• Title/Summary/Keyword: Electromagnetic loss

Search Result 1,060, Processing Time 0.025 seconds

Quad-Band Antenna Switch Module with Integrated Passive Device and Transistor Switch (수동 집적 회로 및 트랜지스터 스위치를 통한 4중 대역 안테나 스위치)

  • Jeong, In-Ho;Shin, Won-Chul;Hong, Chang-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.11
    • /
    • pp.1287-1293
    • /
    • 2008
  • Antenna switch module(ASM) for quad-band was developed. This module was integrated by RFIPD(RF integrated passive device) and transistor switch instead of LTCC-type device using low pass filters, diodes and passive elements in RF front end module for cellular phone. This module leads to low cost and miniaturization(The area is $5{\times}5\;mm$ and the thickness is 0.8 mm). The insertion loss and the return loss of each band were averagely measured as 1.0 dB(insertion loss), 15.1 dB(GSM/EGSM return loss) and 19 dB(DCS/PCS return loss), respectively.

Transient Characteristic Study on Contact Loss of High Speed Electric Railway Using a Power Line Disturbance Simulator (전원외란 시뮬레이터를 이용한 고속전철 이선현상과도 특성 연구)

  • Kim, Jae-Moon;Kim, Yang-Su
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.427-431
    • /
    • 2009
  • In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated from an electrical response point of view. To analysis power line disturbance by induced contact loss phenomenon for high speed operation, a hardware Simulator which considered contact loss between contact wire and the pantograph as well as contact wire deviation is developed. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system. One of the most important needs accompanied by increasing the speed of high-speed train is reduced that an arc phenomenon by loss of contact brings out EMI. In case of a high-speed train using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI(Electromagnetic Interference), dummy signal injection etc usually occurs. Throughout experiment, it is verified that an arc phenomenon is brought out for simulator operation and consequently conducted noise is flowed in electric circuit by power line disturbance.

An Interference Analysis Method with Site-Specific Path Loss Model for Wireless Personal Area Network

  • Moon, Hyun-Wook;Kwon, Se-Woong;Lee, Jong-Hyun;Yoon, Young-Joong
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.4
    • /
    • pp.290-295
    • /
    • 2010
  • In this paper, an interference analysis method with a site-specific path loss model for a wireless personal area network (WPAN) is proposed. The site-specific path loss model is based on geometrical optics and geometric probability to consider both site-specific radio propagation characteristics and a closed-form expression to obtain the mean interference from which the uniformly distributed multiple interferers are derived. Therefore, the proposed interference analysis method can achieve more computational simplicity than the Monte-Carlo (MC) simulation, which uses the ray-tracing (RT) technique. In addition, better accuracy than the conventional interference analysis model that uses stochastic method can also be achieved. To evaluate the proposed method, a signal to the interference-noise ratio with a mean interference concept for uniformly distributed interferers is calculated and compared in two simulation scenarios. As a result, the proposed method produces not only better matched results with the MC simulation using the RT technique than the conventional interference analysis model, but also simpler and faster calculation, which is due to the site-specific path loss model and closed-form expression for interference calculation.

A Study on the Evaluation and Countermeasure of Electromagnetic Interference due to Buildings in TV Frequency Band (건축물에 의한 TV주파수대 전자파장해의 평가 및 대책에 관한 연구)

  • 박재석;김동일;박연준;이창우
    • Journal of the Korean Institute of Navigation
    • /
    • v.22 no.1
    • /
    • pp.55-62
    • /
    • 1998
  • In this paper, we have performed a numerical calculation of the scattered electromagnetic field around the building to evaluate electromagnetic interference caused by the building in the TV frequency band. The relations between the exposed concrete area of a building wall and the magnitude of the reflected wave have been examined in the case that the electroagnetic wave absorbers partially cover the building wall. From the obtained scattered electromagnetic field, we have calculated the DU radio and the required reflection loss of the electromagnetic wave absorbers which attached on the building wall to protect TV ghost.

  • PDF

A Equivalent Finite Element Model of Lamination for Design of Electromagnetic Engine Valve Actuator

  • Kim, Jin-Ho
    • Journal of Magnetics
    • /
    • v.11 no.4
    • /
    • pp.151-155
    • /
    • 2006
  • The electromagnetic engine valve actuator is a key technology to achieve variable valve timing in internal combustion engine and the steel core and clapper of the electromagnetic engine valve actuator are laminated to reduce the eddy current loss. To design and characterize the performance of the electromagnetic engine valve actuator, FE (finite element) analysis is the most effective way, but FE (finite element) 3-D modeling of real lamination needs very fine meshes resulting in countless meshes for modeling and numerous computations. In this paper, the equivalent FE 2-D model of electromagnetic engine valve actuator is introduced and FE analysis is performed using the equivalent FE 2-D model.

