• 제목/요약/키워드: Elutriation Rate

검색결과 12건 처리시간 0.035초

석탄유동층연소로에서 분진 발생 및 배출 특성 (Elutriation and Production of Fines in a Fluidized Bed Coal Combustor)

  • 장현태;이종일
    • 한국안전학회지
    • /
    • 제11권2호
    • /
    • pp.96-101
    • /
    • 1996
  • The effects of coal type and mixing fraction of coal on attrition and elutriation were studied in a 15. 5cm diameter fluidized bed coal combustor. The domestic low-grade anthracite coal with heating value 2010kcal/kg and the imported bituminous coal from Australia with heating value of 6520kcal/kg were used as coal sample. It was found from the experimental that the elutriation rate inclosed with an increseing anthracite mixing fraction. The size of elutriated particle had a very wide distribution was found in this experiment. The mean size of elutriated particle increased with decreaseing anthracite mixing fraction.

  • PDF

X-정자와 Y-정자의 분이에 관한 연구 III. Sephadex Gel 여과에 의한 우정자의 분이 (Separation of X- and Y-Bearing Spermatozoa III. Separation of bull spermtozoa by Sephadex Gel Filtration)

  • 이주영;엄기붕;고대환;김종배;정길생
    • 한국가축번식학회지
    • /
    • 제12권1호
    • /
    • pp.24-30
    • /
    • 1988
  • These experiments were carried out to develop new techniques for In Vitro separatin of X-and Y-bearing spermatozoa. The bull semen was applied to the various Gel-Columns filled with swellen Sephadex G-50 Fine and then elutriated wtih Locke solution (elutriation rate; 1ml/3-4min., 1ml/1-2min.). Elutriated solution was fractionated into 1ml by automatic Fraction Collector and spermatozoa included in each fraction were subjected to the estimation of viability and recovery rate, and to B-body test. The results obtained in these experiments were summarized as follows: 1. When the column size and the elutriation rate were adjusted to 15$\times$1.6cm and 1ml/3-4min., respectively, the highest sperm concentration was obtained from the 8th to the 12th fraction. 2. As a trend, the viability of spermatozoa was improved by chromatography, and the degree of improvement ranged 5 to 10 percentage. 3. The average recovery rate of spermatozoa applied to column was 73.2 percentage and ranged 52.6 to 81.3 percentage. 4. The lowest rate of B-body bearing spermatozoa following chromatography was obtained when the column size and the elutriation rate were adjusted to 15$\times$0.8cm and 1ml/1-2min., respectively.

  • PDF

돈사폐수의 세정산발효시 온도와 전처리의 영향 (Effect of Temperature and Pre-treatment for Elutriated Acidogenic Fermentation of Piggery Waste)

  • 배진연;민경석
    • 한국물환경학회지
    • /
    • 제21권1호
    • /
    • pp.34-39
    • /
    • 2005
  • The performance of elutriated acid fermentation with slurry-type piggery waste was investigated, especially to evaluate the effects of temperature and pre-treatment. In the first phase, the acid elutriation reactor with piggery waste after centrifugation operated at both mesophilic and thermophilic conditions to evaluate the effect of temperature. Solubilization yield($gVFAs/gSCOD_{prod.}$) and acidification rate($gVFAs/gSCOD_{prod.}$) in the thermophilic digestion were 0.45 and 0.55, which were higher than those of the mesophilic digestion, 0.25 and 0.45. In addition, the acid elutriation reactor at thermophilic temperature is more effective in removing e-coli. In the second phase, the acid elutriation reactor was fed with piggery waste before centrifugation. With piggery wastes before centrifugation, the solubilization yield and the acidificaton rate were 0.40 and 0.80, respectively, which were higher than the rates using piggery waste after centrifugation at both mesophilic and thermophilic conditions. The higher sludge volume reduction of 80% benefits sludge management. Furthermore, economical advantages can be achieved by removing the pre-treatment process, such as centrifugation. Consequently, the treatment with piggery waste before centrifugation proved to be effective. Also, the optimum temperature condition was estimated at mesophilic or thermophilic conditions, considering solubilization yields and acidification rates, though the system should be heated.

