• 제목/요약/키워드: Electron linac

검색결과 59건 처리시간 0.02초

4세대방사광가속기 진공시스템 (Vacuum system for PAL-XFEL)

  • 나동현
    • 진공이야기
    • /
    • 제4권1호
    • /
    • pp.12-15
    • /
    • 2017
  • The Pohang Accelerator Laboratory X-ray Free Electron Laser (PAL-XFEL) is a 0.1 nm hard X-ray FEL which aims at providing photon flux higher than $1{\times}10^{12}$ photons/pulse using a 10-GeV electron linac. The vacuum system of the machine consists of an injector section including an S-band photocathode RF gun, 10-GeV electron linac section based on S-band normal conducting accelerating structures and a 150-m long out-vacuum undulator system. We introduce the present status of PAL-XFEL vacuum systems.

PULSED NEUTRON FACILITY BASED ON AN ELECTRON LINAC

  • Kim, Guin-Yun;Son, Dong-Chul;Lee, Young-Seok;Ko, In-Soo;Cho, Moo-Hyun;Namkung, Won;Chang, Jong-Hwa
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.327-331
    • /
    • 2001
  • The Pohang Neutron Facility based on an electron linac was constructed in order to construct the infrastructure for nuclear data production in Korea. It consists of a 100-MeV electron linac, a water-cooled Ta target, and an 11-m time-of-flight path. We measured the time-of-flight path length, the neutron energy spectra for different water levels inside the moderator, and the neutron total cross sections of polyethylene and copper by the transmission method.

  • PDF

X-ray 컨테이너 화물검색시스템의 전자선형가속기 주변 콘크리트 차폐벽 내 방사화생성물에 대한 몬테카를로법 평가 (Monte carlo estimation of activation products induced in concrete shielding around electron linac used in an X-ray container inspection system)

  • 조영호
    • 한국산학기술학회논문지
    • /
    • 제11권3호
    • /
    • pp.1035-1039
    • /
    • 2010
  • 고에너지 X-ray를 투시 방사선원으로 사용한 컨테이너 화물검색시스템에서 생성되는 광중성자에 의해 주변 콘크리트 차폐벽에서 발생되는 방사화생성물을 평가하였다. 몬테카를로 전산해석 코드인 MCNPX2.5.0을 사용하였으며, 참조시스템은 국내 주요 항만에 설치된 9MeV X-ray 고정식 양방향 컨테이너 화물검색시스템이다. 9MeV X-ray 조사에 따라 생성되는 광중성자의 (n,$\gamma$) 반응에 의한 방사화생성물 재고량을 계산하고 이에 따라 야기되는 방사선 피폭선량을 계산하였다.

Measurement of undesirable neutron spectrum in a 120 MeV linac

  • Yihong Yan ;Xinjian Tan;Xiufeng Weng ;Xiaodong Zhang ;Zhikai Zhang ;Weiqiang Sun ;Guang Hu ;Huasi Hu
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3591-3598
    • /
    • 2023
  • Photoneutron background spectroscopy observations at linac are essential for directing accelerator shielding and subtracting background signals. Therefore, we constructed a Bonner Sphere Spectrometer (BSS) system based on an array of BF3 gas proportional counter tubes. Initially, the response of the BSS system was simulated using the MCNP5 code. Next, the response of the system was calibrated by using neutrons with energies of 2.86 MeV and 14.84 MeV. Then, the system was employed to measure the spectrum of the 241Am-Be neutron source, and the results were unfolded by using the Gravel and EM algorithms. Using the validated system, the undesirable neutron spectrum of the 120 MeV electron linac was finally measured and acquired. In addition, it is demonstrated that the equivalent undesirable neutron dose at a distance of 3.2 m from the linac is 19.7 mSv/h. The results measured by the above methods could provide guidance for linac-related research.

PHOTO-NEUTRON SOURCE USING 2 GEV ELECTRON LINAC FOR RADIATION SHIELDING RESEARCH

  • Lee, Hee-Seock;Bak, Joo-Shik;Chung, Chin-Wha;Ban, Syuichi;Shin, Kazuo;Sato, Tatsuhiko
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.333-335
    • /
    • 2001
  • The 2 GeV electron linac, the injector of the Pohang Light Source, was used as a photo-neutron source for radiation shielding research. The operational beam parameters are the nominal electron intensity of $0.5\;{\sim}5\;nC/sec$, the repetition rate of 10 Hz, and the beam pulse length of 1.0 nsec. One electron beam line was modified in order to install the target systems for producing pulsed photo-neutrons. The neutron spectrum and intensity were investigated by the time-of-flight technique. The reliable maximum energy of the measured neutrons was about 500 MeV. The number of neutrons above 20 MeV produced by one 1 GeV electron in a thick Pb target was about $6.45{\times}10^{-4}/sr$ at 90 degrees to the beam axis. The status of the photo-neutron source and the application research are presented.

