• Title/Summary/Keyword: Electronic equipment

Search Result 1,561, Processing Time 0.023 seconds

An Experimental Study on the Effect of Supporting Vest for Musculoskeletal Disorders in Low Back (허리 근골격계질환 예방 보조 조끼의 효과에 대한 실험적 연구)

  • Kim, Yun-Jeong;Jang, Jee-Hun;Cho, Yoe-han;Jeong, Jin-Hyoung;Cheong, Ha-Young;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.3
    • /
    • pp.219-225
    • /
    • 2020
  • With the aging population, the prevalence of musculoskeletal disorders in the elderly continues to increase. In addition, musculoskeletal disorders are the third most common social and economic loss among occupational illnesses in Workers' compensation insurance benefits as of 2015 standard and are also common among workers. In this study, a vest that can assist in the prevention and treatment of musculoskeletal disorders of the waist was produced, and it is intended to confirm the presence or absence of the effect through experiments. Diseases of the waist are closely related to core muscles. Therefore, the produced vest was made in a form that supports the core muscles. Before and after wearing the vest for effectiveness verification, the While performing 10-times of the Mackenzie exercises, a waist extension exercise, collected the EMG data of the internal oblique, Rectus abdominis, and Erector spinae, which correspond to the core muscles. The collected data were analyzed through the electromyography analysis program RM-3 to obtain RMS values for 10-times measurements of each muscle and to compare the average values. After comparing the data, to verify the significance, the technical statistical value of the measurement result was calculated and the average difference was verified through PASW ver18.0, And the paired t-test is performed on the experimental results to perform statistical processing. and Statistical processing was performed by setting the significance level to α=.05.

Development of the Standard Model of a Stated Period Check and Precise Safety Diagnosis in the Research Lab for Prevention to Electrical Accidents (전기사고방지를 위한 연구실험실 정기점검/정밀안전진단 표준모델개발)

  • Lee, Dong-Yoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.858-864
    • /
    • 2011
  • There is no standard model for a Stated Period Check and a Precise Safety Diagnosis to remove electric fire and shock in the university Lab and institute. Especially, the research for the Stated Period Check and the Precise Safety Diagnosis of the Lab related to electrical field is very weak currently, and it is very necessary to build a detail safety plan. This paper informs the specific standard guideline of the safety check list, method and equipment and it shows the way to evaluate safety grade too. This paper also provides the information of R&D process through the analysis of electrical safety check list of ordinary R&D Lab. It shows a new detail guideline to R&D Lab, and the new guideline removes existing problem and deliver the effective standard model to each R&D Lab. The standard model developed in this research adopts the clear guideline of each check list for the electrical environment of current R&D Lab. This standard model can be applied for every R&D Lab to detect routine safety check and detail safety check immediately. This Research will generally improve not only the effective safety check, but also the safety level for R&D Lab to prevent the electrical accidents.

A Basic Study on Sorting of Black Plastics of Waste Electrical and Electronic Equipment (WEEE) (폐가전의 검정색 플라스틱 재질선별에 관한 기초 연구)

  • Park, Eun Kyu;Jung, Bam Bit;Choi, Woo Zin;Oh, Sung Kwun
    • Resources Recycling
    • /
    • v.26 no.1
    • /
    • pp.69-77
    • /
    • 2017
  • Used small household appliances(small e-waste) consists of a variety of complex materials and components. The small e-waste is mainly composed of plastics and an important potential source of waste plastic. The black plastics, particularly are very difficult to separate by resin type and therefore these are mainly recycled in the form of a mixtures. In the present study, the sorting technologies such as gravity and electro static separation, near-infrared ray(NIR) and IR/Raman optical sorting separation on mixture of black plastics were analyzed and their limitations on sorting process were also investigated. The Laser Induced Breakdown Spectroscopy(LIBS) spectrum of each black plastics was used for identification of black plastics by resin type, and after analyzing the normalization operation, Principal Component Analysis(PCA) was carried out. The spectrum data was optimized through PCA process. In order to improve the identification accuracy and sorting efficiency of black plastics, it is necessary to design a classifier with high efficiency and to improve the performance and reliability of the classifier by applying the field of intelligent algorithms.

