• 제목/요약/키워드: Emago

검색결과 12건 처리시간 0.028초

디지털 공제술에서 비표준화 방사선사진의 대조도 및 기하학적 보정에 관한 연구 (Contrast and geometric correction of non-standardized radiographs in digital subtraction radiography)

  • 김은경
    • Journal of Periodontal and Implant Science
    • /
    • 제28권4호
    • /
    • pp.797-809
    • /
    • 1998
  • The purposes of this study were to develop the computer program for the contrast and geometric correction in digital subtration radiography with the IDL (Interactive Data Language) and compare the results with this program for the correction of the non-standardized radiographs to those of standardized radiographs and those with "Emago" software, the commercial program for the correction. The procedures were written for the contrast correction and subtraction with the geometric correction, using IDL. 32 pairs of periapical radiographs of premolar and molar portion of two dry human mandibles were taken at two different occasions with XCP film holder(nonstandardized films) and another 32 pairs with customized XCP film holder(standardized films). Subtraction of standardized film pairs was performed. Subtraction after the contrast and geometric correction of non-standardized films was performed using the newly developed program and Emago software. Standard deviations of grey levels of the subtracted images by the newly developed program were compared with those of the standardized group and Emago-corrected group. Standard deviations of grey levels of new program-corrected group were much smaller than those of the Emago-corrected group (p<0.001) and slightly larger than those of standardized group (p<0.05). However, the difference was very minute. This study indicates that the newly developed program written with IDL may substitute the mechanical standardization for digital subtraction radiography.

  • PDF

재구성영상 형성방법에 따른 디지털영상공제술의 정확성 비교연구 (A comparative study on the accuracy of digital subtraction radiography according to the aquisition methods of reconstructed images)

  • 허영준;전인성;허민석;이삼선;최순철;박태원;김종대
    • Imaging Science in Dentistry
    • /
    • 제32권2호
    • /
    • pp.107-111
    • /
    • 2002
  • Purpose : To compare the accuracy of digital subtraction images acquired by two different methods different in positioning four reference points for geometrical standardization. Materials and Methods : A total of 36 digital radiographic images of 6 volunteers were taken at the areas of the incisor, premolar, and molar of both the maxilla and mandible using the Digora system. Each image was moved 4 mm vertically and horizontally. Four oral and maxillofacial radiologists performed digital subtraction radiography between the paired images before and after movement using Emago (Oral Diagnostic Systems, Amsterdam, The Netherlands) and Sunny (Biomedisys Co., Seoul, Korea). The standard deviation of the internal gray value in Region of Interest (ROI) was statistically analyzed between the two programs using the paired t-test. Results : The standard deviation of pixel gray values from the digital subtraction images using the Sunny program were lower than that of the Emago program (p<0.05). All observers showed significant differences between each other when the Sunny program was used (p<0.05), but one observer showed a significantly higher score than other observers when they used Emago (p<0.05). The standard deviations of premolar area from both Sunny and Emago programs were significantly higher than those of anterior and molar regions (p<0.05). Conclusion: The subtracted images using the Sunny program were more accurate and sensitive than those taken using the Emago program.

  • PDF

디지털공제프로그램간의 디지털공제영상 비교 (A comparison of subtracted images from dental subtraction programs)

  • 한원정
    • Imaging Science in Dentistry
    • /
    • 제32권3호
    • /
    • pp.147-151
    • /
    • 2002
  • Purpose: To compare the standard deviation of gray levels on digital subtracted images obtained by different dental subtraction programs. Materials and Methods: Paired periapical films were taken at the lower premolar and molar areas of the phantoms involving human mandible. The bite registration group used Rinn XCP equipment and bite registration material, based on polyvinyl siloxane, for standardization. The no bite registration group used only Rinn XCP equipment. The periapical film images were digitized at 1200 dpi resolution and 256 gray levels by a flat bed scanner with transparency unit. Dental digital subtraction programs used for this study were Subtractor (Biomedisys Co., Korea) and Emago (Oral Diagnostic Systems, The Netherlands). To measure the similarities between the subtracted images, the standard deviations of the gray levels were obtained using a histogram of subtracted images, which were then analyzed statistically. Results: Subtracted images obtained by using the Emago program without manual selection of corresponding points showed the lowest standard deviation of gray levels (p<0.01). And the standard deviation of gray levels was lower in subtracted images in the group of a bite registration than in the group of no use of bite registration (p < 0.01). Conclusion: Digital radiographic subtraction without manual selection of reference points was found to be a convenient and superior method.

