• Title/Summary/Keyword: Electronic power meter

Search Result 60, Processing Time 0.033 seconds

Electrical Characteristics of Optical Current Transducer on Gas Insulated Switchgear (GIS용 광CT의 전기적 특성)

  • Lee, Su-Woong;Lee, Sung-Gap;Noh, Hyeon-Ji;Ahn, Byeong-Rib;Won, Woo-Sik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.319-320
    • /
    • 2007
  • We researched basic study about electrical characteristics of Zinc Selenide (Faraday Cell), which is known for various temperature of good-performance, that applied measuring current or protecting instrument by Optical Current Transducer, on Gas Insulated Switchgear. Measuring System consists of VCSEL produced 850nm IR Laser, Pin Photo Diode made of GaAs surveyed as Optical Power Meter, and Optical Fibers specified Multi-mode. We observed optical output changes during measurement of currents increasing by 100[A] in range from 0[A] to 1,000[A] and set temperature condition increasing by $5[^{\circ}C]$ in a range from $30[^{\circ}C]\;to\;60[^{\circ}C]$.

  • PDF

A Diagnosis Method of Communication Networks for AMI Smart Meters (AMI 시스템 구축용 스마트 미터의 통신 상태 진단방법)

  • Jung, Joonhong;Choi, Gilyong
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.55-56
    • /
    • 2015
  • A smart meter is a kind of electronic meters that measures and records consumption of electric energy in intervals of an hour or less and transmits that information to the remote places. AMI provides two-way communication path between utilities and consumers and should be able to support smart grid's new functionalities such as demand-response actions and real time pricing. The main objective of this paper is to provide a new diagnosis method and system for testing of smart meters in AMI neighborhood area network.

  • PDF

Design for a Fuse of High Durability Protection Elements for Improving the Safety of DC Current Measurement Device (직류전류측정기의 안전성 향상을 위한 고내구성 보호소자의 가용체 설계)

  • Lee, Ye Ji;Youn, Jae Seo;Cho, Sung Chul;Noh, Sung Yeo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.3
    • /
    • pp.201-207
    • /
    • 2020
  • With the expansion in the use of DC power systems and increased need for system maintenance, the development of measurement devices for maintenance requires high stability. Of the different kinds of DC current measurement devices, the single-shot measurement device causes the input signal of the current measuring unit to initially generate a high inrush current. The high inrush current flows into the signal processor of the meter, shortening the life of the internal fuses and causing failure. Therefore, in this study, the I2t value for increasing the durability of the fuse is designed using the available wire diameter. Operating characteristics for 210~400% over-current of the rated current, which is relatively low over-current, are realized by the plating of low melting tin metal. As a result, a method of designing a fuse element for a DC power supply, which improves the safety of the DC current measurement device by blocking the failure caused by the inrush current, is presented.

Development of DC Controller for Battery Control for Elevator Car

  • Lee, Sang-Hyun;Kim, Sangbum
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.2
    • /
    • pp.103-111
    • /
    • 2021
  • Among transport vehicles, Special Vehicles (SVs) are seriously exposed to energy and environmental problems. In particular, elevator cars used when moving objects in high-rise buildings increase the engine's rotational speed (radian per second: RPM). At this time, when the vehicle accelerates rapidly while idling, energy consumption increases explosively along with the engine speed, and a lot of soot is generated. The purpose of this paper is to develop a bi-directional DC-DC converter for control of vehicle power and secondary battery used in an elevated ladder vehicle (EC) used in the moving industry. As a result of this paper, the performance test of the converter was conducted. The charging/discharging state of the converter was simulated using DC power supply and DC electronic load, and a performance experiment was conducted to measure the input/output power of the converter through a power meter. Through this experimental result, it was confirmed that the efficiency was more than 92% in Buck mode and Boost mode at maximum 1.2kW output.

Magnetic Force Properties of Superconducting Bulk (초전도 벌크의 자기적 특성을 위한 간편한 시스템)

  • Sang Heon Lee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.1
    • /
    • pp.70-73
    • /
    • 2023
  • To improve superconductor properties, the size of the crystal grains of the superconductor should be adjusted, the amount of electricity flowing through the superconductor should be increased, and the superconductor should be designed to withstand external magnetic fields. It is necessary to control the microstructure so that many flux pinning centers are developed inside the superconductor so that defects are generated physically or chemically, and the micro secondary phase for trapped magnetic flux must be dispersed inside the superconductor. In order to measure the superconducting magnetic force of the superconducting bulk in a simplified manner, the superconducting magnetic force was analyzed using an Nd-Fe-B permanent magnet of 3.80 kG. In particular, by delaying the growth of partially melted Y2BaCuO5 particles, we devised a plan to refine Y2BaCuO5 particles to effectively improve superconducting magnetic force, and analyzed superconducting magnetic force in a single crystal YBa2Cu3O7-y superconducting bulk using a gauss meter. The melted superconducting bulk traps 80% or more of the applied magnetic field, and can be used as a bulk magnet of high magnetic field magnetization applicable to electric power equipment.