Experimental Research for Traction force Sensor Development on Drawing Exercise Medical Instrument (재활 및 교정을 위한 견인운동치료기의 견인측정센서 개발에 관한 실험적 연구)

  • Lee, Sang-sik;Park, Won-yeop;Lee, Choong-ho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.2
    • /
    • pp.3-8
    • /
    • 2009
  • The traction system has been mainly used for rehabilitation and correction of patients with spine or gait diseases in orthopedics or at home. Some problems could occur in human body when patients forced their training using the traction system. So it needs to measure a traction force and control the training time. However, most of products on market have no sensor measuring traction force. Thus we designed and made a sensor detecting traction force using strain gauge, amplifier for transition to output signal and experiment devices for performance test. We carried out experiment of a sensor detecting a traction force and measured electric responses of it with respect to traction loads. Maximum error was within about 1% for experiments in static condition and the average error was about 0.7% for experiments in dynamic condition. We concluded that it is possible to use the developed sensor for measurement of traction force since the maximum output variation of a sensor detecting a traction force was about 0.3% in $0^{\circ}C-60^{\circ}C$ temperature condition.

  • PDF

A Photogrammetric Approach to Create 3-Dimensional Models of Irregular-shaped Curves (부정형 곡선의 3차원 모델 제작에 대한 사진측량적 접근)

  • Chang, Ji Hong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.6
    • /
    • pp.545-551
    • /
    • 2017
  • It is very important to effectively obtain the information related to the human body shape for user-centered design. The human body shape is a huge combination of various irregular curves and is typically obtained by a 3-D Scanner. 3-D scanners show high reliability; however, they are expnsive equipment with limited mobility. 3-D models of irregular-shaped curves were created by a photogrammetric approach and the errors between the original curve and the models were evaluated. 3-D models were created based on 160, 80, 40, 20, 10, and 5 marking points evenly located on the original curve. In the case of convex curve, low levels of residuals were observed in the models from 160, 80, 40, and 20 marking points (0.13% max). In the combination of convex and concave curves, relatively low levels of residuals were observed in the models from 160, 80, and 40 marking points (0.29%). It is possible to conclude that marking points should be placed at every 5% of overall length of a convex curve and at every 2.5% of overall length of a curve with convex and concave curve in order to maintain low levels of errors. A photogrammetric approach can be used as an alternative for the 3-D scanners with advantages of low cost and mobility.

A Study on Energy Efficiency Improvement through Building Insulation Diagnosis (건축물 단열 진단을 통한 에너지 효율 개선에 관한 연구)

  • Cho, Kwangmoon
    • Journal of Internet of Things and Convergence
    • /
    • v.7 no.3
    • /
    • pp.9-14
    • /
    • 2021
  • This paper discovers the energy loss factors through the insulation diagnosis of houses or buildings, and proposes directions for energy efficiency improvement. The energy efficiency factor of a building consists of insulation diagnosis, thermal bridge diagnosis, window diagnosis, airtight diagnosis, and equipment diagnosis. Among the residents and facilities in the energy welfare blind spot, an energy efficiency diagnosis was conducted for one senior citizen building located in Naju-si, Jeollanam-do, and energy efficiency diagnosis was conducted after insulation was installed. Energy measurement, diagnosis and analysis were performed using the IoT-based integrated wired/wireless energy diagnosis platform, Energy Finder. As a result of comparison, an overall energy saving rate of 16.38% was achieved. Annual heating energy consumption per unit area decreased from 333.51kWh before construction to 277.35kWh after construction, and annual cooling energy consumption per unit area decreased from 5.51kWh before construction to 5.22kWh after construction. The annual primary energy consumption per unit area decreased from 464.52kWh before construction to 403.69kWh after construction, and the annual energy cost was reduced from 3,063,307.14 won before construction to 2,641,072.49 won after construction. The additional improvement work is needed on the standards affecting energy efficiency other than insulation.

Remote Monitoring Panel and Control System for Chemical, Biological and Radiological Facilities (화생방 방호시설을 위한 원격감시 패널 및 제어시스템)

  • Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.464-469
    • /
    • 2019
  • A remote monitoring panel and control system was developed to control various valves and access control chambers, including gas shutoff valves used in CBR(Chemical, Biological and Radiological) facilities. The remote monitoring panel consisted of a main panel installed in the NBC (Nuclear, Biological and Chemical) control room and auxiliary panel installed in the clean room, and the size was divided into pure control and control including CCTV. This system can be monitored and controlled remotely according to the situation where an explosion door and gas barrier door can occur during war and during normal times. This system is divided into normal mode and war mode. In particular, it periodically senses the operation status of various valves, sensors, and filters in the CBR facilities to determine if each apparatus and equipment is in normal operation, and remotely alerts situation workers when repair or replacement is necessary. Damage due to the abnormal operation of each device in the situation can be prevented. This enables control of the blower, supply and exhaust damper, emergency generator, and coolant pump according to the state of shutoff valve and positive pressure valve in the occurrence of NBC, and prevents damage caused by abrupt inflow of conventional weapons and nuclear explosions.

