• Title/Summary/Keyword: Eliminator

Search Result 47, Processing Time 0.043 seconds

Determining Factors to Enhanced Oil Mist Filter Efficiency Using CFD Modeling (CFD모델링을 통한 오일 미스트필터효율 향상 결정요소에 관한 연구)

  • Shin, Hee-Jae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.10
    • /
    • pp.119-127
    • /
    • 2021
  • Small drops in gas cause some problems for downstream equipments such as turbine, compressor and etc. In some cases, we are obliged to remove hazardous liquid mist from gas. In order to remove water or other liquids from the gas, there are some equipments like mesh mist eliminator and vane-plate mist eliminator. oil mist filter is a kind of liquid eliminator equipments used to remove the liquid with 1-10um droplet diameter from the gas. In this paper is determine the factors affecting the oil mist filter efficiency using CFD. length and angle of the filter were considered and the results and compare the results of the efficiency tests, showed error of less than 3%. optimum filter can remove more than 87.3% between 1 and 10um of oil mist.

Computational Analysis on the Control of Droplet Entrained in the Exhaust from the Spray Type Scrubber system (스프레이형 스크러버의 배출가스에 포함된 액적의 제어방법에 관한 전산해석적 연구)

  • Lee, Chanhyun;Chang, Hyuksang;Koo, Seongmo
    • Clean Technology
    • /
    • v.21 no.3
    • /
    • pp.191-199
    • /
    • 2015
  • The SOx emission from the ship diesel engines will do a negative influence to the human health and the environment. To reduce the negative environmental effect of the SOx emission caused by the high traffic of ship movements, the SECA (SOx emission control area) has been set on several province around world to carry out the severe emissions control and to meet the emissions control standard. To cut down the SOx emission from the ships, the wet type scrubber is being used widely. In this work, we prepared a numerical model to simulate the spray type scrubber to study the motion of liquid droplets in the flow of the scrubber. For the analysis, the CFD (computational fluid dynamics) method was adopted. As a special topic of the study, we designed the wave plate type of mist eliminator to check the carry over of the uncontrolled water droplet to the exhaust. Numerical analysis is divided into two stages. At the first stage, the analysis was done on the basic scrubber without the mist eliminator, and then the second stage of analysis was done on the scrubber with the mist eliminator on several condition to check and compare with the basic scrubber. On the condition of the basic scrubber, 42.0% of the distributed water droplets were carried over to the exhaust. But by adding the designed droplet eliminator at the exhaust of the scrubber, only 3.4% of the distributed water droplets supplied to the scrubber was emitted to the atmosphere.

Shape Optimization of a Thomson coil Actuator of Arc Eliminator Using Topology Modification (Topology Modification을 이용한 Thomson coil Actuator의 형상 최적화)

  • Li, Wei;Jeong, Young-Woo;Koh, Chang-Seop
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.774_775
    • /
    • 2009
  • The shape optimization of a Thomson coil actuator used in an arc eliminator is done for fast response by adopting topology modification method. The performance of the actuator is analyzed by using an equivalent circuit method. Both shape optimization and performance analysis are accomplished based on the segmentation of plate. The effectiveness of the proposed method is proved by the comparison of results before and after the shape optimization.

  • PDF

Dynamic Characteristics Analysis of High Speed Thomson-coil Arc Eliminator Using Equivalent Electric Circuit Method with Adaptive Segmentation of conducting Plate

  • Li, Wei;Lu, Jiang;Jeong, Young-Woo;Koh, Chang-Seop
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.90-92
    • /
    • 2008
  • A novel solving technique has been developed to analyze the dynamic characteristics of high speed Thomson-coil arc eliminator. The electromagnetic repulsion actuator based on Thomson-coil is taken as the driving part of the arc eliminator, due to which, the opening and closing time is quite short compare to other type actuators. The electromagnetic repulsion actuator is composed of one repulsion plate and two fixed coils, corresponding to the opening coil and closing coil, respectively. The new solving technique is derived based on the equivalent electric circuit model of the system which is set up by dividing the repulsion plate into multi segments using adaptive segmentation method. This solving technique is applied to the dynamic characteristic analysis of electromagnetic repulsion actuators in high speed Thomson-coil arc eliminators. The calculation results are testified by the FEM calculation results and experiment results.

  • PDF

Analysis of Parameters Influence on the Characteristics of Thomson Coil Type Actuator of Arc Eliminator Using Adaptive Segmentation Equivalent Circuit Method

  • Li, Wei;Jeong, Young-Woo;Yoon, Hee-Sung;Koh, Chang-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.282-289
    • /
    • 2010
  • A Thomson coil type actuator is applied as the driving unit in an arc eliminator system. To eliminate the arc efficiently, the speed of the actuator is required as fast as possible with certain limit of the exciting current. Therefore, the dynamic characteristics of the Thomson coil type actuator should be analyzed in an effective way. In this paper, a novel solving technique has been developed based on the equivalent circuit model which is set up by dividing the conducting plate into multi segments. To guarantee the calculation accuracy and improve the calculation efficiency, an adaptive refinement algorithm is suggested based on the field continues condition. The proposed method has been verified by the FEM calculation and experiment. The influence of circuit and plate parameters to the performance of the actuator is also investigated, from which a reasonable set of parameters can be found.

