• Title/Summary/Keyword: Electron-Beam Characteristics

Search Result 406, Processing Time 0.025 seconds

Dose Characteristics for IORT Applicator of ML-15MDX Electron Beam (ML-15MDX 술중조사용 Applicator에 의한 전자선선량 특성)

  • Choi, Tae-Jin;Lee, Ho-Joon;Kim, Yeung-Ae;Kim, Jin-Hee;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.455-461
    • /
    • 1993
  • Experimental measurements of dose characteristics with pentagonal applicator at nominal energy of 4, 6, 9, 12 and 15 MeV electron beam were performed for intraoperative radiotherapy (IORT) in ML-15MDX linear accelerator. This paper presents the percent depth dose, surface dose, beam flatness and output factors of using the IORT applicator in different electron beam energy. The output factor showed as a 24 percent higher in IORT applicator than that of reference $10{\times}10cm^2$ applicator. The surface dose of using the IORT applicator showed 7.7 and 2.7 percent higher than that of reference field in 4 and 15 MeV electron beam, respectively. In our experiments, the variation of percent depth dose was very small but the output factor and flatnees at 0.5 cm depth have showed a large value in IORT applicator.

  • PDF

Preliminary Study on Improvement of Surface Characteristics of Stellite21 Deposited Layer by Powder Feeding Type of Direct Energy Deposition Process Using Plasma Electron Beam (플라즈마 전자빔을 이용한 분말공급형 직접식 에너지 적층 공정으로 제작된 Stellite21 적층층의 표면 특성 개선에 관한 기초 연구)

  • Kim, Dong-In;Lee, Ho-Jin;Ahn, Dong-Gyu;Kim, Jin-Seok;Kang, Eun Goo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.11
    • /
    • pp.951-959
    • /
    • 2016
  • The aim of this paper is to investigate the improvement of surface characteristics of Stellite21 deposited layer by powder feeding type of direct energy deposition (DED) process using a plasma electron beam. Re-melting experiments of the deposited specimen is performed using a three-dimensional finishing system with a plasma electron beam. The acceleration voltage and the travel speed of the electron beam are chosen as process parameters. The effects of the process parameters on the surface roughness and the hardness of the re-melted region are examined. The formation of the re-melted region is observed using an optical microscope. Results of these experiments revealed that the re-melting process using a plasma electron beam can greatly improve the surface qualities of the Stellite21 deposited layer by the DED process.

Chemical and Thermal Characterizations of Electron Beam Irradiated Jute Fibers (전자빔 조사된 황마섬유의 화학적 및 열적 특성분석)

  • Ji, Sang Gyu;Cho, Donghwan;Lee, Byung Cheol
    • Journal of Adhesion and Interface
    • /
    • v.11 no.4
    • /
    • pp.162-167
    • /
    • 2010
  • In the present work, the effect of electron beam irradiation on the chemical and thermal characteristics of cellulose-based jute fibers was explored by means of chemical analysis, electron spin resonance analysis, ATR-FTIR spectroscopy, thermogravimetric analysis and thermomechanical analysis. Jute fiber bundles were uniformly irradiated in the range of 2~100 kGy by a continuous method using a conveyor cartin an electron beam tunnel. Electron beam treatment, which is a physical approach to change the surfaces, more or less changed the chemical composition of jute fibers. It was also found that the radicals on the jute fibers can be increasingly formed with increasing electron beam intensity. However, the electron beam irradiation did not change significantly the chemical functional groups existing on the jute fiber surfaces. The electron beam irradiation influenced the thermal stability and thermal shrinkage/expansion behavior and the behavior depended on the electron beam intensity.

Effects of Electron-Beam Irradiation on Color and Organoleptic Qualities of Ginseng Powders (Electron Beam 조사가 인삼분말의 색도 및 관능적 품질에 미치는 영향)

  • Lee, Mi-Gyeong;Gwon, Jung-Ho;Do, Jae-Ho
    • Journal of Ginseng Research
    • /
    • v.22 no.4
    • /
    • pp.252-259
    • /
    • 1998
  • Electron beam, electrically produced from an electron accelerator, was compared with gamma energy in terms of its influence on color and organoleptic qualities of ginseng powders when exposed to the energy used for their microbial decontamination. Hunter color L and b values were suitable for measuring color characteristics of ginseng powders, which were not significantly changed by the exposure to 5 to 7.5 kGy electron beam and gamma energy. Fifty percent ethanol extracts of irradiated ginseng powders at 10 key showed negligible differences from the non-irradiated control in the pattern of absorption spectra at 280∼800 am, but showed increased values in overall color difference (AE) as compared with powdered samples. Irradiation more than 10 kGy and storage at ambient temperature for 4 months caused browning of powdered samples. Irradiation at more than 10 kGy of electron beam was found a critical level to bring about appreciable changes (p<0.05) in or-ganoleptic qualities such as color and odor of sterilized samples, and red ginseng powder was more susceptible than white one to organoleptic changes by irradiation.