기-고 유동층에서 Gaussian 분포 입자군의 표준편차에 따른 유출 특성 (The Characteristics of Elutriation with Gaussian Particle Size Distributions in a gas-solid fluidized bed)

  • 장현태;차왕석
    • 한국산학기술학회논문지
    • /
    • 제10권11호
    • /
    • pp.3274-3279
    • /
    • 2009
  • 기-고 유동층에서 다입자경 입자의 입자분포 변화에 따른 비산유출 특성을 연구하였다. 다입자경 입자분포는 Gaussian 분포를 사용하여 실험을 수행하였다. 최소유동화속도에 대한 유속비와 Gaussian 입자분포의 표준편차에 따른 비산유출상수를 구하였으며, 이때 조업시간에 따른 압력요동의 특성치를 구하였다. 측정된 유동층의 압력요동 특성치로부터 압력요동의 표준편차, 평균압력, Power spectrum density function, 주진동수 등을 계산하였다. 입자분포군에 따라서 유출입자의 입자분포 및 압력요동 특성치는 크게 영향을 받는 것으로 나타났으며 이러한 결과로부터 압력요동 특성치로부터 유출특성의 해석이 가능함을 알 수 있었다.

유동층 연소로에서 유$cdot$무연탄 혼합 연소시 대기오염물질 배출에 관한 연구 (A Study on Contaminant Emission and Combustion of Anthracite-Bituminous Coal Blend in a Fluidized Bed Coal Combustor)

  • 조상원;정종현;손병현;김영식;오광중
    • 한국환경보건학회지
    • /
    • 제22권3호
    • /
    • pp.28-36
    • /
    • 1996
  • The objects of this study were to investigate emissions of air pollutant the particles as well as the combustibility of the low grade domestic anthracite coal and imported high-calorific bituminous coal in the fluidized bed coal combustor. The production of air pollution from anthracite-bituminous coal blend combustion in a fluidized bed coal combustor was evaluated. The effects of air velocity and anthracite fraction on the reaching time of steady state condition was also evaluated. We used coal samples the domestic low grade anthracite coal with heating value of 2,010 kcal/kg and the imported high grade bituminous coal with heating value of 6,520 kcal/kg. The experimental results are presented as follows. The time of reaching to steady state was affected by the temperature variation. The steady state time was about 120 minute at 0.3 m/s which was the fastest. It has been found that $O_2$ and $CO_2$ concentration were reached steady state at about 100 minute. As the height of fluidized bed becomes higher, the concentration s of $SO_2$ and $NO_x$ mainly increased. The concentration of freeboard was the highest and emission concentration was diminished. Also, as anthracite fraction increased, the emission of $SO_x$ concentration was increased. But, it has been found that the variation of $NO_x$ concentration with anthracite fraction was negligible and the difference of emission concentration according to air flow rates was negligible, too. It has been found that $O_2$ concentration decreased and $CO_2$ concentration increased as the height of fluidized bed increased. As anthracite fraction increased, the mass of elutriation particles increased, and $CO_2$ concentration decreased. Also, as air velocity increased, $O_2$ concentration decreased and $CO_2$ concentration increased. Regardless-of anthracite fraction and flow rate, the combustible weight percentage in elutriation particles were high in the case of fine particles.