An Optimal Design Strategy for a Thomson Coil Actuator

  • Lim, Dong-Kuk;Jung, Sang-Yong;Jung, Hyun-Kyo;Ro, Jong-Suk
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.182-188
    • /
    • 2017
  • An arc eliminator allows a surge current bypass rapidly into the earth to facilitate the circuit breaking process and increase the stability of the load circuit. Thomson coil actuator (TCA) is a type of actuator that can function as an arc eliminator. The TCA has a simple structure and significantly rapid speed compared to the other types of actuators. In this paper, significant variables, which have a dominant effect on the performance of the TCA, are investigated in detail. Using these variables and an optimization algorithm, an optimal design strategy for the TCA is proposed in this research. The efficacy of the proposed optimal design strategy and the feasibility of the application of the designed TCA for a high power circuit breaker as the arc eliminators are validated through the experiment.

Pressure Drop and Refrigerant-Entrainment Characteristics of the Eliminators used in Absorption Chillers (흡수식 냉동기용 엘리미네이터의 압력손실 및 액적유입 특성)

  • 정시영;류진상;이상수;이정주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.109-115
    • /
    • 2003
  • The performance of two vertical-blade eliminators (V1, V2) and two horizontal-blade ones (H1, H2) for absorption chillers were tested in terms of pressure drop and refrigerant entrainment. The test was carried out using a wind tunnel with a cross section of 300 mm$\times$300 mm. The pressure drop of four eliminators tested was found to be in the rage of 1.0~2.7mm $H_2O$ at the face velocity of 2m/s. In the refrigerant entrainment test the vertical-blade eliminators showed much better performance than the horizontal-blade ones. The horizontal-blade eliminators showed satisfactory results at the air velocity of 2m/s but exceeded the limit value at 3 m/s. Since the cooling capacity of a machine is lowered by about 2.5% at the pressure drop of 1 m $H_2O$, more researches are required to reduce the pressure drop in the eliminator.

The localization technical development of Wire-Mesh Type system for Hydrocarbon Mist Gas/Liquid separation (Hydrocarbon Mist 기/액 분리를 위한 Wire-Mesh Type 시스템 국산화 기술개발)

  • Kang, Seung-Jin;Park, Chi-Kyun;Kil, Sung-Jae;Lee, Man-Sik
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12a
    • /
    • pp.349-352
    • /
    • 2011
  • 본 연구를 통해 개발하고자 하는 Wire-Mesh Type Mist Eliminator는 탄화수소(Hydrocarbon)를 취급하는 석유화학 공정 내에서 Vapor 중에 존재하는 $10{\mu}m$ 이하크기의 미세한 액체 Mist를 분리하는데 사용되는 화학 공정플랜트 요소부품이다. 석유화학 공정에서 발생되는 $5{\mu}m$이하의 크기를 가지는 액체 Mist를 제거하기 위해서는 Stainless와 Polypropylene 재질이 혼합된 새로운 WMT Mist Eliminator 국산화 제품개발 시급하다. 실험을 통해 확보한 인자를 바탕으로 제작된 시제품의 분석결과 석유 화학공정에 이용이 가능한 것을 확인하고 성능이 우수함을 알 수 있었다.

  • PDF

Performance Evaluation of Manhole Filter to Remove Odor Inside Sewage Pipe -Focused on Removal of Hydrogen sulfide- (하수관거 악취 제거를 위한 맨홀필터 악취제거장치 성능 평가 - 황화수소 제거를 중심으로 -)

  • Kim, Choong-Gon;Lee, Jang-Hown
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.4
    • /
    • pp.45-51
    • /
    • 2018
  • The objective of this study is to evaluate the applicability of a manhole-filter odor eliminator that is installed on a manhole to remove hydrogen sulfide ($H_2S$) contained in the sewage of urban streets; $H_2S$ is the very cause of offensive odor from such sewage. An analysis of the capability of impregnated activated carbon, which is contained in the manhole filter, to adsorb hydrogen sulfide shows that some 99.8% of hydrogen sulfide can be removed. A performance evaluation of the manhole-filter odor eliminator, which was made on Manhole Section 4 known as the representative malodorous manhole section of Seoul, Korea, indicates that more than 97% of hydrogen sulfide ($H_2S$), one of typical malodor-generating substances, can be eliminated. The results and findings of the study as described above suggest that the applicability of the manhole-filter odor eliminator to eliminate offensive odor generated from sewer manholes is satisfactory.

Studies on the Heavy Metals Elimination and Antioxidation of the Onion Ethnolic Extract (양파 알코올 추출물의 항산화 효과 및 중금속 제거 가능성 연구)

  • Lee, Mi-Kyung;Chung, Young-Hee;Nam, Hyun-Keun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.143-146
    • /
    • 1999
  • In order to study for Onion ethanolic extract on the Heavy Metal Elimination and antioxidation, the peroxide values of oil and eliminated metal were analyzed. The results are follows: It was very effective as a retardant for autoxidation processing of the soybean and olive oil by the Onion ethanolic extract. Quercetin in the Onion ethanolic extract was affected as a ligand for chelating with some metals. Through out this study, Quercetin in the Onion ethanolic extract was affected as eliminator of the Mercury, Lead, and Cadmium.Abstracts In order to study for Onion ethanolic extract on the Heavy Metal Elimination and antioxidation, the peroxide values of oil and eliminated metal were analyzed. The results are follows: It was very effective as a retardant for autoxidation processing of the soybean and olive oil by the Onion ethanolic extract. Quercetin in the Onion ethanolic extract was affected as a ligand for chelating with some metals. Through out this study, quercetin in the Onion ethanolic extract was affected as eliminator of the mercury, lead, and cadmium.