• Title/Summary/Keyword: Elevator hall

Search Result 30, Processing Time 0.026 seconds

DEVELOPMENT OF EMEVATOR GROUP SUPERVISIRY SYSTEM WITH FUZZY MADE

  • Park, Hee-Chul;Lee, See-Hun;Choi, Don;Woo, Kwang-Bang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.390-394
    • /
    • 1994
  • A elevator group supervisory system is designed to perform efficient operation of multiple elevators, and its basic function is to assign an appropriate elevator to a given hall-cell. In this paper, in order to improve elevator group control performance, we propose a new dispatching system which includes fuzzy multi-attribute decision making(MADM). In most cases, the purpose of group control is to maximize control goals as much as possible. Unfortunately, the decision of optimal elevator to a given hall cell is made with very uncertain information of the system, and some of control goals are related each other. The uncertainty is mainly resulted from car calls generated by serving hall calls. A fuzzy MADM algorithm is proposed to deal with these problems to improve system performance.

  • PDF

A study on Elevator Group Controller of High Building using Adaptive Dual Fuzzy Algorithm (Adaptive Dual Fuzzy 알고리즘을 이용한 고층 빌딩의 엘리베이터 군 제어에 관한 연구)

  • Choi, Seung-Min;Kim, Hum-Mo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.4
    • /
    • pp.112-120
    • /
    • 2001
  • In this paper, the development of a new group controller for high-speed elevator is carried out utilizing the approach of an adaptive dual fuzzy logic. Some goals of control are the minimization of waiting time, mean-waiting time and long-waiting time in a high building, when a new hall call is generated, adaptive dual fuzzy controller evaluate traffic pattern and change appropriately the membership function of a fuzzy rule base. Controls for co-operation among elevators in a group control algorithm arte essential, and the most critical control function in the group controller is an effective and proper hall call assignment of elevators. The group elevator system utilizing adaptive dual fuzzy control reveals a great deal of improvement on its performance.

  • PDF

Condensation Reduction Study of an Apartment Underground Elevator Hall with respect to Dehumidifier Locations (제습기 설치 위치에 따른 공동주택 지하 엘리베이터홀의 결로 저감 연구)

  • Park, Jong-Jun;Kim, Young-Il;Kim, Jong-Yeob;Kim, Gil Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.4
    • /
    • pp.169-174
    • /
    • 2014
  • Computational fluid dynamics simulation of an apartment underground elevator hall has been carried out to study the effect of dehumidifier locations on condensation problem. In Case 1, horizontal position of humidifier is studied. It is installed at entrance, center or the inside of the elevator hall. In Case 2, installation height is studied, one at 0 m and the other at 1.6 m above the floor. In Case 3, exposed and embedded dehumidifiers are compared for performance. The study shows that the entrance, top and exposed locations are more effective in reducing condensation.

A Design for Elevator Group Controller of Building using Adaptive Dual Fuzzy Algorithm (Adaptive Dual Fuzzy 알고리즘을 이용한 빌딩의 엘리베이터 군 제어기 설계)

  • 최승민;김훈모
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.578-581
    • /
    • 2001
  • In this paper, the development of a new group controller for high-speed elevator is carried out utilizing approach of an adaptive dual fuzzy logic. A goals of control are the minimization of waiting time, mean-waiting time and long-waiting time in a building. when a new hall call is generated, adaptive dual fuzzy controller evaluate traffic pattern and change appropriately the membership function of fuzzy rule base. Control for co-operation among elevators in group control algorithm are essential, and the most critical control function in group controller is a effective and proper hall call assignment of elevators. Thy group elevator system utilizing adaptive dual fuzzy control reveals a great deal of improvement on its performance.

  • PDF

A Simulation of Elevator Group Controller using Adaptive Dual Fuzzy Algorithm (Adaptive Dual Fuzzy 알고리즘을 이용한 엘리베이터 군 제어 시뮬레이션)

  • 최승민;김훈모
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.157-160
    • /
    • 2000
  • In this paper, the development of a new group controller for high-speed elevator is carried out utilizing approach of an adaptive dual fuzzy logic. A goals of control are the minimization of waiting time, mean-waiting time and long-waiting time in a high building, when a new hall call is generated, adaptive dual fuzzy controller evaluate traffic pattern and change appropriately the membership function of fuzzy rule, base. Control for co-operation among elevators in group control algorithm are essential , and the most critical control function in group controller is a effective and proper hall call assignment of elevators. The group elevator system utilizing adaptive dual fuzzy control reveals a great deal of improvement on its performance.