  • PDF

Study on Characteristics of Dose Distribution in Tissue of High Energy Electron Beam for Radiation Therapy (방사선 치료용 고에너지 전자선의 조직 내 선량분포 특성에 관한 연구)

  • Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.175-186
    • /
    • 2002
  • The purpose of this study is directly measure and evaluate about absorbed dose change according to nominal energy and electron cone or medical accelerator on isodose curve, percentage depth dose, contaminated X-ray, inhomogeneous tissue, oblique surface and irradiation on intracavitary that electron beam with high energy distributed in tissue, and it settled standard data of hish energy electron beam treatment, and offer to exactly data for new dote distribution modeling study based on experimental resuls and theory. Electron beam with hish energy of $6{\sim}20$ MeV is used that generated from medical linear accelerator (Clinac 2100C/D, Varian) for the experiment, andwater phantom and Farmer chamber md Markus chamber und for absorbe d dose measurement of electron beam, and standard absorbed dose is calculated by standard measurements of International Atomic Energy Agency(IAEA) TRS 277. Dose analyzer (700i dose distribution analyzer, Wellhofer), film (X-OmatV, Kodak), external cone, intracavitary cone, cork, animal compact bone and air were used for don distribution measurement. As the results of absorbed dose ratio increased while irradiation field was increased, it appeared maximum at some irradiation field size and decreased though irradiation field size was more increased, and it decreased greatly while energy of electron beam was increased, and scattered dose on wall of electron cone was the cause. In percentage depth dose curve of electron beam, Effective depth dose(R80) for nominal energy of 6, 9, 12, 16 and 20 MeV are 1.85, 2.93, 4.07, 5.37 and 6.53 cm respectively, which seems to be one third of electron beam energy (MeV). Contaminated X-ray was generated from interaction between electron beam with high energy and material, and it was about $0.3{\sim}2.3\%$ of maximum dose and increased with increasing energy. Change of depth dose ratio of electron beam was compared with theory by Monte Carlo simulation, and calculation and measured value by Pencil beam model reciprocally, and percentage depth dose and measured value by Pencil beam were agreed almost, however, there were a little lack on build up area and error increased in pendulum and multi treatment since there was no contaminated X-ray part. Percentage depth dose calculated by Monte Carlo simulation appeared to be less from all part except maximum dose area from the curve. The change of percentage depth dose by inhomogeneous tissue, maximum range after penetration the 1 cm bone was moved 1 cm toward to surface then polystyrene phantom. In case of 1 cm and 2 cm cork, it was moved 0.5 cm and 1 cm toward to depth, respectively. In case of air, practical range was extended toward depth without energy loss. Irradiation on intracavitary is using straight and beveled type cones of 2.5, 3.0, 3.5 $cm{\phi}$, and maximum and effective $80\%$ dose depth increases while electron beam energy and size of electron cone increase. In case of contaminated X-ray, as the energy increase, straight type cones were more highly appeared then beveled type. The output factor of intracavitary small field electron cone was $15{\sim}86\%$ of standard external electron cone($15{\times}15cm^2$) and straight type was slightly higher then beveled type.

  • PDF

A Consideration on the Characteristics of Electron Beam Dose Distributions for Clinical Applications (임상적용을 위한 전자선의 선량분포 특성에 대한 고찰)

  • Cha, Dong-Soo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.65-69
    • /
    • 2010
  • High energy electron beams were to concentrically dose inside a tumor and more energy is a shape decreased of dose. Therefore, it is useful to radiation therapy of a tumor. Also high energy electron beams ionized into collision with a atom in structure material of tissue and it has big changes to dose distribution by multiple scattering. The study had to establish characteristic of electron beams from interaction of electron beams and materials. Experiment method was to measure dependence of electron beam central axis for depth dose curve, field flatness and symmetry and field size dependence. The results were able to evaluate data for a datum pint of electron beam. Also radiotherapy has to be considered for not only energy pencil of lines but characteristic, electron guide and isodose curves distribution.

