• Title/Summary/Keyword: Electromagnetic behavior

Search Result 189, Processing Time 0.024 seconds

Development of a Broadband Self-recording Hydrophone

  • Kim, Bong-Chae
    • Ocean and Polar Research
    • /
    • v.28 no.2
    • /
    • pp.145-151
    • /
    • 2006
  • A broadband self-recording hydrophone was developed to conveniently assemble a hydrophone array for use in receiving underwater sound waves. A trigger device with an electromagnetic induction coupler was also developed to control the hydrophone's operation. Main configurations and specifications of the self-recording hydrophone are introduced in this paper. We present experiment results conducted in a water tank to examine the operating behavior of the hydrophone. Some advantages are discussed when the self-recording hydrophones are used to make up a hydrophone array.

A Novel Dielectric Resonator Bandpass Filter with Variable Attenuation Poles for Duplexer Applications (가변 감쇠극을 갖는 새로운 구조의 유전체 공진기 대역통과 여파기 의 설계)

  • 조상호;성영제;김영식
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2001.11a
    • /
    • pp.202-206
    • /
    • 2001
  • In this paper a novel dielectric resonator (DR) bandpass filter (BPF) with flexible arrangement of attenuation poles is proposed. This DR filter is similar to a conventional DR filter except adding a microstrip line below a DR, which not only shifts the location of attenuation poles, but also improves skirt characteristics. The duplexer with the proposed DR BPF has been yielded better isolation and sharper skirt behavior than that with a conventional DR alter. The implemented duplexer has shown a good performance and been well agreed with the simulation.

  • PDF

Dyadic Green`s Function for an Unbounded Anisotropic Medium in Cylindrical Coordinates

  • Kai Li;Park, Seong-Ook;Pan, Wei-Yan
    • Journal of electromagnetic engineering and science
    • /
    • v.1 no.1
    • /
    • pp.54-59
    • /
    • 2001
  • The dyadic Green`s function for an unbounded anisotropic medium is treated analytically in the Fourier domain. The Green`s function, which is expressed as a triple Fourier integral, can be next reduced to a double integral by performing the integral, by performing the integration over the longitudinal Fourier variable or the transverse Fourier variable. The singular behavior of Green`s is discussed for the general anisotropic case.

  • PDF

Improved Circuit Model for Simulating IGBT Switching Transients in VSCs

  • Haleem, Naushath Mohamed;Rajapakse, Athula D.;Gole, Aniruddha M.
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1901-1911
    • /
    • 2018
  • This study presents a circuit model for simulating the switching transients of insulated-gate bipolar transistors (IGBTs) with inductive load switching. The modeling approach used in this study considers the behavior of IGBTs and freewheeling diodes during the transient process and ignores the complex semiconductor physics-based relationships and parameters. The proposed circuit model can accurately simulate the switching behavior due to the detailed consideration of device-circuit interactions and the nonlinear nature of model parameters, such as internal capacitances. The developed model is incorporated in an IGBT loss calculation module of an electromagnetic transient simulation program to enable the estimation of switching losses in voltage source converters embedded in large power systems.

Development of Magnetized Ferromagnetic Stainless Steel Acupuncture Needle (강자성(强磁性) 스테인리스강(鋼) 자화침(磁化鍼)의 개발)

  • Hong, Do Hyun
    • Journal of Acupuncture Research
    • /
    • v.31 no.2
    • /
    • pp.21-30
    • /
    • 2014
  • Objectives : Manufacturing and manipulation techniques of acupuncture can be interpreted as an induced electromagnetic viewpoint, as proposed in previous study. Considering from this point of view, the magnetization of needles should be essential to enhance the electromagnetic effects during the behavior of the acupuncture needling. Methods : The current disposable needles are made of non-magnetic stainless steels, so ferromagnetic materials were searched as suitable substitutes. Meanwhile, at the practical view, stainless steels are very available for the several superior properties like as corrosion resistance, strength, etc., magnetic stainless steels were first investigated. Some types of them still preserved the ferromagnetic properties of iron, so trial needles were made with them. And then magnetization of them were followed. Results : Among the hundreds types of stainless steels, martensitic or ferritic ones are ferromagnetic. The needles made with these ferromagnetic wires were magnetized, and polarized by magnetizer, and their magnetic properties were improved. Moreover, in addition to the superiority of the magnetism, the electrical and thermal conductivities of them were even better than those of the current austenitic stainless steels. Conclusions : Through the developmental study based on the electromagnetic viewpoint, the magnetized and polarized acupuncture needles were completed. This means that these needles having improved magnetism can be used to improve the electromagnetic needling effects, and moreover, their superiorities in the electrical and thermal conductivities can also give another benefits in treatments of electrical or warm needling.

A Finite Element Analysis of Electromagnetic Forming for Tube Expansion (전자기 확관성형의 유한요소 해석)

  • 이성호;이동녕
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.1872-1885
    • /
    • 1991
  • The analysis of electromagnetic forming process consists of the analysis of the electric circuit and the dynamic deformation analysis. The purpose of the electric circuit analysis is to calculate the magnetic pressure and to apply it to the deformation analysis. Some investigators performed the analysis assuming the pressure distribution in longitudinal direction. However there was a difference between the calculated and experimental results. The difference mainly came from the assumption of the pressure distribution. One must know the magnetic field distribution in an actual situation for the analysis to be less erroneous. In this work the electromagnetic field analysis was performed by the finite element method to obtain a more realistic pressure distribution. A better agreement between the calculated and experimental results was obtained. It became possible to predict the deformation behavior of the workpiece of finite length.