  • PDF

Timed Petri Net Based Approach for Elevator Group Controls

  • Cho, Young-Cheol;Zavarin Gagov;Kwon, Wook-Hyun
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.2 no.2
    • /
    • pp.121-129
    • /
    • 2000
  • In this paper, an optimal group control for elevator systems is proposed with timed Petri net based approach. Elevator system is modeled by time Petri nets and hall call response times are estimated with moment generating functions (MGFs) methos, which is applicable to real traffic patterns. Two assignment policies are proposed to satisfy the demands of passengers(i.e. hall/car calls) and to handle exceptional situations. In addition, optimal algorithms are implementated to minimize cost functions. THe performances of the elevator system employing the proposed algorithms are compared with each others in ways of several performance measures by a computer simulation.

  • PDF

An Experimental Study on Ventilation of Connection Passage and Elevator Hall of Underground Parking in the Apartment Houses (공동주택의 지하주차장 연결통로 및 엘리베이터 홀의 환기에 관한 실험적 연구)

  • Kim, Il-Gyoum;Park, Woo-Cheul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1523-1528
    • /
    • 2008
  • In this study, the ventilation system of connection passage and elevator hall of underground parking lot in apartment houses is investigated to extract the data for the installation and the application by the experimentation. In case of the elevator hall, actual air exchange rate is predicted fivefold higher than air exchange rate by infiltration and exfiltration. Ventilation system is installed good by supply air and return air. As the next best thing, it is installed by supply air because of IAQ control. The temperature of connection passage and elevator hall uniformly with $7{\sim}8^{\circ}C$, is maintained even if the operating condition of ventilation system is different. Therefore, the installation of the preheater, which is installed at the inlet of ventilation system for the cold draft in winter, is not essential in southern area of Korea.

Development of Nondestructive Detecting System for Elevator Wire Ropes using Hall-effect Sensors (Hall 센서를 이용한 엘리베이터 와이어 로프의 비파괴 검출시스템의 개발)

  • Kim, Sung-Duck
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.33-41
    • /
    • 2001
  • Wire ropes have been widely used in industrial applications, wherever heavy weight should be carried safely or mechanical energy should be transmitted fast. Especially, wire rope failures in operating elevator may lead to extensive property damage and serious injury to nearby personnel. Hence, it is very important to inspect wire rope periodically. Failure defection of wire rope requires fundamental knowledge of wire rope construction, rope behavior, properties of fault, sensing and signal processing method. In this research, the development of a new fault detecting system incorporating Hall-effect sensors to detect flaws such as abrasion, broken wire, corrosion and deformation for aged wire ropes in elevator, is described. For using a detector as a portable instrument, several performances for implementing sensing part with Hall-effect sensor, analog signal processing unit and programs are described. Experiments and field testing results for the implemented detecting system are also given. As a result, it is verified that the detecting system has good efficiency for inspecting faults of aged wire ropes in service.

  • PDF

A Study on the Distributed Control Modeling of Elevator (엘리베이터의 분산 제어 모델링에 관한 연구)

  • Cho, Myug-Hyun;Lee, Myung-Un
    • 전자공학회논문지 IE
    • /
    • v.44 no.4
    • /
    • pp.35-40
    • /
    • 2007
  • Recently, buildings are constructed increasingly higher and even more people are using elevators every day. Therefore, more efficient means of vortical transportation are required. Most of high-rise buildings is equipped with elevators. Unlike one elevator system, a multi-elevator system requires a function, which can distribute multiple elevators effectively. This paper examines a multi-elevator system, which has been modeling mathematically, in order to reduce waiting time and use elevators more effectively.

A predictive fuzzy control algorithm for elevator group control (엘리베이터 군제어를 위한 예견퍼지 제어알고리즘)

  • Choi, Don;Park, Ji-Hyun;Park, Hee-Chul;Woo, Kwang-Bang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.731-736
    • /
    • 1993
  • In this paper, a predictive fuzzy control algorithm to supervise the elevator system with plural elevator cars is proposed and its performance is evaluated. Elevator group controller must decide the service elevator for a registered hall call to satisfy the multiple control objects. The proposed group control algorithm ensures the efficient operations of the group cars and provides the improved level of service, coping with multiple control objects and uncertainty of system state. The feasibility of the proposed control algorithm is evaluated by simulation on computer.

  • PDF