• Title/Summary/Keyword: Electromagnetic standard

Search Result 365, Processing Time 0.026 seconds

Analysis of Design Elements in HEMP Systems (HEMP 시스템의 설계 요소 분석)

  • Lee, Sun Yui;Kim, Jin Young;Park, Woo Chul
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.4
    • /
    • pp.6-11
    • /
    • 2013
  • In this paper, we explain the signal characteristics of HEMP and HEMP protection factors that affect the facilities are analyzed. We find the necessary elements of the physical facilities available for building. Shielding effects were measured by changing frequency and the distance of receiving antenna. Each measured value was compared to U.S. standard and measuring method was simplified. shielding effects were measured by three different conditions of shielding room. Find the difference between forward measurement and reverse measurement and factors which affects the measurement in shielding room.

A New Analysis of Waveguide Structure Using the Iterative Green's Function Method Applicable to the Electromagnetics Instruction (전파 교육에 적용할 수 있는 반복 그린함수 방법을 이용한 전자파 도파관 구조의 새로운 해석법)

  • 조용희
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2003.05a
    • /
    • pp.403-405
    • /
    • 2003
  • An iterative Green's function method (IGFM) is introduced to analyze complex electromagnetic waveguide structures in view of the university student. The IGFM utilizes the Green's function and iteration scheme. The physical mechanism with simple mathematical equations is used to formulate the IGFM. Scattering characteristics of a standard E-plane T-junction in a parallel-plate waveguide are theoretically investigated in terms of the IGFM. Numerical computations illustrate the characteristics of resection and transmission powers versus frequency. A dominant-mode solution is presented and compared with the higher-mode solutions.

  • PDF

Novel Analysis of Waveguide Stub Structure Using Iterative Green's Function Method (반복 그린 함수 방법을 이용한 도파관 스텁 구조의 새로운 해석법)

  • Cho, Yong-Heui
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.2
    • /
    • pp.125-131
    • /
    • 2007
  • An iterative Green's function method (IGFM) is introduced in order to analyze complex electromagnetic waveguide stub structures in view of a university student. The IGFM utilizes a Green's function approach and an regional iteration scheme. A physical iteration mechanism with simple mathematical equations facilitates clear formulations of the IGFM. Scattering characteristics of a standard E-plane T-junction stub in a parallel-plate waveguide are theoretically investigated in terms of the IGFM. Numerical computations illustrate the characteristics of reflection and transmission powers versus frequency.

Recognition of PD Sources in Air by STFT and Stochastic Parameters (STFT 및 통계적 처리에 의한 공기 중 부분방전원 식별)

  • 이강원;박성희;강성화;임기조
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.1
    • /
    • pp.101-106
    • /
    • 2004
  • The phenomenon of PD(Partial Discharge) is accompanied by electromagnetic wave which can be detected by UHF(Ultra High Frequency) antenna. The signals obtaining from UHF antenna are very high rapid pulse and have wide band frequency responses. The distribution of PRPD(Phase Resolved Partial Discharge) which consisted of those pulse train can show distinct characteristics of PD sources. But it is not sufficient to discriminate among PD sources. This paper suggests that the stochastic parameters formed by preprocessing of STFT(Short Time Fourier Transform) are good tools for differentiate from PD sources. The stochastic parameters are CC(Cross Correlation) mean value, CC standard deviation, CC skewness, CC kurtosis.

A Study on the Optical Modem for Data Link Realization (데이타 링크 구성을 위한 광 모뎀에 관한 연구)

  • 유태훈;은재정;박한규
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1986.10a
    • /
    • pp.198-200
    • /
    • 1986
  • In this paper, the optical modem for data link realization is designed with the advantages of optical fiber : large handwidth, no electromagnetic interference, high speed and long-haul communications. Biphase cording format is used for the sync, and async, transmissions. Modem interface conform to the CCITT V.24 standard for the compatibility with existing systems. 0/E and E/0 converters are designed using LED-APD pair for long wave length and LD-APD for short wave length, respectively. As a result, the system is capable of transmitting at any bps within dc to 200Kbps in async, and at 1200bps up to 57.6Kbps in sync. transmission.

