Energy calibration is important to identify accurate neutron capture resonance energy in the neutron TOF (Time-of-Flight) experiment. In present study, the accurate neutron capture resonance energies of natural Sm were measured by using a 46-MeV electron linear accelerator (linac) at the Research Reactor Institute, Kyoto University(KURRI). The BGO spectrometer were adopted for measurement the prompt capture gamma-ray of the sample. To obtain energy calibration curve, resonance energy of a gold sample used as standard resonance energy Mughabghab's data (From neutron resonance parameters data). Previous data (by Mughabghab) of natural Sm sample have been compared with the present result.
목적 : 환자의 치료에 있어서 정확한 장비의 설치와 성능 평가는 치료의 질을 향상시키는데 중요한 요소라고 할 수 있으며 사용자가 장비의 특성과 사용 방법을 숙달하고 업무를 수행하는 것이 매우 중요하다고 생각한다. 그러므로 방사선 치료기를 설치하고 방사선 치료를 하기 전에 사용자가 직접 장비의 설치와 성능 평가에 참여하고 특성을 파악하여 이해하는 것이 필요하다. 본 연구에서는 CAP의 과정과 성능 평가결과를 소개하고자 한다. 대상 및 방법 : 선형가속기 21EX(varian, USA)를 대상으로 설치 시부터 성능 검사까지 전 과정을 평가하였고 성능평가는 크게 radiation survey, mechanical test, radiation isocenter test, beam performance, dosimetry, enhanced dynamic wedge로 구분하여 X-omat film(kodark), 선량 측정 장비(multidata, densitometer, electrometa)를 이용하여 실시하였다. 또한 선형가속기에 부착된 MLC(millenium, 120leaf)와 EPID(portal vision)의 성능 평가는 별도로 실시하였다. 결과 : Survey meter를 이용하여 측정한 leakage는 허용 범위 이하의 선량이 검출되었고 mechanical test에서 collimator, gantey, couch rotation은 1mm 이하였고 육안으로 평가한 angle은 digital이 ${\pm}1^{\circ}$이내에 mechanical은 ${\pm}5^{\circ}$이내였다. 또한 light field와 cross-hair의 직선성 검사도 1mm이내로 평가되었다. (A)symmetrical jaw field는 upper/lower 모두 ${\pm}0.5mm$이내였다. X-omat film을 이용한 radiation isocenter test는 1mm 이하였고 light field와 radiation field 의 일치성 검사는 ${\pm}1mm$ 이내였으며 선량 측정 장비를 이용하여 측정한 $\%DD$는 photon energy는 모두 ${\pm}1\%$ 이내로 electron energy는 $90\%,\;80\%,\;50\%,\;30\%$를 측정한 결과 허용 범위 내에서 평가되었다. photon 과 electron energy의 flateness는 각각 $2.3\%$(기준 $3\%$)이내, $3\%$(기준 $4.5\%$)이내이고 symmetry는 $0.45\%$(기준 $2\%$), $0.3\%$(기준 $2\%$)이내에서 평가 할 수 있었다. 그리고 dosimetry test는 sort term, MU setting, rep rate, dose rate accuracy를 photon과 electron energy 별로 MU와 gantry angle을 바꿔가면서 측정한 결과 허용범위 오차이내에 포함되는 것을 확인 할 수 있었다. EPID(portal vision)의 Exact-Arm의 기계적인 검사는 vertical, lateral, longitudinal은 허용범위 내에서 동작했으며 명암과 해상도 검사도 05.mm의 니크롬선이 선명하게 나타났으며 phantom의 음영도 뚜렷하게 나타났다. Multileaf collimator(MLC)검사는 leaf이 isocenter의 중심에 정확하게 배열되었으며 재현성 검사도 정상적으로 동작하였다. 결론 : Clinac 21EX 장치의 customer acceptance를 통해서 향후의 환자의 치료를 하는데 있어 장치의 안정성을 확인 할 수 있었으며 치료 전의 선형가속기와 주변장치의 특성을 파악 할 수 있어서 장비 사용에 있어서 어려움을 감소시킬 수 있으리라고 생각된다. 또한 사용자가 적극적으로 참여함으로써 앞으로 환자를 치료하는데 있어서도 많은 도움이 되리라 생각한다.
