• 제목/요약/키워드: Electron-Beam Energy

검색결과 696건 처리시간 0.032초

Performance prediction of gamma electron vertex imaging (GEVI) system for interfractional range shift detection in spot scanning proton therapy

  • Kim, Sung Hun;Jeong, Jong Hwi;Ku, Youngmo;Jung, Jaerin;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.2213-2220
    • /
    • 2022
  • The maximum dose delivery at the end of the beam range provides the main advantage of using proton therapy. The range of the proton beam, however, is subject to uncertainties, which limit the clinical benefits of proton therapy and, therefore, accurate in vivo verification of the beam range is desirable. For the beam range verification in spot scanning proton therapy, a prompt gamma detection system, called as gamma electron vertex imaging (GEVI) system, is under development and, in the present study, the performance of the GEVI system in spot scanning proton therapy was predicted with Geant4 Monte Carlo simulations in terms of shift detection sensitivity, accuracy and precision. The simulation results indicated that the GEVI system can detect the interfractional range shifts down to 1 mm shift for the cases considered in the present study. The results also showed that both the evaluated accuracy and precision were less than 1-2 mm, except for the scenarios where we consider all spots in the energy layer for a local shifting. It was very encouraging results that the accuracy and precision satisfied the smallest distal safety margin of the investigated beam energy (i.e., 4.88 mm for 134.9 MeV).

The effect of ion to electron mass ratio on Ion beam driven instability and ion holes by PIC simulation

  • 홍진희;이은상;민경욱
    • 천문학회보
    • /
    • 제37권1호
    • /
    • pp.92.2-92.2
    • /
    • 2012
  • Previous simulations posed a problem that they used reduced ion to electron mass ratios to save computation time. It was assumed that ion and electron dynamics are sufficiently separated, but it was not clearly verified. In this study, we examine the effect of ion to electron mass ratios on the generation of ion holes by ion beam driven instability. Ion holes are generated via electron holes in an applied electric field with the given initial condition. First, the ion acoustic instability is excited and nonlinearly develops. After the ion acoustic instability nonlinearly develops, the ion two-stream instability is excited and develops into ion holes. This implies that the previously suggested ion beam driven instability is strongly affected by the coupling between ions and electrons and the ion to electron mass ratio is important on the development of the instability. The energy transition and detail variation is different as reduced mass ratio under the same observation value based on FAST satellite. Although, the parameters are rescaled by conserving the kinetic energy to obtain the proper results, the nonlinear evolution is not perfectly identical.

  • PDF

Development of a Wide Dose-Rate Range Electron Beam Irradiation System for Pre-Clinical Studies and Multi-Purpose Applications Using a Research Linear Accelerator

  • Jang, Kyoung Won;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Lee, Sang Jin;Kim, Jung Kee;Moon, Young Min;Kim, Jin Young;Jeong, Dong Hyeok
    • 한국의학물리학회지:의학물리
    • /
    • 제31권2호
    • /
    • pp.9-19
    • /
    • 2020
  • Purpose: This study aims to develop a multi-purpose electron beam irradiation device for preclinical research and material testing using the research electron linear accelerator installed at the Dongnam Institute of Radiological and Medical Sciences. Methods: The fabricated irradiation device comprises a dual scattering foil and collimator. The correct scattering foil thickness, in terms of the energy loss and beam profile uniformity, was determined using Monte Carlo calculations. The ion-chamber and radiochromic films were used to determine the reference dose-rate (Gy/s) and beam profiles as functions of the source to surface distance (SSD) and pulse frequency. Results: The dose-rates for the electron beams were evaluated for the range from 59.16 Gy/s to 5.22 cGy/s at SSDs of 40-120 cm, by controlling the pulse frequency. Furthermore, uniform dose distributions in the electron fields were achieved up to approximately 10 cm in diameter. An empirical formula for the systematic dose-rate calculation for the irradiation system was established using the measured data. Conclusions: A wide dose-rate range electron beam irradiation device was successfully developed in this study. The pre-clinical studies relating to FLASH radiotherapy to the conventional level were made available. Additionally, material studies were made available using a quantified irradiation system. Future studies are required to improve the energy, dose-rate, and field uniformity of the irradiation system.