  • PDF

Doppler Rader Location of Weather Information System for Power System Operation (전력계통(電力系統) 기상정보(氣象情報)시스템의 도플러레이다 위치(位置) 선정(選定))

  • Kim, Yeong-Han;Lee, Hyo-Sang;Kim, Jai-Young
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.206-210
    • /
    • 1989
  • With the economy expands and the increasing living standard of people, the better quality of electricity which is closely related with weather conditions should be supplied to the customers especially using precised facilities. In this paper, the configuration of the weather information system and its application to the power system operation are generally introduced. And also, a method with test result is presented to find the suitable radar coverage area including the condition of electromagnetic wave shut off.

  • PDF

Analysis of Safety Distance and Maximum Permissible Power of Resonant Wireless Power Transfer Systems with Regard to Magnetic Field Exposure

  • Park, Young-Min;Byun, Jin-Kyu
    • Journal of Magnetics
    • /
    • v.20 no.4
    • /
    • pp.450-459
    • /
    • 2015
  • In this paper, the safety distances and maximum permissible power (MPP) of resonant wireless power transfer systems are defined and derived with regard to human exposure to electromagnetic field (EMF). The definition is based on the calculated induced current density and electric field in the standard human model located between the transmitting and receiving coil. In order to avoid the adverse health effects such as stimulation of nerve tissues, the induced current and electric field must not exceed the basic restriction values specified in EMF safety guidelines. The different combinations of diameters of the coils and the distance between the two coils are investigated and their effects are analyzed. Two versions of EMF safety guidelines (ICNIRP 1998 and ICNIRP 2010) are used as bases for safety distance calculation and the difference between the two guidelines are discussed.

Analysis of time-varying low-frequency electric magnetic field emitted from electric rolling stocks fed by VVVF inverter (VVVF 인버터로 구동되는 전기철도차량에서 방출되는 시변 저주파 전자계 분석)

  • Jang, Dong-Uk;Kim, Joo-Rak;Kim, Heol-Cheol
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.507-513
    • /
    • 2010
  • This paper is described the analysis of time-varying low-frequency electric magnetic field emitted from electric rolling stocks fed by VVVF inverter, in reference to allowable magnitude for exposures to time-varying electromagnetic field issued by International Commission on Non-Ionizing Radiation Protection(ICNIRP). The level of the magnetic field strength was measured, in reference to the standard for occupational environments, which takes into account the public person's protection against the excessive emission of the low-frequency magnetic field, 5 Hz ~ 2 kHz.

  • PDF

Detect to Impulse Large Current based on faraday Effect (파라데이효과를 이용한 임펄스 대전류 측정)

  • Park, Hae-Soo;Kim, Yo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.505-507
    • /
    • 1995
  • Applications of the fiber optic sensing are glowing rapidly, particularly in situations where size, weight, speed, and immunity to electromagnetic interference are important considerations. The fiber optic current sensors have been developed for low frequency(60Hz) metering in electric power systems. But we try measure to high frequency large current by fiber optic current sensor based on Bi substituted rare earth iron garnet. In this paper, we report the linearity to 500 amperes and frequency response of signal processor and a result of detection the standard impulse large current of fiber optic impulse sensor system.

  • PDF

Reduction of Conducted EMI Noise in Boost Converter using Sigma-Delta Modulation Technique (Sigma-Delta 변조기법을 이용한 Boost Converter의 전도 노이즈 저감)

  • Lee Sung-Hee;Choi Tae-Young;Gu Ja-sung;Won Chung-Yuen;Kim Gyu-Sik;Choi Se-Wan
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.494-497
    • /
    • 2002
  • Conducted electromagnetic interference (EMI) from switch mode power supplies (SMPS) has become a major problem due to the proliferation of these devices employing dc-dc converters using standard pulse width modulation (PWM). In this paper, we proposed the sigma-delta modulation $({\sum}{\Delta}M)$ as an alternative switching technique to reduce the conducted EMI in SMPS. A comparative investigation on conducted EMI generated by PWM and ${\sum}{\Delta}M$ techniques are experimentally performed on a 300W Boost converter.

  • PDF