본 연구는 6 MeV LINAC에서 발생한 X-선을 생쥐 생체에 조사한 후, 방사선 조사선량에 따른 난소 조직의 미세구조적 변화를 광학 및 전자현미경으로 관찰하였다. X-선을 200 cGy의 선량을 조사한 후 적출한 난소조직에서 성장난포의 과립층세포는 핵이 응축되어 나타났고, 난자를 둘러싸고 있는 투명층은 정상 대조군에서보다 경계가 불규칙하게 관찰되었다. 400 cGy로 조사된 난소조직에서 과립층세포는 대부분 응축된 핵을 가지고 있었으며, 피폭된 과립층세포의 사멸에 의한 세포질의 단백질 변성이 확인되었다. 600 cGy의 선량을 조사한 난소의 조직표본에서 성장난포는 위축되어 있었으며, 난포동에는 백혈구가 침윤되어 있었고, 난포액은 정상난포와 달리 불균질한 물질로 채워져 있었다. 투과전자현미경으로 관찰한 결과, 200 cGy의 방사선을 조사한 성장난포에서 과립층세포는 정상난포와는 달리 불규칙한 모양을 하고 있었다. 과립세포 사이의 난포동에는 많은 세포성분의 부스러기가 산재하여 있었으며, 이들 주변에 호중구와 대식세포가 관찰되어, 이 시기에 이미 방사선 피폭에 의한 세포사의 기작이 진행되고 있음이 확인되었다. X-선을 600 cGy로 조사한 난소조직의 과립층세포는 세포의 형태나 핵의 변형이 현저하여, 일부 세포는 핵의 분절화가 진행되는 등, apoptosis의 전형적인 특징이 관찰되었다. 특히 성장난포의 난포동에서는 염증반응에 관여하는 호중구가 잘 관찰되었으며, 주변에 산재된 세포 파쇄물 및 apoptotic body와 함께 대식세포의 출현도 확인되었다.
The klystron-modulator(K&M) system of the Pohang Light Source(PLS) had been supplying high power microwaves for the acceleration of 2.5 GeV electron beams since October 2002. There are 12 sets of K&M systems to accelerate electron beams to 2.5GeV nominal beam energy. One module of the K&M system consists of an 80 MV S-band (2856 MHZ) klystron tube and the matching 200 MW modulator. In order to obtain electron beam of the consequently stability for linac, the pulse-to-pulse beam voltage regulation is less than $+/-0.5\%$. To get the reliable stability of the modulator which is less than $+/-0.5\%$, a charging section is improved in a modulator which has been operated with inverter power supply.
방사선치료용 고 에너지 전자선의 조직내 선량분포는 매우 다양하게 나타나고 있으며 조직내에서 일정 깊이까지만 선량이 집중적으로 부여되고 그 이후에는 선량이 급감하는 특징으로 인하여 피부 및 피부에서 깊지않은 종양과 구강, 질강 등 강내조사에 존재하는 종양치료에 널리 이용되고 있다. 하지만 의료용 선형가속기에는 강내조사용 조사통(cone)이 제공되지 않고 있다. 본 실험은 2.5, 3.0, 3.5 cm ø 크기의 강내조사용 소조사면 조사통을 수직형과 30$^{\circ}$ 경사형으로 6가지를 직접 제작하여 에너지별, 조사통 크기별로 조직내 선량분포 특성을 실험하여 임상적 선량계획에 필요한 자료를 제공하는데 목적을 두고 실험하였다. 심부선량은 조사통 크기, 에너지 크기, 조사통 각도에 따라 다르게 나타나고 있으며 유효선량 깊이는 전자선 에너지 및 조사통이 커질수록 약간 증가하였고, X선 오염정도는 1.2% 이하로 나타났으며, 출력흡수선량율은 약 15-86 %로 나타났다. 고 에너지 전자선은 강내치료에 매우 유용하게 이용될 수 있으며, 조직내 선량분포 특성이 매우 다양한 양상을 나타내고 있음을 확인하였고 이러한 결과를 자료화하여 임상적 치료와 새로운 선량분포 모형 연구에 필요한 자료를 제공할 수 있으리라 생각한다.
Jeong, Dong Hyeok;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Lee, Sang Jin;Kim, Hee Chang;Lee, Kyohyun;Kim, Seung Heon;Lee, Dong Eun;Jang, Kyoung Won
Nuclear Engineering and Technology
/
제53권4호
/
pp.1289-1296
/
2021
In this study, an electron-scattering device was fabricated to practically use the ultra-high dose rate electron beams for the FLASH preclinical research in Dongnam Institute of Radiological and Medical Sciences. The Dongnam Institute of Radiological and Medical Sciences has been involved in the investigation of linear accelerators for preclinical research and has recently implemented FLASH electron beams. To determine the geometry of the scattering device for the FLASH preclinical research with a 6-MeV linear accelerator, the Monte Carlo N-particle transport code was exploited. By employing the fabricated scattering device, the off-axis and depth dose distributions were measured with radiochromic films. The generated mean energy of electron beams via the scattering device was 4.3 MeV, and the symmetry and flatness of the off-axis dose distribution were 0.11% and 2.33%, respectively. Finally, the doses per pulse were obtained as a function of the source to surface distance (SSD); the measured dose per pulse varied from 4.0 to 0.2 Gy/pulse at an SSD range of 20-90 cm. At an SSD of 30 cm with a 100-Hz repetition rate, the dose rate was 180 Gy/s, which is sufficient for the preclinical FLASH studies.
