• Title/Summary/Keyword: Embedded wall

Search Result 186, Processing Time 0.022 seconds

Study on the Spin-up of Fluid in a Semi-Circular Container Using a Zonal-Embedded-Grid Method (국소적 격자 삽입법을 이용한 반원주 내의 스핀업 유동 특성에 대한 연구)

  • Suh Yong Kweon;Yeo Chang Ho
    • Journal of the Korean Society of Visualization
    • /
    • v.2 no.2
    • /
    • pp.32-37
    • /
    • 2004
  • In this paper the numerical method with a zonal embedded grid system for an incompressible flow within a semi-circular container is presented. The algorithm is validated by its application to some typical flow models including the spin-up flow inside a semi-circular geometry. Flow visualization for the spin-up flows was used by PIV. The results show that at high Reynolds numbers the cyclonic cell at the left-hand side region moves along the circular wall and merges with the cell at the right-hand side region.

  • PDF

Study on the Spin-up of Fluid in a Semi-Circular Container Using a Zonal-Embedded-Grid Method (국소적 격자 삽입법을 이용한 반 원주 내의 스핀업 유동에 대한 연구)

  • Yeo, Chang-Ho;Suh, Yong-Kweon
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1885-1890
    • /
    • 2004
  • In this paper the numerical method with a zonal embedded grid system was applied to the spin-up flow within a semi-circular container. Flow visualization was also performed on a rotating table. The results show that at a low level of damping (i.e. low viscosity and high liquid depth) a cyclonic cell produced initially near the left-hand-side corner of the container moves along a wall and merged with the cell on the right-hand-side.

  • PDF

A research on the technique for the vibration analysis of fuid-filled, strength member embedded and semi-infinite cylindrical shell (유체 충진된 반 무한 내심형 원통셸의 진동 해석 기법 연구)

  • Ham, Il-Bae;Bae, Soo-Ryong;Jeong, Weui-Bong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.12
    • /
    • pp.127-134
    • /
    • 1997
  • Abstract: A technique to analyze the vibrations of internally fluid-filled, semi-infinite cylindrical shell which has strength members embedded in the shell wall under the axial static tension conditon is presented by using the characteristic wave propagation theory based on the transfer matrix calculated from the finite element matrices of a short module section, with spatial Laplace Tranform technique, and is verified by comparison with the measured results of the test performed on a real module model, and the effects of the embedded strength members on the vibrational response is calculated and discussed.

  • PDF

Site Monitoring of the Retaining Wall Reinforced by Geogrids with Block Type Facings (지오그리드 보강토 옹벽의 계측평가)

  • Kim, Jin-Man;Lee, Dae-Young;Ma, Sang-Joon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.1
    • /
    • pp.106-114
    • /
    • 2006
  • Uses of geosynthetics as a reinforcing material for earth structures have ever increased due to their excellent economy. fine external appearance. and easy construction. In the current practice of geosynthetics. however, the lacks of the standardized method of evaluating the soil/geosynthetics friction properties and the inconsistency of conventional design methods develop confusion to the civil engineers. The purpose of site monitoring of the retaining wall reinforced by geogrids was to evaluate the applicability of existing design methods to, and performance of. CHAMSTONE wall system. Full scale field performance during and after construction was monitored by incorporating instrumentation including strain gauges on the geogrid and soil pressure cells. The difference of the reinforcing effects of geosynthetics embedded in the soil will be also investigated by comparing of the line and curve types of retaining wall reinforced by geogrids with block type facings.

NON LINEAR VARIABLE VISCOSITY ON MHD MIXED CONVECTION HEAT TRANSFER ALONG HIEMENZ FLOW OVER A THERMALLY STRATIFIED POROUS WEDGE

  • Kandasamy, R.;Hashim, I.;Ruhaila, K.
    • Journal of applied mathematics & informatics
    • /
    • v.26 no.1_2
    • /
    • pp.161-176
    • /
    • 2008
  • The effect of variable viscosity on MHD mixed convection Hiemenz flow over a thermally stratified porous wedge plate has been studied in the presence of suction or injection. The wall of the wedge is embedded in a uniform Darcian porous medium in order to allow for possible fluid wall suction or injection and has a power-law variation of the wall temperature. An approximate numerical solution for the steady laminar boundary-layer flow over a wall of the wedge in the presence of thermal diffusion has been obtained by solving the governing equations using numerical technique. The fluid is assumed to be viscous and incompressible. Numerical calculations are carried out for different values of dimensionless parameters and an analysis of the results obtained shows that the flow field is influenced appreciably by the magnetic effect, variable viscosity, thermal stratification and suction / injection at wall surface. Effects of these major parameters on the transport behaviors are investigated methodically and typical results are illustrated to reveal the tendency of the solutions. Comparisons with previously published works are performed and excellent agreement between the results is obtained.