  • PDF

디지털 공제술을 이용한 platform switching 임플란트의 변연골 소실에 대한 연구 (Evaluation of marginal bone loss around platform-switched implants by digital subtraction radiography)

  • 김치윤;김성숙;인희선;김유리
    • 구강회복응용과학지
    • /
    • 제31권1호
    • /
    • pp.33-44
    • /
    • 2015
  • 목적: 본 연구는 platform matching, platform switching을 시행한 임플란트의 변연골 소실을 비교하여 platform switching 개념의 임상적 의의를 평가하고자 한다. 연구 재료 및 방법: 원광대학교 치과병원 임플란트 센터에서 치료를 진행한 환자를 대상으로 임플란트 식립 시기, 직경, 길이, 지대주 연결방법 및 보철물 연결고정 유무를 조사하였다. 변연골 소실량을 측정하기 위해서 Emago advanced v5.6 프로그램을 사용하여 임플란트 식립 시와 가장 최근 내원 시의 치근단 방사선 사진을 비교하였다. 결과: 환자 82명의 임플란트 150개를 대상으로 6 - 63개월 동안 관찰한 결과 platform matching 임플란트는 $1.16{\pm}0.54mm$, platform switching 임플란트는 $0.68{\pm}0.27mm$의 변연골 소실을 나타내었다. 결론: Platform switching을 시행함으로써 임플란트의 변연골 소실을 줄이는 효과가 있는 것으로 사료된다.

Assessing changes of peri-implant bone using digital subtraction radiography

  • Kwon Ji-Yung;Kim Yung-Soo;Kim Chang-Whe
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.273-281
    • /
    • 2001
  • Digital subtraction radiography may be one of the most precise and noninvasive methods for assessing subtle density changes in peri-implant bone, providing additional diagnostic information on implant tissue integration in overall maintenance. The aims of this study were to evaluate density changes after first, second surgery of dental implant and to measure the amount of marginal bone loss 9 months after second surgery using digital subtraction radiography. Bone change around 30 screw-shaped implants in 16 patients were assessed on radiographs. 17 Branemark implants of 3.75mm in diameter(Nobel Biocare, Goteborg, Sweden), 2 Branemark implants of 5.0mm in diameter, 11 $Replace^{TM}$ implants of 4.3mm in diameter(Nobel Biocare, Goteborg, Sweden) were used. To standardize the projection geometry of serial radiographs of implants, customized bite block was fabricated using XCP film holder(Rinn Corporation, Elgin, IL.) with polyether impression material of Impregum(ESPE, Germany) and direct digital image was obtained. Qualitative and quantitative changes on radiographs were measured with Emago software(The Oral Diagnostic System, Amsterdam, Netherlands). The results were as follows: 1. The peri-implant bone density of 69.2% implants did not change and the peri-implant bone density of 30.8% implants decreased after 3 months following first surgery. 2. The crestal bone density of 53.9% implants decreased first 3 months after second surgery. The crestal bone density of 58.8% implants increased 9 months after second surgery. No density change was observed around the midportion of the implants after second surgery, 3. The amount of marginal bone loss between different kinds of implants showed no statistically significant differences (p>0.05). 4. More than 90% of total marginal bone loss recorded in a 9-month period occurred during the first 3 months.