Manipulation and diagnosis of femtosecond relativistic electron bunch using terahertz-driven resonators

  • Yang Xu;Yifang Song;Cheng-Ying Tsai;Jian Wang;Zhengzheng Liu;Kuanjun Fan;Jinfeng Yang;Oleg Meshkov
    • Nuclear Engineering and Technology
    • /
    • v.56 no.10
    • /
    • pp.4237-4246
    • /
    • 2024
  • Using strong electromagnetic fields generated by lasers to interact with electrons for precise diagnosis and manipulation of electron beams represents a recent focal point in accelerator technology. This approach surpasses the limitations of conventional RF technology, such as low electric field gradients and timing jitters, effectively enhancing the accuracy of ultrafast electron beam diagnostics and manipulations. As demands for precision continue to rise, the precise diagnosis of crucial parameters of ultrafast electron beams remains challenging. This study delves into the electromagnetic behavior of THz-driven devices and proposes an all-optical method utilizing single-cycle THz radiation to compress and characterize a 3 MeV electron beam. Particle tracking simulations demonstrate an astonishing compression effect, reducing the bunch length from 54.0 fs to 4.3 fs, and achieving sub-femtosecond bunch length measurement resolution. Moreover, when combined with an orthogonal THz streak camera, this method shows even greater potential in multi-bunch scenarios.

The Electromagnetic and Thermal Properties of the Mn-Zn Ferrite for the Power Line Communication

  • Lee, Hae-Yon;Kim, Hyun-Sik;Huh, Jeoung-Sub;Oh, Young-Woo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.12C no.4
    • /
    • pp.220-224
    • /
    • 2002
  • The electromagnetic properties and thermal behavior of Mn-Zn ferrite cores for the blocking filter of PLC application were investigated as the function of additives. The highest density and permeability were 4.98 g/㎤ and 8,221, respectively and were obtained to the specimen with composition of MnO 24 mol%, ZnO 25 mol% and Fe$_2$O$_3$51 mol%, added MoO$_3$ of 400 ppm, SiO$_2$ of 100 ppm, and CaO of 200 ppm. The uniform grains were organized, and the microstructures were compacted due to reduction of pores in the specimen. The permeability was increased up to 13,904 as the temperature of specimen increased to 110。C. However, it was decreased precipitously under 100 over 110。C. The exothermic behavior was observed in the frequency range from 1 kHz to 1 MHz, and the maximum temperature of specimen was 102。C at 1 MHz. In the consequence, the Mn-Zn ferrite core developed in this research will maintain the stable electromagnetic properties since the temperature of ferrite core rose to 93 。C in the range of 100 kHz to 450 kHz bandwidth qualified for PLC. The blocking filters were designed for single phase and three phases using the in-line and non-contact core. The best attenuation ratios of -46.46 dB and -73.9 dB were measured in the range of 100 kHz to 450 kHz bandwidth, respectively.

Electromagnetic Properties of Magnetic Core Materials and Attenuation of Blocking Filter (Blocking filter용 자심 재료의 전자기 특성 및 신호 감쇄율)

  • 오영우;이해연;김현식
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.6
    • /
    • pp.490-495
    • /
    • 2003
  • The electromagnetic properties and thermal behavior of Mn-Zn ferrite cores for the blocking filter of Power Line Communication(PLC) application were investigated as a function of additives. The highest density and permeability were 4.98 g/$\textrm{cm}^2$ and 8,221, respectively and were obtained to the specimen with composition of MnO 24 mol%, ZnO 25 mol% and Fe$_2$O$_3$ mol%, added MoO$_3$ of 400 ppm, SiO$_2$ of 100 ppm, and CaO of 200 ppm. The uniform grains were organized, and the microstructures were densified due to reduction of pores in the specimen. The permeability was increased up to 13,904 as the temperature of specimen increased to 110$^{\circ}C$. However, it was decreased precipitously under 100 over 110$^{\circ}C$. The exothermic behavior was observed in the frequency range from 1 kHz to 1 MHz, and the maximum temperature of specimen was 102$^{\circ}C$ at 1 MHz. In the consequence, the Mn-Zn ferrite core developed in this research will maintain the stable electromagnetic properties since the temperature of ferrite core rose to 93$^{\circ}C$ in the range of 100 kHz to 450 kHz bandwidth qualified for PLC. The blocking filters were designed for single phase and three phases using the in-line and non-contact core. The best attenuation ratios of -46.46 dB and -73.9 dB were measured in the range of 100 kHz to 450 kHz bandwidth, respectively.

Development of Flow Control Valve Using MR Fluid (MR유체를 이용한 유량제어 밸브)

  • Lee, Hyung-Don;Bae, Hyung-Sub;Lee, Yuk-Hyung;Park, Myeong-Kwan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.9
    • /
    • pp.888-891
    • /
    • 2011
  • This paper presents development of flow control valve using MR fluid. Generally, since the apparent viscosity of MR fluids is adjusted by applying magnetic fields, the MR valves can control high level fluid power without any mechanical moving parts. In this paper, flow control valve using MR fluid on the behavior of the magnetic field influence on the numerical analysis of more accurate electromagnetic parameters were obtained, even if when magnetic field apply inside of surrounding MR fluid from electromagnet, more realistic designing way analysis of characteristic of whole magnetic field distribution is suggested by surrounding magnetic material. Also, comparison of flow rate inlet and outlet, behavior of MR fluid in experiments proposed. A new type of flow control valve using MR fluid is proposed by analysis of behavior of MR fluid in experiments.