• Title/Summary/Keyword: Elevator evacuation

Search Result 37, Processing Time 0.02 seconds

A Study on the Consideration Factors for the Calculation of Elevator Evacuation Time (엘리베이터 피난계산 고려인자에 관한 연구)

  • Kim, Hak-Joong;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.8-14
    • /
    • 2010
  • It is more important to study for reducing the evacuation time of occupant in fire, because the building has been taller and deeper. It has known that elevator was not safe in fire situation. So, the using elevator for evacuation has been prohibited. But the study of elevator evacuation is progressed with designing the elevator safe from flame and smoke. This study analyze the consideration factors for the calculation of elevator evacuation time. The factors for elevator evacuation calculation is starting time, round trip time. And round trip time is divided into standing time and travel time. The elevator evacuation time can be calculated by compounding these factors and adding the efficiency. For using elevator to evacuate, we need additional study for smoke control, compartment, water proof and safe electric power supply.

A Investigation Study on the Recommendation for the Evacuation Plan using Evacuation Elevator of AIJ (I) (일본건축학회의 화재 시 피난 엘리베이터를 이용한 피난계획 지침안(案)에 대한 조사 (I))

  • Kwon, Young-Jin;Yun, Yoo-Hyuk
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.3-6
    • /
    • 2008
  • Most elevators worldwide do not have smoke protection, fire protection, and other features necessary for them to be considered as a means of fire evacuation. It is the aim of this study to investigate and analyze the recommendation for the evacuation plan using evacuation elevator of AIJ the aim of this study is to introduce AIJ method for the safety plan using evacuation elevator of high rise building written by working group fire resistant.

  • PDF

Elevator evacuation studies using a computer program (컴퓨터프로그램을 이용한 엘리베이터 피난 연구)

  • Cha, Jong Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5525-5533
    • /
    • 2012
  • Because of ultra-high buildings or deeper underground space, recent buildings have the potential that people who have lack of physical strength collapse before arriving at the emergency exits when catastrophes occur. In case of fire, the way to escape is that first, people take the stairs of the adjacent areas and then use the elevator to the remaining distance by road to escape notice or be safe. For this reason, the skyscrapers guidelines of Seoul for information on the elevator for evacuation has been established. Nevertheless, when designing buildings to install a elevator for evacuation separately is not effective, so passenger elevators installation according to the criteria are encouraged to use as evacuation elevators. However, this does not include detailed design guidelines so far. Therefore, this study was to investigate design method to use the passenger elevator for evacuation according to the domestic law and international installation criteria, and to calculated number of lifts and refuge to use the elevator using by the ELVAC+ and PathFinder evacuation program.

A Investigation Study on the Recommendation for the Evacuation Plan using Evacuation Elevator of AIJ (II) (일본건축학회의 화재 시 피난 엘리베이터를 이용한 피난계획 지침안(案)에 대한 조사(II))

  • Lee, Jae-Won;Kim, Dong-Eun;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.316-321
    • /
    • 2008
  • Most elevators worldwide do not have smoke protection, fire protection, and other features necessary for them to be considered as a means of fire evacuation. It is the aim of this study to investigate and analyze the recommendation for the evacuation plan using evacuation elevator of AIJ the aim of this study is to introduce AIJ method for the safety plan using evacuation elevator of high rise building written by working group fire resistant.

  • PDF

A Study on the Necessity of Introducing Evacuation Instrument in High-rise Buildings - Focusing on Elevator Type Evacuation Instrument - (고층건축물의 피난기구 도입 필요성에 관한 연구 - 승강식피난기를 중심으로 -)

  • Choi, Kyu-Chool;Ra, Pan-Ju;Seul, Yeong-Mi
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.10-19
    • /
    • 2014
  • The fast evacuation from fire floors to evacuation floors in high-rise building fires can minimize the human damage. In this study, an evacuation instrument, which are applicable to the high-rise buildings of adaptable escape mechanisms by the current NFSC 301 (national fire safety code 301), were selected to analyze the applicability in the high-rise buildings over 11th floor through the site adaptability test. The results of the site test were as follows. The elevator type evacuation instrument of new concept developed as a new technology by compensating the defect of evacuation instrument limiting in the high-rise buildings over 11th floor had completed the stability test and the performance certification test in fire stations, which there were no problems in the introduction of the elevator type evacuation instrument as an escape mechanism in the high-rise buildings. The elevator type evacuation instrument using escapers' weight without using electric power was an escape mechanism that many people could evacuate in a short period of time when a fire broke out in the high-rise buildings. In particular, The elevator type evacuation instrument operated by nonpower had the adaptability as a customized escape mechanism considering user characteristics in the buildings for the disabled or patients with an advanced disease.

