• Title/Summary/Keyword: Electron Monte Carlo

Search Result 239, Processing Time 0.022 seconds

The simulation on dose distributions of high energy electron beams. (고에너지 전자선의 선량분포에 관한 모의계산)

  • Lee, Jeong-Ok;Kim, Seung-Kon
    • Journal of radiological science and technology
    • /
    • v.25 no.1
    • /
    • pp.83-88
    • /
    • 2002
  • This work was peformed as a basic research in the application of Monte Carlo methods for planning treatments by electron beams. Depth doses, beam profiles and isodose curves in water phantoms were calculated for monoenergetic electron beams with 6, 9, and 12 MeV. The calculated depth doses and beam profiles are almost consistent with their known values. If allowances are made for distributions in electron beam energies, we are confident that the agreement between our calculations and measured values will significantly improve. In conclusion, our work shows that similar Monte Carlo calculations could be applied for geometries In human body in planning electron beam treatments.

  • PDF

A Monte-Carlo method and Boltzmann Equation analysis on the electron swarm parameter in SiH$_4$+Ar mixtures gas. ($SiH_4+Ar$ 혼합기체의 전자군 파라미터에 대한 볼츠만 방정식 및 몬테 칼로법 해석)

  • 김대연;하성철
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.387-390
    • /
    • 1999
  • Electron swarm parameterdthe drift velocity and longitudinal diffusion coefficienthn $SiH_4-Ar$ mixtures containing 0.5% and 5% monosilane were measured using over the range of E/N from 0.01 to 300 Td at room temperature. Electron swarm parameters in argon were drastically changed by adding a small amount of monosilane. The electron drift velocity in both mixtures showed unusual behaviour against E/N. It had negative slope in the medium range of E/N, yet the slope was not smooth but contained a small hump. The longitudinal diffusion coefficient also showed a corresponding feature in its dependence on E/N. A two-tern approximation of the Boltzmann equation analysis and Monte Carlo simulation have been used to study electron transport coefficients.

  • PDF

Determination of Quality Correction Factors for a Plane-Parallel Chamber in High Energy Electron Beams using Monte Carlo Calculation (몬테칼로 계산을 이용한 평판형 전리함의 고에너지 전자선에 대한 선질보정인자 결정)

  • Jeong, Dong-Hyeok;Lee, Jeong-Ok
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.89-95
    • /
    • 2008
  • The quality correction factor for used beam and qualities is strongly required for clinical dosimetry by TRS-398 protocol of IAEA. In this study the quality correction factors for a commercial plane-parallel ionization chamber in high energy electron beams were calculated by Monte Carlo code(DOSRZnrc/EGSnrc). In comparison of quality correction factor, the difference between this study and TRS-398 were within 1% in 5-20 MeV. In case of 4MeV the difference was 1.9%. As an independent method of determination of quality correction factor this study can be applied to evaluate values in the protocol or calculate the factor for a new chamber.

  • PDF

Electron Mean Energy in CF4, CH4, Ar mixtures (CF4, CH4, Ar 혼합기체의 전자 평균에너지)

  • Kim, Sang-Nam
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.241-245
    • /
    • 2015
  • Energy Distribution Function in pure $CH_4$, $CF_4$ and mixtures of $CF_4$ and Ar, have been analyzed over a range of the reduced electric field strength between 0.1 and 350[Td] by the two-term approximation of the Boltzmann equation (BEq.) method and the Monte Carlo simulation (MCS). The calculations of electron swarm parameters require the knowledge of several collision cross-sections of electron beam. Thus, published momentum transfer, ionization, vibration, attachment, electronic excitation, and dissociation cross-sections of electrons for $CH_4$, $CF_4$ and Ar, were used. The differences of the transport coefficients of electrons in $CH_4$, mixtures of $CH_4$ and Ar, have been explained by the deduced energy distribution functions for electrons and the complete collision cross-sections for electrons. The results of the Boltzmann equation and the Monte Carlo simulation have been compared with the data presented by several workers. The deduced transport coefficients for electrons agree reasonably well with the experimental and simulation data obtained by Nakamura and Hayashi. The energy distribution function of electrons in $CF_4$-Ar mixtures shows the Maxwellian distribution for energy. That is, $f({\varepsilon})$ has the symmetrical shape whose axis of symmetry is a most probably energy.

Monte carlo estimation of activation products induced in concrete shielding around electron linac used in an X-ray container inspection system (X-ray 컨테이너 화물검색시스템의 전자선형가속기 주변 콘크리트 차폐벽 내 방사화생성물에 대한 몬테카를로법 평가)

  • Cho, Young-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.1035-1039
    • /
    • 2010
  • Activation products generated by photoneutrons in concrete shielding wall around electron linac were estimated for a high energy X-ray container cargo inspection system. Monte carlo code, MCNPX2.5.0 was used for reference system of 9MeV fixed type dual-direction container cargo inspection system installed at major harbors in Korea. Activation products inventory generated by photoneutron (n,$\gamma$) reaction are estimated, and then radiation dose rate is calculated from the results.