A Square Coaxial Transmission Line with a Thin-Wire Inner Conductor to Measure the Absorbing Performance of Electromagnetic Absorbers

  • Kang, Tae-Weon;John Paul;John Paul
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.1
    • /
    • pp.43-49
    • /
    • 2004
  • A low-frequency coaxial reflectometer(LCR) with a thin-wire inner conductor is designed and constructed to measure nondestructively the absorbing performance of electromagnetic absorbers in the frequency range of 10 MHz to 200 MHz. The LCR consists of a square coaxial transmission line and a network analyzer with a time-domain measurement capability. Inherent characteristics of a square coaxial line with a thin-wire inner conductor which deteriorate the impedance matching of the input port of the LCR are addressed. And the characteristics are improved by employing a multiwire inner conductor. Measured and calculated reflection losses of a flat ferrite tile absorber are presented.

Electromagnetic Wave Propagation in Anisotropic Composite Structures (이방성 복합재료의 전자기파 투과특성)

  • 전흥재;신현수
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.04a
    • /
    • pp.407-414
    • /
    • 2002
  • The knowledge of interaction of electromagnetic waves in composite structures is important for designing the shielding structure for antenna such as radome. Recently, radomes are constructed in the form of foam core sandwich structures that have many mechanical advantages such as high strength, long fatigue life, low density and adaptability to the intended function of structure. However, the propagation of electromagnetic waves is affected by high anisotropic permeability and loss tangent of the composite skin. In this study, the analytical model to understand the propagation of electromagnetic waves in the anisotropic composites and foam core sandwich structures with composite skins was proposed. Numerical analyses of unidirectional composites and foam core sandwich structure as a function of incident angle were performed. From the results of analysis, the general tendencies of transmittance of electromagnetic wave through composites and foam core sandwich structure were obtained.

  • PDF

Radiated Electromagnetic Field Calculation due to Arc Discharge according to Speed of High Speed Train (고속철도의 속도에 따른 아크에 의한 전자파 방사 계산)

  • Han, In-Su;Lee, Tae-Hyung;Cho, Hong-Shik;Park, Choon-Soo;Kim, Ki-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.98-100
    • /
    • 2011
  • High speed Train Systems are the energy supplied system via the pantograph through which the voltage and the current supplied by the catenary wire flow. The arc discharges generate owing to the contact loss between the catenary and the pantograph, and the electromagnetic fields radiate. There are many different phenomena between the static charges and the moving charges in view of the radiated electromagnetic fields. To calculate the electromagnetic filed about the moving charges, it is necessary to adapt Lorentz transformation. Actually, the particle which moves near the speed of light has the relativisitic phenomena. In addition, it is necessary to predict the electromagnetic field because the radiated electromagnetic field takes effect on the near electronic devices and the human beings. In this paper, we model the arc discharge into the dipole antenna model, adapt Lorentz transformation to the case that the electric railway cars move, and calculate the radiated electromagnetic field. By the calculation, we take the basis upon the electromagnetic prediction, and apply to the future research.

  • PDF

The Study on Empirical Propagation Path Loss in the Airport Cargo Terminal Environment (공항 화물터미널 환경에서 실험적인 패스 로스에 관한 연구)

  • Kim, Kyung-Tae;Park, Hyo-Dal
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.12
    • /
    • pp.1140-1147
    • /
    • 2013
  • In this paper, The path loss model of Air Traffic Control(ATC) telecommunication radio channel has been studied at the Incheon International Airport(IIA) Cargo Terminal. We measured one frequency among VHF channel bands. The transmitting site was located at different locations with different heights. The transmitting site radiated the Continuous Wave(CW). The propagation measurement was taken using the moving vehicle equipped with receiver and antenna. The transmitting power, frequency and antenna height are the same as the current operating condition. The path loss exponent and intercept parameters were extracted by the basic path loss model and hata model. The path loss exponent at IIA Cargo terminal area were 3.67 and 3.39 respectively in first and second transmitting sites. The deviation of prediction error is 14.42 and 10.38. The new path loss equation at the IIA Cargo terminal area was also developed using the derived path loss parameters. The new path loss was compared with other models. This result will be helpful for the ATC site selection and service quality evaluation.

Analysis of Field Strength and Path Loss in Seoul and Daejeon Area (서울 및 대전지역에서의 전계강도와 경로손실 분석)

  • 송기홍;정인명;김종호;양기곤
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.4 no.2
    • /
    • pp.4-10
    • /
    • 1993
  • In mobile radio communication, propagation paths are time or spacial varying because of the motion of mobile unit. The propagation path loss not only involves frequency and distance but also the antenna height at both the base station and the mobile unit, terrain configuration, and the man made en- vironment. Thhese additional factors make the prediction of propagation path loss of mobile radio signals more difficult. In this paper, it is measured field strenght of mobile radio signals in Daejeon and Seoul area, also calculated local median, 500m sample mean, and stadard deviation. As the result of analysis, it can be seen that propagation path loss of measured data is similiar to predicted field strength, especially local median is dependent upon base antenna height, terrain configuration and the man-made environment. The standard deviation has been noted to lie between 2 and 10 dBuV.

  • PDF