  • PDF

Investigations on electron beam weldability of AlZnMgCu0.5 alloys (AlZnMgCu0.5 합금의 Electron Beam 용접성에 관한 연구)

  • 배석천
    • Journal of Welding and Joining
    • /
    • v.15 no.4
    • /
    • pp.166-177
    • /
    • 1997
  • The high strength AlZnMgCu0.5 alloy is a light metal with good age hardenability, and has a high tensile and yielding strength. Therefore, it can be used for structures requiring high speciple strength. Even though high strength AlZnMgCu alloy has good mechanical properties, it has a lot of problems in TIG and MIG welding processes. Since lots of high heat absorption is introduced into the weldment during TIG and MIG processes, the microstructural variation and hot cracks take place in heat affected zone. Therefore, the mechanical properties of high strength AlZnMgCu0.5 alloy can be degraded in weldment and heat affected zone. Welding process utilizing high density heat source such as electron beam should be developed to reduce pore and hot cracking, whichare usually accompanied by MIG and TIG welding processes. In this work, electron beam welding process were used with or without AlMg4.5Mn as filler material to avoid the degradation of mechanical properties. Mechanical and metallurgical characteristics were also studied in electron beam weldment and heat affected zone. Moreover hot cracking mechanism was also investigated.

  • PDF

Volume Resistivity Characteristics of Low Density Polyethylene film irradiated with Electron Beam (전자선 조사된 저밀도 폴리에틸렌 박막의 체적고유저항 특성)

  • Cho, Don-Chan;Cho, Kyung-Soon;Lee, Soo-Won;Kim, Wang-Kon;Hong, Jin-Wooog
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.193-195
    • /
    • 1996
  • Low-density polyethylene(LDPE ; thickness 100[${\mu}m$] as a experimental specimen is irradiated with electron beam by using electron beam accelerator, and as an experimental specimen, the nonirradiated specimen and the specimen irradiated with electron beam is produced according to the classification of dose. From the analysis of DSC, the crystalline melting point of the specimen irradiated with electron beam is lower than that of virgin specimen. It is confirmed thai the volume resistivity is increased from the temperature over $50[^{\circ}C]{\sim}60[^{\circ}C]$ to the crystalline melting point because of the defects of solid structure and the formation of many trap centers by means of electron beam irradiation, but decreased in the temperature over the crystalline melting point because of the melt of crystalline.

  • PDF

Optimal Electron Beam Characteristics by Lenses Analysis Using Scanning Electron Microscopy (주사전자현미경 렌즈의 해석을 통한 최적의 빔 특성 연구)

  • Bae, Jinho;Kim, Dong Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • This paper presents a design method for optimizing the focused beam characteristics, which are mainly determined by the condenser lenses in a scanning electron microscopy (SEM) design. Sharply reducing the probe diameter of electron beams by focusing the condenser lens (i.e., the rate of condensation) is important because a small probe diameter results in high-performance demagnification. This study explored design parameters that contribute to increasing the SEM resolution efficiently using lens analysis and the ray tracing method. A sensitivity analysis was conducted based on those results to compare the effects of these parameters on beam focusing. The results of this analysis on the design parameters for the beam characteristics can be employed as basic key information for designing a column in SEM.

Effect of Target Angle and Thickness on the Heel Effect and X-ray Intensity Characteristics for 70 kV X-ray Tube Target

  • Kim, Gyehong;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.272-276
    • /
    • 2016
  • To investigate the optimum x-ray tube design for the dental radiology, factors affecting x-ray beam characteristics such as tungsten target thickness and anode angle were evaluated. Another goal of the study was to addresses the anode heel effect and off-axis spectra for different target angles. MCNPX has been utilized to simulate the diagnostic x-ray tube with the aim of predicting optimum target angle and angular distribution of x-ray intensity around the x-ray target. For simulation of x-ray spectra, MCNPX was run in photon and electron using default values for PHYS:P and PHYS:E cards to enable full electron and photon transport. The x-ray tube consists of an evacuated 1 mm alumina envelope containing a tungsten anode embedded in a copper part. The envelope is encased in lead shield with an opening window. MCNPX simulations were run for x-ray tube potentials of 70 kV. A monoenergetic electron source at the distance of 2 cm from the anode surface was considered. The electron beam diameter was 0.3 mm striking on the focal spot. In this work, the optimum thickness of tungsten target was $3{\mu}m$ for the 70 kV electron potential. To determine the angle with the highest photon intensity per initial electron striking on the target, the x-ray intensity per initial electron was calculated for different tungsten target angles. The optimum anode angle based only on x-ray beam flatness was 35 degree. It should be mentioned that there is a considerable trade-off between anode angle which determines the focal spot size and geometric penumbra. The optimized thickness of a target material was calculated to maximize the x-ray intensity produced from a tungsten target materials for a 70 keV electron energy. Our results also showed that the anode angle has an influencing effect on heel effect and beam intensity across the beam.