  • PDF

치조열 환자의 장골이식술 후 예후 평가 (A Prognosis Evaluation after Iliac Bone Graft in Cleft Alveolus Patients)

  • 홍진호;소병수;백진아;신효근
    • 대한구순구개열학회지
    • /
    • 제4권2호
    • /
    • pp.69-78
    • /
    • 2001
  • Alveolar cleft exists in 75% of cleft patients, In alveolar cleft patients, alar base is widening, palatal fistular formation, maxillary growth disturbance & tooth loss of adjacent area is raised, Alveolar bone grafting, especially iliac bone grafting, is a general treatment method. As operation timing, bone grafting is classified with primary, early secondary, secondary, & late secondary, Here we report cleft width, marginal bone height, bone resorption rate, grafted shape & bone densities after secondary iliac bone grafting was done in the Dept. of oral and maxillofacial surgery of chonbuk national university hospital. We compared cleft width to bone resorption rate and grafted shape. Also, alveolar bone densities of grafted and contralateral site was compared with Emago 3 package? (Oral Diagonostic System, The Netherlands), The data obtained were analyzed using Spearman's rho coefficients and sign test with SPSS for window, The results were obtained as follows. 1. As alveolar cleft width is increase, bone resorption rate is, too. This relation showed significant difference(P<.01). 2, In proximal & distal area, alvolar cleft width and bone graft contour after bone grafting had a reverse proportional difference. It was not significant difference(P>.05). 3. After 3 month, in bone density results by using Emago 3 package? with periapical standard view, occlusal view & panoramic view, differences between grafted bone and alveolar bone of contralateral site didn't show a significant difference(P>.05). Thus, differences of bone densities in the alveolar bones didn't exist.

  • PDF

디지털 공제방사선영상의 기하학적 보정에 관한 연구 (A study on the geometric correction for the digital subtraction radiograph)

  • 임숙영;고광준
    • Imaging Science in Dentistry
    • /
    • 제31권1호
    • /
    • pp.23-34
    • /
    • 2001
  • Purpose : To develop a new subtraction program for registering digital periapical images based on the correspondence of anatomic structures. Materials and Methods: The digital periapical images were obtained by Digora system with Rinn XCP equipment after translation of 1-16 mm, and rotation of 2-20° at the premolar and molar areas of the human dried mandible. The new subtraction program, NIH Image program and Emago/Advanced program were compared by the peak-signal-to noise ratio (PSNR). Results : The new subtraction program was superior to NIH Images program and Emagol Advanced program up to 16 mm translation and horizontal angulation up to 4°. Conclusion: The new subtraction program can be used for subtracting digital periapical images.

  • PDF

상악 전치부에서 골 이식 유무에 따른 임플란트 변연골 소실에 관한 후향적 연구 (Retrospective study on marginal bone loss around maxillary anterior implants with or without bone graft)

  • 황희선;정지혜;김유리
    • 대한치과보철학회지
    • /
    • 제54권2호
    • /
    • pp.103-109
    • /
    • 2016
  • 목적: 상악 전치부 임플란트 식립시 골 이식 유무에 따른 임플란트의 변연골 소실량을 측정, 비교하여 임플란트 식립과 동시에 시행하는 골 이식의 임상적 의의를 평가하고자 한다. 대상 및 방법: 2011년 6월부터 2014년 5월 사이에 원광대학교 치과병원 임플란트 센터에서 상악 전치부에 임플란트를 식립하고 보철치료를 진행한 환자를 대상으로 진료기록부를 확인하여 임플란트 식립 시기, 고정체의 직경 및 길이, 지대주 연결방법, 골이식 유무를 조사하였다. 임플란트 식립 직후와 가장 최근 내원 시의 치근단 방사선 사진을 비교하였으며 Emago advanced v5.6 (Oral diagnostic systems, Amsterdam, Netherlands) 프로그램을 사용하여 임플란트 변연골 소실량을 측정하였다. 골 이식 유무가 임플란트 주위 변연골 소실에 미치는 영향을 알아보기 위하여 Window용 SPSS 프로그램을 이용한 독립표본 t 검정을 시행하였다. 결과: 환자 52명에서 83개 임플란트(골 이식 없이 식립된 임플란트 44개, 골 이식과 동시에 식립된 임플란트 39개)를 대상으로 6 - 45개월(평균 18.4개월)동안 관찰한 결과 골 이식 없이 식립된 임플란트는 $1.42{\pm}0.42mm$, 골 이식과 동시에 식립된 임플란트는 $1.28{\pm}0.45mm$의 변연골 소실을 보였다. 결론: 본 연구의 한계 내에서, 골 이식과 동시에 식립된 임플란트의 변연골 소실량이 유의하게 적었다.

