• Title/Summary/Keyword: Electronics Housing

Search Result 65, Processing Time 0.037 seconds

Hybrid Uninterruptible Power Supply for Apartment Housing (공동주택용 하이브리드 무정전전원장치)

  • Lim, Seung-Beom;Lee, Won-Il;Kim, Myeong-Soo;Hong, Soon-Chan
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.530-531
    • /
    • 2015
  • 본 논문에서는 공동주택용 하이브리드 무정전전원장치(UPS: Uninterruptible Power Supply)를 제안한다. 제안한 하이브리드 UPS는 기존의 UPS 시스템에 DC/DC 컨버터를 추가하여 태양광 패널과 연결 가능하여 기존의 태양광 PCS(Power Conditioning Supply)의 기능을 할 수 있다. 또한 정류기를 양방향으로 동작시켜 피크 부하시나 전력 부족시 전력을 전원단으로 회생시킬 수 있어 기존의 ESS(Energy Storage System) PCS 기능도 할 수 있다.

  • PDF

Microstrip Directional Coupler Design with High Performance Using Optimization based on Evolution Strategy

  • Joung, Myoung-Sub;Park, Jun-Seok;Kim, Hyeong-Seok;Lim, Jae-Bong;Cho, Hong-Goo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.6
    • /
    • pp.276-281
    • /
    • 2004
  • In this paper, the optimal design of a novel microstrip directional coupler with a grooved housing for high directivity characteristic is presented. It will be shown that the high directivity of the microstrip coupler can be achieved simply by attaching an optimized housing structure. over the microstrip, which is much easier to fabricate than other conventional types. The dimensions of the proposed structure are maximized by using (1+1) evolution strategy (ES) combined with the deterministic algorithm. To improve the effectiveness of the results, efficient optimization procedures suitable for the model are proposed. From these results, it is determined that the proposed structure indicates an improved directivity. The optimized results are verified by full wave analysis at the center frequency of 850MHz.

Reduction Effect of Airborne Pollutants in Pig Building by Air Cleaner Operated with Plasma Ion (플라즈마 이온 방식의 공기정화기를 이용한 돈사내 공기오염물질 저감 효과)

  • Kim, Yoon-Shin;Kim, Ki-Youn;Cho, Man-Su;Ko, Moon-Suk;Ko, Han-Jong;Jung, Jin-Won;Oh, Mi-Seok;Youn, Baek;Kim, Jung-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.4
    • /
    • pp.306-312
    • /
    • 2010
  • This field study was performed to evaluate the efficiency of a plasma ion-operated air cleaner in temporal reduction of airborne pollutants emitted from a pig housing facility. In the case of gaseous pollutants, the plasma ion air cleaner was not effective in reducing levels of ammonia, hydrogen sulfide, nitrogen dioxide, or sulfur dioxide (p>0.05). In the case of particulate pollutants, however, the air cleaner was effective in reducing levels of particulate matter ($PM_{2.5}$ and $PM_1$) by 79(${\pm}6.1$) and 78(${\pm}3.0$)%, respectively. Unlike the case of these fine particle fractions, the reduction of total suspended particles (TSP) and $PM_{10}$ following treatment was almost negligible. In the case of biological pollutants, the mean reduction efficiencies for airborne bacteria and fungi were relatively low at 22(${\pm}6.6$) and 25(${\pm}8.7$)%, respectively. Taken together, these results indicate that in terms of air pollutants released from this pig housing facility, the plasma ion air cleaner was primarily effective in reducing levels of $PM_{2.5}$ and $PM_1$.

Research on Metadata Schema for Data Exchange between Smart Housing Fire Service and Smart City Integration Platform (스마트하우징 화재 서비스의 스마트시티 플랫폼 연계 데이터 교환용 메타데이터 스키마 연구)

  • Dae-Kug Lee;Dae-Gyu Lee;Hyun-Kook Kahng;Choong-Ho Cho
    • Journal of Internet Computing and Services
    • /
    • v.25 no.2
    • /
    • pp.113-122
    • /
    • 2024
  • Recently, cutting-edge ICT technologies such as artificial intelligence, blockchain, edge computing, and the Internet of Things have been applied in various fields to create new services and a new digital era. Along with these technological developments, various policies are being implemented in Korea to transform the country from a "Smart City" to a "Platform City". We can create new services and values by linking with the Smart City Integrated Platform and Smart Housing Platform. This paper defines a linkage scenario between a Smart Housing Platform and the Smart 119 Emergency Dispatch Support Service, one of the Smart City Safety Nets. We propose a data transmission protocol and a metadata schema for data exchange between the Smart Housing Platform and the Smart City Integrated Platform to provide the Smart 119 Emergency Dispatch Support Service.

