• Title/Summary/Keyword: Electrostatic current

Search Result 205, Processing Time 0.023 seconds

Research on the Relation between Transformer Oil Flow Electrification and Electrostatic Current

  • Fu, Qiang;Wang, Rui;Zou, Pinguo;Li, Zhao;Yang, Yang;Xie, Xuejun
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.610-615
    • /
    • 2015
  • In order to study and obtain the mathematical relation between the electrification degree of transformer oil flow and the electrostatic current, a small amount of data about the electrification degree of oil flow and the corresponding electrostatic current is studied by linear regression method and grey model method. The results show that the linear correlation between the electrification degree and the electrostatic current was not good, and the relation between the electrification degree of oil flow and electrostatic current (i) could be expressed as ${\rho}(0)=0.2049\;i^{(0)}+169.4419$ according to grey model GM (0, 2) when the electrification degree of oil flow is represented by the charge number generated from transformer oil per unit volume, namely the charge density (${\rho}$).

A Study on the Improvement Plan of Electrostatic Safety Management Level through Injury Analysis (재해분석을 통한 정전기 안전관리 수준 향상 방안 연구)

  • Choi, Sang-won;Jeong, Seong-Choon;Park, Jae Suk;Yang, Jeong Yeol;Byeon, Junghwan
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.37-45
    • /
    • 2019
  • The characteristic of fire and explosion related to electrostatic discharge is that it is difficult to reproduce the electrostatic charge and discharge phenomenon in addition to the large human and material damage. Therefore, in order to prevent accidents and disasters related to electrostatic in fire and explosion hazard areas, it is important to manage the level of electrostatic in a safe manner from the perspective of system between industrial facilities and human bodies. Rule 325 of the Occupational Safety and Health Regulations, "Prevention of Fire / Explosion due to Electrostatic", requires the use of grounding, conductive materials, humidification and electrification in order to prevent the risk of disaster caused by static explosion and electrostatic in the production process. In order to comply with these measures, related technologies, standards and systems are needed from the viewpoint of preventive measures related to electrostatic in fire and explosion hazard areas, but in Korea, it is still insufficient. Therefore, technical, institutional and managerial measures are needed as a precautionary measure to improve the level of ESD safety in fire and explosion hazard areas and prevent electrostatic related injury. In Korea, we analyzed the current status and characteristics of electrostatic related disaster by using the statistics of industrial accident and fire statistics of the Ministry of Employment and Labor. We also analyzed the current status and characteristics of electrostatic related disasters in Japan using JNIOSH accidents and disasters investigation cases and JNIOSH fire accident data of Japan Fire Bureau. The purpose of this study is to compare and analyze the current status of electrostatic related accidents and disasters in Korea and Japan in order to improve the safety management of electrostatic in fire and explosion hazard areas. In order to prevent accidents and disasters in the industrial field, The technical, institutional, and managerial measures to manage the level of electrostatic in a safe state were derived from the system point of view.

Experimental Study on the Discharge Electrode of A Two-Stage Electrostatic Air Cleaner (2단 평행판 전기집진기의 방전부 특성 실험)

  • Kim, I.S.;Lee, J.O.;Kim, Y.J.;Choi, H.O.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.1
    • /
    • pp.27-34
    • /
    • 1993
  • The two-stage electrostatic air cleaner is a particle control device that uses electrical forces to move particles in the flowing gas stream onto collector plates. Despite a general understanding of electrostatic air cleaner operation and their successful use in industry, many questions regarding flow, electric fields and particle collection have remained unanswered. In this paper, an experimental investigation for designing the discharge electrode, including ionizer wire diameter, plate length and wire-to-plate spacing, is carried out. The electrical conditions, namely the electric field intensity, the space current and the particle charge intensity, in wire-plate electrostatic air cleaner are reported and examined.

  • PDF

Charging Characteristics of Electrostatic Sprayer Applied Square Pulse (구형파 펄스를 인가한 정전분무 장치의 대전량 특성)

  • 박승록;문재덕
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.12
    • /
    • pp.573-578
    • /
    • 2003
  • In this study, new type of induction charging system for electrostatic spraying was manufactured and proposed to improve the electrical safety and charging efficiency. And parameters of proposed system to generate the maximum deposition current with electrical safety were selected and investigated. The selected parameters were frequency of square pulse and thickness of insulation material, outer diameter of device and thickness and positions of electrode. Charging quantity of water drop was measured by deposition current detected from sensing plate indirectly. The maximum deposition current for each parameter were 3.5[uA] at the frequency of 15[kHz] and thickness of 0.25[mm] insulating layer. And maximum deposition currents were 2.8[uA] and 3.0[uA] at 25[mm] outer diameter of charging device and 0.25[mm] thickness of electrode each. Effects of electrode position from spraying nozzle on deposition current was a little.

