2022. Results: At the Sigun-gu level, 16 areas (7%) did not meet the fire station standards. Among the 229 si-gun-gu, 25 (10.9%) failed operational ambulance standards, and 114 (49.8%) did not meet the 119 first responder standards. Areas lacking fire station standards had lower financial self-sufficiency and higher elderly and single-person elderly household proportions (p<.05). Areas not meeting ambulance standards had lower proportions of these populations, but higher financial self-sufficiency. In addition, areas that did not meet the 119 first-responder standards had greater financial autonomy (p<.05). Areas meeting only basic fire station standards had higher proportions of elderly and single-person households and lower financial self-sufficiency. Areas meeting only ambulance standards had lower financial autonomy, whereas those meeting only emergency medical technician standards had lower financial self-sufficiency and a higher elderly proportions (p<.05). Conclusion: Si-gun-gu, with a large elderly population and poor finances, often fails to meet fire station standards and meets only the basic criteria. Continuous monitoring and targeted management are crucial for reducing disparities in 119 resource allocation and improving the overall deployment.

Design and Implementation of Ubiquitous Sensor Network System for Monitoring the Bio-information and Emergency of the Elderly in Silver Town

  • Choi, Seong-Ho;Park, Hyung-Kun;Yu, Yun-Seop
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.2
    • /
    • pp.219-222
    • /
    • 2010
  • An ubiquitous sensor network (USN) system to monitor the bio information and the emergency of the elderly in the silver town is presented. The USN system consists of the sensor node platforms based on MCU of Atmage128L and RF Chip of CC2420 satisfying IEEE 802.15.4, which includes the bios sensor module such as the electrocardiogram (ECG) sensor and the temperature sensor. Additionally, when an emergency of the elderly is occurred in the silver town, the routing algorithm suitable to find and inform the location of the elderly is proposed, and the proposed routing algorithm is applied to the USN. To collect and manage the ECG data at the PC connected to the sink node, LabView software is used. The bio information and the emergency of the elderly can also be monitored at the client PC by TCP/IP networks in the USN system.

Implementation of Intelligent Speech Recognition System according to CCTV Emergency Information (CCTV 응급상황에 따른 지능형 음성인식 시스템 구현)

  • Cho, Young-Im;Jang, Sung-Soon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.19 no.3
    • /
    • pp.415-420
    • /
    • 2009
  • For the emergency detecting in general CCTV environment of our daily life, the monitoring by only images through CCTV information occurs some problems especially in cost as well as man power. Therefore, in this paper, for detecting emergency state dynamically through CCTV as well as resolving some problems, we propose our advanced speech recognition system. For the purpose of it, we adopt HMM(Hidden Markov Model) in our system to do a feature extraction. Also, we adopt Wiener filter technique for noise elimination in many information coming from on CCTV environment. In this paper, our system send only the emergency speech information to a manager to deal with emergency state effectively.

Experiences of Emergency Surgical Treatment for a COVID-19 Patient with Severe Traumatic Brain Injury at a Regional Trauma Center: A Case Report

  • Yun, Jung-Ho
    • Journal of Trauma and Injury
    • /
    • v.34 no.3
    • /
    • pp.212-217
    • /
    • 2021
  • Various medical scenarios have arisen with the prolonged coronavirus disease 2019 (COVID-19) pandemic. In particular, the increasing number of asymptomatic COVID-19 patients has prompted reports of emergency surgical experiences with these patients at regional trauma centers. In this report, we describe an example. A 25-year-old male was admitted to the emergency room after a traffic accident. The patient presented with stuporous mentality, and his vital signs were in the normal range. Lacerations were observed in the left eyebrow area and preauricular area, with hemotympanum in the right ear. Brain computed tomography showed a contusional hemorrhage in the right frontal area and an epidural hematoma in the right temporal area with a compound, comminuted fracture and depressed skull bone. Surgical treatment was planned, and the patient was intubated to prepare for surgery. A blood transfusion was prepared, and a central venous catheter was secured. The initial COVID-19 test administered upon presentation to the emergency room had a positive result, and a confirmatory polymerase chain reaction (PCR) test was administered. The PCR test confirmed a positive result. Emergency surgical treatment was performed because the patient's consciousness gradually deteriorated. The risk of infection was high due to the open and unclean wounds in the skull and brain. We prepared and divided the COVID-19 surgical team, including the patient's transportation team, anesthesia team, and surgical preparation team, for successful surgery without any transmission or morbidity. The patient recovered consciousness after the operation, received close monitoring, and did not show any deterioration due to COVID-19.

Use of gaze entropy to evaluate situation awareness in emergency accident situations of nuclear power plant

  • Lee, Yejin;Jung, Kwang-Tae;Lee, Hyun-Chul
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1261-1270
    • /
    • 2022
  • This study was conducted to investigate the possibility of using gaze entropy to evaluate an operator's situation awareness in an emergency accident situation of a nuclear power plant. Gaze entropy can be an effective measure for evaluating an operator's situation awareness at a nuclear power plant because it can express gaze movement as a single comprehensive number. In order to determine the relationship between situation awareness and gaze entropy for an emergency accident situation of a nuclear power plant, an experiment was conducted to measure situation awareness and gaze entropy using simulators created for emergency accident situations LOCA, SGTR, SLB, and LOV. The experiment was to judge the accident situation of nuclear power plants presented in the simulator. The results showed that situation awareness and Shannon, dwell time, and Markov entropy had a significant negative correlation, while visual attention entropy (VAE) did not show any significant correlation with situation awareness. The results determined that Shannon entropy, dwell time entropy, and Markov entropy could be used as measures to evaluate situation awareness.