  • PDF

Hydrodynamic coupling distance between a falling sphere and downstream wall

  • Lin, Cheng-Chuan;Huang, Hung-Tien;Yang, Fu-Ling
    • Coupled systems mechanics
    • /
    • v.7 no.4
    • /
    • pp.407-420
    • /
    • 2018
  • In solid-liquid two phase flow, the knowledge of how descending solid particles affected by the presence of downstream wall is important. This work studies at what interstitial distance the velocity of a vertically descending sphere is affected by a downstream wall as a consequence of wall-modified hydrodynamic forces through a validated dynamic model. This interstitial distance-the hydrodynamic coupling distance ${\delta}_c-is$ found to decay monotonically with the approach Stokes number St which compares the particle inertia to viscous drag characterized by the quasi-steady Stokes' drag. The scaling relation ${\delta}_c-St-1$ decays monotonically as literature below the value of St equal to 10. However, the faster diminishing rate is found above the threshold value from St=10-40. Furthermore, an empirical relation of ${\delta}_c-St$ shows dependence on the drop height which clearly indicates the non-negligible effect of unsteady hydrodynamic force components, namely the added mass force and the history force. Finally, we attempt a fitting relation which embedded the particle acceleration effect in the dependence of fitting constants on the diameter-scaled drop height.

Pre-estimate on Structural Behavior and Cracks of Subway Wall Structures Using Gage Measurement (계측에 의한 지하철 박스구조물 벽체부의 균열 밑 구조거동 예측)

  • Kim, Young-Jin;Kim, Sang-Chel
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.6 s.37
    • /
    • pp.657-663
    • /
    • 2006
  • By measuring concrete temperature and strains of concrete and reinforcing bars throughout gages embedded and also by observing the crack occurrence, this study aims at the characteristics of structural behavior of subway wall structure in associate with concrete ages. The length of 23.5m, thickness of 2.0m of real subway custody line was selected as a representative structure and 7 thermocouples and 6 strain gages were installed to measure the behavior of wall structure. The results were compared and verified with analytical results using MIDAS in order to show their usefulness. It was found that only attachment of strain gages on the surface of reinforcing bars can figure out the timing of crack occurrence and hydration heat program is useful to estimate comparatively exact magnitudes of temperature. Since estimated time of crack occurrence throughout thermal stress analysis depends on the period of transferred thermal stress from concrete to reinforcing bars, however, cracks from naked eyes were identified later than analytical results. Cracks were observed first at the center of wall line and then to the end of line symmetrically.

Field Application of Up-Up Construction Using Buried Wale Continuous Walt System Method (CWS공법(Buried Wale Continuous Wall System)을 적용한 Up-Up 시공사례)

  • Lee Jeong-Bae;Lim In-Sig;Kim Dong-Hyun;Oh Bo-Hwan;Ha In-Ho;Rhim Hong-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.1-4
    • /
    • 2006
  • A down construction method is frequently used in these days to reduce popular discontent and to assure sufficient working space at early stage in downtown area. There are two main problems in the existing down construction method. One is a confliction between frame works and excavation works, and the other is a cold joint in retaining wall which is unavoidable due to a sequence of concrete placement and induces a water leakage. Therefore, a new method is needed to overcome these problems. The CWS (buried wale Continuous Wall System) method was developed by authors. By replacing RC perimeter beam with embedded steel wale, the steel frame works of substructure can be simplified and the water leakage can be prevented using continuous retaining wall. Consequently, the improved duality and reduction of construction period can be obtained from CWS method.

  • PDF

Strain measurement of optical fiber embedded in the reinfoned retaining wall used in the railway (광섬유가 삽입된 철도용 보강토 옹벽의 초기 변형을 측정)

  • Yoon, Hyuk-Jin;Song, Kwang-Yong;Kim, Dae-Sang;Kim, Ki-Hwan;Kim, Jung-Seok;Kwon, Tae-Soo;Na, Hee-Seung
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1509-1513
    • /
    • 2009
  • The research of applying reinforced retaining wall due to support the land pressure that given from train's load has been accomplished actively in domestic area. After the retaining wall has been installed, the collapse or partial destruction that generated by effect of train's vibration and repetitive load of train may be induced. Accordingly in the period of using this, the sufficient durability should be guaranteed and years of durability are one hundred and as these are longer than road structure's, the technique that introduced to wall and monitor the long-term strain is necessary. In this paper, the optical fibre is induced vertically to the reinforced retaining wall and after the subsistence of optical fibre is confirmed, the early strain that applied to optical fibre after insertion is monitored. Before and after the concrete placing, damage feasibility of optical fibre is measured by using OTDR(Optical Time Domain Reflectometer) and after concrete is cultivated, the early strain induced to optical fibre is measured by application of BOCDA (Brillouin Correlation Domain Analysis) system.

  • PDF

Experimental study on cyclic behavior of reinforced concrete parallel redundancy walls

  • Lua, Yiqiu;Huang, Liang
    • Structural Engineering and Mechanics
    • /
    • v.52 no.6
    • /
    • pp.1177-1191
    • /
    • 2014
  • Reinforced concrete (RC) shear walls are one of the most commonly used lateral-load resisting systems in high-rise buildings. RC Parallel redundancy walls studied herein consist of two parts nested to each other. These two parts have different mechanical behaviors and energy dissipation mechanisms. In this paper, experimental studies of four 1/2-scale specimens representing this concept, which are subjected to in-plane cyclic loading, are presented and test results are discussed. Two specimens consist of a wall frame with barbell-shaped walls embedded in it, and the other two consist of a wall frame and braced walls nested each other. The research mainly focuses on the failure mechanism, strength, hysteresis loop, energy dissipation capacity and stiffness of these walls. Results show that the RC parallel redundancy wall is an efficient lateral load resisting component that acts as a "dual" system with good ductility and energy dissipation capacity. One main part absorbs a greater degree of the energy exerted by an earthquake and fails first, whereas the other part can still behave as an independent role in bearing loads after earthquakes.