• 제목/요약/키워드: Elemental Errors

검색결과 11건 처리시간 0.022초

Elemental Image Generation Method with the Correction of Mismatch Error by Sub-pixel Sampling between Lens and Pixel in Integral Imaging

  • Kim, Jonghyun;Jung, Jae-Hyun;Hong, Jisoo;Yeom, Jiwoon;Lee, Byoungho
    • Journal of the Optical Society of Korea
    • /
    • 제16권1호
    • /
    • pp.29-35
    • /
    • 2012
  • We propose a subpixel scale elemental image generation method to correct the errors created by finite display pixel size in integral imaging. In this paper, two errors are mainly discussed: pickup-and-display mismatch error and mismatch error between pixel pitch and lens pitch. The proposed method considers the relative positions between lenses and pixels in subpixel scale. Our proposed pickup method calculates the position parameters, generates an elemental image with pixels completely inside the lens, and generates an elemental image with border pixels using a weighted sum method. Appropriate experiments are presented to verify the validity of the proposed method.

MLSPIV를 이용한 유속산정시 오차요인 규명 및 실내실험을 통한 유속산정오차 분석 (Identification of Factors Affecting Errors of Velocity Calculation on Application of MLSPIV and Analysys of its Errors through Labortory Experiment)

  • 김영성;이현석
    • 한국수자원학회논문집
    • /
    • 제43권2호
    • /
    • pp.153-165
    • /
    • 2010
  • Large-Scale Particle Image Velocimetry (LSPIV)는 Particle Image Velocimetry (PIV)를 실험실내의 비교적 규모가 큰 흐름이나 하천에서의 표면유속장의 측정 등 넓은 영역에 적용할 수 있도록 확장시킨 것이다. LSPIV는 PIV의 구성요소를 포함하여 추적자 투하, 조명, 촬영, 이미지 변환, 이미지 처리 및 후처리의 여섯 단계로 구성된다. 본 연구에서는 LSPIV의 모바일 버전인 MLSPIV를 이용하여 하천에서의 유속측정시 각 단계별로 발생가능한 오차성분을 정의하였고, 기존의 연구 결과를 바탕으로 오차의 영향이 정량적으로 밝혀진 것을 정리하였다. 각 단계별로 오차 발생요인을 조사한 결과 27개의 성분오차성분을 파악하였다. 이중에서 5개의 오차요소는 기존에 연구가 진행되었고, 7개의 오차요소는 본 논문에서 적용시의 MLSPIV에는 그 효과가 미치지 않는 것으로 파악하였다. 나머지 15개의 오차성분 중 4가지 오차성분- 샘플링시간, 이미지 해상도, 추적자의 성질, 바람-에 대해서 유속산정시 미치는 영향을 파악하기 위하여 개수로 실험장치를 이용한 실내시험을 실시하였다. 이미지 프로세싱에 이용한 이미지수로부터 나타나는 유속계산 오차를 조사한 결과 이미지의 개수가 50매 이상인 경우는 이로 인한 오차가 1 % 이하로 감소함을 파악하였다. 촬영된 이미지의 해상도가 유속계산시 미치는 영향을 조사하기 위해 세 가지 이미지 해상도로 변화시키면서 유속측정 오차를 분석한 결과 저해상도의 이미지를 이용한 경우 고해상도 이미지를 이용한 경우와 비교하여 3 % 가량의 차이를 나타내었다. 추적자의 성질과 바람의 영향에 대해서는 흐름의 평균유속이 큰 경우에는 바람이 추적자에 마치는 영향이 현격히 줄어듬을 보이고 있다. 즉, 유속이 증가함에 따라 바람의 영향은 감소하나, 바람의 영향을 최소화시키기 위해서는 가급적 비중이 큰 물질(0.5

컴퓨터 집적 영상에서의 정교한 요소 영상 추출 및 전처리 방법 (Accurate lattice extraction of elemental image array and pre-processing methods in computational integral imaging)

  • 손정민;유훈
    • 한국정보통신학회논문지
    • /
    • 제15권5호
    • /
    • pp.1164-1170
    • /
    • 2011
  • 본 논문에서는 컴퓨터 집적 영상에서의 정교한 요소 영상 추출 및 전처리 기술에 대해 제안한다. 전처리 기술은 영상 복원 과정 전에 영상의 왜곡 및 잡음을 제거하는 기술이다. 픽업 과정에서 발생된 왜곡 및 잡음은 주로 회전 왜곡으로, 복원된 영상의 화질을 저하시킨다. 이 문제점을 극복하기 위해서 요소 영상 추출 및 전처리 방법을 제안하고, 이를 통하여 왜곡 및 잡음이 영상 복원 과정에 미치는 영향에 대해서 설명하였다. 광학 및 컴퓨터 실험을 통하여 교정 전, 후의 복원 영상의 특성을 비교하였다.