Fabrication of Antibacterial Biodegradable films Using a Radiation-induced Reduction Method

  • Jung, Chan-Hee;Cho, Yong-Jun;Jung, Jin-Mook;Hwang, In-Tae
    • 방사선산업학회지
    • /
    • 제7권2_3호
    • /
    • pp.141-147
    • /
    • 2013
  • The simple and facile radiation technique of the preparation of antibacterial biodegradable polymer films containing silver nanoparticles (Ag NPs) was described. The biodegradable poly(butylene adipate-co-terephthalate) (PBAT) films containing silver trifluoroacetate (Ag TFA) were prepared by a solvent casting method, and then the films were irradiated by electron beams at the various doses ranging from 20 to 200 kGy to form Ag NPs in the biodegradable polymers. The results of UV-vis and FE-SEM/EDX analyses revealed that the Ag NPs were successfully formed in the PBAT matrix during the electron beam irradiation, and their amounts were dependant on the absorbed dose and Ag TFA concentrations. Furthermore, on the basis of the results of the antibacterial test through disk diffusion and colony counting test, the irradiated PBAT/Ag TFA films exhibited the antibacterial property due to the formation of Ag NPs.

515nm 피코초 레이저를 이용한 구리 어블레이션 공정의 최대 가공율에 대한 이론적 분석 (Theoretical analysis on the maximum volume ablation rate for copper ablation with a 515nm picosecond laser)

  • 신동식;조용권;손현기;서정
    • 한국레이저가공학회지
    • /
    • 제16권2호
    • /
    • pp.1-6
    • /
    • 2013
  • Picosecond lasers are a very effective tool for micromachining metals, especially when high accuracy, high surface roughness and no heat affected zone are required. However, low productivity has been a limit to broadening the spectrum of their industrial applications. Recently it was reported that in the micromachining of copper with a 1064nm picosecond laser, there exist the optimal pulse energy and repetition rate to achieve the maximum volume ablation rate. In this paper, we used a 515nm picosecond laser, which is more efficient for micromachining copper in terms of laser energy absorption, to obtain its optimal pulse energy and repetition rate. Theoretical analysis based on the experimental data on copper ablation showed that using a 515nm picosecond laser instead of a 1064nm picosecond laser is more favorable in that the calculated threshold fluence is 75% lower and optical penetration depth is 50% deeper.

  • PDF

Oxygen Ion Beam Assisted Deposition법에 의해 형성된 AC PDP용 MgO 보호막의 특성 연구 (Study of a MgO Protective Layer Deposited with Oxygen Ion Beam Assisted Deposition in an AC PDP)

  • 권상직;이조휘
    • 한국전기전자재료학회논문지
    • /
    • 제20권7호
    • /
    • pp.615-619
    • /
    • 2007
  • MgO layer plays an important role for plasma display panels (PDPs). In this experiment, ion beam assisted deposition (IBAD) methode was uesed to deposit a MgO thin film and the assisting oxygen ion beam energy was varied from 100 eV to 500 eV. In order to investigate the relationship between the secondary electron emission and the defect levels of the MgO layer, we measured the cathodoluminescence (CL) spectra of the MgO thin films, and we analyzed the CL peak intensity and peak transition. The results showed that the assisting ion beam energy played an important role in the peak intensity and the peak transition of the CL spectrum. The properties of MgO thin film were also analyzed using XRD and SEM, these results showed the assisting ion beam energy had direct effect on characteristics of MgO thin film.

