• Title/Summary/Keyword: Elemental Powder

Search Result 175, Processing Time 0.021 seconds

Synthesis and Characterization of La0.75Sr0.25FeO3 Used as Cathode Materials for Solid Oxide Fuel Cell by GNP Method (GNP법을 이용한 고체산화물 연료전지의 공기극용 La0.75Sr0.25FeO3의 제조 및 특성)

  • Park, Ju-Hyun;Son, Hui-Jeong;Lim, Tak-Hyoung;Lee, Seung-Bok;Yun, Ki-Seok;Yoon, Soon-Gil;Shin, Dong-Ryul;Song, Rak-Hyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.1
    • /
    • pp.7-13
    • /
    • 2007
  • We synthesized and investigated $La_{0.75}Sr_{0.25}FeO_3$ by Glycine Nitrate Process(GNP) method used as cathode materials for SOFC(solid oxide fuel cell). Optimized amount of glycine is 3.17 mol. ICP elemental composition analysis indicated that the stoichiometry of the synthesized powders have nearly nominal values. SEM images and XRD patterns reveal that the synthesized powder has uniform size distribution and high degree of crystallinity. The sample powders were isostatically pressed to form a pellet. The green body was sintered at $1200^{\circ}C$ and the relative density of the sintered specimens were measured by Archimedes mettled. We measured electrochemical performance of LSF by AC impedance spectroscopy. Resistance of LSF shows lower value than that of LSM throughout all temperature region. The anode-supported solid oxide fuel cell showed a performance of $342mW/cm^2(0.7V,\;488mA/cm^2)$ at $750^{\circ}C$. The electrochemical characteristics of the single cell were examined by at impedance method.

Preparation of Cobalt-Substituted Iron Oxide Powder from Organometallic Precursors (Ⅱ) (유기금속 전구체로부터 코발트 치환 산화철 분말 제조 (Ⅱ))

  • Kim, Jeong Su;Gang, Han Cheol;Hong, Yang Gi
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.2
    • /
    • pp.92-100
    • /
    • 1994
  • Ultrafine cobalt-substituted iron oxide particles were prepared by the thermal decomposition and oxidation of the new organometallic precursor, $Co_xFe_{1-x}(N_2H_3COO)_2(N_2H_4)_2$ (x = 0, 0.01, 0.02, 0.03, 0.05, 0.10, 1.00). The organometallic precursors were synthesized by the reaction of Co(II) and Fe(II) ion in a mole ratio of x : 1-x with hydrazinocarboxylic acid, and characterized by quantitative analysis, elemental analysis and infrared spectroscopy. The mechanistic study on the thermal decomposition of the organometallic precursors was performed by TG-DTG and DSC. The cobalt-substituted iron oxide particles were obtained by the heat treatment of the precursors at $350^{\circ}C$ and $450^{\circ}C$ for six hours in air. The prepared iron oxide was found to have two phases such as ${\gamma}-Fe_2O_3$ and a mixture of ${\gamma}-Fe_2O_3\;and\;{\alpha}-Fe_2O_3$ at $350^{\circ}C$ and $450^{\circ}C$ respectively. The particle shape was equiaxial and the particle size was less than 0.05 ${\mu}m.$ The coercivity and squareness of the cobalt substituted iron oxide particles increased with increasing cobalt content. Both coercivity and squareness showed higher values at $450^{\circ}C.$

  • PDF

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

The Relationship between Dental Amalgam Fillings and Urinary Mercury Concentration among Elementary School Children in a Metropolitan Area (대도시지역 일부 초등학생의 치과용 아말감 충전치아와 요중 수은농도의 관련성)

  • Jung, Yun-Sook;Sakong, Joon;An, Seo-Young;Lee, Young-Eun;Song, Keun-Bae;Choi, Youn-Hee
    • Journal of dental hygiene science
    • /
    • v.12 no.3
    • /
    • pp.253-258
    • /
    • 2012
  • Dental amalgam is an alloy composed of a mixture of approximately equal parts of elemental liquid mercury and an alloy powder. Amalgam has been the most popular and effective restorative material used in dentistry. Despite the long history and popularity of dental amalgam as a restorative material, there have been periodic concerns regarding the potential adverse health effects arising from exposure to mercury in amalgam. Since children are more at risk for mercury toxicity, we aimed to assess the association between dental amalgam filling and urinary mercury concentration in children. 581 of elementary school children in grades 1st4th were conveniently recruited from two schools located in Daegu city, Korea. To obtain dental caries experience states, oral examination were conducted using the full term for DFS index, number of amalgam filling surfaces and the type of filling materials. A questionnaire was used to collect information about general characteristics and the frequencies of tooth brushing, gum chewing and fish/seafood consumption. The statistical analysis was done using the SPSS 18.0 program. The mean urinary mercury concentration in children having more surfaces was highest. As a results Urinary mercury concentration of children who have 79 teeth of amalgam filling and more than 10 is higher than without amalgam filling. The number of amalgam filling surface is closely related with urinary mercury concentration.

Preparation of Nanocomposite Metal Powders in Metal-Carbon System by Mechanical Alloying Process (기계적 합금화 방법에 의한 금속-카본계에서의 나노복합금속분말의 제조)

  • Kim, Hyun-Seung;Lee, Kwang-Min
    • Korean Journal of Materials Research
    • /
    • v.8 no.4
    • /
    • pp.328-336
    • /
    • 1998
  • In metal-carbon system with no mutual solubility between matrix and alloying elements as solid or liquid phases, Cu-C-X nanocomposite metal powders were prepared by high energy ball milling for solid-lubricating bronze bearings. Elemental powder mixtures of Cu-lOwt.%C- 5wt. %Fe and Cu- lOwt. %C- 5wt. %Al were mechanically alloyed with an attritor in an argon atmosphere, and then microstructural evolution of the Cu-C-X nanocomposite metal powders was examined. It has been found that after 10 hours of MA, the approximately 10$\mu\textrm{m}$ sized Cu-C- X nanocomposite metal powders can be produced in both compositions. Morphological characteristics and microstructural evolution of the Cu-C-X powders have shown a similar MA procedure compared to those of metal-metal system. As a result of X - ray diffraction analysis, diffraction peaks of Cu and C were broaden and peak intensities were decreased as a function of MA time. Especially, the gradual disappearance of C peaks in the X- ray spectra is proved to be due to the lower atomic scattering factor of C. The calculated Cu crystallite sizes in Cu- C- X nanocomposite metal powders by Williamson- Hall equation were about lOnm size, on the other hand, the observed ones by TEM were in the range of 10 to 30nm.

  • PDF