Design and Implementation of Portable Electrostatic Meter Applicable to Industrial Site (산업 현장에 적용할 수 있는 휴대형 정전기 측정기 설계 및 구현)

  • Jang, Mun-Seok;Lee, Eung-Hyuk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.6_2
    • /
    • pp.971-977
    • /
    • 2020
  • In this paper, We propose a portable electrostatic meter which can measure high voltage static electricity caused by friction to prevent fire or explosion accidents in grinding, crushing, power injection, transport, filling, dust removal, painting, and foreign matter removal processes. The proposed device not only shows static electricity strength in 4 steps with respect to distance and voltage but also gives warning with a buzzer, on process facilities that are likely to generate high voltage static electricity due to friction. The device is implemented by filtering the signal detected by the wireless antenna, amplifying the signal by 6 times, and passing the signal through the integrator circuit. Tests are carried out with an electrostatic discharge simulator. And the results show that 4 LEDs are turned on at the distance of 10cm, 3 LEDs at 12cm, 2 LEDs at 13cm, and 1 LED at 15cm, when a fixed voltage of 500V is given. And also, the tests show that the static electricity can be detected at 5cm on 100V, 10cm on 200V, 15cm on 500V, 20cm on 1000V, and 25cm on 1500V. We expect to reduce accidents caused by static electricity by allowing safety managers on fields where fire or explosion accidents can happen to monitor static electricity.

Design of Simple Direct Comparison Measurement System from 10 MHz to 1 GHz for Thermistor Mounts Calibration (서미스터 마운트 교정을 위한 10 MHz에서 1 GHz 주파수 대역의 단순 직접 비교 측정시스템 설계)

  • Cha, Yun-Bae;Jang, Young-Guen;Kim, Boo-Il
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.3
    • /
    • pp.405-412
    • /
    • 2020
  • The thermistor mount is used for precise RF power measurement because the calibration factor is constant according to the change of power. The calibration factor of the standard mount can be measured with an uncertainty less than 0.5 % from the 10 MHz to 1 GHz by direct comparison with the transfer standard using the DC substitution method. Recently, as the supply of precision power meter based on DC substitution method allows simple and fast measurement, a simple direct comparison measurement system with the same level uncertainty was designed and the minimum required specifications of components through analysis of mismatch error was proposed. The uncertainty was evaluated for system validation, and the results show that uncertainties have been well maintained within 0.5 % in the measurement frequencies.

Implementation of Single-Phase Energy Measurement IC (단상 에너지 측정용 IC 구현)

  • Lee, Youn-Sung;Seo, Hae-Moon;Kim, Dong Ku
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.12
    • /
    • pp.2503-2510
    • /
    • 2015
  • This paper presents a single-phase energy measurement IC to measure electric power quantities. The entire IC includes two programmable gain amplifiers (PGAs), two ${\sum}{\Delta}$ modulators, a reference circuit, a low-dropout (LDO) regulator, a temperature sensor, a filter unit, a computation engine, a calibration control unit, registers, and an external interface block. The proposed energy measurement IC is fabricated with $0.18-{\mu}m$ CMOS technology and housed in a 32-pin quad-flat no-leads (QFN) package. It operates at a clock speed of 4,096 kHz and consumes 10 mW in 3.3 V supply.

Volume Resistivity Characteristics of Epoxy Resin using Nanocomposites (나노 컴퍼지트 에폭시 절연재료의 체적 고유저항 특성)

  • Choi, Hyun-Min;Kim, Joung-Sik;Kim, Won-Jong;Park, Young-Ha;Kim, Gwi-Yeol;Shin, Jong-Yeol;Lee, Jong-Yong;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.387-387
    • /
    • 2009
  • In the study the volume resistivity Characteristics of epoxy resin using nanocomposites, nano-comosites are made from insulating material epoxy resin using for power transformer equipment and molding several devices as changing amount of addition of diameter 12 [nm] $SiO_2$, we measured volume resistivity of nano-composites by High Resistance Meter(4329A). As the result of measurement, we have seen the epoxy resin using 1.6 [wt%] nanocomposites was the highest measured at the volume resistivity, and using 0.4 [wt%] nanocomposites was highest stabilized than others according to variable temperature properties.

  • PDF

Temperature Dependence of Volume Resistivity Characteristics for Nano Composit Epoxy (나노컴퍼지트 에폭시 체적고유저항의 온도의존성)

  • Lee, Dong-Gun;Back, Sung-Hak;Park, Tae-Hak;Park, Hong-Kyu;Jeong, In-Bum;Kim, Joung-Sik;Hong, Jin-Ung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.91-91
    • /
    • 2010
  • In this paper, nano composites material is produced by adding MgO with particle size of 5 [nm] into epoxy resign using as insulating material of power transformer apparatus and molding part to study the volume resistivity of nano composites used epoxy. We measured the volume resistivity using the High Resistance Meter(4329A) depending on changing the amount of addition and temperature in this experience. In result, we have confirmed that 1.0, 3.0, 5.0 and 10.0 [wt%] as about 2.9, 7.6, 7.5 and 6.1 times increased than virgin. Therefore, the characteristic of volume resistivity was relatively stable as specimen by added 3.0 [wt%] than the others.

  • PDF