단일 원소 금속의 영역 선택적 원자층 증착법 연구 동향 (Recent Studies on Area Selective Atomic Layer Deposition of Elemental Metals)

  • 조민규;고재희;최병준
    • 한국분말재료학회지
    • /
    • 제30권2호
    • /
    • pp.156-168
    • /
    • 2023
  • The semiconductor industry faces physical limitations due to its top-down manufacturing processes. High cost of EUV equipment, time loss during tens or hundreds of photolithography steps, overlay, etch process errors, and contamination issues owing to photolithography still exist and may become more serious with the miniaturization of semiconductor devices. Therefore, a bottom-up approach is required to overcome these issues. The key technology that enables bottom-up semiconductor manufacturing is area-selective atomic layer deposition (ASALD). Here, various ASALD processes for elemental metals, such as Co, Cu, Ir, Ni, Pt, and Ru, are reviewed. Surface treatments using chemical species, such as self-assembled monolayers and small-molecule inhibitors, to control the hydrophilicity of the surface have been introduced. Finally, we discuss the future applications of metal ASALD processes.

PIV속도계측에 수반하는 UNCERTAINTY해석 (Analysis on the Uncertainty Accompanied by PlV Velocity Measurements)

  • 이영호;최민선
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제15권1호
    • /
    • pp.71-74
    • /
    • 1991
  • Uncertainty analyses accompanied by the measurement of the velocity vectors in 3-D cavity flows are carried out. Twenty-one elemental errors are esimated or calculated according to the ANIS/ASME uncertainty analysis manual. Error components associater with the PIV(Particle Imaging Velocimetry) are reasonably small and the errors caused by the flow characteristics are fairly large, which confirm the reliability of the PIV measurement and also give good information to the planning phase of the experiment by discriminating the most critical parameter. The present study reveals that vector length expressed by pixels is the most influential. Calculated relative uncertainty for the all experimental conditions is ranging about 5-10% in terms of the representative velocity 0.5U. U is here the belt velocity on the cavity apparatus. Approximating equations to show the relative rss uncertainties are given and graphic representations are followed for the easier understanding of the uncertainty, existing in the velocity profiles of the cavity flow.

  • PDF

구리와 코디에라이트와의 접촉점에서 구리에 대한 ESCA 스펙트럼의 에너지 교정 (Energy Calibration of ESCA Spectrum for the Copper in the Interface of Copper and Cordierite)

  • Han, Byoung-Sung
    • 대한전자공학회논문지
    • /
    • 제25권1호
    • /
    • pp.27-32
    • /
    • 1988
  • Electron Spectroscopy for Chemical Analysis(ESCA) allowes the determination of the elemental composition and the bonding state of the surface atomes in the interface between two materials. In the binding energies of ESCA spectrum, there are zero error, voltage scaling error and random error. Accurate analysis of the intensity energy response functions and accurate calibration of the energy scale are essential to use X-ray photoelectron spectron meter. At the results of the calibration of the ESCA spectra in the copper and cordierite (Mg2Al4Si5kO18) interfaces, the errors relative to the copper are -3.03 eV for the zero error -z,-197 ppm for the voltage scaling error -V and 6.9 meV for the random error -R. The method of the calibration is able to apply for the binding energy calibration of the another ESCA spectra.

  • PDF

Qualitative Analysis of the Major Constituents in Traditional Oriental Prescription Bang-poong-tong-sung-san by Liquid Chromatography/Ultraviolet Detector/Ion-Trap Time-of-Flight Mass Spectrometry

  • Eom, Han Young;Kim, Hyung-Seung;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • 제5권1호
    • /
    • pp.24-29
    • /
    • 2014
  • An advanced and reliable high performance liquid chromatography (HPLC)/ultraviolet detector (UV)/ion-trap time-of-flight (IT-TOF) mass spectrometry was developed for the simultaneous quantification of 19 marker compounds in Bang-poong-tong-sung-san (BPTS), a traditional oriental prescription. Various parameters affecting HPLC separation and IT-TOF detection were investigated, and optimized conditions were identified. The separation was achieved on a Capcell PAK C18 column ($1.5mm{\times}250mm$, $5{\mu}m$ particle size) using a gradient elution of acetonitrile and water containing 0.1% formic acid at a flow rate of 0.1 mL/min. The column temperature was maintained at $40^{\circ}C$ and the injection volume was $2{\mu}L$. IT-TOF system was equipped with an electrospray ion source (ESI) operating in positive or negative ion mode. The optimized electrospray ionization parameters were as follows: ion spray voltage, +4.5 kV (positive ion mode), or -3.5 kV (negative ion mode); drying gas ($N_2$), 1.5 L/min; heat block temperature, $200^{\circ}C$. Automatic $MS^n$ (n = 1~3) analyses were carried out to obtain structural information of analytes. Elemental compositions and their mass errors were calculated based on their accurate masses obtained from a formula predictor software. The marker compounds in BPTS were identified by comparisons between $MS^n$ spectra from standards and those from extracts. Moreover, the libraries of $MS^2$ and $MS^3$ spectra and accurate masses of parent and fragment ions for marker compounds were constructed. The developed method was successfully applied to the BPTS extracts and identified 17 out of 19 marker compounds in the BPTS extracts.