A study on the escape measures using fire fighters elevator (비상용승강기를 이용한 피난방안에 관한 연구)

  • Yoon, Woo-Jin;Sin, Tae-Gyun;Hong, Ji-Hoon;Cho, Won-Chul;Lee, Tae-Sik
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.640-644
    • /
    • 2007
  • The purpose of the present research is to provide a plan for an effective evacuation of residents and people who's in need of evacuation (such as children, the handicapped, and the old) and for the situation when staircase is not available for evacuation, by means of analyzing the evacuation behavioral characteristics of the residents or the evacuators and suggesting an evacuation plan using an emergency elevator in order to minimize casualties in case when fire broke out in a skyscraper.

  • PDF

Study on the Shortening Effect of the Egress Travel Time Based on an Escape Scenarios by Using Shuttle Elevators for Lotte Tall Building's Evacuation Plan (초고층건물 피난계획시 피난용 엘리베이터 이용에 의한 피난소요시간의 단축효과 연구)

  • Park, Hyung-Joo;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.46-54
    • /
    • 2018
  • A total of 19 elevators for evacuation were installed in the Lotte World Tower and it is planned to operate the shuttle using the manual key from five refuge floors to the 1st floor in an emergency. In the event of a fire or other disaster, it is necessary to conduct intensive analysis to determine how much RSET reduction could be achieved using the evacuation elevator compared to the existing evacuation plans. When the optimal transportation sharing ratio by the evacuation elevators was 40% at the Lotte World Tower, the RSET of the evacuation scenario in parallel with the elevators in the entire building was calculated to be 1 hour and 2 minutes. The RSET of a conventional evacuation scenario (Walking along the stairs without using the elevators) was calculated to be 1 hour 29 minutes, therefore, the former evacuation scenario were found to have a shortening effect of approximately 27 minutes compared to the latter. On the other hand, to maintain this effect, each part of the evacuation route using the elevator must have the capability to protect the evacuee from any hazards caused by fires, such as smoke, flame, and radiant heat during the evacuation. Moreover, the evacuation route should be continuous from the residence position of the elevator user to the final evacuation site, and be recognized easily.

A Study on the Estimation for the Flow Coefficient of Elevator Shaft (엘리베이터 샤프트의 유량계수 산정에 관한 연구)

  • Kim, Hak-Joong
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.2
    • /
    • pp.148-157
    • /
    • 2012
  • Recently, evacuation safety of building residents becomes the major concern, as the building has been higher and more complicated. Many high-rise multi use buildings are under construction in Korea. Required evacuation time using stairway is longer in high-rise buildings, moreover it is impossible for the disabled to evacuate by using stairway. For this reason the study on the effectiveness of using elevator for evacuation is being progressed. Elevator shaft flow coefficient is the major factor for the calculation of elevator piston effect. The results of this study can be used for the study of elevator piston effect as basic data. The flow coefficient simulation was performed using FLUENT, commercial CFD program. As a result of the flow coefficient simulation, the coefficient is 0.88 considering the safety factor. This result is verified that the result of experimental study, 0.86 is conservative.

An Experimental Study on the Pressure Change in the Type of Elevator Hoistways (엘리베이터 승강로 형식별 압력변동에 관한 실험 연구)

  • Kim, Hak-Joong;Kim, Boem-Gyu;Park, Yong-Hwan;Lim, Chae-Hyun
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.139-144
    • /
    • 2010
  • Recently, evacuation safety of building resident become the major concern, as the building has been higher and more complicated. Many high-rise multi use buildings are under construction in Korea. Required evacuation time using stairway is longer in high-rise buildings, moreover it is impossible for the disabled to evacuate by using stairway. For this reason the study on the effectiveness of using elevator for evacuation is progressing. This study shows the pressure change in various types of hoistway when elevator is moving. Experiments were performed in 4 different types of hoistway, and showed big difference in pressure change between the type of hoistway. The pressure change in single hoistway that have one car is bigger than that in multi hoistway that have multi cars. The results of this study can be used for the study of elevator piston effect as basic data.

A Study on the Improvement of the Evacuation in Ward of the General Hospital (종합병원 병동부 피난환경 개선에 관한 연구)

  • Kim, Woo-Seok;Chai, Choul-Gyun
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.5 s.58
    • /
    • pp.202-208
    • /
    • 2006
  • The purpose of this study is to suggest architectural planning guideline for the improvement of the evacuation environment in a ward. To suggest of guideline, the problem of irrational domestic criteria is searched according to compare National fire code (NFPA101, Life safety code) with Korea building law. This study includes stairs, corridors and exit door etc. but excludes fire facilities. To verify effectiveness of suggested guideline, egress simulation is run that based on databases according to literature survey. The results of this study could be summarized as follow: Suggested guidelines are subdivision(fire partition), evacuation by elevator, secure useful waiting space of elevator hall and smokeproof enclosures, the corridor is divided by fire or smoke barriers corridor from hazardous room, only wheeled items are arranged in corridors of a ward story. The result of computer simulation for suggested guidelines verify that egress time can be decreased 20% or above.