Improvement of Calculation Accuracy in the Electron Monte Carlo Algorithm with Optional Air Profile Measurements

  • Sung, Jiwon;Jin, Hyeongmin;Kim, Jeongho;Park, Jong Min;Kim, Jung-in;Choi, Chang Heon;Chun, Minsoo
    • Progress in Medical Physics
    • /
    • v.31 no.4
    • /
    • pp.163-171
    • /
    • 2020
  • Purpose: In this study, the accuracies of electron Monte Carlo (eMC) calculation algorithms were evaluated to determine whether electron beams were modeled by optional air profiles (APs) designed for each applicator size. Methods: Electron beams with the energies of 6, 9, 12, and 16 MeV for VitalBeam (Varian Medical System, Palo Alto, CA, USA) and 6, 9, 12, 16, and 20 MeV for Clinac iX (Varian Medical System) were used. Optional APs were measured at the source-to-detector distance of 95 cm with jaw openings appropriate for each machine, electron beam energy, and applicator size. The measured optional APs were postprocessed and converted into the w2CAD format. Then, the electron beams were modeled and calculated with and without optional APs. Measured profiles, percentage depth doses, penumbras with respect to each machine, and energy were compared to calculated dose distributions. Results: For VitalBeam, the profile differences between the measurement and calculation were reduced by 0.35%, 0.15%, 0.14%, and 0.38% at 6, 9, 12, and 16 MeV, respectively, when the beams were modeled with APs. For Clinac iX, the differences were decreased by 0.16%, -0.31%, 0.94%, 0.42%, and 0.74%, at 6, 9, 12, 16, and 20 MeV, respectively, with the insertion of APs. Of note, no significant improvements in penumbra and percentage depth dose were observed, although the beam models were configured with APs. Conclusions: The accuracy of the eMC calculation can be improved in profiles when electron beams are modeled with optional APs.

Electron Accelerator Shielding Design of KIPT Neutron Source Facility

  • Zhong, Zhaopeng;Gohar, Yousry
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.785-794
    • /
    • 2016
  • The Argonne National Laboratory of the United States and the Kharkov Institute of Physics and Technology of the Ukraine have been collaborating on the design, development and construction of a neutron source facility at Kharkov Institute of Physics and Technology utilizing an electron-accelerator-driven subcritical assembly. The electron beam power is 100 kW using 100-MeV electrons. The facility was designed to perform basic and applied nuclear research, produce medical isotopes, and train nuclear specialists. The biological shield of the accelerator building was designed to reduce the biological dose to less than 5.0e-03 mSv/h during operation. The main source of the biological dose for the accelerator building is the photons and neutrons generated from different interactions of leaked electrons from the electron gun and the accelerator sections with the surrounding components and materials. The Monte Carlo N-particle extended code (MCNPX) was used for the shielding calculations because of its capability to perform electron-, photon-, and neutron-coupled transport simulations. The photon dose was tallied using the MCNPX calculation, starting with the leaked electrons. However, it is difficult to accurately tally the neutron dose directly from the leaked electrons. The neutron yield per electron from the interactions with the surrounding components is very small, ~0.01 neutron for 100-MeV electron and even smaller for lower-energy electrons. This causes difficulties for the Monte Carlo analyses and consumes tremendous computation resources for tallying the neutron dose outside the shield boundary with an acceptable accuracy. To avoid these difficulties, the SOURCE and TALLYX user subroutines of MCNPX were utilized for this study. The generated neutrons were banked, together with all related parameters, for a subsequent MCNPX calculation to obtain the neutron dose. The weight windows variance reduction technique was also utilized for both neutron and photon dose calculations. Two shielding materials, heavy concrete and ordinary concrete, were considered for the shield design. The main goal is to maintain the total dose outside the shield boundary less than 5.0e-03 mSv/h during operation. The shield configuration and parameters of the accelerator building were determined and are presented in this paper.

Distribution Function and Drift Velocities in Mixtures of SF6 and Ar (SF6-Ar 혼합기체의 전자분포함수와 이동속도)

  • Kim, Sang-Nam
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.146-150
    • /
    • 2010
  • Distribution Function and Drift velocities for electrons in $SF_6$-Ar mixtures gases used by MCS-BEq algorithm has been analysed over the E/N range 30~300[Td] by a two term Boltzmann equation and by a Monte Carlo simulation using a set of electron cross sections determined by other authors, experimentally the electron swarm parameters for 0.2[%] and 0.5[%] $SF_6$-Ar mixtures were measured by time-of-flight method. The results obtained in this work will provide valuable information on the fundamental behaviors of electrons in weakly ionized gases and the role of electron attachment in the choice of better gases and unitary gas dielectrics or electro negative components in dielectric gas mixtures. The results show that the deduced electron drift velocities agree reasonably well with theoretical for a rang of E/N values.

A study on the transient electron transport in GaAs bulk (GaAs 벌크에서 전자의 과도 전송 특성)

  • 임행삼;황의성;심재훈;이정일;홍순석
    • Electrical & Electronic Materials
    • /
    • v.10 no.3
    • /
    • pp.268-273
    • /
    • 1997
  • In this paper the transient electron transport in GaAs bulk is simulated by using ensemble Monte Carlo method. To analyze the transient electron transport the 10000 electrons in the .GAMMA. valley are simulated simultaneously for 10 picoseconds. The electric field-velocity relation is obtained. The high impurity density reduces the negative differential resistance effect. The result of transient average velocity shows the electron velocity in the transient state is faster than that in the steady state. This transient velocity overshoot is caused by the intervalley scattering mechanism. And we confirmed the fact that the energy relaxation time is longer than the momentum relaxation time.

  • PDF

Analysis of electron transport properties of $CF_4+Ar$ mixtures gas by the TOF method (TOF법에 의한 $CF_4+Ar$ 혼합기체의 전자수송특성 해석)

  • 서상현;하성철;유회영
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.279-283
    • /
    • 1998
  • The electron swarm parameters in the$CF_4$(O.l%, 5%)+Ar mixtures are measured by time of flight method over the E/N(Td) range from 10 to 300LTdl. A two-term approximation of the Boltzmann equation analysis and Monte Carlo simulation have been also used to study electron transport coefficients. We have calculated W, NDL, NDT, $\alpha$ and the limiting breakdown electric field to gas mixtures ratio in pure $CF_4$ gas and$CF_4+Ar$ mixtures. The measured results and the calculated results have been compared each other paper.

  • PDF