Degradation Behavior of 850 nm AlGaAs/GaAs Oxide VCSELs Suffered from Electrostatic Discharge

  • Kim, Tae-Yong;Kim, Tae-Ki;Kim, Sang-In;Kim, Sang-Bae
    • ETRI Journal
    • /
    • v.30 no.6
    • /
    • pp.833-843
    • /
    • 2008
  • The effect of forward and reverse electrostatic discharge (ESD) on the electro-optical characteristics of oxide vertical-cavity surface-emitting lasers is investigated using a human body model for the purpose of understanding degradation behavior. Forward ESD-induced degradation is complicated, showing three degradation phases depending on ESD voltage, while reverse ESD-induced degradation is relatively simple, exhibiting two phases of degradation divided by a sudden distinctive change in electro-optical characteristics. We demonstrate that the increase in the threshold current is mainly due to the increase in leakage current, nonradiative recombination current, and optical loss. The decrease in the slope efficiency is mainly due to the increase in optical loss.

  • PDF

A Study on Electrical Degradation Properties of Epoxy Resin due to Moisture Absorption (흡습에 의한 에폭시 수지의 전기적 열화 특성에 관한 연구)

  • Lee, Sung Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.9
    • /
    • pp.656-661
    • /
    • 2013
  • In this study, the moisture content, charge discharge current, electrostatic capacity and dielectric loss tangent are measured for the specimen of bisphenol type epoxy resin which is mixed with squared amorphous silica filler and dipped in hot water of $50^{\circ}C$ for 169 days. The results of this study are listed below. The longer of deposition day, the charge and discharge current was increased. It is considered that the reason is because there was water attack through the squared silica surface. The longer of deposition day, the absorption rate of all specimens was increased. It found that the absorption rate reached saturated state after 100 days. The higher frequency and the longer of deposition day, the $tan{\delta}$ was decreased. Also, It found that the $tan{\delta}$ and electrostatic capacity of the specimen which is mixed with squared filler are greater.

A Study on Collection Efficiency of Pilot Electrostatic Precipitator (연소장치를 이용한 소형 전기집진장치의 집진 효율에 관한 연구)

  • 한재균;최금찬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.2
    • /
    • pp.125-131
    • /
    • 1993
  • Electrostatic Precipitator has been widely used to get high efficiency which is required for collection of fine particles. In order to provide collection efficiency and size distribution data for a pilot electrostatic precipitator, a pilot study has been conducted on fly ash from pulverized coal burning apparatus. The aims of this study are to investigate characteristics of electric charge, to measure collection efficiency varied with the applied voltage, to get an optimum current and current density. Optimum current density was obtained to 0.7mA/$cm^2$ at the average electric field strength 2.33kV/cm in this experiment. Maximum particle collection efficiency was indicated 99.21% at the applied voltage 7kV. Finally, particle size distribution is also compared with photographic results. Both coarse and fine particles at the range of 0.5$\sim$2$\mu$m and 3$\sim$10 SEM $\mu$m were clearly removed by increasing applied voltage.

  • PDF

A Study on the Collection Characteristics of a Wide Plate-Spacing Electrostatic Precipitator -II. Effect of Wave Form of Pulse Energization - (광폭 전기집진기의 집진특성에 판한 연구 - II. 펄스 하전 파형의 영향 -)

  • 김용진;하병길;정상현;홍원석;하대홍;유주식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1059-1064
    • /
    • 2001
  • This study Investigates the effect of the wave form of pulse energization on the collection characteristics of a wide plate spacing electrostatic precipitator. For the semi-pulse energization, the peak current and voltage of the energization increases with increase of the pulse period, and the corona current increases, as pulse ratio decreases. For the micro-pulse energization, the corona current increases with increase of the pulse voltage. The collection efficiency of semi-pulse and micro-pulse energization is larger than that of DC charge.

  • PDF

A Study on the Collection Characteristics of a Moving Electrode Electrostatic Precipitator - I. Effect of Collection Plate Velocity - (이동 전극형 전기집진기의 집진특성에 관한 연구 - I. 집진판 이동 속도의 영향-)

  • Kim Yong-Jin;Ha Byung-Kil;Jeong Sang-Hyun;Moon Sang-Cheol;Yoo Joo-Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.901-907
    • /
    • 2004
  • This study investigate the effect of collection plate velocity on the electrical and collection characteristics of a moving electrode electrostatic precipitator (MEEP). Though a high resistivity fly ash is attached at the collecting electrode, the MEEP has very stable characteristics of voltage and corona current. Collection efficiency, corona current, and overall collection efficiency are increased, as the magnitude of the collection plate velocity increases.

Characteristics of long-term operated Electrostatic airclean filter for air-conditioner (장시간사용(長時間使用)한 공조용(空調用) 전기집진(電氣集塵)필터의 특성(特性))

  • Hong, Young-Ki;Kang, Kwang-Ok;Lee, Sung-Hwa;Son, Sang-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.453-455
    • /
    • 1995
  • In electrostatic airclean filter, the collection efficiency defends on particle charge in the ionizer section. The effect of electrostatic airclean filter condition (deposition of dust, variation of corona discharge current) on corona discharge characteristics was well studied. However, it seems not to be studied on corona discharge characteristics of electrostatic airclean filter respect to contaminated electrode which is caused by practical use. In this paper, Long-term(60days) effects are studied experimentally by two methods. The one is ozone concentration, the other is collection efficiency. Generation of ozone level was increased but collection efficiency was slightly reduced in long-term used electrostatic airclean filter.

  • PDF