The Effect of EMC by Metal Cover and Noise Reduction Method (Metal Cover에 의한 EMC 분석 및 Noise 저감 방법)

  • Yun, Sangwon;Park, Chuleui;Lee, Chanho;Kim, Sehyun;Yang, Manyoung;Kim, Dongsik;Yoo, Jiyoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.3
    • /
    • pp.143-147
    • /
    • 2014
  • The ECU which is operating inductive actuator like motor or solenoid should be designed with considering the heat removal performance and the EMC performance. In most cases, these two performances are trade-off. Especially, the metal cover with plastic housing for improving heat removal performance can affect EMC performance by coupling the noise source to harness cable and connector. Therefore, after analyzing the EMC effectiveness of the metal cover, countermeasures for EMC noise reduction should be established. In this paper, by simulating and testing of AHB Gen3 ECU, the influence of the metal cover to EMC performance is analyzed. And based on this result, we propose solutions for EMC noise reduction.

Implementation of cost-effective wireless photovoltaic monitoring module at panel level

  • Jeong, Jin-Doo;Han, Jinsoo;Lee, Il-Woo;Chong, Jong-Wha
    • ETRI Journal
    • /
    • v.40 no.5
    • /
    • pp.664-676
    • /
    • 2018
  • Given the rapidly increasing market penetration of photovoltaic (PV) systems in many fields, including construction and housing, the effective maintenance of PV systems through remote monitoring at the panel level has attracted attention to quickly detect faults that cause reductions in yearly PV energy production, and which can reduce the whole-life cost. A key point of PV monitoring at the panel level is cost-effectiveness, as the installation of the massive PV panels that comprise PV systems is showing rapid growth in the market. This paper proposes an implementation method that involves the use of a panel-level wireless PV monitoring module (WPMM), and which assesses the cost-effectiveness of this approach. To maximize the cost-effectiveness, the designed WPMM uses a voltage-divider scheme for voltage metering and a shunt-resistor scheme for current metering. In addition, the proposed method offsets the effect of element errors by extracting calibration parameters. Furthermore, a design method is presented for portable and user-friendly PV monitoring, and demonstration results using a commercial 30-kW PV system are described.

A Study on the New Configuration of Dielectric Bandpass Filter Using Comb-Line Design Theory (Comb-Line 설계 이론을 이용한 세라믹 유전체 대역통과 필터의 새로운 구현에 관한 연구)

  • 오창헌;임상규안철
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.621-624
    • /
    • 1998
  • This paper presents a new configuration of dielectric bandpass filter using the comb-line filter design theory. This filter is composed of a homogeneous dielectric monoblock $(\varepsilonr=35.5)$ with two metal post and a dielectric sheet $(\varepsilonr=9.8).$ In this structure, the RF leakage is suppressed without other shield housing. For the fabricated filter, insertion loss value in the passband region was 0.9dB(Max.) and return loss value was 19dB(Min). Also, this filter has a attenuation pole in the stopband.

  • PDF

A study on 12W SSPA for earth station transmonder at ku-band (Ku-band 지구국 중계기를 위한 12W SSPA에 관한 연구)

  • 조창환;여인혁;홍의석
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.6
    • /
    • pp.72-80
    • /
    • 1996
  • This paper presetns the development of a SSPA operating at KU-band(14~14.5 GHz) in order of replace TWTA used in the terrestria transponder of a satellite communication. The driving stage of SSPA uses internally matched 2W, 4W, 8W FET and the power stage is coupled with two internally matched 8W FET by branch-line cominer. The SSPA is fabricated with oth the RF circuit and the bias circuitry operating temperature compensation, regulation and sequence on aluminum housing. The SSPA testing resutls implemented in this way show 24.8$\pm$1dB small-signal gain, 41dBm P1dB power, a typical two tone C/IM3, -33dBc with single carrier backed off 6dB from p1dB, and gain stability over temeprature (-30~50)$\pm$1dB.

  • PDF

Fatigue Characteristic of HIPS(HR-1360) Materials (HIPS(HR-1360) 재료의 피로 특성 평가)

  • Park, Jae-Sil;Seok, Chang-Sung;Lee, Jong-Gyu;Lee, Jae-Hyuk
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.129-134
    • /
    • 2000
  • Recently, HIPS(High Impact Polystyrene) materials are spot-lighted as office equipment, home electronics, electronics appliances housing, packing containers, etc. But its using are occur to problem caused by fatigue fracture. However, its strength is larged affected by environmental conditions. So, in this paper it tried to analyze the effect of temperature by tensile test and fatigue test. It was observed that yield strength and ultimate strength, fatigue life of same stress decreased relatively with increase temperature. Further, this paper predict S-N curve using the result of tensile test and micro vickers hardness test. For this purpose, the management in the engineering department is able to design the fatigue life of HIPS(HR-1360) materials.

  • PDF