Study on Compensation Method of Anisotropic H-field Antenna (Loran H-field 안테나의 지향성 보상 기법 연구)

  • Park, Sul-Gee;Son, Pyo-Woong
    • Journal of Navigation and Port Research
    • /
    • v.43 no.3
    • /
    • pp.172-178
    • /
    • 2019
  • Although the needs for providing resilient PNT information are increasing, threats due to the intentional RFI or space weather change are challenging to resolve. eLoran, which is a terrestrial navigation system that use a high-power signal is considered as a best back-up navigation system. Depending on the user's environment in the eLoran system, the user may use one of E-field or H-field antennas. H-field antenna, which has no restriction on setting stable ground and is relatively resistant to noise of general electronic equipment, is composed of two loops, and shows anisotropic gain pattern due to the different measurement at the two loops. Therefore, the H-field antenna's phase estimation value of signal varies depending on its direction even at the static environment. The error due to the direction of the signal should be eliminated if the user want to estimate the own position more precisely. In this paper, a method to compensate the error according to the geometric distribution between the H-field antenna and the transmitting station is proposed. A model was developed to compensate the directional error of H-field antenna based on the signal generated from the eLoran signal simulator. The model is then used to the survey measurement performed in the land area and verify its performance.

A Study on Heat Transfer and Pressure Drop Characteristics according to Block Size and Turbulence Generator's Placement in a Horizontal Channel (블록 크기 및 난류발생기 배치에 따른 수평채널내의 열전달 및 압력강하 특성에 관한 연구)

  • Seo, Kyu-Won;Lim, Jong-Han;Yoon, Jun-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.639-647
    • /
    • 2019
  • Recently, as the semiconductor integration technology due to miniaturization and high density of electronic equipment have developed, it is importantly recognized the application of thermal control system in order to release inner heat generated from chips, modules, In this study, we considered the heat transfer and pressure drop characteristics in a horizontal channel with four blocks using k-${\omega}$ SST turbulence model During CFD (Computational Fluid Dynamics) analysis, the parameters applied block width, block height, heat source and turbulence generator placement etc. As the boundary conditions of analysis, the channel inlet temperature and flow velocity were respectively 300 K and 3.84 m/s, the heat flux was $358W/m^2$. As a result, the heat transfer performance was decreased as the block width ratio (w/h) was increased, while it was increased as the block height ratio (h/w) was increased. In addition, as the arrangement of heat source size was increased to high heat flux from low heat flux, it was influenced by heat source size and the heat transfer coefficient showed a tendency to increase, When the turbulence generator was installed in the upper part of block No. 1 position the closely to the channel entrance, the heat transfer characteristics was greatly influenced on the whole of four heating blocks. and in oder to consider the pressure drop characteristics, we are able to select the most appropriate turbulence generator's position.

Pop-up Chart for Managing CRRT Improves the Quality of CRRT Care (전자의무기록 팝업차트를 활용한 CRRT 관리의 질향상 활동)

  • Go, Su-Ryeong;Lee, An-Na;Kim, Ki-Pyo;Chin, Ho-Jun;Na, Ki-Young;Chae, Dong-Wan;Kim, Se-Joong
    • Quality Improvement in Health Care
    • /
    • v.25 no.1
    • /
    • pp.43-51
    • /
    • 2019
  • Purpose: The time lag between the decision to initiate continuous renal replacement therapy (CRRT) and its actual initiation remains a major barrier in our intensive care units. We developed a CRRT pop-up chart on EMR for managing CRRT machines. Methods: This study measured time interval between the decision to prepare the CRRT machine and the actual use of the machine before and after using a CRRT pop-up chart. This study conducted a questionnaire of the medical staff to assess the changes in the quality of CRRT preparation. Results: A total of 95 patients on CRRT is analyzed. The time to find an available CRRT machine is decreased by 24.6%. The time to move a CRRT machine to the patient's bedside is decreased by 55.8%. Medical surveys of 44 nurses gave the following results. 1) The time to apprehend machines for 1 to 3 minutes is improved from 29.5% to 81.8%, and the time to apprehend machines over 3 minutes is decreased from 70.5% to 18.2%. 2) The number (6-all) of known machine locations is improved from 22.7% to 63.4%. 3) Interruption of a nurse's work due to telephone calls asking for the possession of movable CRRT equipment also is improved. Scores of 1-4 are improved from 15.9% to 41%. Scores of 5-7 are reduced from 52% to 15.9%. Conclusions: CRRT pop-up chart is shortened the time lag of CRRT machine preparation, reduced the nurse's phone workload and helped to improve the quality of CRRT care.