가스크로마토그래피에 依한 微量元素分析 (A New Gas-Chromatograghic Method of Organic Elemental Analysis)

  • 김유선;손연수;최규원
    • 대한화학회지
    • /
    • 제8권4호
    • /
    • pp.188-191
    • /
    • 1964
  • 微量元素分析用 燃燒爐 內에서 內部酸化劑(酸化銀과 二酸化 망간의 混合物)와 함께 有機試料를 헤륨 氣流下에서 燃燒시키고 發生한 물은 칼슘카바이드管에 通하여 아세틸렌으로 變換시킨다. 二酸化炭素와 아세틸렌을 molecular sieve 5A 管에 室溫에서 吸着시킨 후 $340^{\circ}C$까지 溫度${\cdot}$프로그탬法으로 脫着시켜 실리카켈管을 通하여 分別流出시키고 熱傳導式 檢知器로 $CO_2$$C_2H_2$를 定量하는 方法을 發展시켰다. 벤조酸을 標準物質로 하여 作成한 檢量線을 使用하여 各種 有機試料中의 炭素 및 水素含量을 分析한 結果 平均誤差가 炭素의 경우 ${\pm}0.5%$, 水素인 경우${\pm}0.33%$ 이었다.

  • PDF

Accurate mass 및 isotope ratio 측정을 위한 GC-TOF 질량분석기에서의 화학적 이온화방법 (Development of chemical ionization method in a GC-TOF mass spectrometer for accurate mass and isotope ratio measurement)

  • 정주희;나윤철;황금숙;신정화;안윤경
    • 분석과학
    • /
    • 제24권1호
    • /
    • pp.15-23
    • /
    • 2011
  • 본 연구에서는 미지 대사물질 동정을 위해 GC-TOF/MS의 양이온 화학적 이온화 방법(positive chemical ionization, $CI^+$)을 이용, 정확한 질량 값(accurate mass)과 동위원소 비(isotope ratio) 측정을 위한최적 조건을 확립하였다. 분자이온 $[M+H]^+$ 세기를 증가시킬 수 있는 high mass tune 방법이 사용되었으며, 화합물들의 분리 및 감도에 따른 검출조건이 고려되어 졌다. 24종의 trimethylsilyl (TMS)기로 유도체화 된 표준 대사물질들을 분석한 결과 $[M+H]^+$의 경우 이론 값 과의 절대평균오차는 6.8 ppm이였으며, 동위원소 비(M+1/M, M+2/M)의 경우는 각각 1.5%와 1.7%였다. 얻어진 질량 값과 동위원소 비를 원소조성 알고리즘에 적용한 결과 21개의 화합물의 구조식이 2순위 내에서 일치하였다.

광주 지역에서 aethalometer 측정 블랙 카본 입자의 질량흡수단면 평가 (Aethalometer-based Estimate of Mass Absorption Cross Section of Black Carbon Particles at an Urban Site of Gwangju)

  • 박승식;유근혜;이상일;배민석
    • 한국대기환경학회지
    • /
    • 제34권5호
    • /
    • pp.727-734
    • /
    • 2018
  • In this study, real-time absorption coefficients of carbonaceous species in $PM_{2.5}$ was observed using a dual-spot 7-wavelength Aethalometer between November 1, 2016 and December 31, 2017 at an urban site of Gwangju. In addition, 24-hr integrated $PM_{2.5}$ samples were simultaneously collected at the same site and analyzed for organic carbon and elemental carbon (OC and EC) using the thermal-optical transmittance protocol. A main objective of this study was to estimate mass absorption cross section (MAC) values of black carbon (BC) particles at the study site using the linear regression between aethalometer-based absorption coefficient and filter-based EC concentration. BC particles observed at 880 nm is mainly emitted from combustion of fossil fuels, and their concentration is typically reported as equivalent BC concentration (eBC). eBC concentration calculated using MAC value of $7.77m^2/g$ at wavelength of 880 nm, which was proposed by a manufacturer, ranged from 0.3 to $7.4{\mu}g/m^3$ with an average value of $1.9{\pm}1.2{\mu}g/m^3$, accounting for 7.3% (1.5~20.9%) of $PM_{2.5}$. The relationship between aerosol absorption coefficients at 880 nm and EC concentrations provided BC MAC value of $15.2m^2/g$, ranging from 11.4 to $16.2m^2/g$. The eBC concentrations calculated using the estimated MAC of $15.2m^2/g$ were significantly lower than those reported originally from aethalometer, and ranged from 0.2 to $3.8{\mu}g/m^3$, with an average of $1.0{\pm}0.6{\mu}g/m^3$, accounting for 3.7% of $PM_{2.5}$ (0.8~10.7%). Result from this study suggests that if the MAC value recommended by the manufacturer is applied to calculate the equivalent BC concentration and radiative forcing due to BC absorption, they would result in significant errors, implying investigation of an unique MAC value of BC particles at a study site.