짧은 임플란트의 생존율과 변연골 흡수량에 관한 임상적 연구 (Clinical Study on the Survival Rate and Marginal Bone Resorption of Short Implants)

  • 명태수;정승현;김태영;김유리
    • 구강회복응용과학지
    • /
    • 제28권1호
    • /
    • pp.1-13
    • /
    • 2012
  • 짧은 임플란트는 상악동이나 하치조신경 등의 해부학적 구조물이 있거나 심한 치조골 흡수로 인해 제한적인 치조제 높이를 가지는 부위에서 사용되고 있다. 본 연구는 길이 10 mm 이하의 임플란트에서 임플란트의 길이, 직경, 식립 부위, 골이식술 유무, 보철물의 연결고정 유무가 임플란트의 생존율과 변연골 흡수에 미치는 영향을 알아보고자 하였다. 원광대학교 치과병원 임플란트센터에서 길이 10 mm 이하의 임플란트를 식립한 137명의 환자, 227개 임플란트를 대상으로 진료 기록부를 통해 임플란트의 길이, 직경, 식립 위치, 골이식 유무, 보철물의 연결고정 유무를 조사하였다. 변연골 흡수량은 Emago advanced v5.6(Oral diagnostic systems, Amsterdam, The Netherlands) 프로그램을 이용하여 측정하였다. 총 227개의 임플란트 중 8개가 실패하여, 전체 짧은 임플란트의 생존율은 96.5 %로 나타났다. 골이식 부위와 상악에 식립된 경우 더 높은 실패율을 보이는 경향이 있었으며, 임플란트의 길이와 직경은 변연골 흡수량에 영향을 미치지 않았다. 실패 요인을 조사하였을 때, 상악의 불량한 골질과 골이식 유무가 임플란트의 더 높은 실패율에 영향을 미쳤다. 10 mm 이하 임플란트에서 길이, 직경, 식립 부위, 골이식술과 보철물의 연결 고정은 임플란트 생존율과 변연골 흡수량에 영향을 끼치지 않았다.

Effectiveness of digital subtraction radiography in detecting artificially created osteophytes and erosions in the temporomandibular joint

  • Kocasarac, Husniye Demirturk;Celenk, Peruze
    • Imaging Science in Dentistry
    • /
    • 제47권2호
    • /
    • pp.99-107
    • /
    • 2017
  • Purpose: Erosions and osteophytes are radiographic characteristics that are found in different stages of temporomandibular joint (TMJ) osteoarthritis. This study assessed the effectiveness of digital subtraction radiography (DSR) in diagnosing simulated osteophytes and erosions in the TMJ. Materials and Methods: Five intact, dry human skulls were used to assess the effectiveness of DSR in detecting osteophytes. Four cortical bone chips of varying thicknesses (0.5 mm, 1.0 mm, 1.5 mm, and 2.0 mm) were placed at the medial, central, and lateral aspects of the condyle anterior surface. Two defects of varying depth (1.0 mm and 1.5 mm) were created on the lateral, central, and medial poles of the condyles of 2 skulls to simulate erosions. Panoramic images of the condyles were acquired before and after artificially creating the changes. Digital subtraction was performed with Emago dental image archiving software. Five observers familiar with the interpretation of TMJ radiographs evaluated the images. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic accuracy of the imaging methods. Results: The area under the ROC curve (Az) value for the overall diagnostic accuracy of DSR in detecting osteophytic changes was 0.931. The Az value for the overall diagnostic accuracy of panoramic imaging was 0.695. The accuracy of DSR in detecting erosive changes was 0.854 and 0.696 for panoramic imaging. DSR was remarkably more accurate than panoramic imaging in detecting simulated osteophytic and erosive changes. Conclusion: The accuracy of panoramic imaging in detecting degenerative changes was significantly lower than the accuracy of DSR (P<.05). DSR improved the accuracy of detection using panoramic images.