  • PDF

Electron Energy Distribution for a Research Electron LINAC

  • Lim, Heuijin;Lee, Manwoo;Yi, Jungyu;Kang, Sang Koo;Kim, Me Young;Jeong, Dong Hyeok
    • 한국의학물리학회지:의학물리
    • /
    • 제28권2호
    • /
    • pp.49-53
    • /
    • 2017
  • The energy distribution was calculated for an electron beam from an electron linear accelerator developed for medical applications using computational methods. The depth dose data for monoenergetic electrons from 0.1 MeV to 8.0 MeV were calculated by the DOSXYZ/nrc code. The calculated data were used to generate the energy distribution from the measured depth dose data by numerical iterations. The measured data in a previous work and an in-house computer program were used for the generation of energy distribution. As results, the mean energy and most probable energy of the energy distribution were 5.7 MeV and 6.2 MeV, respectively. These two values agreed with those determined by the IAEA dosimetry protocol using the measured depth dose.

Vacuum system for PAL-XFEL

  • 나동현;하태균;박종도
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.110.2-110.2
    • /
    • 2016
  • 4세대 방사광가속기는 0.1nm급 X-선 자유전자레이저(X-ray Free Electron Laser : XFEL) 광원을 빔라인 사용자들에게 제공하기 위하여 2011년 건설을 시작하였고, 2015년부터 장치를 설치하기 시작했으며 현재 건설 완료단계에 이르러 있다. 이 장치에서 진공시스템은 10-11 mbar의 초고진공이 요구되는 전자빔 발생장치인 RF Gun을 포함하는 입사장치구간(Injector)과 전체길이 800 m에 이르는 전자빔을 가속시키는 선형가속기구간(Linac) 그리고 결맞음 방사광을 발생시키는 언듈레이터구간으로 나눌 수 있다. 본 논문에서는 각 구간별 진공시스템에 대한 건설 현황에 대하여 보고하고자 한다.

  • PDF

연구용 선형가속기의 전자총 가열 전류에 따른 전자선의 에너지 인자 측정과 출력 측정 연구 (Measurement of Energy Parameters for Electron Gun Heater Currents and Output Dose Rate for Electron Beams from a Prototype Linac)

  • 임희진;이만우;김미영;이준규;이무진;강상구;이동주;정동혁
    • 한국의학물리학회지:의학물리
    • /
    • 제27권1호
    • /
    • pp.25-30
    • /
    • 2016
  • 본 연구에서는 의료용 선형가속기 제작을 위해 개발된 연구용 선형가속기의 전자선에 대한 선량학적 특성을 실험적으로 평가하였다. 본 논문에서는 전자총 가열 전류에 따른 에너지의 변화와 출력 흡수선량 측정 결과를 보고하고자 한다. 전자선의 에너지는 필름 측정법을 써서 평균에너지와 최빈에너지의 관점에서 결정하였다. 출력 흡수선량은 최적 에너지에 대하여 평행평판형 전리함을 사용하여 물속 깊이선량율을 측정하고 TRS-398 프로토콜에 따라 결정하였다. 측정 결과 전자총 가열 전류 2.02~2.50 A에서 평균에너지와 최빈에너지는 5.94~2.80 MeV와 6.54~3.31 MeV로 변화하였다. 그리고 평균에너지 5.94 MeV의 전자선에 대해 물속 기준 깊이에서 출력 흡수선량은 5.41 Gy/min으로 나타났다.

콤팩트 전자 선형가속기 시작품의 출력측정에 관한 연구 (Measurement of Electron Beam Output for the Prototype Compact Linac)

  • 김성우;강상구;이동주;임희진;이만우;이준규;이무진;양광모;노태익;정동혁
    • 한국의학물리학회지:의학물리
    • /
    • 제26권1호
    • /
    • pp.1-5
    • /
    • 2015
  • 의료용 및 산업용으로 활용하기 위한 C-밴드형 콤팩트 선형가속기의 개발이 동남권원자력의학원에서 진행되고 있다. 본 논문에서는 선형가속기 시작품에서 발생한 전자빔의 출력 측정 결과를 보고하고자 한다. 출력 측정은 물흡수선량에 대해 교정된 Exradin-A10 마커스형 평행평판형 전리함을 사용하여 물속 기준 깊이에서 IAEA TRS-398 프로토콜에 따라 흡수선량율을 결정하는 과정으로 진행되었다. 전자선 에너지가 낮은 점으로 인하여 선질지표($R_{50}$)은 필름 측정법을 써서 근사적으로 결정하였다. 결과로서 단위 펄스 진동수당의 선형가속기 전자빔의 출력은 $17.0cGy/(min{\cdot}Hz$로 나타났다. 본 연구의 결과는 개발 중인 전자가속기의 성능 평가 자료로 활용될 것이다.

STUDY ON X-RAYS AND NEUTRONS LEAKED FROM A 45 MeV ELECTRON LINAC FACILITY

  • Sawamura, Sadashi;Kitaichi, Masatoshi;Nojiri, Ichiro;Yamada, Takuma;Kaneko, Junichi;Sawamura, Teruko
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.133-137
    • /
    • 2001
  • Spatial and time distributions of x-rays and neutrons from Hokkaido University 45 MeV electron linac facility were measured and compared with the calculation. In the calculation, x-rays in a Pb-target were evaluated using the EGS-code. The x-rays and the neutrons from the target to the facility building boundary and skyshine process outside the facility building were simulated with the EGS and the MCNP respectively.

  • PDF