  • PDF

유동층 연소로에서 유.무연탄 혼합 연소법을 이용한 국내산 저질 무연탄의 활용에 관한 연구 (A Study on the Use of Low-Grade Domestic Anthracite by Anthracite - Bituminous Coal Blend Combustion in a Fluidized Bed Combustor)

  • 정종현;조상원
    • 한국환경과학회지
    • /
    • 제6권3호
    • /
    • pp.267-276
    • /
    • 1997
  • It has been studded that combustion and the production of air pollution of anthracite - bituminous coal blend In a fluidized bed coal combustor, The objects of thIns study were to investigate mixing characteristics of the particles as well as the combustibility of the low grade domestic anthracite coal and Imported h19h calorific bltununous coal in the fluidized bed coal combustor. They were used as coal samples ; the domestic low grade anthracite coal with heating value of 2,010kca1/kg and the Imported high grade bituminous coal with beating value of 6,520kca1/kg. Also, the effects of air flow rate and anthracite fraction on the reaching time of steady state condition have been studied. The experimental results are presented as follows. The time of reaching to steady state was affected by the temperature variation. The steady state time was about 120 minute at 300sc1h which was the fastest. It has been found that $O^2$ and $CO^2$ concentration were reached steady state at about 100 minute. It has been found that $O^2$ concentration decreased and $CO^2$ concentration increased as the height of fluidlzed bed Increased. It was found that splash zone was mainly located from 25cm to 35cm above distributor. Also, as anthracite traction Increased, the mass of elutrlatlon particles Increased, and $CO^2$ concentration decreased. As gk flow rate Increased,$O^2$ concentration decreased and $CO^2$ concentration increased. Regardless of anthracite fraction and flow rate, the uncombustible weight percentage according to average diameter of elutriation particles were approldmately high In the case of One Particles. As anthracite traction and k now rate Increased, elutriation ratio Increased. As anthracite fraction was increased, exit combustible content over feeding combustible content was Increased. Regardless of anthracite fraction, size distribution of Ued material from discharge was almost constant. Over bed temperature 85$0^{\circ}C$ and excess air 20% , the difference of combution efficiencies were little. It is estimate that the combustion condition In anthracite-bituminous coal blend combustion is suitable at the velocity 0.3m/s, bed temperature 85$0^{\circ}C$, the excess air 20%.

  • PDF

유동층을 이용한 유,무연탄 혼합 연소로에서 대기오염물질 생성과 연소효율 연구 (A Study on Production of Air Pollutants and Combustion Efficiency of Anthracite-Bituminous Coal Blend Combustor Using Fluidized Bed)

  • 조상원;민병철
    • 공업화학
    • /
    • 제8권3호
    • /
    • pp.517-523
    • /
    • 1997
  • 본 연구는 유동층연소로에서 유,무연탄 혼합연소시 대기오염물질 발생과 연소효율에 관하여 실험하였으며, 실험결과는 다음과 같다. 유동층연소로 높이가 증가할수록 이산화황과 질소산화물의 농도는 증가하는 것으로 나타났으며, 무연탄 혼합비가 증가할수록 이산화황의 농도는 증가하였으나 질소산화물농도는 큰 변화가 없었다. 무연탄 혼합비가 증가할수록 비산유출율도 증가하였고 주입 가연성분에 대한 유출 가연성분비도 증가하였다. 또한, 무연탄 혼합비에 관계없이 비산유출입자의 평균입경에 따른 미연분 함량은 미세입자에서 대체로 높게 나타났다. 한편, 연소효율은 층온도 $850^{\circ}C$, 과잉공기 20% 이상에서 큰 차이를 보이지 않았으므로 유속 0.3m/s, 층온도 $850^{\circ}C$, 과잉공기비 20%의 조건으로 혼합연소시키는 것이 적절한 것으로 나타났다.

  • PDF

원추형 분립유동층에서 미세 분체의 수력학적 특성 (Hydrodynamic Characteristics of Fine Powders in the Conical Powder-Particle Fluidized Beds)

  • 이동현;신문권;김은미;손승용;박병섭;한귀영;윤기준
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.310-313
    • /
    • 2005
  • The conical fluidizing system of a binary mixture of Geldart C powders and Geldart A particles was defined as the conical powder-particle fluidized bed. We used a cold conical powder-particle fluidized bed model having a 0.104m-I.D. and 0.6m-high with an apex angle of $10^{\circ}$ for fluidization of a binary powder-particle mixture of 50 $vol\%$ fine carbon black powders (HI-900L, Korea Carbon Black Co.) and coarse alumina particles $(90{\mu}m)$ under different superficial gas velocities (0-0.1 m/s). The differential bed pressure drop increases with increasing gas velocity, and it goes from zero to a maximum value with increasing or decreasing gas velocity. In the conical fluidized beds of fine powders, demarcation velocities of the partial fluidization, full fluidization, partial defluidization was not observed.