Total 12 units of high power klystron-modulator systems as microwave source is under operation for 2.5-GeV electron linear accelerator in Pohang Light Source(PLS) linac. RF power and beam power of klystron are precisely measured for the effective control of electron beam. A precise measurement and measurement equipment with good response characteristics are required for this. Input power of klystron is calculated from the applied voltage and the current on its cathode. Tiny measurement error severely effects RF output power value of klystron. Therefore, special care is needed to measure precise beam voltage. Capacitive voltage divider(CVD) unit is intended for the measurement of beam voltage of 400 kV generated from the pulsed klystron-modulator system. Main parameter to determine the standard capacitance in the high arm of CVD is dielectric constant of insulation oil. Therefore CVD should be designed to have a minimum capacitance variation due to voltage, frequency and temperature in the measurement range. This paper will discuss the analysis of capacitive voltage divider for a pulsed high-voltage measurement, and the empirical relations between capacitance and oil temperature variation.
본 시험은 군전자장비의 전원제어부품으로 사용되는 TPS54315소자에 대하여 과도방사선에 따른 과도응답특성인 Upset/Latch-up특성을 평가하기 시험으로 포항가속기 연구소내의 Test LINAC 조사시설을 이용하여 $1.43{\times}10^7$rad(si)/sec~$1.25{\times}10^8$rad(si)/sec 선량률 조건에서의 실측시험을 수행하였다. 시험결과 $1.0{\times}10^8$rad(si)/sec 이후 Latch-up 현상이 확인되었으며 연속펄스 인가 시 Latch-up상태에서 정상상태로 복귀하는 결과를 확인하였다. 또한 이러한 현상은 과도방사선에 의한 광전류가 내부전원 Reset로직을 트리거 시킴으로써 Latch-up상태에서의 전원바이어스를 일시적으로 차단함에 따라 발생된 것으로 본 실험을 통하여 Reset회로가 내장된 소자의 경우 일부 Latch-up현상과 동시에 Reset회로가 트리거 되는 경우 Latch-up상태에서 정상상태로 복귀되는 결과를 확인하였다.
본 연구는 교토대학 원자로실험소의 46-MeV전자선형가속기에서 발생된 전자선을 Ta표적에 충돌시켜 발생된 중성자를 이용하였다. 발생된 중성자는 납감속측정장치(LSDS:Lead Slowing-down Spectrometer))속에서 감속되었고 중성자비행시간법(TOF:Time-of-Flight)을 이용하여서 중성자에너지를 선별하여 $^{197}Au$의 중성자포획단면적을 중성자에너지 0.1 eV에서 10 keV범위에 걸쳐 측정하였다. 발생된 중성자속을 측정하기 위하여 $BF_3$검출기속의 $^{10}B(n,{\gamma})$반응을 이용하였고 이것을 이용하여 중성자 반응 단면적을 상대적으로 얻었다. TOF방법으로 얻어진 결과는 1 eV에서의 결과(24.5 b)에 규격화되었다. 기존의 실험결과들과 평가결과들인 JENDL/D-99 Dosimetry File과 비교하였다.
목적: 의료환경의 변화와 교육환경의 변화에 신속하게 대처하기 위하여 대학에서는 필요한 실습 장비를 갖추고 있어야 한다. 그러나 재정적인 부담과 그것들을 유지 관리하는데 생기는 어려움으로 인해 국내의 대학들이 고가의 방사선 치료 장치를 설치하기는 불가능하다. 이로 인한 실습의 제약을 해소하기 위하여 김천대학 방사선과에서는 모형 선형가속기 및 모형 부속기구를 제작하여 학생들의 실습 시간에 활용하고 있으며 그 유용성에 대해 보고하고자 한다. 대상 및 방법: 우리가 자체 제작한 모형 선형가속기(DLINAC-001)는 실제 선형가속기와 동일한 회전지지축(gantry)과 조사 head의 회전이 가능하도록 제작하였다. 또한 실습교육의 극대화를 위해 우리는 자체적으로 모형 맞춤블록, 모형 쐐기필터, 모형 전자선 조사통과 환자고정기구를 제작 하였다. 결 과: 선형가속기의 기계적인 기능과 동일하게 모형 선형가속기를 활용할 수 있으며, 다양한 용도의 모형 부속기구들을 실습 시 활용할 수 있다. 결 론: 김천대학 방사선과에서 제작된 모형 선형가속기와 부속기구를 제작하여 학생들의 실습시간에 활용함으로서 다양한 영역의 임상실습이 가능하다. 또한 현장감 있는 실습을 시행함으로서 학습 효과를 극대화 할 수 있으며, 임상에서 요구하는 실무능력을 함양할 수 있다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.