Reflection High Energy Electron Diffraction이 결합된 Laser Molecular Beam Epitaxy System에서 $BaTiO_3/SrTiO_3$ 산화물 인공격자의 Layer-by-Layer 성장 (Atomic Layer-by-Layer Growth of $BaTiO_3/SrTiO_3$ Oxide Artificial Lattice in Laser Molecular Beam Epitaxy System Combined Reflection High Energy Electron Diffraction)

  • 이창훈;김이준;전성진;김주호;최택집;이재찬
    • 한국세라믹학회:학술대회논문집
    • /
    • 한국세라믹학회 2003년도 추계총회 및 연구발표회 초록집
    • /
    • pp.179.2-179
    • /
    • 2003
  • PDF

나노패터닝을 위한 고에너지 전자빔 리소그래피 시뮬레이터 개발 및 검증 (A Simulator for High Energy E-beam Lithography for Nano-Patterning)

  • 김진광;김학;한창호;전국진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 하계종합학술대회 논문집(2)
    • /
    • pp.359-362
    • /
    • 2004
  • Electron beam on high energy acceleration, which travels deeply and sharply through photoresist, became to be used in e-beam lithography apparatus for nano-patterning in due to its high resolution. An advanced electron beam lithography simulation tool is currently undergoing development for nano-patterning. This paper will demonstrate such simulation efforts with experiments at 200 keV e-beam lithography processes on PMMA, ZEP520 of which photoresist parameters and characteristics will be explained with simulation results. Neureuther parameters was extracted from the contrast curve of the resist

  • PDF

고에너지 전자선 측정을 위한 광섬유 방사선 센서에서의 체렌코프 빛 측정 및 분석 (Measurements and characterizations of cerenkov light in fiber-optic radiation sensor irradiated by high energy electron beam)

  • 장경원;조동현;정순철;전재훈;이봉수;김신;조효성;박성용;신동호
    • 센서학회지
    • /
    • 제15권3호
    • /
    • pp.186-191
    • /
    • 2006
  • In general, Cerenkov light is produced by a charged particle that passes through a medium with a velocity greater than that of visible light. Although the wavelength of Cerenkov light is very broad, the peak is in the almost visible range from 400 to 480 nm. Therefore, it always causes a problem to detect a real light signal that is generated in the scintillator on the fiber-optic sensor tip for dose measurements of high-energy electron beam. The objectives of this study are to measure, characterize and remove Cerenkov light generated in a fiber-optic radiation sensor tip to detect a real light signal from the scintillator. In this study, the intensity of Cerenkov light is measured and characterized as a function of incident angle of electron beam from a LINAC, and as a function of the energy of electron beam. As a measuring device, a photodiode-amplifier system is used, and a subtraction method using a background optical fiber is investigated to remove Cerenkov light.

감마선 및 전자선 조사에 따른 톳 자숙액 에탄올 추출물의 색상 및 생물학적 활성 변화 비교 (The Comparison of Color and Physiological Properties of Hizikia fusiformis Cooking Juice Ethanol Extract Irradiated with Gamma Ray and Electron Beam)

  • 최종일;김현주
    • KSBB Journal
    • /
    • 제27권3호
    • /
    • pp.195-198
    • /
    • 2012
  • This study was carried out to assess the effect of radiation on the changes of Hizikia fusiformis cooking juice ethanol extract and to compare the effect of gamma ray and electron beam. On the applying radiation, the dark color of cooking juice became changed with higher brightness and lower redness and yellowness. But, there was no difference between gamma ray radiation and electron beam radiation. 1,1-Diphenyl-2-picryl-hydrazyl radical scavenging activity and tyrosinase inhibitory activity of cooking juice were shown to be increased by radiation independent on the radiation source types. The reason for the increased biological activities was caused by higher content of total phenolic compounds. The results could be applied to investigate the effect of radiation source on the color and antioxidant activity of biomaterials, and it was thought that irradiation could be an promising method for enhancing the biological activity of biomaterials.