  • PDF

유동층반응기에서 촉매를 이용한 메탄 열분해 (Thermal Decompostion of Methane Using Catalyst in a Fluidized Bed Reactor)

  • 장현태;이지윤;차왕석
    • 한국산학기술학회논문지
    • /
    • 제9권2호
    • /
    • pp.487-492
    • /
    • 2008
  • 본 논문은 유동층반응기에서 메탄 열분해에 의한 수소 생산과 탄소 생성에 대한 연구를 수행하였다. 환경에 대한 영향을 최소화한 상태에서 one-step에 의한 메탄의 전환반응을 메탄 분해촉매활성에 영향을 미치는 인자에 대하여 연구하였다. 측정된 압력요동특성치의 해석을 통하여 유동층 열분해촉매의 유동화현상을 측정하였으며, 유동화특성에 따른 메탄열분해능을 측정하였다. 메탄의 분해능는 생성되는 수소의 농도로부터 측정하였다. 유동층의 특성인 층내 입자 이동성, U-Umf, 마모, 비산유출, 유동화가스의 효율밀도에 따른 분해효율에 미치는 영향을 고찰하였다.

혐기성 소화조 오니의 탈수에 대한 요인분석 (A Study on Dewatering Characteristics of Anaerobic Digested Sludges)

  • 팽종인
    • 한국환경보건학회지
    • /
    • 제8권2호
    • /
    • pp.13-31
    • /
    • 1982
  • Factors affecting on dewatering characteristics of anaerobically digested or/and elutriated sludges were examined from 15 January 1982 to 30 April 1982, results obtained were as follows 1. Sludges, either anaerobically digested or/and elutriated sludges, which were produced at the Joong Rang Cheon Sewage Treatment Plant wore found to be compressive in its nature, coefficient of compressibility ranged from 0.83 for unelutriated and 1.10 for elutriated. 2. Dosage of FeC13 for the anaerobically digested sludges were difficult to establish for the most favorable dosage rate, though the filterability indicated linear improvement with increased dosage from dosing rate excess of over 15% in terms of dry solids by weight, under the conditions of this examination. Optimum filterability were obtained with 9~11% of $FeCl_3$ for elutriated sludges, and required CaO, as aids, were appeared to be 2.5~3.5 times that of the $FeCl_3$ at that point by weight. 3. The specific resistances for anaerobically digested sludges showed higher value than the elutriated one, being $11 \times 10^{12} ~ 20 \times 10^{12}$ cm/g with no chemical conditioning, and $2 \times 10^{12} ~ 11 \times 10^{12}$ cm/g with conditioned ($FeCl_3$ + CaO) contrast to $0.5 \times 10^{12} ~ 2.0 \times 10cm/g$ for the elutriated. 4. The strength of the alkalinities before and after elutriation were measured to 10,000 ~ 15,000 mg/l and 1,500 ~ 2,000mg/l respectively. These alkalinities affected greatly on the filterabilities together with concentration of the organic matters in the sludges. 5. The yields with 11% $FeCl_3$, by weight to the DS, on the elutriated sludges averaged to $14.7 kg/m^2.hr$, and $3.2kg/m^2.hr$ for unelutriated sludges. Which was 4.6 times of not elutriated sludges. Elutriated sludges without chemical conditioner added showed much better filterabilities than with 15% of $FeCl_3$ added to the anaerobically digested and unelutriated sludges.

  • PDF